• Title/Summary/Keyword: Grounding accident

Search Result 44, Processing Time 0.024 seconds

A study on the Grounding method for reduce an interference by CATV Transmission Line (CATV 전송선로의 간섭을 줄이기 위한 접지방식에 관한 연구)

  • Hwang, Jong-Sun;Yon, Che-Chin;Park, Sung-Jin;Kim, Yeong-Min
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.57-60
    • /
    • 2001
  • CATV is the abbreviation for Cable Television. General CATV is a way of multi-channel sending images, voices and music including stillness image as well as characters to public receivers through electrical cable communication system. In the beginning, master antennas were people can not receive TV signal well. TV programs were received from master antennas to TVs in each house. Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in CATV.

  • PDF

A study on the Grounding method for reduce an interference by CATV Transmission Line (CATV 전송선로의 간섭을 줄이기 위한 접지방식에 관한 연구)

  • 황종선;연제진;박성진;김영민
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.57-60
    • /
    • 2001
  • CATV is the abbreviation for Cable Television. General CATV is a way of multi-channel sending images, voices and music including stillness image as well as characters to public receivers through electrical cable communication system. In the beginning, master antennas were people can not receive TV signal well. TV programs were received from master antennas to TVs in each house. Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in CATV.

  • PDF

A Study on the Integrated Monitoring of a Leakage Current of the Grounding Wire of Neutral Point of the Low Voltage Side of Transformer (변압기 저압측 중성점 접지선의 누설전류 통합 감시에 관한 연구)

  • Hong, Soon-Seuk;Park, Joon-Yeol;Lee, Jung-Eun;Choi, Kyung-Han
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.106-113
    • /
    • 2010
  • If leakage current is neglected, it can become a cause for disasters such as electric shock and fire, therefore a continuous monitoring is necessary. However in most cases, because management of substations is performed by unmanned systems, or walk-around inspections, continuous monitor is difficult. So when an accident occurs and the cause is not immediately resolved causing the emergency generator's OCGR getting activated by the leakage current that in turn cut off the ACB, the emergency generator may stop working. To prevent such a problem, a real-time integrated monitoring system for monitoring the leakage current returning to the grounding wire of neutral point of the low voltage side of transformer is proposed. Therefore in this paper, the effects of flow of leakage current, which is caused by insulation degradation phenomena or insulation destroy phenomena, were identified by simulation. And through cases studies; the excellence of integrated monitoring system was verified.

Risk Analysis of Electrical Fire for Electric Power Installations by Event Tree Analysis (사건수목분석을 통한 수배전설비의 전기화재위험성 분석)

  • Park, Young Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.16-21
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on 15 components of power installations: the DS/LBS, LA, MOF, CT, PT, A/V meter, VCB, OCR, COS, PF, Transformer, Condenser(C), Grounding, Cable and Connector. To achieve that, power installations work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew Initiation events (IE) and End states (ES). ETA is applied to the main functions of each component, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events. If the suggested IEs and ESs are applied on the basis of power installations event cases, it is expected to prevent the same kinds of accident and operate power installations safely.

A Study on the In-depth Analysis of Cause and Characteristic for Recent Electric Shock Accident (최근 감전재해의 발생특성과 재해원인 분석연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.7-11
    • /
    • 2014
  • The electric shock victims were predominantly male, and more than half of the victims were found in companies with less than five employees in terms of the scale of company, and also more than half of victims had less than one month of experience for work experience. Considering the category of industry, more than half of the victims were engaged in construction, and considering the subcategory of industries, more than 60% of electric shock victims were found in building and other construction works. This study intended to conduct an in-depth analysis on the cause of electric shock accidents to provide basic data for policy proposing taking into considering the characteristics such as the electric shock path, low voltage, grounding and protection of workers. Also this study conducted an in-depth analysis of electric shock accidents for the past eleven years taking into account the necessity of a long-term plan.

A Study on the Countermeasure to the Stray Current in Underground (지중 표유전류 저감 대책에 관한 연구)

  • Bae, J.H.;Kim, D.K.;Ha, T.H.;Lee, H.G.;Choi, S.B.;Jeong, S.H.;Kim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1159-1162
    • /
    • 1998
  • The induced voltage of underground pipelines caused by the stray current not only do harm to workers and instruments. but also cause big accident such as gas explosion. The AC stray current is mainly produced by the grounding system of the 22.9kV distribution power system and the DC stray current is mainly produced by the subway system. The mechanism of AC and DC induction, stray current failure examples of domestic and foreign countries and the countermeasure of the AC and DC induction are described.

  • PDF

A Study on New Data Format of Electrical Shocks in the Environment of Smart Grids (스마트 그리드 환경에서의 전기 감전 재해 자료 형태에 관한 연구)

  • Kim, Jung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.486-491
    • /
    • 2011
  • Since Korea has high accident rate for the electrical shock than other advanced countries, it causes very serious problems. In this paper, a new classification method for analyzing electricity accidents is proposed, which is based on the microscopic view while existing methods have been based at the macroscopic view point. Electrical accidents cases can be mainly divided by three cases, which are from live works, incompleteness of the grounding system and imperfectness of the safety education and public relations. New data format of electrical shocks are proposed in the environment of smart grids.

Grounding method for Improving of the Characteristics on Cable TV Transmission Line (케이블 TV 전송선로의 특성 개선을 위한 접지방식)

  • Hwang, Jong-Sun;Kim, Yeong-Min;Yeon, Che-Chin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.37-40
    • /
    • 2002
  • Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in cable TV.

  • PDF

A Study on a Method to Reduce Marine Pollution Accidents through Tugboat Grounding - Focusing on an Experiment of Indicating the Location of Stranded Accidents on GPS Plotters - (예인선 좌초에 의한 해양오염사고 감소방안에 관한 연구 - GPS 플로터에 좌초사고 위치표시 실험을 중점으로 -)

  • Kim, Do-Hoon;Kang, Woo-Kyung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.29-37
    • /
    • 2021
  • In the event of a marine pollution accident, Korea, which is bordered by the sea on three sides, would suffer tremendous damage. According to an analysis of marine pollution accidents in Korea, most pollutants were small fishing boats and tugboats. In particular, urgent safety measures are required due to the high incidence of marine pollution accidents caused by stranded tugboats. This study aims to decrease secondary marine pollution accidents by preparing measures to prevent accidents by stranded tugboats, the main source of pollution accidents. To this end an experiment was conducted to mark 63 locations where stranded accidents have occurred on the GPS plotters of 61 tugboats operating in Boryeong sea area. Its effectiveness was then investigated. The result showed that there was no stranded accident by the subject ship during the 20-month experiment period. As a result of survey of the captains, 36 out of 40 respondents (90%) stated that the experiment was significantly helpful in ensuring safe navigation, thus confirming its effectiveness. Various measures were proposed to prevent stranded accidents, including providing information to manufacturers and users by marking the location of grounded accidents on GPS plotters and posting the location information of unknown reefs on the official website of institution Korea Hydrographic and Oceanographic Agency.

Analysis of Workload of the Domestic Coastal Ship Duty Officer to Prevent Marine Accidents (해양사고 예방을 위한 국내 연안선 항해당직자의 업무 부하 분석)

  • Yang, Young Hoon;Kim, Hongtae;Jang, Junhyuk
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.579-587
    • /
    • 2017
  • Objective: The purpose of this study is to measure the workload of Korea coastal ship crew members, to investigate whether they are following work-break time regulations and to identify the main causes of their workload. Background: According to the US Coast Guard, about 33% of human casualties are reported to be due to fatigue, and 30% of marine casualties reported by the British Marine Accident Investigation Agency (MAIB) are attributed to crew fatigue. But the coastal ship are not managed for business hours and breaks despite the harsh environment. Method: The workload of duty crew members on the 100 domestic coastal vessels was measured. It was also investigated whether they are following domestic and international work-break time regulations. Finally, the marine accidents resulted from the fatigue of the crew was analyzed. Results: As a result of workload analysis, the workload on the 42~62% of the vessels exceeded the standard of working time on the related regulation. The workload increased with the number of inbound and outbound ports. Especially, in the system where there are two seafarers, the workload exceeded the working time requirement. As a result of the marine accidents analysis on 100 vessels, it was found that collision and grounding occurred due to fatigue, workload and drowsiness in 7 marine accidents out of 30 marine accidents. Conclusion: It is necessary for the shipping companies to introduce an operation management manual for the management of the crews' workload and reasonable crew arrangement. It is also required for crew members to easily record work times and for shipping companies to manage the record. It would be possible to prevent many marine accidents by providing adequate rest to the crews and flexibly adjusting their working hours. Application: The results of this study can be used as fundamental data to manage crews' fatigue and to make job management manuals.