• Title/Summary/Keyword: H&S performance

Search Result 4,515, Processing Time 0.039 seconds

Observer-based H Fuzzy Controller Design of Interval Type-2 Takagi-Sugeno Fuzzy Systems Under Imperfect Premise Matching (불완전한 전반부 정합 하에서의 관측기 기반 구간 2형 T-S 퍼지 시스템의 H 퍼지 제어기 설계)

  • Hwang, Sounghwan;Park, Jin Bae;Joo, Young Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.11
    • /
    • pp.1620-1627
    • /
    • 2017
  • In this paper, we design an observer-based $H_{\infty}$ fuzzy controller for interval type-2 Takagi-Sugeno (T-S) fuzzy systems under imperfect premise matching. The designed observer-based controller can effectively estimate the state of the system and make fuzzy system satisfy the $H_{\infty}$ disturbance attenuation performance. Using the slack matrix, the derived stabilization condition is expressed in terms of a linear matrix inequality. Finally, the effectiveness of the proposed method is verified through a simulation example.

Reliable charge retention in nonvolatile memories with van der Waals heterostructures

  • Qiu, Dongri;Kim, Eun Kyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.282.1-282.1
    • /
    • 2016
  • The remarkable physical properties of two-dimensional (2D) semiconducting materials such as molybdenum disulfide ($MoS_2$) and tungsten disulfide ($WS_2$) etc. have attracted considerable attentions for future high-performance electronic and optoelectronic devices. The ongoing studies of $MoS_2$ based nonvolatile memories have been demonstrated by worldwide researchers. The opening hysteresis in transfer characteristics have been revealed by different charge confining layer, for instance, few-layer graphene, $MoS_2$, metallic nanocrystal, hafnium oxide, and guanine. However, limited works built their nonvolatile memories using entirely of assembled 2D crystals. This is important in aspect view of large-scale manufacture and vertical integration for future memory device engineering. We report $WS_2$ based nonvolatile memories utilizing functional van der Waals heterostructure in which multi-layered graphene is encapsulated between $SiO_2$ and hexagonal boron nitride (hBN). We experimentally observed that, large memory window (20 V) allows to reveal high on-/off-state ratio (>$10^3$). Moreover, the devices manifest perfect retention of 13% charge loss after 10 years due to large graphene/hBN barrier height. Interestingly, the performance of our memories is drastically better than ever published work related to $MoS_2$ and black phosphorus flash memory technology.

  • PDF

A study on the Application of STS wire Mesh air Cleaner for the 2-Wheel Automotive (2륜 자동차 공기청정기의 STS적용에 관한 연구)

  • Yi, C.S.;Lee, Y.H.;Suh, J.S.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.6 no.4
    • /
    • pp.30-35
    • /
    • 2002
  • This study represents the effects of the material of the air cleaner on the performance in a 4-stroke spark-ignition engine for motorcycles. This study is mainly focused on the possibility of the adopting the STS wire mesh air cleaner of a S.I engine. For investigating the possibility of that, the engine power, the fuel consumption and the exhaust gas analysis were carried out for the synthetic fiber air cleaner and the different size of 200 mesh, 250 mesh, 300 mesh of STS wire mash air cleaner. As the results of this study, the performance of STS wire air cleaner was similar to the fiber air cleaner at 9000 rpm but 300 mesh of STS air cleaner had a high engine power and torque at 9500 rpm. In the case of the synthetic fiber air cleaner the concentration of CO was low at 6500 rpm and in the case of the 300 mesh in STS wire mesh air cleaner the concentration of HC was lowest at all experimental regions.

  • PDF

A Development of Diagnosis Expert System for Power System Protective Relay Settings (보호계전기 정정값 진단 전문가 시스템 개발)

  • Kim, K.J.;Lee, S.J.;Choi, M.S.;Kang, S.H.;Kim, H.P.;Lee, W.H.;Choi, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1394-1396
    • /
    • 1999
  • It is important the protective relay should have high selectivity and sensitivity performance and it is achieved by correct setting of the relay parametes. The verification of accurate setting for the protective relay is very difficult before a actual fault occurs. This paper reports a diagnosis expert system to verify the correctness of the relay setting by using the operation results in the power system fault simulation.

  • PDF

A Development of Protective Relay Operating-Diagnosis System for Power System (송전계통 선로보호 계전기 동작 진단 시스템)

  • Kim, K.J.;Lee, S.J.;Choi, M.S.;Kang, S.H.;Kim, H.P.;Lee, W.H.;Choi, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.107-109
    • /
    • 1999
  • In the point of view protective relay, the selectivity and sensitivity is very important in its performance. The correct setting of the relay parameter is required. The verification of accurate setting for the protective relay is very difficult before a actual fault occurs. In this paper, we proposed the diagnosis expert system as a method to verify the correctness of the relay setting. The developed system proved effectiveness through the tests on the real systems.

  • PDF

Study on performance prediction of centrifugal compressor with diffuser angle and rotational speed change (원심압축기의 디퓨져 각도조절과 회전수변경에 따른 성능예측에 관한 연구)

  • Park, Y.H.;Shim, Y.H.;Kim, C.S.;Cho, S.Y.
    • Journal of Power System Engineering
    • /
    • v.16 no.5
    • /
    • pp.55-62
    • /
    • 2012
  • Centrifugal compressors are widely used and each operating condition is different. However, it cannot be manufactured according to the every operating condition. In the this study, performance of compressor was evaluated with various rotational speeds of impeller and various stagger angles of diffuser in order to apply a typical model widely. A centrifugal compressor was designed and manufactured based on the design point. On this machines, an experiment was conducted and the performance was predicted at off-design point. The performance prediction was validated with the experimental result and the numerical result. Although the isentropic efficiency on the prediction was slightly lower than that on the experimental result due to the heat loss in the experiment, the pressure ratio was predicted well and also the predicted results were matched well with the numerical results. When the rotational speed of the impeller and the stagger angle of the diffuser were changed together, the compressor can be worked in the high efficiency region and avoided operating in the stall region.

Effects of Gestational Housing on Reproductive Performance and Behavior of Sows with Different Backfat Thickness

  • Kim, K.H.;Hosseindoust, A.;Ingale, S.L.;Lee, S.H.;Noh, H.S.;Choi, Y.H.;Jeon, S.M.;Kim, Y.H.;Chae, B.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.1
    • /
    • pp.142-148
    • /
    • 2016
  • The present study investigated the effects of back-fat thickness at d 107 of gestation and housing types during gestation on reproductive performance and behavior of sows. A total of 64 crossbred sows ($Landrace{\times}Yorkshire$) in their 3 to 4 parities were allotted to one of four treatments (n = 16) over two consecutive parities. During each parity, sows were assigned to two gestational housing types (stall or group housing) and two level of back-fat thickness (<20 or ${\geq}20$) at d 107 of gestation. Gestating sows were transferred from gestational crates to stalls or pens (group housing) 5 weeks before farrowing. All sows were moved to farrowing crates on d 109 of gestation. At weaning, back-fat thickness changes were lesser (p<0.05) in sows having back-fat thickness <20 mm than that of sows with ${\geq}20mm$ back-fat thickness at 107 d of gestation. Group housed sows had greater (p<0.05) feed intake and shorter (p<0.05) weaning-to-estrus interval than that of sows in stalls. At weaning, back-fat thickness changes were lesser (p<0.05) in group housed sows than that of sows in stalls. The number of piglets at weaning, growth rate and average daily gain were greater (p<0.05) in group housed sows than that of sows in stalls. During gestation, walking duration was more (p<0.05) in group housed sows. Group housed sows had lesser (p<0.05) farrowing duration and greater (p<0.05) eating time than that of sows in stalls. Result obtained in present study indicated that sows with ${\geq}20mm$ back-fat thickness at 107 days had better reproductive performance. Additionally, group housing of sows during last five week of gestation improved the performance and behavior and reproductive efficiency of sows.