• 제목/요약/키워드: H&S performance

검색결과 4,501건 처리시간 0.04초

FE 해석을 통한 충격흡수시설의 개발 (Development for Shock Absorption System by Using FE Analysis)

  • 강영호;김홍주;박동화;김계수;강범수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.224-229
    • /
    • 2000
  • This paper describe a (mite element computer simulation of a absorption system using full scale car crash test. The full scale test selected for this study is a 80kmh frontal, side and 25% offset impact of a 1993 Ford Taurus vehicle into a absorption system. This absorption system has external rubber and internal steel pannel. This simulation has completed for decision of these components energy absorption performance. Dynamical performance of this system and movement are obtained from this simulation. and then We can appreciate the safety of passenger from measure the vehicle C.G's acceleration.

  • PDF

4kW 태양광 발전용 PCS 개발 (Development of the 4kW Photovoltaic Power Conditioning System)

  • 이현두;박영호;전세봉;김종규;류승표;이세현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.291-292
    • /
    • 2010
  • The main purpose of this study is to design and develop the grid connected 4kW photovoltatic PCS(Power Conditioning System) targeting for Japanese market. To make this task, the development of DC to DC converter, one phase inverter and EMI filters, and the research on connection between inverter and utility line are made. The developed 4kW PCS has fully carried out performance verifications and evaluation works and acquired the JET(Japan Electrical Safety & Environment Technology Laboratories) certification for safety and performance.

  • PDF

도로/궤도 매립형 무접촉 집전장치의 전력전달 성능 개선을 위한 특성해석 (Characteristic analysis of inductive contactless power transformer used for the road/railway to improve the performance.)

  • 한경희;백수현;이병송;배창한;변윤섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1304-1306
    • /
    • 2004
  • Recently, the study for development of system having affinity for environment is on investigation. This issue is also applicable to transportation system. This paper suggested the inductive power transformer used for the road/railway applied to contactless power transfer system. The two secondary windings, large gaped magnetic structure and horizontal alignment between primary and secondary coil for that transformer approach a process for improvement of contactless power transfer system performance.

  • PDF

A Teleoperated Bilateral Control System for Heavy Duty Tasks

  • S.H. Ahn;Kim, S.H.;D.H. Hong;J.S. Yoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.155.2-155
    • /
    • 2001
  • A heavy duty power manipulator consisting of high reduction ratio joints is usually used in heavy duty tasks. When the heavy duty power manipulator is used as the slave manipulator in the teleoperated bilateral control system, the position control performance of the slave manipulator and the system stability tend to deteriorate due to the windup phenomenon caused by actuator saturation. KAERI has developed a teleoperated bilateral control system for the study of the remote handling of a spent fuel mockup bundle, which has an enhanced bilateral control algorithm improving the position tracking performance of the slave manipulator while compensating for the windup phenomenon. In this paper, the developed bilateral control system ...

  • PDF

재하된 H형강 휨재의 열응력해석을 이용한 한계온도 산정 (Calculation of Limit Temperature on H-Beam Flexural Member Through the Thermal Stress Analysis under the Lateral Load)

  • 윤성기;이치형;구본훈
    • 한국강구조학회 논문집
    • /
    • 제27권4호
    • /
    • pp.387-397
    • /
    • 2015
  • 국내의 내화성능평가는 대부분 사양적설계 방법인 품질시험을 통해 이뤄지고 있다. 하지만 시험 특성상 많은 비용과 시간을 요구하며 다양한 건축구조에 대한 내화성능평가에는 어려움이 많다. 따라서 본연구에서는 성능적 설계를 위한 연구로 유한요소 구조해석 프로그램인 ABAQUS를 사용해 H형강 휨재를 대상으로 변수에 따른 열응력 해석을 통해 내화성능을 검토하며, 하중비별 한계온도를 제안한다.

Bioscrubber와 Biofilter 병합 시스템에 의한 H2S 제거특성 ([ H2S ] Removal Characteristics by Combined System of Bioscrubber and Biofilter)

  • 빈정인;이병헌;감상규;이민규
    • 한국환경과학회지
    • /
    • 제16권6호
    • /
    • pp.763-769
    • /
    • 2007
  • This study compared the performance of a bioscrubber, a biofilter, and a combined system of bioscrubber and biofilter employed being operated at the laboratory-scale. for the removal of hydrogen sulfide. The bioscrubber maintained 100% removal of hydrogen sulfide up to inlet load of $56\;g-S/m^3{\cdot}hr$, while the removal efficiency was decreased with the increase of inlet load. The biofilter showed 100% removal efficiency up to inlet load of $126\;g-S/m^3{\cdot}h$ and the maximum elimination capacity of $126\;g\;S/m^3{\cdot}h$ for the inlet load of $224\;g-S/m^3{\cdot}h$. On the other hand, the combined system of bioscrubber and biofilter showed 100% removal for an inlet hydrogen sulfide load of up to $85\;g-S/m^3{\cdot}h$ and the maximum elimination capacity of $153\;g-S/m^3{\cdot}h$ for inlet loads of $224\;g-S/m^3{\cdot}h$.