• Title/Summary/Keyword: H-beam Structure

Search Result 300, Processing Time 0.025 seconds

Design of L-Band Cylindrical Active Phase Array Antenna Using Bent Dipoles (접힌 다이폴 구조를 적용한 L-Band 원통형 능동 위상배열 안테나 설계)

  • Lee, Man-Gyu;Kwon, Ickjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.43-55
    • /
    • 2013
  • In this paper, we propose a cylindrical active phased array antenna of Beam Steering Characteristics in the horizontal plane(H-plane) and vertical plane(E-Plane) on the cylinder form array structure. We design the bent dipole antenna of the cylindrical array structure adapted excellent mutual-coupling characteristics, designed and manufactured the cylindrical array antennas and power combiner/divider unit for power dividing and combining on the antenna. The radiating elements array spacing of Cylindrical array antenna were determined to avoid grating lobes at half power beam steering. Beam steering of the antenna was implemented with 6-bit phase shifter in the transceiver and have been designed based on the characteristics the antenna beam steering at -24 degrees to 24 degrees horizontal, vertical 0 degrees to 36 degrees beam steering. A cylindrical active phased array antenna that produced for verification the performance of the antenna are measured radiation characteristics in accordance with beam steering at L-Band.

An Experimental Study on the Evaluation of the Fire-Resistance Performance of a Spray-Applied Rectangular Steel Structure (뿜칠피복 각형 강관의 내화성능 평가를 위한 실험적 연구)

  • Ok, Chi-Yeol;Kim, Jae-Jun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.1
    • /
    • pp.41-47
    • /
    • 2017
  • Structures of steel frame buildings getting vary depending on the development of construction technology. Fire-resistant steel beams and Columns accredited by accreditation bodies from the performance of various fire-resistant coating is applied to the current pillar method is most H-beams. H-beam has been proposed a non-load test specifications in the relevant regulations, its scope of accreditation to be granted without limitation of size H-beams from the performance of the test specification. However, in the case of the rectangular steel structure is to check its performance and to a separate one of the receive acknowledge and so take advantage of the cross-sectional shape factor in this study to test the performance of the fire-resistant structure proposed for standard test specimen.

The optimization of front bumper beam using Hot stamping Technology (핫스템핑 공법을 이용한 Front Bumper Beam 최적화)

  • Kim, D.H.;Kim, K.S.;Na, S.J.;Um, I.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.241-244
    • /
    • 2008
  • Automotive companies have conducted a study for light weigh body and crash safety. But It is difficult to adapt a mass production because of formability with high strength steel in the conventional stamping process. Recently, Automotive maker in the Europe, USA, Japan has applied a hot stamping with boron steel in the body structure. Hot stamping technology spread fast in various body parts of automobile. Bumper beam has been applied in the foreign automotive company so much nowadays. In this study, We will optimize crash performance of bumper beam using hot stamping through comparison with conventional bumper beam.

  • PDF

A new damage detection indicator for beams based on mode shape data

  • Yazdanpanah, O.;Seyedpoor, S.M.;Bengar, H. Akbarzadeh
    • Structural Engineering and Mechanics
    • /
    • v.53 no.4
    • /
    • pp.725-744
    • /
    • 2015
  • In this paper, a new damage indicator based on mode shape data is introduced to identify damage in beam structures. In order to construct the indicator proposed, the mode shape, mode shape slope and mode shape curvature of a beam before and after damage are utilized. Mode shape data of the beam are first obtained here using a finite element modeling and then the slope and curvature of mode shape are evaluated via the central finite difference method. In order to assess the robustness of the proposed indicator, two test examples including a simply supported beam and a two-span beam are considered. Numerical results demonstrate that using the proposed indicator, the location of single and multiple damage cases having different characteristics can be accurately determined. Moreover, the indicator shows a better performance when compared with a well-known indicator found in the literature.

Forced vibration analysis of damped beam structures with composite cross-section using Timoshenko beam element

  • Won, S.G.;Bae, S.H.;Jeong, W.B.;Cho, J.R.;Bae, S.R.
    • Structural Engineering and Mechanics
    • /
    • v.43 no.1
    • /
    • pp.15-30
    • /
    • 2012
  • A damped Timoshenko beam element is introduced for the DOF-efficient forced vibration analysis of beam-like structures coated with viscoelastic damping layers. The rotary inertia as well as the shear deformation is considered, and the damping effect of viscoelastic layers is modeled as an imaginary loss factor in the complex shear modulus. A complex composite cross-section of structures is replaced with a homogeneous one by means of the transformed section approach in order to construct an equivalent single-layer finite element model capable of employing the standard $C^{0}$-continuity basis functions. The numerical reliability and the DOF-efficiency are explored through the comparative numerical experiments.

Study on the behavior of beam-column connection in precast concrete structure

  • Kataoka, Marcela N.;Ferreira, Marcelo A.;El Debs, Ana Lucia H.C.
    • Computers and Concrete
    • /
    • v.16 no.1
    • /
    • pp.163-178
    • /
    • 2015
  • Due to the increase of the use of precast concrete structures in multistory buildings, this paper deals with the behavior of an specific type of beam-column connection used in this structural system. The connection is composed by concrete corbels, dowels and continuity bars passing through the column. The study was developed based on the experimental and numerical results. In the experimental analysis a full scale specimen was tested and for numerical study, a 3D computational model was created using a finite element analyze (FEA) software, called DIANA. The comparison of the results showed a satisfactory correlation between loading versus displacement curves.

Development of Manufacturing Technology for Crash Box Type Bumper Stay with Hydroforming (하이드로포밍을 이용한 크래쉬박스형 범퍼스테이 제조기술 개발)

  • Sohn S. M.;Lee M. Y.;Moon Y. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.38-42
    • /
    • 2005
  • A bumper comprises a bumper cover, a bumper beam for distributing the load from the impacts applied to the bumper cover and reinforcing the bumper, an absorber member interposed between the bumper cover and tile bumper beam, and a pair of bumper stays which secure the bumper beam to the vehicle body. A conventional bumper stay structure is assembled into several stamped parts, so several processes are needed and the structure is complicated. In this study the bumper stay is applied to the tubular hydroforming which is known to have several advantages such as the reduction of the number of the process and the part weight. The thickness distribution of the tube is mainly considered to evaluate the hydro-formability and the shape of the tube is determined.

  • PDF

Stabilization Control of Ball and Beam System Using Adaptive Fuzzy Inference Technique (적응 펴지 추론기법을 이용한 Ball and Beam 시스템의 안정화 제어)

  • Kim, T.W.;Kim, H.B.;Shim, Y.J.;Shon, Y.D.;Lee, J.T.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.720-723
    • /
    • 1997
  • The characteristics of ball and beam system using fuzzy inference technique can be described by fuzzy modeling. Therefore, this paper introduces a technique for fuzzy structure identification of nonlinear Input-output relation- ship using an adaptive fuzzy inference system. And the simulation result using adaptive fuzzy inference technique shows its effectiveness for fuzzy structure identification of nonlinear system.

  • PDF

On forced and free vibrations of cutout squared beams

  • Almitani, Khalid H.;Abdelrahman, Alaa A.;Eltaher, Mohamed A.
    • Steel and Composite Structures
    • /
    • v.32 no.5
    • /
    • pp.643-655
    • /
    • 2019
  • Perforation and cutouts of structures are compulsory in some modern applications such as in heat exchangers, nuclear power plants, filtration and microeletromicanical system (MEMS). This perforation complicates dynamic analyses of these structures. Thus, this work tends to introduce semi-analytical model capable of investigating the dynamic performance of perforated beam structure under free and forced conditions, for the first time. Closed forms for the equivalent geometrical and material characteristics of the regular square perforated beam regular square, are presented. The governing dynamical equation of motion is derived based on Euler-Bernoulli kinematic displacement. Closed forms for resonant frequencies, corresponding Eigen-mode functions and forced vibration time responses are derived. The proposed analytical procedure is proved and compared with both analytical and numerical analyses and good agreement is noticed. Parametric studies are conducted to illustrate effects of filling ratio and the number of holes on the free vibration characteristic, and forced vibration response of perforated beams. The obtained results are supportive in mechanical design of large devices and small systems (MEMS) based on perforated structure.

Simple method for static and dynamic analyses of guyed towers

  • Meshmesha, H.;Sennah, K.;Kennedy, J.B.
    • Structural Engineering and Mechanics
    • /
    • v.23 no.6
    • /
    • pp.635-649
    • /
    • 2006
  • The static and dynamic responses of guyed telecommunication towers can be determined by using two models, the space truss element model, and the equivalent beam-column element model. The equivalent beam-column analysis is based on the determination of the equivalent shear, torsion, and bending rigidities as well as the equivalent area of the guyed mast. In the literature, two methods are currently available to determine the equivalent properties of lattice structures, namely: the unit load method, and the energy approach. In this study, an equivalent beam-column analysis is introduced based on an equivalent thin plate approach for lattice structures. A finite-element modeling, using suitably modified ABAQUS software, is used to investigate the accuracy of utilizing the different proposed methods in determining the static and dynamic responses of a guyed tower of 364.5-meter high subjected to static and seismic loading conditions. The results from these analyses are compared to those obtained from a finite-element modeling of the actual structure using 3-D truss and beam elements. Good agreement is shown between the different proposed beam-column models, and the model of the actual structure. However, the proposed equivalent thin plate approach is simpler to apply than the other two approaches.