• Title/Summary/Keyword: H/D ratio

Search Result 2,217, Processing Time 0.034 seconds

A Study on the Thermal and Pollution Performances of the Heating Boilers with NG-H2 Mixture Ratio (난방용 보일러에서 NG-H2 혼소율에 따른 열 및 공해 성능의 검토)

  • SEO, JUNSUN;KIM, YOUNG-JIC;PARK, JUNKYU;LEE, CHANG-EON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.6
    • /
    • pp.573-584
    • /
    • 2021
  • Hydrogen is evaluated as one of the new energy sources that can overcome the limitations and pollution problems of conventional fossil fuels. Although hydrogen is CO2-free, attention is required in NOx emission and flame stability in order to use hydrogen in existing gas fuel system. However, use of electric grids is an unrealistic strategy for decarbonization for residential and commercial heating. Instead, use of H2 that utilizes city gas grid is suggested as a reasonable alternative in terms of compatibility with existing systems, economic feasibility, and accessibility. In this study, the thermal efficiency and NOx performance of the boiler according to the H2 mixture ratio and vapor humidified ratio are reviewed for a humidified NG-H2 boiler that vapor humidity to combustion air. Mixed fuel with H2 (20%) is almost similar to NG in terms of efficiency, flame temperature, and pollution performance. Thus, it is expected to be directly compatible with the existing NG system. If the exhaust temperature of the H2 boiler is lowered to around 60℃ at a humidified ratio of 15-20%, the NOx emission concentration can be suppressed to about 5-10 ppm. The level of efficiency reaches 87% of the rated load efficiency, which is equivalent to the highest grade achievable.

Studies on Suppositories of $Phenytoin-{\beta}-Cyclodextrin$ Inclusion Complexes (페니토인-${\beta}$-시클로덱스트린 포접 복합체의 좌제에 관한 연구)

  • Cha, Jae-Ho;Han, Kun
    • Journal of Pharmaceutical Investigation
    • /
    • v.18 no.1
    • /
    • pp.15-21
    • /
    • 1988
  • An inclusion complex of phenytoin (PT) with ${\beta}-cyclodextrin\;({\beta}-CyD)$ in molar ratio of 1 : 1 was prepared, and the interaction between host and guest molecules was confirmed by infrared spectrometry, differential scanning calorimetry and X-ray diffractometry. Suppositories were prepared by the fusion method. PT and $PT-{\beta}-CyD$ complex were added to PEG 1540 and Witepsol H-15 under the vigorous stirring at $40^{\circ}C$. Content uniformity was tested for different formulations of the PT suppositories. The release rates were dependent on the K.P. V dissolution apparatus and the dialyzing tubing method. Then, the release rates were increased in the following order: $PT-{\beta}-CyD$ complex in PEG 1540>PT in PEG 1540>$PT-{\beta}-CyD$ complex in Witepsol H-15>PT in Witepsol H-15. The area under the curve and maximum blood concentration after rectal administration were increased in the following order: $PT-{\beta}-CyD$ complex in PEG 1540>PT in PEG 1540>$PT-{\beta}-CyD$ complex in Witepsol H-15>PT in Witepsol-15.

  • PDF

Effect of Horizontal Pitch-to-Diameter Ratio on the Natural-Convection Heat Transfer of Two Staggered Cylinders (엇갈리게 배열된 두 개의 수평관에서 수평 피치-직경비에 따른 자연대류 열전달 영향)

  • Chae, Myeong-Seon;Heo, Jeong-Hwan;Chung, Bum-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.259-268
    • /
    • 2012
  • This study measured the natural-convection heat transfer of two vertically staggered cylinders with varying vertical pitch-to-diameter ($P_v$/D) and horizontal pitch-to-diameter ($P_h$/D) ratios. The measured heat-transfer rates for the lower cylinder agreed well with the existing heat-transfer correlations for a single cylinder. At the smallest $P_v$/D, the rising plume from the lower cylinder provides the upper cylinder with a preheated flow, and the heat-transfer rates of the upper cylinder decrease, but increase very sensitively with $P_h$/D. However, at the largest $P_v$/D, the velocity effect dominates, and the heat-transfer rates of the upper cylinder are larger than that of a single cylinder, and decrease less sensitively with $P_h$/D. Even if $P_h$/D is increased, the heat-transfer rate of the upper cylinder is higher than that of the lower cylinder because of the chimney and side flow effects. This work expanded the flow ranges to turbulent flows. The cupric acid-copper sulfate ($H_2SO_4-CuSO_4$) electroplating system was adopted for the measurements of the mass-transfer rates instead of the heat-transfer experiments based on the analogy concept. The measurements were made by varying $P_v$/D (1.02-5) and $P_h$/D (0-2) in both laminar and turbulent flows. The Rayleigh number ranged from $1.5{\times}10^8$ to $2.5{\times}10^{10}$, and the Prandtl number was 2,014.

Effect of Pile Construction on Lateral Behavior of Single Rigid Pile in Sand (사질토 지반에서 단일 강성말뚝의 수평거동에 대한 시공방법의 영향)

  • 김병탁;김영수;서인식
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.6
    • /
    • pp.29-44
    • /
    • 1999
  • This paper shows the results of model tests on the lateral behavior of single rigid pile, which was constructed by driving, in homogeneous and non-homogeneous (two layered) NakDong River sands. The purpose of the present paper is to investigate the effect of ratio of lower layer thickness to embedded pile length, relative density of sand and pile construction conditions (Driven & Embedded piles) on the characteristics of lateral behavior of single pile. These effects can be quantified only by the results of model tests. As a model result, the lateral behavior depends upon the pile construction condition in loose-density soil more than in high-density soil. If the pile construction depends upon driving construction, the decrease of deflection remarkably increases for both loose homogeneous sand and non-homogeneous soil$(E_{h1}/E_{h2}/=0.18)$ with high thickness of upper layer but the decrease of maximum bending moment shows the opposite result to the decrease of deflection. And, with respect to deflection, it was found that the deflection ratio $(y_{Driven}y_{Embedded})$ of embedded to driven piles has the ranges of 0.65 - 0.88 $(D_r=90%)$0.38 - 0.65 $(D_r=61.8%)$ for each relative density of homogeneous soil and the range of 0.6 - 0.88 for non-homogeneous soil. Also, in this study, the experimental equation for the effects of drop height (DH) and H/L on the ratios of $y_D/y_E\; and MBM_D/MBM_ E$ is suggested from model tests.

  • PDF

Evaluation of Effluent Toxicity which were Exempted from Applying of Ecotoxicity Criteria (생태독성기준 미적용 업종 사업장 배출수 생태독성 수준 평가)

  • Kim, Jongmin;Shin, Kisik;Lee, Soohyung;Lee, Jungseo;Lee, Taekjune
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.2
    • /
    • pp.197-202
    • /
    • 2017
  • This paper aimed to evaluate the test results of acute toxicity on effluent samples which were exempted from applying of ecotoxicity criteria. Total 316 effluent samples which were free from controlling of ecotoxicity regulation, were tested. Ratio of effluent samples which were exceeded the ecotoxicity criteria (TU > 1) indicated 23.7%. This ratio was a little bit higher than previous study (22.7%) on effluent samples which were controlled under ecotoxicity criteria. These results mean that our ecotoxicity management system is not appropriate and applying of ecotoxicity criteria to all effluent samples (82 industry categories) were needed in order to improve our ecotoxicity system. In addition, the same numeric criteria (TU 1 or 2) for all industry categories were proposed in consideration of these results. Ratio of effluent samples which exceeded the ecotoxicity criteria (TU > 1) with D. magna indicated 23.7%. However V. fischeri showed 14.6%. As a acute toxicity test organism, D. magna seemed to be more sensitive than V. fischeri. Ratio of samples which were exceeded TU 1 with D. magna by 24 h exposure period test indicated 35 %, whereas 48 h showed 41%.

Effects of oscillation parameters on aerodynamic behavior of a rectangular 5:1 cylinder near resonance frequency

  • Pengcheng Zou;Shuyang Cao;Jinxin Cao
    • Wind and Structures
    • /
    • v.38 no.1
    • /
    • pp.59-74
    • /
    • 2024
  • Large Eddy Simulation (LES) is used to explore the influence of vibration frequency and amplitude on the aerodynamic performance of a rectangular cylinder with an aspect ratio of B/D=5 (B: breadth; D: depth of cylinder) at a Reynolds number of 22,000 near resonance frequency. In smooth flow conditions, the research employs a sequence of three-dimensional simulations under forced vibration with diverse frequency ratios fe / fo = 0.8-1.2 (fe : oscillation frequency; fo : Strouhal frequency when the rectangular cylinder is stationary ) and oscillation amplitudes Ah/D = 0.05 - 0.3. The individual influences of fe / fo and Ah/D on the characteristics of integrated and distributed aerodynamic forces are the focal points of discussion. For the integrated aerodynamic force, particular emphasis is placed on the analysis of the dependence of velocity-proportional component C1 and displacement-proportional component C2 of unsteady aerodynamic force on amplitude and frequency ratio. Near the resonance frequency, the dependencies of C1 and C2 on amplitude are stronger than that of frequency ratio. For the distributed aerodynamic force, the increase in frequency and amplitude promotes the position of the main vortex core and reattachment to the leading edge in the streamwise direction. In the spanwise direction, vibration enhances the spanwise correlation of aerodynamic force to weaken the three-dimensional effect of the flow field, and a lower frequency ratio and larger amplitude amplify this effect.

Slaughterhouse wastewater treatment in a bamboo ring anaerobic fixed-bed reactor

  • Tritt, Wolfgang P.;Kang, Ho
    • Environmental Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.70-75
    • /
    • 2018
  • A pilot scale anaerobic fixed-bed with a reactor volume of $2.8m^3$ was built to treat slaughterhouse wastewater. Bamboo rings were chosen as support media mainly because of their cheaper price in underdeveloped countries. Even with their lower porosity and specific surface, the reactor performance showed a maximum 95% COD removal efficiency at an organic loading rate (OLR) of $1kg\;COD/m^3-d$ with its corresponding hydraulic retention time (HRT) of 7.5 d. At a higher OLR of $4.0kg\;COD/m^3-d$, the COD removal efficiency of 75% was achieved with an HRT of 2 d. No big difference in COD removal efficiencies was found between the reactors operated in both upflow and downflow modes. Their operational behavior and effluent characteristics were similar. The effluent COD/TKN ratio of 6.67 at an OLR of $4.0kg\;COD/m^3-d$ was only marginal acceptable range for a subsequent biological denitrification process. Otherwise carbon supplementation is required at a lower OLR.

Effect of Packing Density of ion-Exchange on the Nickel Adsorption Column in Electroplating Rinse Water (이온교환 칼럼 충진비의 변화가 도금폐수 중 니켈이온 흡착에 미치는 영향)

  • 황택성;이진혁
    • Polymer(Korea)
    • /
    • v.26 no.5
    • /
    • pp.551-558
    • /
    • 2002
  • It was observed that adsorption characteristics of sulfonated fabric ion-exchanger for separating nickel ion from electroplating rinse water. Swelling ratio was increased by increasing degree of sulfonation and polarity of solvent. Ion-exchange capacity was also increased by increasing degree of sulfonation and showed 3.38 meq/g at 16% sulfonated ion-exchanger. There was little effects of pH. Adsorption equilibrium was attained within 10 min, and adsorption rate was 7.5 mg/min. Adsorption capacity was not changed after 7 cycles of regeneration process. Regeneration adsorption capacity was slightly decreased to 2.01 meq/g. It confirmed that durability of sulfonated fabric ion-exchanger was suitable for adsorption process. Adsorption equilibrium time was linearly increased by increasing L/D and adsorption capacity showed the ion exchange capacity within the range of 2.71 ∼ 3.01 meq/g in continuous process. Design of adsorption column could be possible for L/D<2. Under constant L/D condition, there is no little pH effect when rinse water is acidic solution, and operation condition of adsorption process was optimized under pH 5.

Validity Examination on Evaluation of J-R Curve in the Nuclear Reactor Pressure Vessel Steels and Aluminum Alloys by Load Ratio Analysis (원자로 압력용기강 및 Al 합금재의 J-R곡선평가시 Load Ratio 해석의 유효성 검토)

  • Yoon, H.K.;Woo, D.H.;Kim, Y.K.;Cha, G.J.
    • Journal of Power System Engineering
    • /
    • v.1 no.1
    • /
    • pp.80-90
    • /
    • 1997
  • The purpose of this study is to evaluate the validity examination of the J-R curve characteristics for the nuclear reactor pressure vessel steels and Al alloys by the load ratio analysis. The results of the load ratio analysis are compared with those of the J-R curve which are obtained by the ASTM unloading compliance method. The crack length calculated by the load ratio analysis is agree well with the measured final crack length. The slope of the exponential J-R curve estimated by the load ratio analysis is slightly smaller than that by the ASTM unloading compliance method. The J-R curve obtained by the ASTM unloading compliance method is over-predicted and should be offsetted due to the initial negative crack. On the other hand, the load ratio analysis method can evaluate the J-R curve by only load-displacement curve without particular crack measurement equipment.

  • PDF