Study on Guideline of Water Supply System for Forest Fire (산불방지 급수시설 설치 기준 마련에 관한 연구)

  • Kim, Dong-Hyun;Nam, Song-Hee;Keum, Si-Hoon
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.38-46
    • /
    • 2013
  • Permanent water supply and water sprinkling systems are essential to protect major forests and facilities from forest fire. Back in 2005, Naksan Temple, a valuable cultural asset of Korea, was burned down in a forest fire that took place in Yangyang. This started a series of movements including installing water supply facilities and managing forests near important cultural assets. As for the existing facilities, however, they were installed without any standard guidelines for management and installation according to each constructor's specifications, which were based on the National Fire Safety Code 109. Unfortunately, this is not effective in protecting facilities from forest fires such as they have a small protection area, limited simultaneous sprinkling, and a difficult the movement of fire hose. Against this background, the study examines the condition of water supply facilities currently in use, identifies their deficiencies, and suggests how to improve the criteria for water supply service to effectively prevent forest fire. Specifically, three systems were proposed: Water Sprinkler Tower System for preventing spread of crown fires, and Forest Fire Hydrant System and Portable Water Spray System to be effective for suppressing surface fires. In addition, the standards on the performance and components of water pumps are also suggested.

A Study on Civil and Criminal Liabilities of 119 Rescue and Its Legal Protection (공무원인 119구급대원의 직무수행과 관련하여 발생할 수 있는 민$\cdot$형사상 책임과 그에 따른 법적 보호를 위한 대책에 관한 연구)

  • Bae Hyun-A;Yun Soon-Young;Jung Koo-Young;Lee Kyung-Whan;Kim Chan-Woong
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.45-62
    • /
    • 2005
  • This thesis has defined the legal status of 119 rescue who plays a major role in the Korean prehospital emergency medical system and reviewed the various issues that may occur depending on work related legal liabilities. As a result, the purpose of this study was to represent the countermeasures for legal protection of 119 rescue required for the quality improvement of prehospital emergency medical system and as well as the countermeasures for risk management prepared for its related lawsuits. The legal liabilities of 119 rescue officers can be divided largely into public law liabilities and civil and criminal liabilities. In order to decrease the incidences of legal problems and provide the legal protection to rescue officers, the liability of supervising physician should be emphasized when the emergency medical practice is performed by a rescue officer under their supervision by consolidating medical control and the rescue officer should have legal liability on his emergency medical practice. itself Also, the emergency medical service guideline for 119 rescue officers should be prepared and their works should be performed according to such a guideline and procedures. In addition, the accurate legal documentation on emergency medical system from on-site to ER and related mobilization should be framed and preserved. Moreover, it is required to enact a new law such as the Good Samaritan Act or the Rescue Officers Protection Act.

The Proposition of Domestic Sprinklers Installation Standard and the Fire Services Act (국내 스프링클러 설치기준과 소방관련 법에 관한 고찰)

  • Kim, Yong-Moon;Lee, Young-Jai
    • Journal of Korean Society of Disaster and Security
    • /
    • v.7 no.2
    • /
    • pp.17-24
    • /
    • 2014
  • Recently, many accidents occur frequently because sprinklers aren't installed or don't work right when there are outbreak of fire in houses and aggregate buildings. Therefore, they can result in damage for humans and loss of property. Sprinklers are the most appropriate which can extinguish buildings' fire in the initial stages. Through lack of legal system, in domestic cases, sprinklers cannot operate their inherent performance. Domestic standard simply classifies installation objects according to types of business and forms of buildings, also divides into uses and floors of buildings. Especially it only regulates that sprinklers must be installed every floors in particular fire buildings that have more than eleven floors. While it doesn't need to install sprinklers below ten floors, so we are threatened the safety. In this study, we derived causes and implications by analyzing concepts of sprinklers facilities, installation standards in domestic and foreign legal system, and recent cases that expanded damages in fire accidents because of weak point of installation and control standards. In domestic cases, as a result, government has to provide an institutional strategy and law that regulate duty to install sprinklers to all aggregate buildings regardless of floors in terms of new buildings. Also, if someone who has existing buildings wanted to install them, government would guarantee subsidy to encourage installation. In addition, government supervises fire-fighting activities when there are fire by compensating standards about regular inspection by a qualified technician, operation and maintenance of sprinklers as well as reinforcement of administrative criteria.