• Title/Summary/Keyword: H-Section Steel

Search Result 221, Processing Time 0.022 seconds

A Study on Torsional Characteristics of the Car Body Types at Cornering Motion (선회주행 시 차체의 비틀림 특성에 관한 연구)

  • Lee, Joon-Seong;Cho, Seong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.739-744
    • /
    • 2017
  • Elastic deformation and fatigue damage can cause the permanent deformation of a kart's frame during turning, affecting the kart's driving performance. A kart's frame does not contain any suspension or differential devices and, therefore, the dynamic behavior caused by torsional deformation when driving along a curve can strongly affect these two kinds of deformations. To analyze the dynamic behavior of a kart along a curved section, the GPS trajectory of the kart is obtained and the torsional stress acting on the kart-frame is measured in real time. The mechanical properties of leisure and racing karts are investigated by analyzing their material properties and conducting a tensile test. The torsional stress concentration and frame distortion are investigated through a stress analysis of the frame on the basis of the obtained results. Leisure and racing karts are tested in each driving condition using driving analysis equipment. The behavior of a kart when being driven along a curved section is investigated through this test. Because load movement occurs owing to centrifugal force when driving along a curve, torsional stress acts on the kart's steel frame. In the case of a leisure kart, the maximum torsional stress derived from the torsional fatigue limit was found to be 230 MPa, and the torsional fatigue limit coefficient was 0.65 when driving at a speed of 40 km/h. Furthermore, the driving elements during the cornering of a kart were measured based on an actual auto-test after installing a driving measurement system, and the driving behavior of the kart was analyzed by measuring its vertical displacement.

Experimental Study on Flexural Structural Performance of Sinusoidal Corrugated Girder (파형 웨브주름 보의 휨성능에 관한 실험적 연구)

  • Kim, Jong Sung;Chae, Il Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.6
    • /
    • pp.503-511
    • /
    • 2015
  • In long span steel structure, the plate girder reinforced with stiffeners are commonly used. When choosing the cross section with deep depth of girder as well as narrow width, however, out of plane buckling can be a problem due to web slenderness. In an effort to solve this issue, current study determined the applicability of using corrugated web girder with deep depth as bending member, which is generally being utilized in both factory and warehouse nationwide. To accomplish this, we performed the loading test of H-shaped beam with sinusoidal corrugated web. Corrugated web CP-2.3 specimen exhibited 12% less maximal bending strength but CP-3.2 specimen exerted 24% increase in strength compared to plate web P-4.5. this result indicates that corrugated web provides enough strength even with unfavorable width-thickness ratio of plate. And bending as well as shear strength estimated by the Eurocode (EN 1993-1-5) were compared with both bending strength by loading test and shear strength estimated by KBC2009. In case of eurocode, increase in plate thickness did not help in bending performance improvement. moreover, shear performance was sensitive to the thickness of the web folds and the shape of the web plate.

Shear Experiments on Concrete Filled PHC Pile with Composite Shear Connectors with Rebar Holes (보강 철근 정착 홀을 갖는 합성 전단연결재를 적용한 콘크리트 충전 PHC말뚝의 전단성능 평가)

  • Kim, Jeong-Hoi;Park, Young-Shik;Min, Chang-Shik
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.3
    • /
    • pp.259-266
    • /
    • 2017
  • The purpose of this study was to contribute to the field application cost effectively and reasonably by developing the functional piles that reinforces shear force. CFP pile (Concrete Filled Pretensioned Spun High Strength Concrete Pile with Ring type Composite shear connectors) developed in this study increases the shear stress by placing composite shear connector and filling the concrete into hollow part of the pile. By placing the reinforcement (H13-8ea) and the reinforcement (H19-8ea) into hollow section inside of PHC piles, it also improves the shear strength due to increasing steel ratio. It reinforces shear strength effectively by dowel force that is generated by putting reinforcement (H13-8) into the holes of composite shear connectors for the composite behavior of filled concrete and PHC pile. The study was reviewed and compared the calculated result of the shear strength by limit state design method highway bridge design standards (2012) and experiment result of the shear strength by KS F 4306. We can design the shear strength reasonably as the safety ratio of 2.20, 2.15, 2.05 is shown comparing to design shear strength, according to design shear strength on each cross sections and the experiment results of the CFP pile.

Change of physical properties after diameter increase by electroplating of orthodontic rectangular stainless steel wire (전기도금을 이용한 스테인레스 스틸 각형 선재의 굵기 증가 후 물성 변화)

  • Lee, Jeong-Seok;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.131-140
    • /
    • 2003
  • The purpose of this study was to evaluate clinical applications of electroplating method through investigation of the physical properties of orthodontic rectangular wires according to varying their cross section. For the study, it was accomplished to electroplate the 0.016-inched orthodontic rectangular stainless steel wire. The cross section of stainless steel orthodontic rectangular wire increased from $0.016{\times}0.016inch\;to\;0.017{times}0.017inch$ by electroplating. The wire was heat treated to improve an adhesion between the wire and electroplated metal. h three-point bending test and torsion test were conducted in order to compare physical properties among three wire groups; $0.016{\times}0.016wires(group 016),\; electroplated\;0.016{\times}0.016wires(group\;016P)\;and\;0.017{\times}0.017$ wires (group 017). Through the investigations of each wire group, following results were obtained 1. At three-point bending test, the group Ol6P showed higher tendency in the degree of stiffness, yield strength and ultimate tensile strength than the group 016. Stiffness and ultimate tensile strength showed statistically significant differences between two groups at three-point bending test (p<0.05). 2. Stiffness, yield strength, and ultimate tensile strength of the group 016P showed lower tendency than those of the group 017 Stiffness showed statistically significant differences between two groups at three-point bending test (p<0.05). 3. Torque/twist rate, yield torsional moment, and ultimate torsional moment of the group 016P showed higher tendency than those of the group 016. All measurements showed statistically significant differences between two groups alter torsion test (p<0.05). 4. Torque/twist rate, yield torsional moment, and ultimate torsional moment of the group 0166P showed lower tendency than those of the group 017. Yield torsional moment, and ultimate torsional moment showed statistically significant differences between two groups after torsion test (p<0.05).

Analytical Structural Stability Evaluation for H-section Beams Made of Ordinary Structural Steels Based on Boundary Conditions at High Temperatures (일반 구조용 강재 적용 정정 및 부정정 보부재의 고온 시 해석적 내력 평가 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.33-38
    • /
    • 2015
  • Loads applied on the floor are transferred through beams to columns. The beams can be designed as both end fixed or simple beams. The load bearing capacity of a beam depends on each boundary condition. However, when the load bearing capacity of a beam is evaluated in fire tests, all kinds of beams are tested using simple beam conditions. In this study, an analytical method performed using heat transfer theory and heat stress analysis based on the mechanical and thermal properties of SS-400 steel at high temperature. This method was used to clarify the differences between the two types of boundary conditions at normal and high temperature. The results show that the load bearing capacity of a both-end fixed beam at high temperature is superior to that of a simple beam. Therefore, the application of simple beam conditions in fire tests for evaluation of load bearing capacity is conservatively safe compared to fixed boundary conditions.

Evaluation of Degradation of Isothermally Aged Plasma-Sprayed Thermal Barrier Coating (플라즈마 용사 열차폐 코팅의 열화 평가)

  • Koo, Jae-Mean;Seok, Chang-Sung;Kang, Min-Sung;Kim, Dae-Jin;Lee, Dong-Hoon;Kim, Mun-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.4
    • /
    • pp.475-480
    • /
    • 2010
  • The thermal barrier coating of a gas turbine blade was degraded by isothermal heating in a furnace and by varying the exposure time and temperature. Then, a micro-Vickers hardness test was conducted on the cross section of the bond coat and Ni-based superalloy substrate. Further, the thickness of TGO(Thermally Grown Oxide) was measured by using an image analyzer, and the changes in the microstructure and element contents in the coating were analyzed by using an optical microscope and by performing SEM-EDX analysis. No significant change was observed in the Vickers hardness of the bond coat when the coated specimen was degraded at a high temperature; delamination was observed between the top coat and the bond coat when the coating was degraded for 50 h at a temperature $1,151^{\circ}C$.

Design of Roof Side Rail by Hot Blow Forming using High Strength Aluminum (핫블로우 포밍을 이용한 고강도 알루미늄 루프 사이드 레일 설계)

  • M. G. Kim;J. H. Lee;D. C. Ko
    • Transactions of Materials Processing
    • /
    • v.32 no.6
    • /
    • pp.311-320
    • /
    • 2023
  • Recently, lightweight of automotive parts has been required to solve environmental problems caused by global warming. Accordingly, research and development are proceeded on manufacturing of parts using aluminum that can replace steel for lightweight of the automotive parts. In addition, high strength aluminum can be applied to body parts in order to meet both requirements of lightening and improving crash safety of vehicle. In this study, hot blow forming of roof side rail is employed to manufacturing of the automotive parts with high strength aluminum tube. In hot blow forming, longer forming times and excessive thinning can be occurred as compared with conventional manufacturing processes. So optimization of process conditions is required to prevent excessive thinning and to uniformize thickness distribution with fast forming time. Mechanical properties of high strength aluminum are obtained from tensile test at high temperature. These properties are used for finite element(FE) analysis to investigate the effect of strain rate on thinning and thickness distribution. Variation of thickness was firstly investigated from the result of FE analysis according to tube diameter, where the shapes at cross section of roof side rail are compared with allowable dimensional tolerance. Effective tube diameter is determined when fracture and wrinkle are not occurred during hot blow forming. Also FE analysis with various pressure-time profiles is performed to investigate the their effects on thinning and thickness distribution which is quantitatively verified with thinning factor. As a results, optimal process conditions can be determined for the manufacturing of roof side rail using high strength aluminum.

Design and Fabrication of a Pilot Scale Continuous Kimchi Pasteurizer (Pilot Scale 연속식(連速式) 김치순간살균(瞬間殺菌) 장치(裝置)의 설계(設計) 및 제작(製作))

  • Kim, Kong-Hwan;Gil, Gwang-Hoon;Chun, Jae-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.83-89
    • /
    • 1984
  • In order to study the feasibility of industrial application of Kimchi juice separation-pasteurization method, a pilot scale Kimchi pasteurizer was designed and fabricated. The apparatus consisted of five sections: Kimchi juice separation-mixing, holding, precooling and cooling sections. Stainless steel pipelengths required for the heat exchanging sections were determined based on an equation, $W{\;}C_p{\;}T{\;}={\;}U(2{\;}RL){\;}T_{1m}$. Overall heat transfer coefficients in preheating, holding, precooling and cooling sections were 875, 1398, 2036, and $288{\;}kcal/m^2h^{\circ}C$ at the flow rate of 4 l/min, respectively, and temperature profiles of each section were in good agreement with those predicted from design criteria. A preliminary test using Chinese radish Kimchi demonstrated that this method can effectively be used in commercial processing of kimchi.

  • PDF

Analytical Study on the Seismic Retrofit Method of Irregular Piloti Building Using Knee-Brace (Knee - Brace를 활용한 비정형 필로티 건물의 내진보강방안에 대한 해석적 연구)

  • Yoo, Suk-Hyung;Kim, Dal-Gee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.35-42
    • /
    • 2020
  • Torsional behavior due to the plane irregularities of the piloti building can cause excessive story drift in the torsionally outermost column, which can lead to shear failure of the column. As a seismic retrofit method that can control the torsional behavior of the piloti building, the expansion of RC wall, steel frame or steel brace may be used, but such methods may hinder the openness of the piloti floor. Therefore, in this study, linear dynamic analysis and nonlinear static analysis for piloti buildings retrofitted by knee brace were performed, and seismic performance evaluation and torsion control effect of knee brace were analyzed. The results showed that the shear force of the column increased when the piloti building retrofitted by knee brace, but it was effective in controlling the torsional deformation. In case of retrofit between knee brace and column by 30°, the shear force of the column increased less than that of 60°, and the lateral displacement of column was decreased in the order of □, ◯ and H in cross-section.

A Study on the changes of periodontal tissue after orthodontic tooth movement in young adult dogs (유성견에서 교정적 치아이동에 따른 치주조직 변화에 관한 연구)

  • Kang, Nam-Yong;Yoon, Young-John;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.559-568
    • /
    • 1997
  • For orthodontic tooth movement, optimal orthodontic force should be maintained without periodontal breakdown and alveolar bone should be remodeled physiologically Therefore, To obtain proper occlusion through tooth movement within alveolar bone, we should know the biomechanics of teeth and supporting 4issues. The present study was performed to observe histologic changes of periodontal tissue immediately after application of orthodontic force and during the retention period in growing young adult dogs. In this study, experimental group contained between mandibular left canine and 1st molar and control group contained contralateral teeth of same animal. The .018'x.022' stainless steel closed coil spring(Dentaurum Co.) was ligated on the experimental teeth at initial 200gm-force from mandibular canine to 1st molar The animals(4 to 6 months aged young adult dogs) were sacrificed on 0, 14, 28 days after the finish of appliance activation, and then tissue samples were divided into hematoxylin-eosin(HE) staining section, ground section, alkaline phosphatase(ALP) staining section, and tartrate-resistant acid phosphatase(TRAP) staining section. Thereafter, the preparations were examined under light microscopy The following results were obtained: 1. Immediately after the finish of appliance activation, the periodontal space was increased in tension side, but decreased in pressure side compared to that of control. The hyalinized zone was also observed in the periodontium. 2. After the 14-day retention, peridontal space was decreased in tension side and slightly increased in pressure side compared to that of immediately after the finish of appliance activation. The hyalinized zone was repaired and a few osteoblasts showing slightly new bone formation were seen. Osteoblasts were scarcely observed along the alveolar bone. 3. Aftter the 28-day retention, the periodontal fibers are normally repaired. A lot of TRAP(+) osteoclasts md increased alveolar bone resorption were observed in pressure side, and AP(+) osteoblast and increased new bone formation were observed in tension side.

  • PDF