• Title/Summary/Keyword: Group Flow

Search Result 2,202, Processing Time 0.029 seconds

THE EFFECT OF FLOWABLE RESIN LINING ON THE MARGINAL MICROLEAKAGE OF CONDENSABLE RESIN RESTORATION (응축형 복합레진 수복시 유동성 레진 이장이 변연부 미세누출에 미치는 영향)

  • 문주훈;고근호
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.16-22
    • /
    • 2001
  • The purpose of this study was to evaluate the marginal microleakage of condensable composite resin restorations according to flowable resin lining of internal cavity wall. The eighty extracted human molar teeth without caries and/or restorations are used The experimental teeth were randomly assigned into four groups of ten teeth each. Eighty caries-free extracted human molars were used in this study. The conventional class II cavities (box-shaped on mesial and distal surface, faciolingual width : 3mm, gingival wall depth : 1.5mm) were prepared 1mm below cementoenamel junction with a # 701 carbide bur. The teeth were divided into four groups, and then each group were subdivided into A & B group according to flowable resin & compomer lining ; Group 1-A : Tetric Ceram filling, Group 1-B : Tetric Flow lining and Tetric Ceram filling, Group 2-A Ariston pHc filling, Group 2-B : Tetric Flow lining and Ariston pHc filing, Group 3-A SureFil filling, Group 3-B : Dyract Flow lining and SureFil filling, Group 4-A : Pyramid filling, Group 4-B : Aeliteflo lining and Pyramid filling. To simulate as closely as possible the clinical situation during retoration placement, a "restoration template" was fabricated, and the condensable resin was filled using a three-sited light-curing incremental technique. All the materials used were applied according to the manufacturers' instructions. The specimens were stored in the 100% humidity for 7 days prior to thermocycling (100 thermal cycles of 5~55$^{\circ}C$ water with a 30-second dwell time) The specimens were immersed in 2% metyleneblue dye for 24 hours, and then embedded in transparent acrylic resin and sectioned mesiodistally with diamond wheel saw. The degree of marginal leakage was scored under stereomicroscope ($\times$20) and the data were analyzed by Kruskal-Wallis test and Wilcoxon signed ranks test. The results were as follows : 1. In the gingival margins of all the group, microleakage of subgroup B was less than subgroup A. 2. In the group 1, 2, 4, there was significant differences between subgroup A and B (p<0.05), but in the group 3, there was not significant different between group 3-A (SureFil) and group 3-B (Dyract flow/SureFil) (p>0.05). 3. In the subgroup A and B, there was significant different between all group except group 4 of subgroup A. From the results above, it was suggested that the cavity lining of flowable resin and flowable compomer in condensable resin restoration decrease microleakage at gingival margin, and does improve their ability to seal the gingival margin of class II preparation.

  • PDF

CUSPAL DEFLECTION IN CLASS V CAVITIES RESTORED WITH COMPOSITE RESINS (5급 와동의 복합레진 수복 시 발생되는 교두굴곡에 관한 연구)

  • Park, Jun-Gyu;Lim, Bum-Soon;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.83-89
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of the polymerization shrinkage and modulus of elasticity of composites on the cusp deflection of class V restoration in premolars. The sixteen extracted upper premolars were divided into 2 groups with similar size. The amounts of cuspal deflection were measured in Class V cavities restored with a flowable composite (Filtek flow) or a universal hybrid composite (Z-250). The bonded interfaces of the sectioned specimens were observed using a scanning electron microscopy (SEM). The polymerization shrinkage and modulus of elasticity of the composites were measured to find out the effect of physical properties of composite resins on the cuspal deflection. The results were as follows. 1. The amounts of cuspal deflection restored with Filtek flow or Z-250 were $2.18\;{\pm}\;0.92{\mu}m$ and $2.95\;{\pm}\;1.13\;{\mu}m$, respectively. Filtek flow showed less cuspal deflection but there was no statistically significant difference (p > 0.05). 2. The two specimens in each group showed gap at the inner portion of the cavity. 3. The polymerization shrinkages of Filtek flow and Z-250 were 4.41% and 2.23% respectively, and the flexural modulus of elasticity of cured Filtek flow (7.77 GPa) was much lower than that of Z-250 (17.43 GPa). 4. The cuspal deflection depends not only on the polymerization shrinkage but also on the modulus of elasticity of composites.

Comparison of the Effects of Pilocarpine Solution and Tablet on Salivary Flow Rate

  • Park, Jo-Eun;Song, Chan-Woo;Kim, Ki-Suk;Kim, Mee-Eun
    • Journal of Oral Medicine and Pain
    • /
    • v.40 no.1
    • /
    • pp.10-16
    • /
    • 2015
  • Purpose: Pilocarpine has the effects on improvement of salivary flow and subjective symptoms for xerostomic patients. Because of unwanted side effects following its systemic administration, topical pilocarpine has been paid attention as an alternative. This study aimed to investigate effects of pilocarpine solution as mouthwash on salivary flow and adverse effects compared to systemic administration of 5 mg pilocarpine tablet in healthy subjects. Methods: The study was a double blind, placebo-controlled, crossover clinical trial. Five milligrams pilocarpine tablets, 4 mL of 2% pilocarpine solution and placebo solution were given to 12 healthy volunteers (6 males and 6 females) in a predetermined order with wash-out period of at least two days and unstimulated whole saliva was collected before and after administration of each drug. Blood pressure and pulse rate was also measured and subjective effect and potential side effects were evaluated by a self-administrated questionnaire. Results: Systemic (5 mg tablet) and topical (2% solution) use of pilocarpine significantly increased salivary flow rate in healthy subjects compared to placebo (p<0.001). In both the pilocarpine solution and tablet groups, salivary flow rates at 120 minutes after administration remained increased. Subjective effect on salivation was the largest in the pilocarpine tablet group, followed by the pilocarpine solution group (p<0.05). There was no significant difference in blood pressure and pulse rate after administration of all three drugs. Fewer side effects reported in the pilocarpine solution group than in the tablet group. Conclusions: Two percents pilocarpine solution as mouthwash increases salivary flow rate, definitely superior to placebo solution and comparable to pilocarpine tablet, with fewer side effects in healthy subjects. It indicates a possibility of pilocarpine solution as a useful alternative of pilocarpine tablets for the xerostomic patients with systemic diseases.

COMPARISON OF COMPRESSIVE STRENGTH AND SURFACE MICROHARDNESS BETWEEN FLOWABLE COMPOSITE RESIN AND GIOMER (유동성 자이오머와 복합 레진의 압축 강도 및 표면 미세 경도 비교)

  • Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.4
    • /
    • pp.383-388
    • /
    • 2012
  • The aim of this study was to compare the compressive strength and the surface microhardness of Beautifil flow (Shofu, Kyoto, Japan) with $Filtek^{TM}$ Z350, Z350XT (3M ESPE, USA). Fifteen specimens from each material were fabricated for testing. Compressive strength was measured by using a universal testing machine at a crosshead speed of 1 mm/min. Surface microhardness values were measured by using Vickers hardness tester under 4.9 N load and 10 seconds dwelling time. The compressive strength of Group 2 $Filtek^{TM}$ Z350XT shows the highest value as $218.7{\pm}18.4$ MPa and Group 1 $Filtek^{TM}$ Z350 was $205.5{\pm}27.1$ MPa. Group 3 Beautifil flow F00 was $176.5{\pm}30.3$ MPa, and Group 4 Beautifil flow F10 was $173.4{\pm}26.2$ MPa. The compressive strength of Group 2 is higher than Group 3 and 4 (p < 0.05). The surface microhardness of Group 2 $Filtek^{TM}$ Z350XT shows the highest value as $39.1{\pm}2.1$ and Group 4 Beautifil flow F10 was $27.9{\pm}1.8$. And Group 3 Beautifil flow F00 was $23.1{\pm}1.1$, Group 1 $Filtek^{TM}$ Z350 was $20.4{\pm}0.9$. There was a statistical significant difference in surface microhardness between all groups (p < 0.05). In conclusion, the compressive strength of giomer was below the level of flowable composite resin. However, the surface microhardness of giomer is comparable to that of flowable composite resin. Giomer would be the good alternative to composite resin, if there is improvement of the compressive strength of giomer.

Process Design of Cold Forged Hub by Flow Control Forming Technique (유동제어 성형기술을 이용한 허브제품의 냉간단조 공정설계)

  • Park, Jong-Nam;Kim, Dong-Hwan;Kim, Byung-Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.6
    • /
    • pp.86-95
    • /
    • 2002
  • This paper suggests the new technology to control metal flow in order to reduce the number of preforming and the machining for the cold forged product with complex geometry. This technology is the combined forming that consists of bulk and sheet forming with double action dies. To analyze the process, finite element simulation has been performed. The proposed technology is applied to hub model that is part of air conditioner clutch. The purpose of this study is to investigate the material now of hub through the relative-velocity control of punch and mandrel using the flow control forming technique.

Multi-Region Model of Solute Transport in Soil for the Preferential Flow (Preferential 흐름에 의한 토양내의 다영역 용질이동 모델)

  • 안병기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.2
    • /
    • pp.71-77
    • /
    • 2000
  • A multi-region model for solute transport through saturated soils has been developed to describe preferential flow. The model consists of numerous discrete pore groups, which are characterized by a discrete dispersion coefficient, flow velocity, and porosity . The hydraulic properties for each pore group are derived from a soil's hydraluic conductivity and soil water characteristic functions . Flow in pore group is described by the classical advection-disersion equation (ADE). An implict finite difference scheme was applied to the governing equation that results in a block-tridiagonal system of equations that is very efficient and allows the soil to be divided into any number of pore groups. The numerical technique is derived from methods used to solve coupled equations in fluid dynamics problems and can also be applied to the transport of interacting solutes. The results of the model are compared to the experimental data from published papers. This paper contributes on the characteristics of the method when applied to the parallel porosity model to describe preferential flow of solutes in soil.

  • PDF

EXTENSION OF CFD CODES APPLICATION TO TWO-PHASE FLOW SAFETY PROBLEMS

  • Bestion, Dominique
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.365-376
    • /
    • 2010
  • This paper summarizes the results of a Writing Group on the Extension of CFD codes to two-phase flow safety problems, which was created by the Group for Analysis and Management of Accidents of the Nuclear Energy Agency' Committee on the Safety of Nuclear Installations (NEA-CSNI). Two-phase CFD used for safety investigations may predict small scale flow processes, which are not seen by system thermalhydraulic codes. However, the two-phase CFD models are not as mature as those in the single phase CFD and potential users need some guidance for proper application. In this paper, a classification of various modelling approaches is proposed. Then, a general multi-step methodology for using two-phase-CFD is explained, including a preliminary identification of flow processes, a model selection, and a verification and validation process. A list of 26 nuclear reactor safety issues that could benefit from investigations at the CFD scale is identified. Then, a few issues are analyzed in more detail, and a preliminary state-of-the-art is proposed and the remaining gaps in the existing approaches are identified. Finally, guidelines for users are proposed.

Clinical study of the vasocreactivity and blood flow velocity of t he cerebral infarctions using Transcranial Doppler Sonography (Transcranial Doppler를 利用한 腦硬塞 患者의 血流速度와 血管 反應性에 대한 臨床的 考察)

  • Ann, Taek-won;Kim, Byeong-tak
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.11 no.1
    • /
    • pp.300-318
    • /
    • 1998
  • Background : The vasoreactivity of cerebral artery is currently the subject of increasing interest. Transcranial Doppler Sonography(TCD) is an accurate method of monitoring the blood flow velocities of the cerebral artery. We wished to assess the vasoreactivity between age-matched normal and cerebral infarction group. Method : We performed TCD findings in 40 normals and 20 cb-inf. subjects who arrived at hospital during 48 hours after attack. The former were devided into twenties normal group and fifties normal group. Result : 1. Fibrinogen levels showed significant changes between age-matched normal and cb-inf. group. 2. $V^{MEAN}$ of the both side Carotid Siphon during rest state increased significantly in cb-inf. group as compared with the age-matched normal group. 3. $V^{MEAN}and\;V^{MAX}$ of the both side carotid siphon during breath-hold state increased significantly in cb-inf. group as compared with the age-matched normal group. 4. Vasoreactivity of cerebral artery increased significantly in cb-inf. group as compared with the age-matched normal group. 5. $V^{MEAN}and\;V^{MAX}$ of the both side Radial artery during heat-stimuration state increased significantly in cb-inf. group as compared with the age-matched normal group. 6. Vasoreactivity of Radial artery increased significantly in cb-inf. group as compared with the age-matched normal group.

  • PDF

Free Cash Flow, Agency Conflicts, and Compensation Plans in a Non-growing Industry

  • Park, Sang-Bum
    • The Korean Journal of Financial Studies
    • /
    • v.10 no.1
    • /
    • pp.249-269
    • /
    • 2004
  • Free cash flow is known as a typical type of agency conflict between managers and shareholders in a firm. The insurance industry, which is not growing, is particularly susceptible to such excessive cash flow. We herein investigate the effects of stock ownership plans on reducing agency conflicts. We adopt undistributed cash flow to proxy free cash flow, and size, default risk, group membership, leverage, investment opportunity, and stock options are selected as explanatory variables. We find that stock option plans are effective(at a 10% level) in reducing free cash flow.

  • PDF

Analysis of Air Distribution in the Windbox System of the Utility Boiler (보일러 Windbox내 공기공급 계통의 유량분포 해석)

  • Park, Ho-Young;Kim, Sung-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.9
    • /
    • pp.581-589
    • /
    • 2008
  • The pulverized coal combustion behavior in the utility boiler is very complex since so many physical and chemical processes happen in it, simultaneously. The mixing of pulverized coal with combustion air plays an important role in achieving the efficient combustion and stable boiler operation. The distribution of combustion air supplied to the furnace through the windbox damper system has not been clearly known since the individual measurements of air flow for each air nozzle were not possible, yet. The present study describes the CFD modelling of windbox damper system and aims to obtain the air flow rates and pressure loss coefficients across the present five damper systems, respectively. The one dimensional flow network model has been also established to get air flow distributions across the windbox damper, and applied to the actual plant operation condition. Compared with the designed air flow distribution, the modelled one gives a reasonable agreement. For the actual plant operation, the predicted air flow distribution at each air nozzle is differed with the designed data and strongly affected by the individual opening angle.