• 제목/요약/키워드: Gust response

검색결과 67건 처리시간 0.021초

Analysis and performance of offshore platforms in hurricanes

  • Kareem, Ahsan;Kijewski, Tracy;Smith, Charles E.
    • Wind and Structures
    • /
    • 제2권1호
    • /
    • pp.1-23
    • /
    • 1999
  • Wind effects are critical considerations in the design of topside structures, overall structural systems, or both, depending on the water depth and type of offshore platform. The reliable design of these facilities for oil fields in regions of hostile environment can only be assured through better understanding of the environmental load effects and enhanced response prediction capabilities. This paper summarizes the analysis and performance of offshore platforms under extreme wind loads, including the quantification of wind load effects with focus on wind field characteristics, steady and unsteady loads, gust loading factors, application of wind tunnel tests, and the provisions of the American Petroleum Institute Recommended Practice 2A - Working Stress Design (API RP 2A-WSD) for the construction of offshore structures under the action of wind. A survey of the performance of platforms and satellite structures is provided, and failure mechanisms concerning different damage scenarios during Hurricane Andrew are examined. Guidelines and provisions for improving analysis and design of structures are addressed.

The 2021 Australian/New Zealand Standard, AS/NZS 1170.2:2021

  • John D. Holmes;Richard G.J. Flay;John D. Ginger;Matthew Mason;Antonios Rofail;Graeme S. Wood
    • Wind and Structures
    • /
    • 제37권2호
    • /
    • pp.95-104
    • /
    • 2023
  • The latest revision of AS/NZS 1170.2 incorporates some new research and knowledge on strong winds, climate change, and shape factors for new structures of interest such as solar panels. Unlike most other jurisdictions, Australia and New Zealand covers a vast area of land, a latitude range from 11° to 47°S climatic zones from tropical to cold temperate, and virtually every type of extreme wind event. The latter includes gales from synoptic-scale depressions, severe convectively-driven downdrafts from thunderstorms, tropical cyclones, downslope winds, and tornadoes. All except tornadoes are now covered within AS/NZS 1170.2. The paper describes the main features of the 2021 edition with emphasis on the new content, including the changes in the regional boundaries, regional wind speeds, terrain-height, topographic and direction multipliers. A new 'climate change multiplier' has been included, and the gust and turbulence profiles for over-water winds have been revised. Amongst the changes to the provisions for shape factors, values are provided for ground-mounted solar panels, and new data are provided for curved roofs. New methods have been given for dynamic response factors for poles and masts, and advice given for acceleration calculations for high-rise buildings and other dynamically wind-sensitive structures.

Wind-excited stochastic vibration of long-span bridge considering wind field parameters during typhoon landfall

  • Ge, Yaojun;Zhao, Lin
    • Wind and Structures
    • /
    • 제19권4호
    • /
    • pp.421-441
    • /
    • 2014
  • With the assistance of typhoon field data at aerial elevation level observed by meteorological satellites and wind velocity and direction records nearby the ground gathered in Guangzhou Weather Station between 1985 and 2001, some key wind field parameters under typhoon climate in Guangzhou region were calibrated based on Monte-Carlo stochastic algorithm and Meng's typhoon numerical model. By using Peak Over Threshold method (POT) and Generalized Pareto Distribution (GPD), Wind field characteristics during typhoons for various return periods in several typical engineering fields were predicted, showing that some distribution rules in relation to gradient height of atmosphere boundary layer, power-law component of wind profile, gust factor and extreme wind velocity at 1-3s time interval are obviously different from corresponding items in Chinese wind load Codes. In order to evaluate the influence of typhoon field parameters on long-span flexible bridges, 1:100 reduced-scale wind field of type B terrain was reillustrated under typhoon and normal conditions utilizing passive turbulence generators in TJ-3 wind tunnel, and wind-induced performance tests of aero-elastic model of long-span Guangzhou Xinguang arch bridge were carried out as well. Furthermore, aerodynamic admittance function about lattice cross section in mid-span arch lib under the condition of higher turbulence intensity of typhoon field was identified via using high-frequency force-measured balance. Based on identified aerodynamic admittance expressions, Wind-induced stochastic vibration of Xinguang arch bridge under typhoon and normal climates was calculated and compared, considering structural geometrical non-linearity, stochastic wind attack angle effects, etc. Thus, the aerodynamic response characteristics under typhoon and normal conditions can be illustrated and checked, which are of satisfactory response results for different oncoming wind velocities with resemblance to those wind tunnel testing data under the two types of climate modes.

Characteristics of thunderstorms relevant to the wind loading of structures

  • Solari, Giovanni;Burlando, Massimiliano;De Gaetano, Patrizia;Repetto, Maria Pia
    • Wind and Structures
    • /
    • 제20권6호
    • /
    • pp.763-791
    • /
    • 2015
  • "Wind and Ports" is a European project that has been carried out since 2009 to handle wind forecast in port areas through an integrated system made up of an extensive in-situ wind monitoring network, the numerical simulation of wind fields, the statistical analysis of wind climate, and algorithms for medium-term (1-3 days) and short term (0.5-2 hours) wind forecasting. The in-situ wind monitoring network, currently made up of 22 ultrasonic anemometers, provides a unique opportunity for detecting high resolution thunderstorm records and studying their dominant characteristics relevant to wind engineering with special concern for wind actions on structures. In such a framework, the wind velocity of thunderstorms is firstly decomposed into the sum of a slowly-varying mean part plus a residual fluctuation dealt with as a non-stationary random process. The fluctuation, in turn, is expressed as the product of its slowly-varying standard deviation by a reduced turbulence component dealt with as a rapidly-varying stationary Gaussian random process with zero mean and unit standard deviation. The extraction of the mean part of the wind velocity is carried out through a moving average filter, and the effect of the moving average period on the statistical properties of the decomposed signals is evaluated. Among other aspects, special attention is given to the thunderstorm duration, the turbulence intensity, the power spectral density and the integral length scale. Some noteworthy wind velocity ratios that play a crucial role in the thunderstorm loading and response of structures are also analyzed.

초고층 건축물 외벽 청소로봇 운용을 위한 가이드레일 개념(안) 개발 (Conceptual design development of Guide Rail for Cleaning Robot in Curtain Wall Facade of Skyscraper)

  • 김창한;한재구;김균태
    • 한국건축시공학회지
    • /
    • 제12권2호
    • /
    • pp.220-229
    • /
    • 2012
  • 매년 초고층 건축물 관련 프로젝트가 증가하고 있으며, 초고층 건축물의 높이가 증가함에 따라 시공법과 함께 유지관리 방법도 기존방식과는 큰 차이를 보이고 있다. 또한 유지관리 업무 중 가장 빈번하게 수행되는 외벽 청소작업을 보다 안전하게 작업하기 위한 근본적인 대책으로 청소작업의 자동화 및 기계화가 요구되고 있다. 그리고 초고층에서 발생되는 돌풍 등 외부환경의 영향에 대응할 수 있는 방법으로 가이드레일 청소로봇 시스템이 제기되고 있다. 따라서 본 연구는 초고층 건축물 외벽 청소작업의 자동화 및 기계화를 위한 선행연구로써, 외벽 청소로봇 운용을 위한 가이드레일 기본단위유닛 도출과 가이드레일 개념(안)을 개발하는 것이다. 이를 통하여 초고층 건축물 외벽 청소로봇운용을 위한 선행연구이며, 운용에 필요한 최적의 가이드레일 최종설계의 기반을 마련하고자 한다.

Wind-induced responses and dynamic characteristics of a super-tall building under a typhoon event

  • Hua, X.G.;Xu, K.;Wang, Y.W.;Wen, Q.;Chen, Z.Q.
    • Smart Structures and Systems
    • /
    • 제25권1호
    • /
    • pp.81-96
    • /
    • 2020
  • Wind measurements were made on the Canton Tower at a height of 461 m above ground during the Typhoon Vincente, the wind-induced accelerations and displacements of the tower were recorded as well. Comparisons of measured wind parameters at upper level of atmospheric boundary layer with those adopted in wind tunnel testing were presented. The measured turbulence intensity can be smaller than the design value, indicating that the wind tunnel testing may underestimate the crosswind structural responses for certain lock-in velocity range of vortex shedding. Analyses of peak factors and power spectral density for acceleration response shows that the crosswind responses are a combination of gust-induced buffeting and vortex-induced vibrations in the certain range of wind directions. The identified modal frequencies and mode shapes from acceleration data are found to be in good agreement with existing experimental results and the prediction from the finite element model. The damping ratios increase with amplitude of vibration or equivalently wind velocity which may be attributed to aerodynamic damping. In addition, the natural frequencies determined from the measured displacement are very close to those determined from the acceleration data for the first two modes. Finally, the relation between displacement responses and wind speed/direction was investigated.

실측 데이터를 이용한 공용중인 강사장교의 버페팅 응답 분석 (A Study on Buffeting Responses of a In-service Steel Cable-stayed Bridge Using Full-scale Measurements)

  • 이덕근;공민준;유동우
    • 대한토목학회논문집
    • /
    • 제36권3호
    • /
    • pp.349-359
    • /
    • 2016
  • 공용 중인 교량의 버페팅 응답을 해석적으로 평가하기 위해서는 교량 현장의 난류강도, 난류 스펙트럼, 조도계수, 거스트 계수 등 풍하중에 대한 분석이 우선되어야 하고, 해석 결과는 정적 공기력 계수, 플러터계수, 구조 감쇠비, 공기역학적 감쇠비, 고유 진동수 등 여러 변수에 의해 영향을 받는다. 본 논문에서 대상으로 한 교량은 32년째 공용 중에 있는 교량으로써 교량 주변의 지형조건은 설계 및 시공 당시에 비해 많은 변화가 발생하였으며 최근 기후 변화로 인한 풍 환경 역시 큰 변화가 있다. 이러한 이유로 대상교량에서 실측한 풍속 데이터를 분석하여 난류강도, 난류길이, 지표조도계수, 풍속 스펙트럼 등 교량 현장의 풍하중을 평가하였다. 교량 주변의 풍환경 평가 결과, 대상 교량은 해상교량임에도 불구하고 지표조도구분 II의 특성을 나타내고 있었다. 또한 실측한 구조물의 가속도, 변위 응답 데이터를 통해 대상교량의 감쇠비, 정적 공기력 계수, 고유진동수를 평가하여 계측기반 버페팅 해석 변수를 산정하였다. 계측데이터 기반의 해석 변수와 케이블강교량설계지침에 제시된 해석 변수를 적용하여 총 4가지 경우에 대한 버페팅 해석을 수행하였으며, 그 결과 10분 평균 풍속 25m/s이하에서 측정된 버페팅 응답과 계측 기반 해석 변수를 적용한 해석 응답이 가장 잘 일치함을 확인하였고, 계측 풍속과 Gumbel 확률분포를 이용하여 추정한 200년 재현기대 풍속인 45m/s에서의 버페팅 응답을 제시하였다.