• 제목/요약/키워드: Guide 1.60

검색결과 176건 처리시간 0.024초

BTA드릴의 절삭 기구와 마모 특성에 관한 연구 (A Study on Cutting Mechanism and Wear Character for BTA Drill)

  • 장성규;전언찬
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.105-108
    • /
    • 1995
  • So far,in deep drilling process there are several manufacturing problems such as hole deviation, hole over size, circularity,straightness and surface roughness. Whit regard to these problems, we atudied the abrasion process on carbided tip of BTA drill and got the follow test results through the abrasion characteristic test and analysis on cutting mechanism for the drill tooth and guide pad. 1) In SM55C drilling process, the most stable and reasonable drilling speed range for optmum abrasion characteristic of drill tooth was 60m.min. 2) The total drilling torque was about 60kg .deg.cm on condition drilling speed 60m/min and 0.15mm/rev. These results show that the theoretical burnising torque is well accord with the tested torque which is working on guide pad.

  • PDF

광학시트를 제거한 복합 도광판 설계 연구 (A Study on an Integrated Light Guide Plate)

  • 이윤미;이준호;전은채
    • 한국광학회지
    • /
    • 제21권2호
    • /
    • pp.53-60
    • /
    • 2010
  • 본 논문에서는 휴대전화용 백라이트 유닛의 광학시트를 줄이면서도 휘도와 휘도균일도 및 시야각을 유지하기 위한 복합 도광판을 설계하고 가공하였다. 복합 도광판의 패턴은 가공성을 고려하여 윗면에는 마이크로 급의 프리즘 패턴을 형성하고 아랫면은 나노 및 마이크로 급의 크기가 다른 두 개의 음각 프리즘 패턴을 형성하였다. 이러한 패턴 형상은 금형 코어를 이용한 사출성형을 통해 복합 도광판의 가공성을 확인하였다. 특히 최적화된 복합 도광판은 프리즘 시트 한 장만을 채용하여 통상적인 백라이트 유닛과 유사한 휘도 4560 cd/$m^2$, 휘도균일도 83%, 수직 시야각 $60^{\circ}$, 수평 시야각 $56^{\circ}$라는 성과를 얻을 수 있었다. 결과적으로 도광판의 윗면과 아랫면에 복합 패턴들을 형성함으로써 기존의 백라이트 유닛에서 확산시트 및 프리즘시트 1장을 제거하여 BLU에 적용될 수 있음을 확인하였다.

가동중 원자력 시설 주변 주민의 내부피폭선량 계산을 위한 농산물내 핵종 농도 평가법 개선 (Improvement on the Method of Estimating Radionuclide Concentrations in Agricultural Products for the Off-Site Internal Dose Calculation for Operating Nuclear Facilities)

  • 최용호;임광묵;황원태;최근식;최희주;이창우
    • Journal of Radiation Protection and Research
    • /
    • 제29권2호
    • /
    • pp.73-90
    • /
    • 2004
  • Reg. Guide 1.109의 농작물내 핵종농도 계산모델을 가동중인 원자력 시설에 적용함에 있어서의 문제점을 분석하고 개선 방안을 제시하였다. 뿌리흡수 평가에 있어서는 가동개시후 침적한 방사성 핵종이 고려될 수 있도록 모델을 변형하였다. 직접침적에 의한 가식부위내 농도 계산식에는 전류계수를 도입하였다. 변형모델의 입력변수에 내하여 국내 특성치를 설정하였다. Reg. Guide 1.109 모델과 변형모델에 동 지침서의 변수치와 국내 특성 변수치를 번갈아 입력하여 쌀알, 배추, 무 뿌리 내 $^{54}Mn,\;^{60}Co,\;^{90}Sr,\;^{137}Cs$의 농도를 다양한 가상의 침적 이력에 대해 계산, 비교하였다. 이를 통해 변형모델에 국내 특성 변수치를 사용함으로써 보다 합리적이고 현실적인 평가가 이루어 질 것으로 기대할 수 있었다.

공명 흡음판 위 가이드 그릴의 형상이 공진기 흡입 유동에 미치는 영향 (Effect of the Shape of a Guide Grill Above a Resonance Type Sound Absorbing Panel on Intake Flow into a Resonator)

  • 배현우;성재용;이동훈
    • 한국생산제조학회지
    • /
    • 제25권3호
    • /
    • pp.182-188
    • /
    • 2016
  • This study investigates cavity flows through a guide grill above a resonator. Vortex distributions and intake flows are simulated for various shapes of the guide grill. The flows are assumed to be compressible, unsteady, and turbulent. Numerical simulations are conducted using a large eddy simulation (LES) model. To analyze the effect of the guide grill shape, three cavity lengths (0.2H, 0.6H, and 1.0H) and cavity angles ($30^{\circ}$, $45^{\circ}$ and $60^{\circ}$) are considered based on resonator height (H). The results show that the vortex generated in the resonator by cavity flow increases with cavity length. Thus, the intake flow is minimum at the smallest cavity length and angle. However, when cavity length is equal to resonator height, the intake flow decreases. The maximum intake flow occurs at a cavity angle $45^{\circ}$ at higher cavity lengths owing to the interaction between the vortex in the resonator and intake flow.

비가역성 쌍토로이드 페라이트 변위기 설계 (Design of Nonreciprocal Twin-toroidal Ferrite Phase Shifter)

  • 이기오;김영범;박동철;신용수;김윤명
    • 한국전자파학회논문지
    • /
    • 제7권1호
    • /
    • pp.43-52
    • /
    • 1996
  • 비가역성 쌍토로이드 페라이트 변위기를 설계, 제작하고 그 특성 실험올 하였다. 변위기의 최적 칫수를 구하기 위해 ABCD 행렬 방법을 사용하였으며, 빈 도파관 부분과 페라이트가 삽입된 부분과의 임피던스 정합을 위해 $\lambda$/4 2단 변환기를 이용하였다. 변위기를 구동시키기 위한 구동회로를 제작하 였으며, 중심주파수 9.3GHz, 동작대역폭 400MHz 에서 측정한 변위기의 삽입손실과 VSWR은 각각 1.2clB, 1.16미만으로써 만족할만한 결과를 얻었다. 또한, 페라이트의 특성이 온도변화에 종속적이기 때문에 온도보상기법을 통해 온도에 따른 변위차 변화량을 보상하였으며, 온도보상결과 $-10^{\circ}C~+60^{\circ}C$사이에 $\pm4^{\circ}$ 이내의 위상오차를 얻을 수 있었다.

  • PDF

공기를 작동 유체로 하는 열다이오드의 천이 과정중 열성능에 관한 실험적 연구 (An Experimental Study on the Thermal Performance of Air filled Thermal Diode during Transfer Process)

  • 황인주;장영근;박이동;김철주
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 추계학술발표회 논문집
    • /
    • pp.171-175
    • /
    • 1996
  • thermal diode is a device which allows heat to be transferred in one direction by convection due to difference of density of fluid. Vertical plate for heat collection and radiation are of utility for design of thermal diode. It was considered the transient process of air filled thermal diode with guide vane which combined rectangular and parallelogrammic shape enclosures. Gr was kept constantly on 1.60$\times$1010 and error range was $\pm$2% during the experiment. Nu was examined when inclined angle are 15$^{\circ}$and 45$^{\circ}$and, also the experiments was carried out with and without guide vane as well. Specially, The effect of guide vane was sensitive. Developed region inclined angle, which is characteristic of system.

  • PDF

Adjustable Ghajar Guide Technique for Accurate Placement of Ventricular Catheters : A Pilot Study

  • Yoon, Sang-Youl;Kwak, Youngseok;Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권5호
    • /
    • pp.604-609
    • /
    • 2017
  • Objective : An adjustable Ghajar guide is presented to improve the accuracy of the original Ghajar guide technique. The accuracy of the adjustable Ghajar guide technique is also investigated. Methods : The coronal adjustment angle from the orthogonal catheter trajectory at Kocher's point is determined based on coronal head images using an electronic picture archiving and communication system. For the adjustable Ghajar guide, a protractor is mounted on a C-shaped basal plate that is placed in contact with the margin of a burrhole, keeping the central $0^{\circ}$ line of the protractor orthogonal to the calvarial surface. A catheter guide, which is moved along the protractor and fixed at the pre-determined adjustment angle, is then used to guide the ventricular catheter into the frontal horn adjacent to the foramen of Monro. The adjustable Ghajar guide technique was applied to 20 patients, while a freehand technique based on the surface anatomy of the head was applied to another 47 patients. The accuracy of the ventricular catheter placement was then evaluated using postoperative computed tomography scans. Results : For the adjustable Ghajar guide technique (AGT) patients, the bicaudate index ranged from 0.23 to 0.33 ($mean{\pm}standard$ deviation [SD] : $0.27{\pm}0.03$) and the adjustment angle ranged from $0^{\circ}$ to $10^{\circ}$ ($mean{\pm}SD:5.2^{\circ}{\pm}3.2^{\circ}$). All the AGT patients experienced successful cerebrospinal fluid diversion with only one pass of the catheter. Optimal placement of the ventricular catheter in the ipsilateral frontal horn approximating the foramen of Monro (grade 1) was achieved in 19 patients (95.0%), while a suboptimal trajectory into a lateral corner of the frontal horn passing along a lateral wall of the frontal horn (grade 3) occurred in 1 patient (5.0%). Thus, the AGT patients experienced a significantly higher incidence of optimal catheter placement than the freehand catheterized patients (95.0% vs. 68.3%, p=0.024). Moreover, none of the AGT patients experienced any tract hemorrhages along the catheter or procedure-related complications. Conclusion : The proposed adjustable Ghajar guide technique, using angular adjustment in the coronal plane from the orthogonal trajectory at Kocher's point, facilitates accurate freehand placement of a ventricular catheter for hydrocephalic patients.

APR1000 원자로용기의 환경피로 평가 (Environmental Fatigue Evaluation of APR1000 Reactor Vessel)

  • 김종민;김용환
    • 한국전산구조공학회논문집
    • /
    • 제26권3호
    • /
    • pp.207-212
    • /
    • 2013
  • APR1000(Advanced Power Reactor 1000)은 기존의 OPR1000(Optimized Power Reactor 1000)에 60년 설계수명, 국부주파수제어운전, 0.3g 안전정지지진하중 적용 등의 향상된 설계특성(Advanced Design Feature)을 적용하여 개선한 수출형 1000MW 원전이다. 이 논문에서는 Reg. Guide 1.207에서 요구하는 원자로냉각재 환경을 고려한 피로 평가를 원자로용기에 대하여 평가하였다. 원자로용기에서 비교적 누적사용계수가 높은 출구노즐을 대상으로 평가를 수행하였으며 출구노즐은 구조적 건전성을 만족하는 것으로 평가되었다.

롱 스트로크 정밀 스테이지용 원통형 리니어모터의 설계 및 운전 특성 (Design and Operating Characteristics of Cylindrical Linear Motor for Long Stroke Precision Stage)

  • 안극섭;김홍중;안진우;코세키 타카후미
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.63-70
    • /
    • 2011
  • This paper presents the design and operating characteristics of the novel cylindrical linear motor which is designed for the long stroke XY stage. In the long stroke structure, the air gap is changed by the distortion and bending effects, and it makes additional position error in the XY stage. In order to consider the distortion and bending effects of the long stroke, the field part of the cylindrical linear motor is designed as an open structure, and the stroke is supported by the bridge guide which is positioned in the open field part. The mechanical bridge guide can reduce the bending effects of the stroke and can keep a constant air gap. The detailed design process of the proposed cylindrical linear motor is presented in this paper. The proposed motor is analyzed by the 3D FEM technology. The practical XY stage which uses the proposed motor is tested to verify the propose novel cylindrical linear motor. The FEM and experimental results show the effectiveness of the proposed motor.

Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro study

  • Dler Raouf Hama;Bayad Jaza Mahmood
    • Journal of Periodontal and Implant Science
    • /
    • 제53권5호
    • /
    • pp.388-401
    • /
    • 2023
  • Purpose: This study investigated the accuracy of free-hand implant surgery performed by an experienced operator compared to static guided implant surgery performed by an inexperienced operator on an anterior maxillary dental model arch. Methods: A maxillary dental model with missing teeth (No. 11, 22, and 23) was used for this in vitro study. An intraoral scan was performed on the model, with the resulting digital impression exported as a stereolithography file. Next, a cone-beam computed tomography (CBCT) scan was performed, with the resulting image exported as a Digital Imaging and Communications in Medicine file. Both files were imported into the RealGUIDE 5.0 dental implant planning software. Active Bio implants were selected to place into the model. A single stereolithographic 3-dimensional surgical guide was printed for all cases. Ten clinicians, divided into 2 groups, placed a total of 60 implants in 20 acrylic resin maxillary models. Due to the small sample size, the Mann-Whitney test was used to analyze mean values in the 2 groups. Statistical analyses were performed using SAS version 9.4. Results: The accuracy of implant placement using a surgical guide was significantly higher than that of free-hand implantation. The mean difference between the planned and actual implant positions at the apex was 0.68 mm for the experienced group using the free-hand technique and 0.14 mm for the non-experienced group using the surgical guide technique (P=0.019). At the top of the implant, the mean difference was 1.04 mm for the experienced group using the free-hand technique and 0.52 mm for the non-experienced group using the surgical guide technique (P=0.044). Conclusions: The data from this study will provide valuable insights for future studies, since in vitro studies should be conducted extensively in advance of retrospective or prospective studies to avoid burdening patients unnecessarily.