• Title/Summary/Keyword: Guide plate

Search Result 244, Processing Time 0.026 seconds

Effect of a vertical guide plate on the wind loading of an inclined flat plate

  • Chung, Kung-Ming;Chou, Chin-Cheng;Chang, Keh-Chin;Chen, Yi-Jun
    • Wind and Structures
    • /
    • v.17 no.5
    • /
    • pp.537-552
    • /
    • 2013
  • Wind tunnel experiments were performed to study the wind loads on an inclined flat plate with and without a guide plate. Highly turbulent flow, which corresponded to free-stream turbulence intensity on the flat roof of low-rise buildings, was produced by a turbulence generation grid at the inlet of the test section. The test model could represent a typical solar collector panel of a solar water heater. There are up-stream movements of the separation bubble and side-edge vortices, more intense fluctuating pressure and a higher bending moment in the turbulent flow. A guide plate would result in higher lift coefficient, particularly with an increased projected area ratio of a guide plate to an inclined flat plate. The value of lift coefficient is considerably lower with increased free-stream turbulent intensity.

Guide plates on wind uplift of a solar collector model

  • Chung, K.M.;Chang, K.C.;Chen, C.K.;Chou, C.C.
    • Wind and Structures
    • /
    • v.16 no.2
    • /
    • pp.213-224
    • /
    • 2013
  • One of the key issues affecting the promotion of solar water heaters in Taiwan is the severe impact of typhoon each year. An experimental study was conducted to investigate the wind uplift characteristic of a solar collector model with and without a guide plate. The guide plate with different lengths and orientations with respect to wind direction was adopted. It is found that the wind uplift of a solar collector is associated with the tilt angle of the flat panel as expected. A cavity formed between the guide plate and the flat panel has a significant effect on the distributions of streamwsie and lateral pressure. Reduction in uplift is essentially coupled with the projected area of a guide plate on the lower surface of the tilt flat panel.

A Study on the Injection Molding for the tight Guide Plate of a Small Sized LCD (1) : finite Element Analysis and Mold Design (소형 LCD 도광판의 사출성형에 관한 연구 (1) : 유한요소해석 및 금형설계)

  • 이호상
    • Transactions of Materials Processing
    • /
    • v.11 no.4
    • /
    • pp.332-340
    • /
    • 2002
  • The light guide plate of the TFT-LCD reflects the light originated from the light source, and guides the light to the front side of LCD so that we can see images vividly. This paper is concerned with tile injection molding of the light guide plate for the reflective typed LCD related to IMT-2000. The finite element analysis has been carried out based on the pine stress theory to predict both the thermal stresses of the products in the post-filling stage and the in-plane deformation behavior of the products after ejection process. Based on the simulation results, the mold for the light guide plate of a 2inch sized LCD has been designed.

A Compatibility Study on Blank Support Structure for Large and Curved Thick Plate Forming (대곡면 후곡판 성형을 위한 블랭크 지지구조의 적합성 연구)

  • Lim, M.R.;Kwak, B.S.;Kang, B.S.;Ku, T.W.
    • Transactions of Materials Processing
    • /
    • v.28 no.6
    • /
    • pp.335-346
    • /
    • 2019
  • Thick plate forming is presented to manufacture a large and curved member of steam turbine diaphragm. Due to three-dimensional asymmetry of target geometry, it is hard to consistently keep the blank position in die cavity between forming punch and die. In order to relieve the position instability of the blank during the thick plate forming, a blank support structure is proposed to be composed of guide pins and linear bearing, and blank guide arm enlarged from both longitudinal ends of the thick blank. In this study, parametric investigations with regard to the geometric position and width of the blank guide arm are carried out. As main geometric parameters, 2 positions such as maximum curvature region and minimum one on a curved cross-section profile of the target shape are selected, and 14 widths of the blank guide arm are considered. Using 28 variable combinations, three-dimensional numerical simulations are performed to predict the appropriate range of the process parameters. The compatibility and validity of the blank support structure with the blank guide arm for the thick plate forming is verified through the thick plate forming experiments.

Simulation Study on the Optimization of Hybrid Light Guide Plates for Edge-lit Backlight Applications

  • Lee, Jeong-Ho;Nahm, Kie-Bong;Ko, Jae-Hyeon;Kim, Joong-Hyun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.693-696
    • /
    • 2009
  • The ray-tracing technique was used to optimize the light guide plate for the purpose of improving the on-axis luminance on the edge-lit backlights. One-dimensional prisms and engraved V-shaped patterns were applied to the upper and the lower surfaces of the light guide plate, respectively. By optimizing the apex angles of these micro-structures, as well as the shape of the reverseprism film put over the light guide plate, highly-collimated light-output distribution could be obtained on the backlight, which may contribute to the development of mobile LCD's with low power consumption.

  • PDF

A Study on the Injection Molding for the Light Guide Plate of a Small Sized LCD (2) : Influences of Processing Conditions on the Brightness (소형 LCD 도광판의 사출성형에 관한 연구 (2) : 공정조건이 휘도에 미치는 영향)

  • 이호상
    • Transactions of Materials Processing
    • /
    • v.11 no.4
    • /
    • pp.341-348
    • /
    • 2002
  • For the light guide plate of the TFT-LCD, there have been increasing demands for higher brightness, thin and light-weight design, and lower power consumption. To meet these demands, a micro-prism-type frontlight that integrates a prismatic sheet and a light-guiding plate has been developed. In this paper, the influences of processing conditions on the brightness were studied lot the injection molding of the light guide plate. Based on the experiment with an actual mold, the design of experiments and the neural network theory were used lot choosing the optimal processing parameters to increase the brightness and the uniformity. The verification experiment also showed that the brightness and the uniformity were increased dramatically with the chosen processing conditions.

Load Concentration Factor Analysis of Fuel Assembly Guide Thimble (핵연료집합체 안내관의 하중집중계수 해석)

  • Lee Young-Shin;Jeon Sang-Youn
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.93-100
    • /
    • 2005
  • The top and bottom nozzles of PWR fuel assembly are connected by guide thimbles and an instrumentation tube that are connected with spacer grids. The fuel rods are inserted into the each cell of spacer grids. The loads acting on the fuel assembly are transmitted to the guide thimbles through the flow plate of top nozzle The axial loads applied to the fuel assembly are not equally distributed among the guide thimble due to the geometry of the top nozzle flow plate and spacer grid. In this study, the load concentration factors for the $17\times17$ fuel assembly were calculated. The analytical model fur the calculation of the load concentration factor of top nozzle flow plate was developed using ANSYS 5.6. The finite element analyses were performed using the model composed of top nozzle, guide thimble, and spacer grid. And, the analysis results were compared with the test results.

Feasibility Study of the Light-outcoupling Characteristics of a Diffraction-grating-imprinted Light-guide Plate for an LCD Backlight Unit (LCD 백라이트 유닛의 서브 마이크론 회절 격자 도광판의 광 출사 특성 연구)

  • Choi, Hwan Young
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.4
    • /
    • pp.176-182
    • /
    • 2020
  • The possibility of replacing the condensing-prism film used in conventional backlight units with a light-guide plate engraved with a submicrometer-periodic diffraction grating was investigated. The optimal period for the diffraction grating was determined through simulation and experiment, and the transmission-mode efficiency of the diffraction grating was calculated in terms of the polar angle and azimuthal angle of the incident light. In addition, the effects of the two methods of optimizing the polar angle and the directional angle were compared by simulation, by suggesting the shape and configuration of the light-guide plate, so that more light could be extracted by diffraction. By using a ray-tracing program, the luminance angular distribution of the light-guide plate engraved with the diffraction grating was calculated and compared to the luminance angular distribution for each actual prototype.

Effect of the suction plate shape on metering performance of a vacuum metering device for garlic seeds

  • Kim, Deok-Keun;Choi, Yeong-Soo;Yang, Seung-Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.4
    • /
    • pp.829-844
    • /
    • 2020
  • A vacuum metering device for garlic seeds was developed, and its metering performance was tested according to the design factors. Three design factors were as follows: suction surface diameter (Edge), suction surface curvature (Type), and guide height (Guide). The suction surface curvature represents the distance between the center of the grooved suction plate and the bottom of suction plate. The metering rate and multiple metering rate were analyzed as the metering performance of the developed device with two varieties of garlic seeds: Namhae (warm region-adapted garlic) and Uiseong (cold region-adapted garlic). The best metering performance for the Namhae seeds were found with the following conditions: An Edge, Guide and Type of 40, 4, and 35 mm, respectively. In the case of the Uiseong seeds, the best conditions were as follows: An Edge, Guide and Type of 35, 4, and 30 mm, respectively. The guide height was found to be the most influential design factor on the metering performance of the metering rate and multiple rate for both Namhae seeds and Uiseong seeds. Additionally, the interaction between the area of the suction surface and the curvature of the suction surface had some effects on the multiple rate for the Uiseong seeds. It was concluded that the guide height should be 4 mm or higher so that more than 90% of the metering rate could be achieved for the tested garlic seeds with the developed metering device.

The Effects of Injection Molding Conditions on Uniformity and Brightness of Light Guide Plate (도광판의 균일도 및 휘도에 사출성형조건이 미치는 영향)

  • Lee Sung-Hee;Kim S.W.;Lee H.S.;Kim J.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1609-1612
    • /
    • 2005
  • The effects of injection molding conditions on the uniformity and brightness of light guide plate(LGP) with micro-patterns were investigated in the present study. An injection molding system for stampers with mirco-pattern was designed and manufactured to perform experiment. Variations of injection molding speed, mold and melt temperature for LGP were considered in this work. Also, injection molding characteristics of LGP were investigated by numerical analysis using plastic injection molding commercial code. It was shown that injection molding conditions such as injection speed, melt temperature and mold temperature can have an effect on the uniformity and brightness of light guide plate.

  • PDF