• Title/Summary/Keyword: H. minimum

Search Result 1,701, Processing Time 0.03 seconds

Analysis of Minimum Airflow Differences between Supply and Exhaust Air according to Airtightness of Rapidly Converted Temporary Negative Pressure Isolation Rooms (긴급전환형 임시음압격리병실의 기밀도에 따른 최소 급배기 유량차 평가)

  • Shin, Hee Won;Kim, Dong Wook;Kim, Ji Min;Jung, Hyo Beom;Kang, Dong Hwa
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.4
    • /
    • pp.69-77
    • /
    • 2023
  • Purpose: During the COVID-19 pandemic, there have been many cases of converting regular hospital wards into temporary negative pressure isolation wards. The purpose of this study is to evaluate the minimum airflow differences that satisfies the pressure difference criteria(-2.5 Pa) according to airtightness of switching type wards, in preparation for utilization of aging regular wards as negative pressure isolation wards. Methods: Visual inspection and field measurements were conducted using blower door to evaluate airtightness of 5 hospital wards. CONTAM simulation was used to assess the airflow differences when pressure difference between the corridor and wards met the criteria at various levels of airtightness. Results: The ACH50 of evaluated wards ranged from 19.3 to 50.1 h-1 with an average of 37.0 h-1, indicating more than four times leakier than other building types. The minimum airflow differences increased as the airtightness of the wards decreased and the size of the wards increased. Implications: When operating rapidly converted negative pressure isolation wards, understanding airtightness is crucial for determining the minimum airflow differences to maintain the pressure differences. The analysis of this study suggests that improving the airtightness of aging rooms is essential and the minimum airflow differences should be suggested considering both the airtightness and size of rooms.

An Air Cleaning Efficiencies of Wet Air Cleaner in the Windowless Swine Fattening Stall in Summer (무창 비육돈사에서 습식공기정화기의 여름철 공기정화효율 분석)

  • Oh, I.H.;Lee, J.H.;Lee, K.H.;Lee, J.H.;Lee, D.S.;Eo, S.M.;Lee, M.L.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.3
    • /
    • pp.133-140
    • /
    • 2006
  • The climate of stall significantly influences on animal production ability. High concentration of ammonia gas, $CO_2$ and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and farmer health, and production ability. Therefore, it is necessary to keep clean the inside air of stall to increase the productivity. An air cleaner of wet type, consisting of a fan, a motor, rotating discs, a dust collector, a water bowl, an ozone generator etc, has been developed to clean the stall air. The work principle is that the inside air is sucked through the fan, and the rotating discs make water into fineness spray and blow into the stall. The rest water flows down to the dust collector. In the present study, we measured the dust, ammonia gas, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with On-mode and Off-mode of wet air cleaners. The dust measure was divided into 3 categories, TSP, $PM_{10}$, and $PM_{2.5}$. In summer, the TSP in on-mode were maximum $0.259mg/m^3$ and minimum $0.128mg/m^3$, and the average was $0.195mg/m^3$. These are comparable to the data from Off-mode stall that maximum $0.308mg/m^3$, minimum $0.139mg/m^3$, and average $0.277mg/m^3$. However, $PM_{10}$ and $PM_{2.5}$ showed any significant differences between the tests. The concentrations of ammonia gas in Off-mode stall were maximum 13.8 ppm and minimum 5.9 ppm, and the average was 8.47 ppm. However in On-mode stall the ammonia gas concentrations were maximum 10.5 ppm and minimum 5.5 ppm, and the average was 7.63 ppm. The concentration of ammonia gas in On-mode was 10% in average lower than off-mode stall. Odor was measured by olfactometer. In the Off-mode stall, the odor unit were maximum 420 $Ou/m^3$ and minimum $300\;OU/m^3$, and the average was $367\;OU/m^3$, but in the On-mode stall the odor unit were maximum $330\;OU/m^3$ and minimum $210\;OU/m^3$, and the average was $253\;OU/m^3$. Odor removal efficiency was about 31% in On-mode stall.

  • PDF

Rheological Studies on the Aqueous Suspension of Korean Bentonite (국산벤토나이트 현탁액의 유동학적 성질)

  • Kim, Eun-Hee;Rhee, Gye-Ju
    • YAKHAK HOEJI
    • /
    • v.34 no.5
    • /
    • pp.302-310
    • /
    • 1990
  • A study has been made of the Korean bentonite aqueous suspension contrast with American bentonite by means of XRD IR swelling, gel formation and rheogram at various conditions such as concentration, temperature and pH. The Korean bentonite was identified as montmorillonite clay containig a small proprotion of crystoballite and mordenite, and its swelling power were acceptable for requirements of Korean pharmacopeia regulations though its values were not satisfied. Korean bentonite swelled to 10 times and American one did to 15 times compared to its bulkiness of powder. The rheogram of Korean bentonite suspension reveals bulged pseudoplatic flow with yield value at higher concentration and pseudoplastic flow without yield value at lower concentration. The higher the concentration, the greater were the apparent viscosity and hysteresis loop. Korean bentonite suspension showed insignificant temperature dependence on both apparent viscosity and hysteresis loop and it was more temperature dependent on viscosity but less on hysteresis loop than those of American sample. The pH dependence was so high on viscosity that apparent minimum value was near pH 7 and maximum value at pH 3 or 7. The hysteresis loop appeared minimum over the pH range 5-7 and maximum near pH 3 or 11. The Korean bentonite was inferior to the American bentonite in swelling volume, gel formation, thioxotropy, however, it would be possible to improve the quality of Korean bentonite by developing the method of purification for bentonite clay.

  • PDF

A Robust Controller Design Method of the Fine Seek Control System with Velocity Disturbance (속도 성분의 진동 외란이 있는 미동 탐색 제어 시스템의 강인 제어기 설계 방법)

  • Lee, Moon-Noh;Shin, Jin-Ho;Kim, Seong-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.9
    • /
    • pp.805-812
    • /
    • 2007
  • This paper present a robust controller design method based on the estimation of velocity disturbance to construct a robust fine seek control system. A loop gain adjustment algorithm is introduced to accurately estimate the velocity disturbance in spite of the uncertainties of fine actuator. A weighting function is optimally selected from a minimum fine seek open-loop gain, calculated by estimating the velocity disturbance. A robust fine seek controller is designed by considering a robust $H_{\infty}$ control problem using the weighting function. The proposed controller design method is applied to the fine seek control system of a DVD rewritable drive and is evaluated through the experimental results.

Hysteresis and Mode Transition in Electrodeless Fluorescent Lamp (무전극 램프에서의 히스테리시스와 모드 변환)

  • Lee, Joo-Ho;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.453-453
    • /
    • 2007
  • Electrodeless fluorescent lamp exhibit two modes of operation: a low density mode in which the power is capacitively coupled to the plasma and which is known as the E-mode, and a higher density mode which is an inductive discharge known as the H-mode. The transition between these two(E to H) mode exhibits hysteresis. It is observed that transition currents change at different frequencies and hysteresis exists not only between the starting and minimum maintaining currents of the electromagnetic mode (H mode) discharge but also between the starting and minimum maintaining currents of the electrostatic mode (E mode) discharge. Hysteresis effect can be important role in dimming system.

  • PDF

Hysteresis and Mode Transition in Electrodeless Lamp (무전극램프 에서의 Hysteresis와 모드 변환 특성)

  • Lee, Joo-Ho;Yang, Jong-Kyung;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1560-1561
    • /
    • 2007
  • Electrodeless fluorescent lamp exhibit two modes of operation : a low density mode in which the power is capacitively coupled to the plasma and which is known as the E-mode, and a higher density mode which is an inductive discharge known as the H-mode. The transition between these two(E to H) mode exhibits hysteresis. It is observed that transition currents change at different frequencies and hysteresis exists not only between the starting and minimum maintaining currents of the electromagnetic mode (H mode) discharge but also between the starting and minimum maintaining currents of the electrostatic mode (E mode) discharge. Hysteresis effect can be important role in dimming system.

  • PDF

Position of the hyoid bone and its correlation with airway dimensions in different classes of skeletal malocclusion using cone-beam computed tomography

  • Shokri, Abbas;Mollabashi, Vahid;Zahedi, Foozie;Tapak, Leili
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.105-115
    • /
    • 2020
  • Purpose: This study investigated the position of the hyoid bone and its relationship with airway dimensions in different skeletal malocclusion classes using cone-beam computed tomography (CBCT). Materials and Methods: CBCT scans of 180 participants were categorized based on the A point-nasion-B point angle into class I, class II, and class III malocclusions. Eight linear and 2 angular hyoid parameters(H-C3, H-EB, H-PNS, H-Me, H-X, H-Y, H-[C3-Me], C3-Me, H-S-Ba, and H-N-S) were measured. A 3-dimensional airway model was designed to measure the minimum cross-sectional area, volume, and total and upper airway length. The mean crosssectional area, morphology, and location of the airway were also evaluated. Data were analyzed using analysis of variance and the Pearson correlation test, with P values <0.05 indicating statistical significance. Results: The mean airway volume differed significantly among the malocclusion classes(P<0.05). The smallest and largest volumes were noted in class II (2107.8±844.7 ㎣) and class III (2826.6±2505.3 ㎣), respectively. The means of most hyoid parameters (C3-Me, C3-H, H-Eb, H-Me, H-S-Ba, H-N-S, and H-PNS) differed significantly among the malocclusion classes. In all classes, H-Eb was correlated with the minimum cross-sectional area and airway morphology, and H-PNS was correlated with total airway length. A significant correlation was also noted between H-Y and total airway length in class II and III malocclusions and between H-Y and upper airway length in class I malocclusions. Conclusion: The position of the hyoid bone was associated with airway dimensions and should be considered during orthognathic surgery due to the risk of airway obstruction.

Relations between Variation of Sea Surface Temperatures in the South Sea of Korea and Intensity of Typhoons (남해 해수면온도 변화와 태풍 세기와의 관계)

  • Seol, Dong-Il
    • Journal of Navigation and Port Research
    • /
    • v.32 no.5
    • /
    • pp.403-407
    • /
    • 2008
  • Relations between variation of SSTs(sea surface temperatures) in the South Sea of Korea and intensity of typhoons which passed through the South Sea of Korea was analyzed for 36 years from 1970 to 2005. The SSTs in the South Sea show the rising trends continuously. The mean SST of the last 10 years(1996-2005) is higher $1.03^{\circ}C$ than the mean SST during 10 years(1970-1979). The rising trends are especially strong after 1994. The intensity of typhoon can be shown by the minimum sea level pressure. The minimum sea level pressures of typhoons which passed through the South Sea show the descending trends. The mean minimum sea level pressure of the last 10 years(1996-2005) is lower 10.1hPa than that during 10 years(1970-1979). The correlation analysis shows that the rising of SSTs in the South Sea has relations with the strengthening of intensity of typhoons.

On the Weight Reduction of Longitudinal Members of Mid-Sized Bulk Carrier Considering the Minimum Shear Force according to Compartment Arrangement based on H-CSR (구획배치에 따른 최소 전단력을 고려한 H-CSR 기반 중형 살물선 종강도 부재의 중량 절감 방안 연구)

  • Na, Seung-Soo;Song, Ha-Cheol;Jeong, Sol;Park, Min-Cheol;Bae, Sang-Don
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.4
    • /
    • pp.352-359
    • /
    • 2017
  • Because the Energy Efficiency Design Index(EEDI) came into effect in 2013, it is necessary to develop a new technology to overcome $CO_2$ emission regulations. In structural design viewpoint, lots of researches are carried out to develop eco-friendly and high fuel efficiency ships by weight reduction. By using the automated compartment arrangement system and automated structural design algorithm which were developed by the authors, new researches are performing to combine the above two systems. However, the effect of weight reduction was not significant because structural designs by using these systems for the midship part was carried out only focused on the minimum still water bending moment. In this paper, at first, good compartment arrangements which give the minimum still water bending moment and(or) shear force were chosen by using the automated compartment system. And then, influence of shear force on weight reduction was investigated by using the automated structural design algorithm considering longitudinal strength, local strength and shear strength of longitudinal members in cargo holds. Conclusively, it is necessary to consider the minimum still water bending moment and shear force simultaneously to reduce the weight of mid-sized bulk carrier. Also, good compartment arrangement which gives much more weight reduction compared with existing ship was proposed.

Antimicrobial Activity of Phenolic-Rich Extracts from Mango Seed Kernel on Microorganisms

  • Dang Thi Thu Tam;Ly Nguyen Binh;Tran Chi Nhan;Nguyen Bao Loc;Nguyen Nhat Minh Phuong
    • Microbiology and Biotechnology Letters
    • /
    • v.51 no.4
    • /
    • pp.416-424
    • /
    • 2023
  • Replacing synthetic additives to preserve food products with natural antimicrobial compounds needs to be considered due to public health. In the present study, the phenolic extract from mango seed kernel (MSK) with the total phenolic content (TPC) value of 5300 ± 380 mg gallic acid equivalent (GAE)/L was used for evaluating the antimicrobial properties against five types of bacterial strains, including Listeria monocytogenes, Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, and Salmonella typhimurium in vitro. This extract was also used for in situ method on the storage of Pangasianodon hypophthalmus fish fillets. The minimum inhibitory concentration (MIC) values for all tested strains were determined at an average concentration of 1325 mg GAE/L. Furthermore, the minimum bactericidal concentration (MBC) values of E. coli, S. aureus, and S. typhimurium were seen at 5300 mg GAE/L, while the extract did not show eliminations in the growth of the remaining strains. The bacterial inhibition speed of the extract illustrated that the concentration equal MIC value eliminated S. typhimurium growth after 24 h, the 4 times MIC value had remarkable effects on S. aureus growth after the 9 h of incubation, and 24 h of incubation for E. coli, L. monocytogenes, P. aeruginosa. Additionally, the MSK extract could inhibit the growth of P. aeruginosa on fish fillets in 4 days of storage. These results provide important evidence for the utilization of MSK as a natural source of antimicrobial agents in food products.