• Title/Summary/Keyword: Guided experiment

Search Result 164, Processing Time 0.03 seconds

Inhibitory Effects of Ninety Nine Korean Plants on Human Immunodeficiency Virus Type 1 Pretense Activity

  • Park, Jong-Cheol;Hur, Jong-Moon;Park, Ju-Gwon;Hyun, Kyu-Hawn;Lee, Kab-Yeon;Hirotsugu Miyashiro;Masao Hattori
    • Preventive Nutrition and Food Science
    • /
    • v.7 no.2
    • /
    • pp.123-127
    • /
    • 2002
  • Ninety nine extracts from Korean plants were screened for their inhibitory activities on human immunodeficiency virus (HIV) type 1 pretense by an HPLC method. The pretense inhibitory activities were determined by incubating the extracts in reaction mixtures containing pretense and substrate (His-Lys-Ala-Arg-Val-Leu-(p-NO$_2$- Phe)-Glu-Ala-Nle-Ser-NH$_2$) to perform proteolytic cleavage reactions. Of the extracts tested, the water extracts of Viburnum awabuki (stem and leaves) and Distylium racemosum (leaves) had the highest pretense inhibitory activities at a concentration of 100ug/mL. Activity-guided fractionation, revealed that the n-butanol fraction of the V. awabuki extract and the ethyl acetate fraction from the D. racemosum extract had the greatest inhibitory activity on HIV-1 pretense.

Development of Rhodamine-Based Fiber Optic Sensor for Detection of Mercury in Aqueous Environments (수용액 환경에서 수은 측정을 위한 로다민 기반의 광섬유 센서 개발)

  • Lee, Ae Ri;Kim, Yong Il;Kim, Beom Kyu;Park, Byung Gi
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.173-177
    • /
    • 2014
  • A Rhodamine-based fiber-optic sensor has been developed to detect mercury ions in aqueous environments. The fiber-optic sensor was composed of a mercury-sensing thin film, plastic optical fibers, and a spectrometer. The mercury-sensing thin film with the synthesized Rhodamine derivatives was fabricated with Sol-Gel process. A light emitted by a light source is guided by plastic optical fibers into the thin film in an aqueous solution and a reflected light is analyzed with the spectrometer. The experiment exhibits that an absorbance in the thin film is increased as mercury concentration is increased in the solution and the absorbance by mercury is higher than that by other heavy metals. The fiber-optic sensor exhibits high chromogenic phenomenon of mercury ions among various heavy metals and the correlation between absorbance and mercury concentration in the aqueous environments.

A Design of Color-identifying Multi Vehicle Controller for Material Delivery Using Adaptive Fuzzy Controller (적응 퍼지제어기를 이용한 컬러식별 Multi Vehicle의 물류이송을 위한 다중제어기 설계)

  • Kim, Hun-Mo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.5
    • /
    • pp.42-49
    • /
    • 2001
  • In This paper, we present a collaborative method for material delivery using a distributed vehicle agents system. Generally used AGV(Autonomous Guided Vehicle) systems in FA(Factory Automation) require extraordinary facilities like guidepaths and landmarks and have numerous limitations for application in different environments. Moreover in the case of controlling multi vehicles, the necessity for developing corporation abilities like loading and unloading materials between vehicles including different types is increasing nowadays for automation of material flow. Thus to compensate and improve the functions of AGV, it is important to endow vehicles with the intelligence to recognize environments and goods and to determine the goal point to approach. In this study we propose an interaction method between hetero-type vehicles and adaptive fuzzy logic controllers for sensor-based path planning methods and material identifying methods which recognizes color. For the purpose of carrying materials to the goal, simple color sensor is used instead of intricate vision system to search for material and recognize its color in order to determine the goal point to transfer it to. The technique for the proposed method will be demonstrated by experiment.

  • PDF

Effect of an initial displacement on a nano-guiding system (나노 가이드 시스템에서 초기 변위의 영향에 관한 연구)

  • Lee, Dong-Yeon;Lee, Moo-Yeon;Gweon, Dae-Gab;Park, June-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1396-1403
    • /
    • 2006
  • This study shows that the system performance of a positioning system composed of a piezoelectric actuator-driven flexure guide depends largely on the preload applied on the flexure guide and the driving input amplitude. We used a flexure guided system that had an original resonant frequency of 54Hz. Our experiment showed that we could increase the driving bandwidth above the original resonant frequency, for a case involving a large preload and a small input amplitude. Results show that there is a specific 'separation frequency' where the response of the moving mass of the flexure system decouples from the response oi the piezoelectric actuator, and this specific separation frequency can be selected by a proper choice of the preload and the input amplitude. To find the separation frequency, sine sweep tests were performed. To confirm the increased system bandwidth frequency, open-loop sine tracking experiments were performed. Test results show that the system responds very well up to 130 Hz frequency higher than the original natural frequency (54Hz).

  • PDF

Effect of an Initial Displacement on a Nano-guiding System (나노 가이드 시스템에서 초기 변위의 영향에 관한 연구)

  • Lee, Moo-Yeon;Gweon, Dae-Gab;Lee, Dong-Yeon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.4 s.109
    • /
    • pp.346-354
    • /
    • 2006
  • This study shows that the system performance of a positioning system composed of a piezoelectric actuator-driven flexure guide depends largely on the preload applied on the flexure guide and the driving input amplitude. We used a flexure guided system that had an original resonant frequency of 54 Hz. Our experiment showed that we could increase the driving bandwidth above the original resonant frequency, for a case involving a large preload and a small input amplitude. Results show that there is a specific 'separation frequency' where the response of the moving mass of the flexure system decouples from the response of the piezoelectric actuator, and this specific separation frequency can be selected by a proper choice of the preload and the input amplitude. To find the separation frequency, sine sweep tests were performed. To confirm the increased system bandwidth frequency, open-loop sine tracking experiments were performed. Test results show that the system responds very well up to 130 Hz frequency higher than the original natural frequency (54 Hz).

- For the Development of Inquiring, integrated Science Curricular Materials - The Comparison and Analysis of Inquiry Activity between "The FAST Program" and "The Secondary Science Books" (탐구적 통합 과학 교재 개발을 위한, "FAST program"과 "중등 과학 교과서"의 탐구 활동 비교 분석)

  • Son, Yeon-A;Lee, Hack-Dong
    • Journal of The Korean Association For Science Education
    • /
    • v.14 no.1
    • /
    • pp.45-57
    • /
    • 1994
  • The purpose of this study is to verify whether the FAST program is the Inquiry Science Curricular Materials, through the Comparison and Analysis of Inquiry Activities between the FAST program and our Secondary Science Books. The results of this study are as follows ; 1. FAST has 226 tasks of the Inquiry Activities, which is analyzed over two times than our text. 2. In level one, FAST holds the parts of Synthesizing Results and Evaluation, Hypothesizing and Designing an Experiment but u.ese aren't found in our text. 3. In level two, our text is analyzed No Discussion 72.2%, Demonstrating or Verifying the Content of the Text 82%, but FAST has Discussion Guided 81.8%, and isn't found any tesk of Demonstrating or Verifying the Content of the text. 4. In level three, our text is exposed a typical type I and analyzed Inquiry Index 15-25 ( Middle ), but FAST is found type IV, excepting Manipulating Apparatus and Observation and analyzed Inquiry Index over 35 ( Very - High ). Therefore, FAST Program is proved to be the desirable Inquiry Science Curricular Materials. In future, this worker is to arrange the results of the following paper as follows ; 1. The verification of the FAST Program by means of the Integrated Science Curricular Materials. 2. The development of the Inquiring, Integrated Science Curricular Materials through the results of the preceding study.

  • PDF

3D Orientation and Position Tracking System of Surgical Instrument with Optical Tracker and Internal Vision Sensor (광추적기와 내부 비전센서를 이용한 수술도구의 3차원 자세 및 위치 추적 시스템)

  • Joe, Young Jin;Oh, Hyun Min;Kim, Min Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.579-584
    • /
    • 2016
  • When surgical instruments are tracked in an image-guided surgical navigation system, a stereo vision system with high accuracy is generally used, which is called optical tracker. However, this optical tracker has the disadvantage that a line-of-sight between the tracker and surgical instrument must be maintained. Therefore, to complement the disadvantage of optical tracking systems, an internal vision sensor is attached to a surgical instrument in this paper. Monitoring the target marker pattern attached on patient with this vision sensor, this surgical instrument is possible to be tracked even when the line-of-sight of the optical tracker is occluded. To verify the system's effectiveness, a series of basic experiments is carried out. Lastly, an integration experiment is conducted. The experimental results show that rotational error is bounded to max $1.32^{\circ}$ and mean $0.35^{\circ}$, and translation error is in max 1.72mm and mean 0.58mm. Finally, it is confirmed that the proposed tool tracking method using an internal vision sensor is useful and effective to overcome the occlusion problem of the optical tracker.

Optical Characteristics of the LGP with Nanometer-patterned Sizes on Its Both Surfaces (복합 나노미터 패턴 도광판의 광특성)

  • Hong, Chin-Soo;Kim, Chang-Kyo;Lee, Byoung-Wook;Kim, Kyoung-Rae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.6
    • /
    • pp.530-534
    • /
    • 2008
  • The LGP with nanometer structures resulted in enhancement of optical efficiency. Its fundamental mechanism is to recycle the polarized light via one round-trip through QWP(Quarter-wave Plate) but the maximum efficiency to reach with this method is limited up to 2. To get the larger efficiency than this a LGP with 1D PC(one-dimensional photonic crystal) nanometer-patterned on its top and bottom surfaces is suggested. For its optimum design the computer simulation is performed and suggests a grating that the spatial frequency between adjacent patterns is 500nm, its height 250nm, duty cycle 50%, and its cross section is rectangular. The angles of transmitted light are nearly the same as the results expected from the generalized Snell's law. Thus the Mathematica code, developed in this experiment, will be applied to designing the optimized LGP. The LGP with nanometer-patterened 1D PC LGP on its both surfaces shows the enhancement of transmitted intensity distribution up to 5.7 times.

HLA/RTI based on the Simulation Composition Technology (HLA/RTI 기반의 시뮬레이션 조합 기술)

  • Kim, Jingyu
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.244-251
    • /
    • 2016
  • In defense domain, mission level and engagement level simulation tools exist. In order to experiment a simulation scenario for obtaining results of both mission level and engagement level simulations, we should write a same simulation scenario in a mission level simulation tool as well as an engagement level simulation tool, and we have to operate these tools for analysis of each purpose. Moreover, we could not guarantee that these scenarios are completely same since each scenario is composed of different fidelities of simulation models, although the scenarios are written by a same experimenter and with same simulation purpose. To deal with the difficulties, I propose an approach to analysis of both mission level and engagement level simulations from one simulation result. For this, I have built Composite Combat Mission Planning Simulation Environment (CCMPSE). In this paper, the HLA/RTI based simulation composition technology and my experiences for the designed Composite Combat Mission Planning Simulation Control System (CCMPSCS) are explained. Moreover, This paper also conducts a case study with EADSIM, SADM, and the CCMPSCS. Finally, this paper provides lesson learned from the case study.

Verification of Missile Angular Velocity Calculation Using FMS (FMS를 이용한 대전차 유도탄의 각속도 계산식 검증)

  • Park, Eo-Jin;Kim, Wan-Shik;Park, Chan-Gook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.10
    • /
    • pp.992-997
    • /
    • 2009
  • This paper focuses on the calculation of the missile angular velocity under the reduced sensor condition and its verification using the Flight Motion Simulator(FMS). The missile angular velocity is usually measured by the body gyroscopes, but we assume that the inertial sensors on the missile body are in the absence of pitch and yaw gyroscopes. Under this reduced sensor condition, this paper shows the missile angular velocity can be calculated by using the gimbal seeker gyroscope, the roll body gyroscope, the gimbal angle and its rate. The FMS experiment was carried out to verify the proposed algorithm.