• 제목/요약/키워드: Guide plate

검색결과 244건 처리시간 0.02초

사출성형공정에서 금형에 전달되는 진동 신호 측정을 이용한 성형 단계별 공정시간과 공정특성의 모니터링에 대한 연구 (A study on monitoring for process time and process properties by measuring vibration signals transmitted to the mold during injection molding)

  • 이준한;김종선
    • Design & Manufacturing
    • /
    • 제14권3호
    • /
    • pp.8-16
    • /
    • 2020
  • In this study, the vibration signal of the mold was measured and analyzed to monitoring the process time and characteristics during injection molding. A 5 inch light guide plate mold was used to injection molding and the vibration signal was measured by MPU6050 acceleration sensor module attached the surface of fixed mold base. Conditions except for injection speed and packing pressure were set to the same value and the change of the vibration signal of the mold according to injection speed and packing pressure was analyzed. As a result, the vibration signal had a large change at three points: "Injection start", "V/P switchover", and "Packing end". The time difference between "injection start" and "V/P switchover" means the injection time in the injection molding process, and the time difference between "V/P switchover" and "Packing end" means the packing time. When the injection time and packing time obtained from the vibration signal of the mold are compared with the time recorded in the injection molding machine, the error of the injection time was 2.19±0.69% and the error of the packing time was 1.39±0.83%, which was the same level as the actual value. Additionally, the amplitude at the time of "injection start" increased as the injection speed increased. In "V/P switchover", the amplitude tended to be proportional to the pressure difference between the maximum injection pressure and the packing pressure and the amplitude at the "packing end" tended to the pressure difference between the packing pressure and the back pressure. Therefore, based on the result of this study, the injection time and packing time of each cycle can be monitored by measuring the vibration signal of the mold. Also, it was confirmed that the level and trend of process variables such as the injection speed, maximum injection pressure, and packing pressure can be evaluated as the change of the mold vibration during injection molding.

In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants

  • Huh, Young-June;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제42권3호
    • /
    • pp.139-146
    • /
    • 2012
  • Purpose: An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement. Materials and Methods: A resin template was fabricated from a hog mandible and a specially designed plastic plate, with 4 metal balls inserted in it for radiographic recognition, was attached to the occlusal surface of the template. With the surgical stent applied, CT images were taken, and virtual implants were placed using software. The spatial positions of the virtually positioned implants were acquired and implant guiding holes were drilled into the surgical stent using a specially designed 5-axis drilling machine. The surgical stent was placed on the mandible and CT images were taken again. The discrepancy between the central axis of the drilled holes on the second CT images and the virtually installed implants on the first CT images was evaluated. Results: The deviation of the entry point and angulation of the central axis in the reference plane were $0.47{\pm}0.27$ mm, $0.57{\pm}0.23$ mm, and $0.64{\pm}0.16^{\circ}$, $0.57{\pm}0.15^{\circ}$, respectively. However, for the two different angulations in each group, the $20^{\circ}$ angulation showed a greater error in the deviation of the entry point than did the $10^{\circ}$ angulation. Conclusion: The CT-guided template proposed in this study was highly accurate. It could replace existing implant guide systems to reduce costs and effort.

살수방식에 따른 재배용기내 Gas 조성 및 콩나물의 생육 변화 (Growth of Soybean Sprouts and Concentration of $CO_2$ Produced in Culture Vessel Affected by Watering Methods)

  • 배경근;남승우;김경남;황영현
    • 한국작물학회지
    • /
    • 제49권3호
    • /
    • pp.167-171
    • /
    • 2004
  • 콩나물 재배에서의 살수방법과 그에 따른 콩나물 생육형태와 수율변화를 비교해본 결과 다음과 같다. 1. 살수방식에 따른 콩나물의 생육에 큰 차이를 나타내었으며, 왕복살수형, 용기담수형, 고정살수형 중 고정살수형 방식(재배통 상부에 하부타공된 고정형 물통설치에 의해 샤워형태로 살수)은 살수시 일시에 물을 샤워형식으로 쏟아내려 재배통 내부의 품온저하($22^{\circ}$ 유지), 내부 gas 배출, 유기물 제거 등의 효과가 탁월하여 콩나물 생육에 있어 몸통길이 13.3 cm로 다른 형식(15.2 cm, 15.9 cm)에 비해 짧았으나, 몸통두께(2.19 mm), 수율(535%)은 높게 나타나, 외관이 양호하고 부패가 억제되어 선도가 가장 잘 유지되었으며, 또한, 콩나물 재배시 필요한 용수량의 경우는 1회 살수량이 250∼300 L/통(원료콩 투입량 50 kg/통 기준)가 가장 양호한 것으로 나타났다. 2. 고정살수형 방식은 내부 gas($\textrm{CO}_2$ 5% 이하)배출이 탁월하여 재배완료 후 콩나물의 색택향상 및 부분부패 방지효과 등을 나타내는 장점이 있었으며, 재배 6일차에 재배통 하부(바닥깔판으로부터 약 30 cm이내)의 $\textrm{CO}_2$ 농도는 4-6%, $\textrm{O}_2$ 농도는 13-14%이었다. 따라서 재배시 재배통내 적정 gas조건은 농도 10% 이상, $\textrm{CO}_2$ 농도 5% 이하로 유지되어야 할 것으로 판단되었다. 3. 살수방식에 따른 재배통내의 품온 변화에서도 고정살수형 방식(4일차, $20^{\circ}$)이 용기담수형 방식(4일차, $22^{\circ}$)보다 품온 억제가 양호하여 콩나물의 생육향상 및 부패 등을 방지하므로 건강한 콩나물 생산의 중요한 요인임을 알 수 있었다.되지 않은 부분에 대해서 안전성 확보를 위하여 더 자세한 연구가 필요하다..6%이었다.program should be prepared through the long-period of monitoring and experiment. System methods such as guidelines of management program through monitoring was also required due to the emphasis on public ownership among the managers of the invasive species. 보이며 가장 높은 평가를 받았으며, chlorella 향, 단맛, 신맛에 있어서도 비교적 우수한 평가를 받아 관능적으로 높은 기호도를 나타내었고 올리고당의 첨가량은 20% 첨가시 후미와 전체적인 기호도에서 가장 좋게 평가되었다.ts might or might not be for tobacco use. However, most of the cigarette companies self impose a list of ingredients to guide flavor suppliers to design flavors. Unfortunately, the number of ingredients in those lists is getting shorter every year. It is understandable that the health is not the only reason. Some cigarette companies are playing safe to protect the company from potential lawsuit, while others are just copying from their competitors. Moreover, it is obvious that it needs more assistance from casings and

방사선사고시 피폭선량평가를 위한 휴대전화 부품의 전자상자성공명(EPR) 특성에 대한 예비 연구 (Preliminary Study on Electron Paramagnetic Resonance(EPR) Signal Properties of Mobile Phone Components for Dose Estimation in Radiation Accident)

  • 박병룡;하위호;박선후;이진경;이승숙
    • Journal of Radiation Protection and Research
    • /
    • 제40권4호
    • /
    • pp.194-201
    • /
    • 2015
  • 본 연구에서는 전자상자성공명(electron paramagnetic resonance, EPR) 장치를 사용한 휴대전화 부품들의 EPR 특성 측정을 통해 방사선사고시 회구적 선량평가용 선량계로써 활용가능성에 대하여 확인하였다. 화면표시 방식이 다른 두 스마트폰에서 12개의 시료를 선정하여 실험에 사용하였고, 시료의 방사선조사에는 $^{137}Cs$ 감마선 그리고 EPR 측정은 실온에서 Bruker사의 ELEXSYS E500 X-Band EPR spectrometer를 사용하여 수행하였다. 먼저 각 시료에 대하여 비조사시료와 조사시료의 EPR 스펙트럼을 측정하여 방사선에 의한 라디칼 생성 여부를 확인하였고, 그 후 선량반응곡선과 시간에 따른 시그널 크기 변화를 측정하였다. 측정결과 유심 플라스틱과 IC 칩을 제외한 모든 시료에서 방사선에 의한 EPR 시그널 증가를 확인할 수 있었다. 시료 중에서 덮개유리, 카메라렌즈, 도광판, 확산시트는 결정계수 $R^2=0.93$이상의 좋은 선형상관관계를 보였다. 특히 도광판은 선량에 따른 시그널 증가량이 가장 크고 백그라운드 시그널이 없기 때문에 선량평가에 이상적인 특성을 가지고 있었지만, 72 시간 이내에 시그널이 약 50% 감소하는 약점이 있었다. 확산시트 또한 도광판과 유사한 페이딩 특성을 나타내었고, 덮개유리와 카메라렌즈는 단기간 동안에는 시그널이 안정적으로 보존되었다. 휴대전화 부품을 이용한 EPR 선량평가를 실제 대규모 방사선 사고에서 신속하게 적용하기 위해서는 더 많은 휴대전화 기종의 같은 부품에 대한 시그널 차이, 페이딩, 시료 전처리 방법 등에 대한 추가연구가 진행될 필요가 있다. 그러나 현재 결과를 바탕으로 소규모 방사선사고시 피폭환자가 소지하고 있던 휴대전화와 동일한 제품을 구입하여 비교하는 방법 또는 추가조사법을 이용한 선량평가는 가능할 것으로 판단된다.