• 제목/요약/키워드: H-Section Steel

검색결과 221건 처리시간 0.024초

결정립 미세화에 따른 이상조직 탄소강의 하중에 따른 마멸 기구 (Sliding Wear Mechanism of Ultra-Fine Grained Low Carbon Dual Phase Steel as n Function of Applied Load)

  • 유현석;이슬기;신동혁;김용석
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 춘계학술대회 논문집
    • /
    • pp.421-424
    • /
    • 2007
  • Dry sliding wear behavior of ultra-fine grained (UFG) plain low carbon dual phase steel, of which microstructure consists of hard martensite in a ductile ferrite matrix, has been investigated. The wear characteristics of the UFG dual phase steel was compared with that of a coarse grained dual phase steel under various applied load conditions. Dry sliding wear test were carried out using a pin-on-disk type tester at various loads of 1N to 100N under a constant sliding speed condition of 0.20m/s against an AISI 52100 bearing steel ball at room temperature. The sliding distance was fixed as 1000m for all wear tests. The wear rate was calculated by dividing the weight loss, measured to the accuracy of 10-5g by the specific gravity and sliding distance. The worn surfaces and wear debris were analyzed by SEM, EDS and profilometer. Micro-vickers hardness of the cross section of worn surfaces were conducted to analyze strain hardening underneath the contact surfaces. The wear mechanism of the UFG dual phase steel was investigated with emphasis on the unstable nature of the grain boundaries of the UFG microstructure.

  • PDF

경정립 미세화에 따른 이상조직 탄소강의 하중에 따른 마멸기구 (Sliding Wear Mechanism of Ultra-Fine Grained Low Carbon Dual Phase Steel as a Function of Applied Load)

  • 유현석;이슬기;신동혁;김용석
    • 소성∙가공
    • /
    • 제16권4호
    • /
    • pp.299-303
    • /
    • 2007
  • Dry sliding wear behavior of ultra-fine grained(UFG) plain low carbon dual phase steel, of which microstructure consists of hard martensite in a ductile ferrite matrix, has been investigated. The wear characteristics of the UFG dual phase steel was compared with that of a coarse grained dual phase steel under various applied load conditions. Dry sliding wear test were carried out using a pin-on-disk type tester at various loads of 1N to 100N under a constant sliding speed condition of 0.20m/s against an AISI 52100 bearing steel ball at room temperature. The sliding distance was fixed as 1000m for all wear tests. The wear rate was calculated by dividing the weight loss, measured to the accuracy of 10-5g by the specific gravity and sliding distance. The worn surfaces and wear debris were analyzed by SEM, EDS and profilometer. Micro-vickers hardness of the cross section of worn surfaces were conducted to analyze strain hardening underneath the contact surfaces. The wear mechanism of the UFG dual phase steel was investigated with emphasis on the unstable nature of the grain boundaries of the UFG microstructure.

Cross-sectional analysis of arbitrary sections allowing for residual stresses

  • Li, Tian-Ji;Liu, Si-Wei;Chan, Siu-Lai
    • Steel and Composite Structures
    • /
    • 제18권4호
    • /
    • pp.985-1000
    • /
    • 2015
  • The method of cross-section analysis for different sections in a structural frame has been widely investigated since the 1960s for determination of sectional capacities of beam-columns. Many hand-calculated equations and design graphs were proposed for the specific shape and type of sections in pre-computer age decades ago. In design of many practical sections, these equations may be uneconomical and inapplicable for sections with irregular shapes, leading to the high construction cost or inadequate safety. This paper not only proposes a versatile numerical procedure for sectional analysis of beam-columns, but also suggests a method to account for residual stress and geometric imperfections separately and the approach is applied to design of high strength steels requiring axial force-moment interaction for advanced analysis or direct analysis. A cross-section analysis technique that provides interaction curves of arbitrary welded sections with consideration of the effects of residual stress by meshing the entire section into small triangular fibers is formulated. In this study, two doubly symmetric sections (box-section and H-section) fabricated by high-strength steel is utilized to validate the accuracy and efficiency of the proposed method against a hand-calculation procedure. The effects of residual stress are mostly not considered explicitly in previous works and they are considered in an explicit manner in this paper which further discusses the basis of the yield surface theory for design of structures made of high strength steels.

A numerical analysis on the performance of buckling restrained braces at fire-study of the gap filler effect

  • Talebi, Elnaz;Tahir, Mahmood Md.;Zahmatkesh, Farshad;Kueh, Ahmad B.H.
    • Steel and Composite Structures
    • /
    • 제19권3호
    • /
    • pp.661-678
    • /
    • 2015
  • Buckling Restrained Braces (BRB) have been widely used in the construction industry as they utilize the most desirable properties of both constituent materials, i.e., steel and concrete. They present excellent structural qualities such as high load bearing capacity, ductility, energy-absorption capability and good structural fire behaviour. The effects of size and type of filler material in the existed gap at the steel core-concrete interface as well as the element's cross sectional shape, on BRB's fire resistance capacity was investigated in this paper. A nonlinear sequentially-coupled thermal-stress three-dimensional model was presented and validated by experimental results. Variation of the samples was described by three groups containing, the steel cores with the same cross section areas and equal yield strength but different materials (metal and concrete) and sizes for the gap. Responses in terms of temperature distribution, critical temperature, heating elapsed time and contraction level of BRB element were examined. The study showed that the superior fire performance of BRB was obtained by altering the filler material in the gap from metal to concrete as well as by increasing the size of the gap. Also, cylindrical BRB performed better under fire conditions compared to the rectangular cross section.

Flexural performance of cold-formed square CFST beams strengthened with internal stiffeners

  • Zand, Ahmed W. Al;Badaruzzaman, W.H. Wan;Ali, Mustafa M.;Hasan, Qahtan A.;Al-Shaikhli, Marwan S.
    • Steel and Composite Structures
    • /
    • 제34권1호
    • /
    • pp.123-139
    • /
    • 2020
  • The tube outward local buckling of Concrete-Filled Steel Tube (CFST) beam under high compression stress is still considered a critical problem, especially for steel tubes with a slender section compared to semi-compact and compact sections. In this study, the flexural performance of stiffened slender cold-formed square tube beams filled with normal concrete was investigated. Fourteen (14) simply supported CFST specimens were tested under static bending loads, stiffened with different shapes and numbers of steel stiffeners that were provided at the inner sides of the tubes. Additional finite element (FE) CFST models were developed to further investigate the influence of using internal stiffeners with varied thickness. The results of tests and FE analyses indicated that the onset of local buckling, that occurs at the top half of the stiffened CFST beam's cross-section at mid-span was substantially restricted to a smaller region. Generally, it was also observed that, due to increased steel area provided by the stiffeners, the bending capacity, flexural stiffness and energy absorption index of the stiffened beams were significantly improved. The average bending capacity and the initial flexural stiffness of the stiffened specimens for the various shapes, single stiffener situations have increased of about 25% and 39%, respectively. These improvements went up to 45% and 60%, for the double stiffeners situations. Moreover, the bending capacity and the flexural stiffness values obtained from the experimental tests and FE analyses validated well with the values computed from equations of the existing standards.

비탄성 국부좌굴을 고려한 철골 모멘트 접합부의 회전능력에 대한 변수 연구 (Evaluation of Rotation Capacity of Steel Moment Connections ConsideringInelastic Local Buckling - Parametric Studies)

  • 이경구
    • 한국강구조학회 논문집
    • /
    • 제20권5호
    • /
    • pp.625-632
    • /
    • 2008
  • 동반논문(모델개발)에서는 특별철골모멘트골조의 강접합 보-기둥 접합부의 회전능력을 예측하기 위한 해석모델을 제안하였다. 본 논문에서는 접합부 회전능력 기준으로 두 개의 극한상태를 고려하였다. 첫째, 보 단면의 국부좌굴로 인해 공칭소성강도까지 강도저하가 발생하였을 때를 회전능력으로 보는 강도저하 극한상태를 고려하였다. 둘째, 큰 진폭의 변형이 몇 번 반복 후에 좌굴된 플랜지에서 소성변형률 축적으로 야기 되는 저주기 피로 파단을 극한상태로 고려하였다. 두 극한상태까지 제안한 모델을 이용하여 단조증가하중 및 반복하중하에 일련의 해석을 수행하였다. 실무설계에서 사용되는 범위안의 다양한 H-형강 보를 모델링한 후, 플랜지 및 웨브 폭-두께비와 같은 보 단면의 기하학적 변수가 WUF-W 접합부의 회전능력과 저주기 피로수명에 미치는 영향을 관찰하였다.

고강도 앵글을 적용한 선조립 합성기둥의 압축 실험 (Compression Test for Prefabricated Composite Columns Using High-Strength Steel Angles)

  • 황현종;엄태성;박홍근;이창남;김형섭
    • 한국강구조학회 논문집
    • /
    • 제24권4호
    • /
    • pp.361-369
    • /
    • 2012
  • 본 연구에서는 고강도 앵글을 사용한 선조립 합성기둥(PSRC 합성기둥)을 연구하였다. 2/3 축소모델의 PSRC 실험체 및 단면 중앙부에 H형강을 매입한 일반 SRC 실험체를 제작하여 중심압축실험을 수행하였다. 강재비와 횡철근 간격을 실험 변수로 고려하였다. 실험결과 단면 코너부 앵글에 의한 콘크리트 구속효과로 인하여 PSRC 합성기둥 실험체는 일반 SRC 합성기둥과 비교하여 하중 재하능력 및 변형능력이 우수한 것으로 나타났다. 또한 KBC 2009 설계기준에 의한 공칭압축강도보다 높은 하중저항능력을 나타냈다. 기존의 횡보강 콘크리트 재료모델을 적용하여 단면해석을 수행한 결과, 초기강성, 최대강도, 최대강도 이후의 강도 및 강성 저하 등에서 실험 및 해석결과가 비교적 잘 일치하는 것으로 나타났다.

콘크리트 충전강관 기둥과 PC 철근 콘크리트 보 접합부의 개발에 관한 연구(2) -콘크리트 강도, 판넬죤의 크기, 축력비를 변수로 한 접합부의 거동 특성- (A Study on Development for Joint of Concrete Filled Steel Tube Column and P.C Reinforced Concrete Beam(2) -The Behaviors Properties of Joint with Key Parameter, such as Strength of Concrete, size of Panel Zone and Axial Force ratio-)

  • 박정민;이승조;김화중
    • 한국강구조학회 논문집
    • /
    • 제9권1호통권30호
    • /
    • pp.107-120
    • /
    • 1997
  • The purpose of this study is to develop composite structural system which is to have versatility in plan design and to improve economical efficieney, to maximise structural capacity than existing structural system. In this viewpoint, it was investigated to the properties of structural behaviors for i oint consisting of concrete filled steel square tube column and P.C reinforced concrete beam through a series of hysteretic behavior experiment. In the previous report, researched to the properties of joints with key parameters. such as Axial Force ratio and section types. From the based on previous results, this study investigated the properties of this joints with key parameters, such as strength of concrete, size of panel zone and Axial Force ratio. The obtained results are summarised as follows. (1) Investigating for the failure mode of the beam-to-column joint, the specimens of S,LL and LH series(except for L5H) presented flexural failure mode. (2) The initial stiffness of joint was increasd as the decrease of axial force ratio and increase of the concrete strength. (3) The rotation resisting capacity was effective as the increment of the concrete strength and decrement of the axial force ratio. (4) The emprical formula to predict the ultimate capacity of joint model to introduce decrease coefficient according to the axial force ratio to superimpose shearing strength of steel web(H section) and bending strength of reinforced concrete beam was expected.

  • PDF

Plasma Paste Boronizing법에 의한 Ni-Cr-Mo강의 붕화물층 생성거동과 내 토사마모특성에 관한 특성 (A Study On the Sand Wear Resistance and Formation Behavior of Boride Layer Formed on Ni-Cr-Mo Steel by Plasma Paste Boronizing Treatment)

  • 조재현;박학균;손근수;윤재홍;김현수;김창규
    • 한국재료학회지
    • /
    • 제14권1호
    • /
    • pp.52-58
    • /
    • 2004
  • The surface property and formation behavior of a boride layer formed on Ni-Cr-Mo steel in a plasma paste boronizing treatment were investigated. The plasma paste boronizing treatment was carried out at 973~1273 K for 1-7 hrs under the gas ratio of Ar:H$_2$ (2:1). The thickness of the boride layer increased with increasing temperature and time in the boronizing treatment. The cross-section of the boride layer was a tooth structure and the hardness was Hv 2000~2500. XRD analysis revealed that the compound was identified as FeB, $Fe_2$B, and mixed phase of FeB/$Fe_2$B in the boride layer formed at 973~1073 K, 1173K, and 1273K, respectively. The Ni-Cr-Mo alloy boronized at 1173-1273 K showed the best excellent wear resistance against the sand. As a results of corrosion test in 1 M $H_2$$SO_4$ solution, $Fe_2$B formed on the matrix alloy exhibited higher corrosion resistance than FeB.

웨브 보강 형태에 따른 H형강 보부재의 내화성능에 관한 연구 (Study on Fire Resistance of H-Section Beams Filled with Concrete at Web)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제25권5호
    • /
    • pp.76-84
    • /
    • 2011
  • 건축물 화재는 인명과 재산피해가 동시에 유발될 수 있는 인위 재해이며, 피해의 최소화하기 위해서는 건축물 설계단계부터 화재안전에 관한 요구사항 특히 내화성능을 충족해야만 한다. 강구조물에서의 보부재는 수평하중 전달과 바닥하중을 축부재로 전달하는 주요 구조부재이며, 주로 H형강으로 시공되고 있다. H형강의 내화성능은 내화피복 시공에 의해서 만족되고 있으나, 구조성능과 내화성능을 동시에 향상시킬 수 있는 콘크리트 충전 보부재의 내화성능에 관한 연구 그리고 작용 하중비에 따른 내화성능 연구는 미진한 실정이다. 따라서 본 논문에서는 H형강 보부재와 H형강 웨브에 보통강도 및 고강도 콘크리트가 충전된 H형강 보부재를 대상으로 내화성능과 하중비에 따른 한계온도 자료를 확보하여 향후 성능적 내화설계의 기초자료로 활용하고자 한다.