Gas Sensing Characteristics and Doping Effect of $MoO_3$ Thin Films prepared by RF magnetron sputtering (RF magnetron sputtering법으로 제조한 $MoO_3$ 박막의 가스 감지 특성 및 첨가물의 영향)

  • Hwang, Jong-Taek;Jang, Gun-Eik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.460-463
    • /
    • 2002
  • $MoO_3$ thin films were deposited on electrode and heater screen-printed alumina substrates in $O_2$ atmosphere by RF reactive sputtering using Molybdenum metal target. The deposition was performed at $300^{\circ}C$ with 350W of a forward power in an $Ar-O_2$ atmosphere. The working pressure was maintained at $3{\times}10^{-2}mtorr$ and all deposited films were annealed at $500^{\circ}C$ for 5hours. To investigate gas sensing characteristics of the addition doped $MoO_3$ thin film, Co, Ni and Pt were used as adding dopants. The sensing properties were investigated in tenn of gas concentration under exposure of reducing gases such as $H_2$, $NH_3$ and CO at optimum working temperature. Co-doped $MoO_3$ thin film shows the maximum 46.8% of sensitivity in $NH_3$ and Ni-doped $MoO_3$ thin film exhibits 49.7% of sensitivity in $H_2$.

  • PDF

Hydrox Generator for Steel Manufacturing (철강재료 가공용 수산소 혼합가스 발생기)

  • Kim, Hong-Gun;Kwac, Lee-Ku;Lee, Woo-Gum;Cha, Hwa-Dong;Shin, Jooung-Dal
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.3
    • /
    • pp.257-262
    • /
    • 2011
  • A low capacity generator converted to high capacity of 40m3 is designed and developed in order to use the hydroxy gas in the steel manufacturing process. For efficient design, it is increased from 8 electrode tubes to 10 electrode tubes as well as expanding the diameter of cell integument up to two times bigger, which can increase the amount of hydrogen occurrence per a cell significantly. In addition, circulating pump and pipe, heat exchanger of affiliated SUS material have been used in the circulation of electrolysis catalyst, and circulating cooling section and piping design are also developed. The flame trap is designed into all-in-one suitable check valve in the flow rate of 28-35m3/h and its application is possibly applied in work operation. It is found that the efficiency of generator developed is enhanced substantially up to 84%. It is expected that the application in this field can be expanded significantly by this study.

Fabrication and Characteristic of NOx Gas Sensor by Using $SnO_2$ Nanowires ($SnO_2$ 나노와이어를 이용한 NOx 가스센서 제작 및 특성평가)

  • Kang, Gyo-Sung;Kwon, Soon-Il;Park, Jea-Hwan;Yang, Kea-Joon;Lim, Dong-Gun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.40-41
    • /
    • 2007
  • $SnO_2$ nanowires are used at the nanoscale level for the electrical transduction of the gas interaction with these sensing materials. We report on a study of high sensitivity and fast NOx gas sensor. We focused on improving the response time and refresh time by growth nanowires on the trench structure of Si substrate as air path. To improve refresh time we applied the trench structure with depth of $10\;{\mu}m$ by the inductively coupled plasma reactive ion etching(ICP-RIE). The fabricated device was measured at temperature of $200{\sim}300^{\circ}C$. The sensor exhibit ultra-fast and reversible electrical response (t90% ~4 s for response and ~3 s for recovery).

  • PDF

SBLOCA AND LOFW EXPERIMENTS IN A SCALED-DOWN IET FACILITY OF REX-10 REACTOR

  • Lee, Yeon-Gun;Park, Il-Woong;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.45 no.3
    • /
    • pp.347-360
    • /
    • 2013
  • This paper presents an experimental investigation of the small-break loss-of-coolant accident (SBLOCA) and the loss-of-feedwater accident (LOFW) in a scaled integral test facility of REX-10. REX-10 is a small integral-type PWR in which the coolant flow is driven by natural circulation, and the RCS is pressurized by the steam-gas pressurizer. The postulated accidents of REX-10 include the system depressurization initiated by the break of a nitrogen injection line connected to the steam-gas pressurizer and the complete loss of normal feedwater flow by the malfunction of control systems. The integral effect tests on SBLOCA and LOFW are conducted at the REX-10 Test Facility (RTF), a full-height full-pressure facility with reduced power by 1/50. The SBLOCA experiment is initiated by opening a flow passage out of the pressurizer vessel, and the LOFW experiment begins with the termination of the feedwater supply into the helical-coil steam generator. The experimental results reveal that the RTF can assure sufficient cooldown capability with the simulated PRHRS flow during these DBAs. In particular, the RTF exhibits faster pressurization during the LOFW test when employing the steam-gas pressurizer than the steam pressurizer. This experimental study can provide unique data to validate the thermal-hydraulic analysis code for REX-10.

Results of a Round-Robin Test for the Draft International Standard on FT-IR Gas Analysis of Fire Effluents from a Cone Calorimeter (콘칼로리미터 연소가스 FT-IR 분석을 위한 국제표준 초안의 비교시험 결과분석)

  • Choi, Jung-Min;Park, Kye-Won;Jeong, Jae-Gun
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.1-8
    • /
    • 2019
  • The international standard for FT-IR gas analysis of fire effluents in ISO 5660-1 cone calorimeter has been being developed in ISO TC 92. A comparison of the round-robin test of WD 21397 was conducted with six participating laboratories in 2018. The test specimens were PMMA, rigid PU foam board, and PVC flooring. The measurement quantities were the time-to-ignition, peak heat release rate, total heat release, and effective heat of combustion for a cone calorimeter test and peak gas concentration, gas generation, and gas yield for FT-IR gas analysis. No outliers were identified. For the cone calorimeter quantities, the repeatability and reproducibility were 1.5% and 9.8%, respectively. For FT-IR gas analysis, the repeatability and reproducibility was 12.9% and 27.9%, respectively.

The research on CFD turbulance models for comparison according to my secondary air injection into the combustion (연소로 내 2차 공기 분사에 따른 CFD 난류 모델 비교에 관한 연구)

  • Choi, Junhyuk;Choi, Chong-gun;Hwang, Seung-Sik;Shin, Donghoon;Chung, Tae-Yong
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.345-347
    • /
    • 2012
  • The secondary air injection influences the flow of the combustion gas in the furnace. Therefore, the analysis of the furnace should be careful in the selection of the turbulent model with CFD. In this study, CFD results of several turbulent models were compared with experimental results. Analysis results suggest to select turbulent models in the furnace secondary air nozzle.

  • PDF

自動車 分野에서의 熔接技術 應用現況

  • 박황호
    • Journal of Welding and Joining
    • /
    • v.10 no.4
    • /
    • pp.107-116
    • /
    • 1992
  • 자동차 공업에서의 용접은 주로 차체조립공정에서 많은 사용되고 있으며 전기저항용접, ARC 용접, GAS용접등이 쓰이고 있지만 특히 전기저항용접의 SPOT WELDING이 그 대부분을 차 지하고 있다. 자사의 경우 AUTO GUN이나 ROBOT의 적용으로 차종에 따라 자동화가 거의 90%에 이르며 이 수치는 향후 더욱 증가 되리라 본다. 최근의 연비향상을 위한 경량화와 장 기방청성 요구추세에 따른 새로운 소재 즉 Al, 2층도금강판등의 채택에 따라 자사실정에 맞는 적합한 용접기술개발이 필요하다. 본론에서는 점용접의 검사 방법과 검사기준, 용접 신뢰성 확 보를 위한 제시도와 신소재 적용에 대응한 개발의 필요성, 용접 자동화등의 현황들을 자사를 중심으로 실례를 들어 소개하고자 한다.

  • PDF

Experiments on Development A Pulse-Gun Pressure-Wave Inducing Device for Stability Rating Test Technique (연소안정성 평가시험 기법을 위한 펄스건 압력파 유도장치 개발 실험)

  • Lee, Kwang-Jin;Kim, Hong-Jip;Seo, Seong-Hyeon;Moon, Il-Yoon;Kim, Hyung-Mo;Lee, Soo-Yong;Ko, Young-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.99-106
    • /
    • 2005
  • The SRT(stability rating test) technique, which is indispensable for the development of a LRE(liquid rocket engine), essentially requires a development of a combustion test sequence as well as artificial perturbation devices. For the development of an indigenous SRT technique, several combustion tests of sub-scale LRE were performed to search a proper combustion test sequence. At first, a pressure-wave inducing device which is used for adapting pulse gun was designed and a cooling gas supply system for the pressure-wave inducing device was set up to prevent a malfunction of pulse gun. Through the several combustion tests which included cooling procedure of a pressure-wave inducing device, a proper combustion test sequence was found out. It did not make any significant disturbance at normal combustion process. Finally, an indigenous SRT technique has been developed successfully.

The study of direct ${\mu}c$-Si:H film growth using RPCVD system in low temperature (RPCVD system을 이용한 ${\mu}c$-Si:H의 저온 직접 성장 연구)

  • Ahn, Byeong-Jae;Kim, Do-Young;Lim, Dong-Gun;Yi, Jun-Sin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1818-1820
    • /
    • 1999
  • This paper presents direct ${\mu}c$-Si:H thin film growth on the glass substrates using RPCVD system (remote plasma chemical vapor deposition) in low temperature. Hydrogenated micro-crystalline silicon deposited by RPCVD system in low temperature is very useful material for photovoltaic devices, sensor applications, and TFTs (thin film transistors). Varying the deposition conditions such as substrate temperature, gas flow rate, reactive gas ratio $(SiH_4/H_2)$, total chamber pressure, and rf power, we deposited ${\mu}c$-Si:H thin films on the glass substrates (Corning glass 1737). And then we measured the structural and electrical properties of the films.

  • PDF

A Study on Measuring of Fire Extinguishing Concentration for Organic Material Using Novec (노벡을 이용한 유기물의 소화농도 측정에 관한 연구)

  • Lim, Woo-Sub;SaKong, Seong-Ho;Jung, Jong-Jin;Nam, Dong-Gun;Choi, Kenu-Joo;An, Sang-Su;Kim, Jong-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.456-460
    • /
    • 2008
  • This study was on basic step to develop a good clean extinguishing agent. In order to get a satisfactory result, we tested fire extinguishing ability using Novec which is inert gas. In study used to Cup Burner Test its made by international standard ISO-14520 regulations of gaseous extinguishing agent ability test. The finding is that a new clean agent, Novec has a very efficient extinguishing ability in a state of gas.

  • PDF