• Title/Summary/Keyword: Groundwater wells temperatures

Search Result 9, Processing Time 0.017 seconds

Time Series Change Characteristics of Unconfined Groundwater Wells Temperatures for Agricultural Water Use (농업용수 활용을 위한 비피압지하수관정 수온의 시계열 변동특성)

  • Park, Seung Ki;Jung, Nam Su
    • Journal of Korean Society of Rural Planning
    • /
    • v.22 no.1
    • /
    • pp.13-23
    • /
    • 2016
  • There is a need to analyze unconfined groundwater behavior since the demand of groundwater use has been increasing. While unconfined groundwater temperature is tend to be affected by air temperature, it is hard to find an empirical study in South Korea. In this research, we try to determine the relationship between daily average air temperature and daily average groundwater temperature by time-sequential analysis of groundwater monitoring wells in Galshin basin in Yesan-Gun, Chungcheongnam-Do. In addition, models to estimate groundwater temperature from air temperature were developed. In this research 101-day moving average method with measured air temperature is used to estimate groundwater temperature. To verify the developed model, estimated values of average groundwater temperature with 101 moving average are compared to the measured data from September 10 2007 to September 9 2008. And, Nash-Stucliff Efficiency and Coefficient of Determination were 0.970 and 0.976, therefore it was concluded that the model allowing groundwater temperature estimation from air temperature is with reasonable applicability.

Assessment of geothermal potential in an area of sulfate-rich hot springs, Bugok, southern Korea

  • Park Seong-Sook;Yun Seong-Taek;Chae Gi-Tak;So Chil-Sup;Koh Yong-Kwon;Choi Hyeon-Su
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.303-306
    • /
    • 2006
  • Using a variety of chemical geothermometers we estimate the temperature of a deep geothermal reservoir in relation to thermal groundwater in the Bugok area, southern Korea, in order to assess the potential use of geothermal energy in South Korea. Thermal water at Bugok has been exploited down to about 400 m below the land surface and shows the highest outflow temperatures (up to $78{\circ}C$) in South Korea. Based on the hydrochemical data and occurrence, groundwater in Bugok can be classified into three groups: $Na-SO_4$ type thermal groundwater (CTGW) occurring in the central part (about 0.24 $km^2$) $Ca-HCO_3$ type cold groundwater (SCGW) occurring in shallow peripheral parts of CTGW; and the intermediate type groundwater (STGW). CTGW waters are typical of thermal water in the area, because they have the highest outflow temperatures and contain very high concentrations of Na, K and $SiO_2$ due to the sufficient reaction with silicate minerals in deep reservoir. Their enriched $SO_4$ was likely formed by gypsum dissolution. The major ion composition of CTGW shows the general approach to a partial equilibrium state with rocks at depth. The application of various alkali ion geothermometers yields temperature estimates in the range of 88 to $198{\circ}C$ for the thermal reservoir. Multiple mineral equilibrium calculation indicates asimilar but narrower temperature range between about 100 and $155{\circ}C$. These temperature estimates are not significantly higher than the measured outflow temperatures for CTGW Considering the heat loss during the ascent- of thermal waters, this fact may suggest that a thermal reservoir in the study area is likely located at relatively shallow depths (possibly close to the depth of preexisting wells). Therefore, we suggest a high potential for geothermal energy development around the Bugok area in southern Korea.

  • PDF

Parametric and Non-parametric Trend Analysis of Groundwater Data Obtained from National Groundwater Monitoring Stations (국가 지하수관측소 지하수위, 전기전도도 및 수온자료에 대한 모수적 및 비모수적 변동 경향성 분석)

  • Lee, Jin-Yong;Yi, Myeong-Jae;Lee, Jae-Myeong;Ahn, Kyoung-Hwan;Won, Jong-Ho;Moon, Sang-Ho;Cho, Min-Joe
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.2
    • /
    • pp.56-67
    • /
    • 2006
  • Trends of variation in groundwater levels, electrical conductivities and water temperatures obtained from the national groundwater monitoring stations (95 shallow and 169 deep wells) of Korea were evaluated. For the analysis, both parametric (linear regression) and non-parametric (Mann-Kendall test, Sen's test) methods were adopted. Results of linear regression analysis indicated that about 50% of the monitoring wells showed increasing trends of groundwater levels, electrical conductivities, and water temperatures and the others showed decreasing trends. However, the non-parametric analyses with monthly median values revealed that $14.8{\sim}20.0%$ of water levels were decreased, $24.2{\sim}36.9%$ of electrical conductivities were increased, and $27.4{\sim}32.5%$ of water temperatures were increased at a confidence level of 99%. Highly proportions of increasing or decreasing trends were unexpected and they resulted from the relatively short term of data collection (maximum 6 years). Meanwhile, the investigation of groundwater around the national groundwater monitoring stations showed that the decreasing or increasing trends of water levels, electrical conductivities, themselves, didn't indicate directly groundwater hazards such as groundwater depletion or groundwater contamination. Both the values and variation rates (slopes) of water level, electrical conductivity and temperature in the longer period are considered simultaneously. This study is the first comprehensive work in analyzing trends of groundwater data obtained from the national groundwater monitoring stations. Based on this study, the periodical and regular analysis of groundwater data is essentially required to grasp the overall variational trend of groundwater resources in the country.

A Study on Significant Parameters for Efficient Design of Open-loop Groundwater Heat Pump (GWHP) Systems (개방형 지열시스템의 효율적 설계를 위한 영향인자에 대한 연구)

  • Park, Byeong-Hak;Joun, Won-Tak;Lee, Bo-Hyun;Lee, Kang-Kun
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.41-50
    • /
    • 2015
  • Open-loop groundwater heat pump (GWHP) system generally has benefits such as a higher coefficient of performance (COP), lower initial cost, and flexible system size. The hydrogeological conditions in Korea have the potential to facilitate the use of the GWHP system because a large number of monitoring wells show stable groundwater temperatures, shallow water levels, and high well yields. However, few studies have been performed in Korea regarding the GWHP system and the most studies among them dealt with Standing Column Well (SCW). Because the properties of the aquifer have an influence on designing open-loop systems, it is necessary to perform studies on various hydrogeological settings. In this study, the hydrogeological and thermal properties were estimated through various tests in the riverside alluvial layer where a GWHP system was installed. Under different groundwater flow velocities and pumping and injection rates, a sensitivity analysis was performed to evaluate the effect of such properties on the design of open-loop systems. The results showed that hydraulic conductivity and thermal dispersivity of the aquifer are the most sensitive parameters in terms of performance and environmental aspects, and sensitivities of the properties depend on conditions.

Evaluation of Long-term Data Obtained from Seawater Intrusion Monitoring Network using Variation Type Analysis (변동유형 분석법을 이용한 해수침투 관측망 자료 평가)

  • Song, Sung-Ho;Lee, Jin-Yong;Yi, Myeong-Jae
    • Journal of the Korean earth science society
    • /
    • v.28 no.4
    • /
    • pp.478-490
    • /
    • 2007
  • With groundwater data of seawater intrusion monitoring network in coastal areas of Korea's main land, we analyzed types of seawater intrusion through the coastal aquifer. The data including groundwater level, temperature and electrical conductivity obtained from 45 monitoring wells at 25 watershed regions were evaluated. Based on statistical analysis, correlation analysis and variation type analysis, groundwater levels were mainly affected by rainfall and artificial pumping. About 78% of the monitoring wells showed average temperature higher than $15^{\circ}C$ and about 58% of them showed minimum variations less than $0.2^{\circ}C$. Electrical conductivities showed a large magnitude of variation and irregular characteristics compared with groundwater levels and temperatures. Average electrical conductivities lower than $2,000\;{\mu}S/cm$ were observed at 28 monitoring wells while those of higher than $10,000\;{\mu}S/cm$ were done at 9 monitoring wells. From the cross-correlation analysis, groundwater levels were mostly affected by precipitation while temperature and electrical conductivity showed very low correlation. Meanwhile tidal variations strongly affected the groundwater levels comparing to precipitation. We classified the long-term monitoring data according to variation types such as constant process, linear trend, cyclic variation, impulse, step function and ramp. Impulse type was dominant for variations of groundwater level, which was largely affected by rainfall or artificial pumping, the constant process was dominant for temperature. Compared with groundwater level and temperature, electrical conductivities showed various types like linear trend, step function and ramp. According to the discrepancy of variation characteristics for monitoring data at each well in the same region, periodical analysis of monitoring data is essentially required.

국내 대륙붕 및 육상에 분포하는 탄화수소 가스의 지화학

  • 이영주;정태진;곽영훈;김학주;윤혜수
    • 한국석유지질학회:학술대회논문집
    • /
    • autumn
    • /
    • pp.40-49
    • /
    • 1999
  • The chemical compositions of natural gases and isotopic compositions of hydrocarbon gases were analyzed to characterize the properties of the gases which were found in the exploratory wells from offshore Korea, as well as those dissolved in the ground water onshore in the Pohang area. Natural gases from the offshore area mainly consisted of hydrocarbon gases $(97.98{\~}100{\%})$. The gases were composed of methane $(90{\~}96{\%})$ and minor amounts of heavier components up to $C_{6+}$ Hydrocarbon gases extracted from the groundwater in the Pohang area consisted of methane $(27{\~}376420 ppm)$ and ethane $(19{\~}127 ppm)$. The total amount of hydrocarbon gases was related to the lithology and geological factors surrounding the reservoir. The quantity of the hydrocarbon gases tended to Increase in the Tertiary reservoirs and in the reservoirs where the Tertiary formations were thickly distributed. According to the methane contents, composition of hydrocarbon gases, and stable isotope data, gases from offshore wells are identified as thermogenic in origin, generated during catagenesis stage of the oil window. On the otherhand, based on the methane content $(>99.9\%)$ and isotopic composition $(\delta^{13} C^;\; -73.1{\sim}\;-43.22{\%}_{\circ})$, it is interpretated that the gases from the Pohang area are predominantly composed of biogenic origins, which were generated by the methanogenic bacterial processes under low temperatures and anoxic conditions.

  • PDF

The Analysis of Geothermal Gradient at Icheon Hot Spa Area (이천 온천원보호지구의 지온경사 해석)

  • Lee, Chol-Woo;Moon, Sang-Ho
    • The Journal of Engineering Geology
    • /
    • v.18 no.2
    • /
    • pp.185-190
    • /
    • 2008
  • Nine wells have been developed for uses of thermal waters at the Icheon hot spa area. Drilling depths of those hot spring wells range from 166 to 294 m and their piezometric heads are located at about 50 m below the surface. Using the differences between the surface and bottom temperatures within all boreholes, we can simply estimate geothermal gradient in this area. Thus, we obtained the highest, lowest and average gradient values as $64^{\circ}C/km$ from SB-2 well, $45^{\circ}C/km$ from SB-1 well and approximately $54.28^{\circ}C/km$, respectively. However, observing the MRD-2 well additionally drilled into the depth of 996 m, we found out that this study area has widely experienced the temperature disturbance due to thermal groundwater penetration through the fracture systems within the depth of 720 m. Unlikely this phenomenon, we can conclude that the groundwater flow below the depth of 720 m does not exist. Therefore, using only those temperature data below the 720 m depth, we can estimate reasonable geo-thermal gradient values as $33^{\circ}C/km$ in this study area. Pumping test shows that outflowing temperature is $36^{\circ}C$ corresponding to the temperature logging data at 720 m depth.

Analysis of Groundwater Use and Discharge in Water Curtain Cultivation Areas: Case Study of the Cheongweon and Chungju Areas (청원-충주지역 수막재배용 지하수 사용량 및 배출량 분석)

  • Moon, Sang-Ho;Ha, Kyoochul;Kim, Yongcheol;Yoon, Pilsun
    • The Journal of Engineering Geology
    • /
    • v.22 no.4
    • /
    • pp.387-398
    • /
    • 2012
  • Korean agricultural areas that employ water curtain cultivation (WCC) have recently suffered extensive groundwater shortages due to an increase in the number of facilities. The primary focus of this study is to measure the daily groundwater use and discharge rates in the Cheongweon and Chungju pilot areas, while the second focus is to estimate the total amount of groundwater used in WCC areas nationwide in Korea. Taking into consideration several factors, including motor type, outflow abilities of wells, records of daily minimum temperatures below $0^{\circ}C$, and the number of running wells according to weather variations, we estimated that $53,138m^3/ha$ of groundwater had been used in the 4-hectare Cheongweon pilot area during the winter period of late 2011 through early 2012. On a prorated areal basis, we can calculate that the total groundwater used nationwide was 0.57 billion $m^3$ in WCC areas of $10,746m^2$. This value is equivalent to 33.7% of the total agricultural groundwater use (1.69 billion $m^3$) in Korea. During 9-22 February 2012, the daily water discharge rate in the 4-ha Cheongweon pilot area ranged from 2,079 to $2,628m^3$, averaging $2,341m^3$. Combining this value with meteorological records for 94 days with a daily minimum temperature below $0^{\circ}C$ results in an estimated groundwater volume of $54,990m^3/ha$ for the pilot area during the 2011-2012 winter period. The total amount of groundwater used nationwide in WCC areas would then be 0.59 billion $m^3$, equivalent to 34.9% of the total agricultural groundwater use in Korea. In the Chungju area, the groundwater discharge rate was estimated to be less than 805 $m^3$/ha. This value, combined with weather data for 108 days with a daily minimum temperature below $0^{\circ}C$ in this area, can be applied to infer that the total groundwater volume used in WCC areas nationwide is no more than 55% of the total agricultural groundwater use in Korea.

A Study on Development Potential of Shallow Geothermal Energy as Space Heating and Cooling Sources in Mongolia (몽골의 천부 지열에너지(냉난방 에너지)개발 가능성에 관한 연구)

  • Hahn, Jeong-Sang;Yoon, Yun-Sang;Yoon, Kern-Sin;Lee, Tae-Yul;Kim, Hyong-Soo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.36-47
    • /
    • 2012
  • Time-series variation of groundwater temperature in Mongolia shows that maximum temperature is occured from end of October to the first of February(winter time) and minimum temperature is observed from end of April to the first of May(summer time). Therefore ground temperature is s a good source for space heating in winter and cooling in summer. Groundwater temperatures monitored from 3 alluvial wells in Ulaabaatar at depth between 20 and 24 m are $(4.43{\pm}0.8)^{\circ}C$ with average of $4.21^{\circ}C$ but mean annual ground temperature(MAGT) at the depth of 100 m in Ulaanbaatar was about $3.5{\sim}6.0^{\circ}C$. Bore hole length required to extract 1 RT's heat energy from ground in heating time and to reject 1 RT's heat energy to ground in summer time are estimated about 130 m and 98 m respectively. But in case that thermally enhanced backfill and U tube pipe placement along the wall are used, the length can be reduced about 25%. Due to low MAGT of Ulaabaatar such as $6^{\circ}C$, the required length of GHX in summer cooling time is less than the one of winter heating time. Mongolia has enough available property, therefore the most cost effective option for supplying a heating energy in winter will be horizontal GHX which absorbs solar energy during summer time. It can supply 1 RT's ground heat energy by 570 m long horizontally installed GHX.