• Title/Summary/Keyword: Group Combustion

Search Result 164, Processing Time 0.039 seconds

PAHs Source Fingerprints for Municipal Incinerator, Motor Vehicle Fuels and Industrial Boilers Emission (발생원별에 따른 PAHs 배출특성)

  • 박찬구;윤중섭;김민영;손종열;모세영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.3
    • /
    • pp.331-343
    • /
    • 2004
  • The results of individual PAH source profiles that can be applied to receptor model are as follows. The sum of 16 PAH concentrations was 391.41 ng/S㎥ in a tunnel. Phenanthrene was the most abundant compound among 16 PAH, and then pyrene, fluoranthene, anthracene, and naphthalene can be seen in elevated contents. 11,056.61 ng/S㎥ of 16 PAH concentrations in BC oil boiler was two times higher than 6,582.57 ng/S㎥) of those in LNG boiler. Naphthalene was the most abundant compound in both facilities. Phenanthrene, anthracene, and acenaphthylene were the second dominant compound group in order from both facilities. BC oil boiler had relatively high concentration of pyrene compared to LNG boiler that had high concentration of fluorene and did not detect pyrene. The sum of 16 PAH concentrations emitted from MSW incinerators after APCD (air pollution control device) was three times higher than those from MSW incinerators before APCD. However, the concentrations of more than 4-ring PAH compounds (e.g., benzo (a)anthracene) before APCD were higher than those after APCD. This fact implies that PAHs generated by combustion process are eliminated in APCD and they are continuously produced in stack or atmosphere by PAHs precursors.

The Effect of Turbulence Model on the Flow Field and the Spray Characteristics (유동장 및 분무특성에 미치는 난류모델의 영향)

  • 양희천;유홍선
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.1
    • /
    • pp.87-100
    • /
    • 1997
  • The ability of turbulence model to accurately describe the complex characteristics of the flow field and the fuel spray is of great importance in the optimum design of diesel engine. The numerical simulations of the flow field and the spray characteristics within the combustion chamber of direct injection model entgine are performed to examine the applicability of turbulence model. The turbulence models used are the RNG $\varepsilon$ model and the modified $\varepsilon$ model which included the compressibility effect due to the compression/expansion of the charges. In this study, the predicted results in the quiescent condition of direct injection model engine show reasonable trends comparing with the experimental data of spray characteristics, i. e., spray tip penetration, spray tip velocity. The results of eddy viscosity obtained using the $\varepsilon$ model in the spray region is significantly larger than that obtained using the RNG $\varepsilon$ model. The application of the RNG model seems to have some potential for the simulations of the spray characteristics, e. g., spray tip penetration, spray tip velocity, droplets distribution over the $\varepsilon$ model.

  • PDF

High Rate Performance of Li[Co0.50Li0.17Mn0.33]O2 Cathode (Li[Co0.50Li0.17Mn0.33]O2 양극물질의 고율 충방전 특성)

  • Park Yong-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.8
    • /
    • pp.737-743
    • /
    • 2006
  • [ $Li[Co_{0.50}Li_{0.17}Mn_{0.33}]O_2$ ] powder was prepared using a simple combustion method. specially, ratio of 2:1, 3:2, 1:1, 2:3, 1:2 was adopted as acetate source/nitrate source. The diffraction pattern of $Li[Co_{0.50}Li_{0.17}Mn_{0.33}]O_2$ powder showed that this compound could be classified as hexagonal $a-NaFeO_2$ structure (space group : $R\bar{3}m$). The size of powder was less than $1{\mu}m$. Small particle size of cathode powder would give a good ionic and electronic conductivity to cathode electrode, which made of cathode powder. As the increase of nitrate source-ratio, discharge capacity of $Li[Co_{0.50}Li_{0.17}Mn_{0.33}]O_2$ at high charge-discharge rate was increased. When the ratio of acetate source/nitrate source was 1:2, discharge capacity at 10 C rate (2000 mA/g) was 180 mAh/g. It was $10{\sim}15%$ larger than that of powder, which have 2:1 as acetate source/nitrate ratio.

An Economic Analysis on Dual-fuel Engine Generation for Peak Load (피크부하용 혼소엔진발전의 경제성 분석)

  • Lee, Ok-Bae;Ahn, Jae-Kyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1260-1268
    • /
    • 2012
  • Recently, lack of power reserve margin was observed quite often. In this paper, we studied the method to secure power source for a short time, to cut the utility power peak load, and to reduce the users electricity bills. Emergency diesel generator of an office building is to be converted into a dual-fuel engine generator which is responsible for a portion of the peak load. Compared to the conventional diesel fuel generator, the proposed dual-fuel engine is able to reduce the generation power cost by dual-fuel combustion, and it also mitigates the building's utility power peak load by charging the building's peak load. If the dead resources (a group of emergency dual-fuel engine generators), as a Virtual Power Plant, are operating in peak time, we can significantly reduce future large power development costs. We investigated the current general purpose electricity bills as well as the records of the building electric power usage, and calculated diesel engine generator renovation costs, generation fuel costs, driving conditions, and savings in electricity bills. The proposed dual-fuel engine generation method reduces 18.1% of utility power peak load, and turned out to be highly attractive investment alternative which shows more than 27% of IRR, 76 million won of NPV, and 20~53 months of payback periods. The results of this study are expected to be useful to developing the policy & strategy of the energy department.

Analysis on the Heat Exchange Efficiency of Kraft Recovery Boiler by Nose Arch Structure Using CFD (CFD를 활용한 크래프트 회수보일러 내부 노즈 아치 구조에 따른 열교환 효율 분석)

  • Jang, Yongho;Park, Hyundo;Lim, Kyung pil;Park, Hansin;Kim, Junghwan;Cho, Hyungtae
    • Applied Chemistry for Engineering
    • /
    • v.32 no.2
    • /
    • pp.149-156
    • /
    • 2021
  • A kraft recovery boiler produces steam for power generation by the combustion of black liquor from the kraft pulping process. Since saturated steam became superheated in a superheater above the furnace, it is important to increase the heat exchange efficiency for the superheated steam production and power generation. A nose arch at the bottom of the superheater is important for blocking radiation from the furnace which causes corrosion of the superheater. But the nose arch is the main reason for creating a recirculation region and then decreasing the heat exchange efficiency by holding cold flue gas after the heat transfer to saturated steam. In this study, the size of recirculation region and the temperature of flue gas at the outlet were analyzed by the nose arch structure using computational fluid dynamics (CFD). As a result, when the nose arch angle changed from 106.5° (case 1) to 150° (case4), the recirculation region of flue gas decreased and the heat exchange efficiency between the flue gas and the steam increased by 10.3%.

2-Dimensional Unsteady Modeling of Spray Flame Formed in a Laminar Counterflow Field - Effects of Equivalence Ratio and Fuel - (층류 대향류장에 형성된 분무화염의 2차원 비정상 모델링 -당량비 및 연료종에 관한 영향-)

  • Hwang, Seung-Min;Chung, Jin-Do;Seo, Byung-Min;Kim, Young-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.10
    • /
    • pp.933-940
    • /
    • 2009
  • To evaluate characteristics in spray flame, laminar counterflow is investigated on the effects of equivalence ratio and fuel by a two-dimensional DNS (direct numerical simulation). For the gaseous phase, Eulerian mass, momentum, energy, and species conservation equations are solved. For the disperse phase, all individual droplets are calculated by the Lagrangian method without the parcel model. n-Decane ($C_{10}H_{22}$) and n-heptane ($C_7H_{16}$) is used as a liquid spray fuel, and a one-step global reaction is employed for the combustion reaction model. As equivalence ratio increases, the fuel ignites early and the high temperature region spreads wider. The peak value of temperature, however, tends to once increase and then decreases with increasing equivalence ratio. The decrease in the peak value of temperature for the higher equivalence ratio condition is caused by the cooling effect associated with droplet group combustion. Since the evaporation of n-heptane is early, the high temperature region spreads wider than ndecane, but the peak values of temperature for both n-heptane and n-decane is almost same.

Development and Assessment of Harmful Gases Reducing Molded Fuel Using Torrefied Wood (반탄화목재를 이용한 유해가스 저감형 성형연료의 개발 및 평가)

  • LEE, Chang-Goo;EOM, Chang-Deuk;KIM, Min-Ji;KANG, Seog-Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.732-744
    • /
    • 2020
  • In this study, a torrefaction of Quercus serrata to manufacture a molded charcoal was performed, investigated material properties, fuel characteristics, and performed a quantitative analysis of hazardous gases which occur during a combustion process. In addition, a molded charcoal in market was selected as a control group, and a comparative analysis was performed. As a result, the higher heating value (HHV) of the torrefied specimen was about 14% higher than that of molded charcoal, and its ash content was about 51 times lower. Moreover, after performing a quantitative assessment of hazardous gases (carbon monoxide, nitrogen oxide, and sulfur dioxide) which were produced when each specimen was combusted for 900 seconds in an enclosed chamber, it was confirmed that the maximum value of generated amount of carbon monoxide on the torrefied specimen was about 50 times lower than that of the existing molded charcoal. Therefore, it was shown that the torrefied specimen produced in this study had a higher heating value than the molded charcoal in the market, and a very low amount of carbon monoxide generated during the combustion process.

Effects on Indoor Air Quality of Burning Chemicals (Scented Candles and Incense Sticks) (태우는 생활화학제품(향초와 인센스 스틱)의 사용이 실내 공기질에 미치는 영향)

  • Eun-Ah Park;Seungyeon Eo;Yerin Oh;Na-Youn Park;Myoungho Lee;Younglim Kho
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.1
    • /
    • pp.36-42
    • /
    • 2024
  • Background: The use of scented candles and incense sticks, both of which are household products that are burned for indoor deodorization and calming effects, is increasing. Fine dust has been designated as a group 1 carcinogen by the International Agency for Research on Cancer. Volatile organic compounds (VOCs) affect air pollution and can cause diseases. Objectives: This study aims to determine the effect on indoor air quality by measuring PM2.5 and VOCs generated when burning scented candles and incense sticks. Methods: Scented candles and incense sticks were selected as household products to burn. As for the target sample, top-selling products (five types of scented candles, five types of incense sticks) were purchased online. The PM2.5 concentration according to time was measured immediately next to the sample and three meters away from each other in an enclosed space using a real-time aerosol photometer. VOCs were collected as samples under the same conditions using Tenax tubes and were quantitatively analyzed by TD-GC/MS. Results: In the case of scented candles, the concentration of PM2.5 did not increase during combustion and after being extinguished by placing a cover on the candle. For the incense sticks, the concentration of PM2.5 averaged 1,901.27 ㎍/m3. After burning scented candles and incense sticks, some VOCs concentrations were increased such as ethyl acetate and BTEX (benzene, toluene, ethylbenzene, xylene). Conclusions: Therefore, when using scented candles, extinguishment by placing a cover on the candle can be expected to reduce PM2.5. It is advisable to avoid using incense sticks because PM2.5 concentration increases from the start of combustion.

Enrichment of $CO_2$-Fixing Bacteria in Cylinder-Type Electrochemical Bioreactor with Built-In Anode Compartment

  • Jeon, Bo-Young;Jung, Il-Lae;Park, Doo-Hyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.21 no.6
    • /
    • pp.590-598
    • /
    • 2011
  • Bacterial assimilation of $CO_2$ into stable biomolecules using electrochemical reducing power may be an effective method to reduce atmospheric $CO_2$ without fossil fuel combustion. For the enrichment of the $CO_2$-fixing bacteria using electrochemical reducing power as an energy source, a cylinder-type electrochemical bioreactor with a built-in anode compartment was developed. A graphite felt cathode modified with neutral red (NR-graphite cathode) was used as a solid electron mediator to induce bacterial cells to fix $CO_2$ using electrochemical reducing power. Bacterial $CO_2$ consumption was calculated based on the variation in the ratio of $CO_2$ to $N_2$ in the gas reservoir. $CO_2$ consumed by the bacteria grown in the electrochemical bioreactor (2,000 ml) reached a maximum of approximately 1,500 ml per week. Time-coursed variations in the bacterial community grown with the electrochemical reducing power and $CO_2$ in the mineral-based medium were analyzed via temperature gradient gel electrophoresis (TGGE) of the 16S rDNA variable region. Some of the bacterial community constituents noted at the initial time disappeared completely, but some of them observed as DNA signs at the initial time were clearly enriched in the electrochemical bioreactor during 24 weeks of incubation. Finally, Alcaligenes sp. and Achromobacter sp., which are capable of autotrophically fixing $CO_2$, were enriched to major constituents of the bacterial community in the electrochemical bioreactor.

Effects of Oxidation Process on Thermal Properties of Petroleum-based Isotropic Pitch (산화 공정이 석유계 등방성 피치의 열거동 특성에 미치는 영향)

  • Lee, Namji;Seo, Sang Wan;Kwak, Cheol Hwan;Kim, Min Il;Im, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • v.31 no.1
    • /
    • pp.36-42
    • /
    • 2020
  • In order to investigate the effect of the oxidation process on thermal properties of the pitch, the oxidized pitch was prepared by changing the oxidation temperature. Thermal properties of the pitch were analyzed using thermogravimetric analysis (TGA), and it divided into three sections as A (25~100 ℃), B (250~550 ℃) and C (550~800 ℃) by derivative thermogravimetry (DTG) graph behavior. In the A section, the was reduced because the moisture contained in the pitch was removed. In the B section, as the oxidation temperature increased, the thermal stability of the pitch is improved. Because the degree of aromaticity and molecular weight of the pitch increased with increasing oxidation temperature. In contrast, the results of the C section were shown opposite of B section. Because the introduced C-OH, C-O-C, and C=O bonds were decomposed, and the resulting oxygen compounds induced the combustion reaction of the pitch.