• Title/Summary/Keyword: H.235

Search Result 482, Processing Time 0.03 seconds

Operation-level Early Termination Algorithm for Inter-predictions in HEVC

  • Rhee, Chae Eun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.4
    • /
    • pp.235-242
    • /
    • 2016
  • The emerging High-Efficiency Video Coding (HEVC) standard attempts to improve coding efficiency by a factor of two over H.264/Advanced Video Coding (AVC) at the expense of an increase in computational complexity. Mode decision with motion estimation (ME) is still one of the most time-consuming computations in HEVC, as it is with H.264/AVC. Thus, fast mode decisions are not only an important issue to be researched, but also an urgent one. Several schemes for fast mode decisions have been presented in reference software and in other studies. However, the conventional hierarchical mode decision can be useless when block-level parallelism is exploited. This paper proposes operation-level exploration that offers more chances for early termination. An early termination condition is checked between integer and fractional MEs and between the parts of one partition type. The fast decision points of the proposed algorithm do not overlap those in previous works. Thus, the proposed algorithms are easily used with other fast algorithms, and consequently, independent speed-up is possible.

Crystallization of 28 kDa Clonochis sinesis Glutathione S-transferase

  • Kim, Young-Kwan;Chung, Yong-Je
    • Korean Journal of Crystallography
    • /
    • v.14 no.1
    • /
    • pp.32-34
    • /
    • 2003
  • A helminth glutathione S-transferase. 28 kDa isozyme from Clonorchis sinensis has been crystallized under several conditions. One of the crystals, grown from a 10% polyehtylene glycol MME 550 (PEG MME 5 K) solution in 0.05 M potassium phosphate buffer (pH 7.0), diffracts to $3.0{\AA}$ resolution, and belongs to monoclinic space group C2, with unit cell parameters $a=95.83{\AA}$, $b=63.82{\AA}$, $c=235.09{\AA}$, and ${\beta}=97.2^{\circ}$.

Design and implementation of AMD system for response control in tall buildings

  • Teng, J.;Xing, H.B.;Xiao, Y.Q.;Liu, C.Y.;Li, H.;Ou, J.P.
    • Smart Structures and Systems
    • /
    • v.13 no.2
    • /
    • pp.235-255
    • /
    • 2014
  • This paper mainly introduces recently developed technologies pertaining to the design and implementation of Active Mass Damper (AMD) control system on a high-rise building subjected to wind load. Discussions include introduction of real structure and the control system, the establishment of analytical model, the design and optimization of a variety of controllers, the design of time-varying variable gain feedback control strategy for limiting auxiliary mass stroke, and the design and optimization of AMD control devices. The results presented in this paper demonstrate that the proposed AMD control systems can resolve the issues pertaining to insufficient floor stiffness of the building. The control system operates well and has a good sensitivity.

Gas desorption species and quantity from the hot cathode ionization gauges (열음극 전리 진공게이지의 기체이탈 특성)

  • ;;;I. Arakawa
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.4
    • /
    • pp.201-206
    • /
    • 2003
  • A residual gas analyzer was used to study the outgassing behavior of stainless steel 304 chamber as a function of bake-out temperature up to $235 ^{\circ}C$ and to identify the gas species evolved during turn on and degassing of the three different types of hot cathode ionization gauges. It was found that $H_2O$, CO, and $H_2O$ were the dominent outgassing species in the vacuum chamber during bake-out but finally $H_2$ and CO(mass 28) persisted at room temperature. Dominant outgassing species were also $H_2$ and $H_2O$ while fuming on the ionizations and then $H_2$,$H_2O$ and CO were found to be the main species degassed gauges. It was appeared that the outgassing species and quantity were not agreed to the three different types of hot cathode ionization gauges.

Clinical Value of fine Needle Aspiration Biopsy in Head and Neck Masses (두경부 종물에 대한 세침천자생검의 임상적 의의)

  • 김성근;강성호;김경래;이형석;김선곤
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1993.05a
    • /
    • pp.103-103
    • /
    • 1993
  • Fine needle aspiration biopsy(FNAB) is widely used in screening of head and neck(H&N) masses because it has high accuracy and few damage. The 235 cases of FNAB were performed on patient with H&N mass at the Department of Otolaryngology, Hanyang University Hospital during 1 years, from March 1985 to February 1992. The 188 of 235 were proven histologically, clinically. The results obtained were as follows ; 1) FNAB for malignant H&N mass shows sensitivity of 81.5% specificity of 96.8%. 2) FNAB for malignant LN shows sensitivity of 86.0%, specificity of 88.9%. 3) FNAB for salivary gland shows sensitivity of 66.7%, specificity 81.8%. 4) FNAB for soft tissues, bone, and intraoral lesions shows sensitivity of 90%, specificity 95.8%. 5) FNAB for tuberculosis shows false negative of 55.2%. 6) The result of FNAB was not closely related with location or size of neck nodes.

  • PDF

Influence of PECVD SiNx Layer on Multicrystalline Silicon Solar Cell (PECVD SiNx 박막의 다결정 실리콘 태양전지에 미치는 영향)

  • Kim, Jeong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.7
    • /
    • pp.662-666
    • /
    • 2005
  • Silicon nitride $(SiN_x)$ film is a promising material for anti-reflection coating and passivation of multicrystalline silicon (me-Si) solar cells. In this work, a plasma-enhanced chemical vapor deposition (PECVD) system with batch-type reactor tube was used to prepare highly robust $SiN_x$ films for screen-printed mc-Si solar cells. The Gas flow ratio, $R=[SiH_4]/[NH_3]$, in a mixture of silane and ammonia was varied in the range of 0.0910.235 while maintaining the total flow rate of the process gases to 4,200 sccm. The refractive index of the $SiN_x$ film deposited with a gas flow ratio of 0.091 was measured to be 2.03 and increased to 2.37 as the gas flow ratio increased to 0.235. The highest efficiency of the cell was $14.99\%$ when the flow rate of $SiH_4$ was 350 sccm (R=0.091). Generally, we observed that the efficiency of the mc-Si solar cell decreased with increasing R. From the analysis of the reflectance and the quantum efficiency of the cell, the decrease in the efficiency was shown to originate mainly from an increase in the surface reflectance for a high flow rate of $SiH_4$ during the deposition of $SiN_x$ films.

Effect of Residual Impurities on Solid State Sintering of the Powder Injection Molded W-15 wt%Cu Nanocomposite Powder (분말사출성형한 W-15 wt%Cu 나노복합분말의 고상소결에 미치는 잔류불순물의 영향)

  • 윤의식;이재성;윤태식
    • Journal of Powder Materials
    • /
    • v.9 no.4
    • /
    • pp.235-244
    • /
    • 2002
  • The effects of residual impurities on solid state sintering of the powder injection molded (PIMed) W-15wt%Cu nanocomposite powder were investigated. The W-Cu nanocomposite powder was produced by the mech-ano-chemical process consisting of high energy ball-milling and hydrogen reduction of W blue powder-cuO mixture. Solid state sintering of the powder compacts was conducted at $1050^{\circ}C$ for 2~10 h in hydrogen atmosphere. The den-sification of PIM specimen was slightly larger than that of PM(conventional PM specimen), being due to fast coalescence of aggregate in the PIM. The only difference between PIM and PM specimens was the amount of residual impurities. The carbon as a strong reduction agent effectively reduced residual W oxide in the PIM specimen. The $H_2O$ formed by $H_2$ reduction of oxide disintegrated W-Cu aggregates during removal process, on the contrary to this, micropore volume rapidly decreased due to coalescence of the disintegrated W-Cu aggregates during evolution of CO.It can be concluded that the higher densification was due to the earlier occurred Cu phase spreading that was induced by effective removal of residual oxides by carbon.