• 제목/요약/키워드: Ground-source heat pump(GSHP)

검색결과 109건 처리시간 0.021초

지열히트펌프 시스템의 국내 적용현황 조사 및 분석 (Investigation and Analysis on the present state of Geothermal Source Heat Pump System Applied in Korea)

  • 최미영;고명진;김용식;박진철;이언구
    • 설비공학논문집
    • /
    • 제21권5호
    • /
    • pp.267-272
    • /
    • 2009
  • This study aims to investigate and analyze the present state of ground source heat pump(GSHP) system applied in Korea. It is based on the statistic from the New and Renewable Energy Center in Korea and construction results of the professional companies registered to the center. The research items were installed area, installed year, building use, ground heat exchange type and heat exchanger type of the pump. According to the result of investigation, the using GSHP system have been increasing steadily as the space heating and cooling system in a building. The capacity of this system is also becoming lager based on technical and economical feasibility analysis about the system since GSHP system first introduced in 2000.

수치해석을 통한 저심도 유닛형 지중열교환기의 성능 검토 (Performance Analysis of a Low-Depth Unit-Type Ground Heat Exchanger using Numerical Simulation)

  • 오진환;서장후;남유진
    • 설비공학논문집
    • /
    • 제27권3호
    • /
    • pp.169-173
    • /
    • 2015
  • Recently, ground source heat pump (GSHP) systems have attracted much attention, according to the enhanced social demand of renewable energy. GSHP systems can achieve higher coefficient of performance than the conventional air-source heat pump systems by utilizing stable underground temperature. However, the initial cost of GSHP system is higher than that of the conventional systems, especially, in the small-size buildings. Therefore, it is necessary to develop small-size ground heat exchanger with low cost and quick installation. In this study, a unit-type ground heat exchanger was developed and heat exchange rate was calculated by the numerical simulation. As a result, 27.45 W/m of heat exchange rate was acquired in the condition of $0.5m{\times}0.2m{\times}2m$ unit.

저심도 지중열교환기 개발을 위한 그라우트 재료에 따른 채열성능 검토 연구 (The Performance Analysis for Low-Depth Unit-type Ground Heat Exchanger According to Grouting Materials)

  • 오진환;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권2호
    • /
    • pp.7-11
    • /
    • 2015
  • Recently, as the demand for sustainable energy sources is increasing, ground-source heat pump (GSHP) systems are receiving growing attention. However, the initial cost of GSHP system is higher than it of the conventional systems, especially, in small-size buildings. Therefore, for the application to the small-size building, it is necessary to develop small-size ground heat exchanger with small-size buildings. In this study, analysis of unit-type heat exchanger due to grouting materials. As a result, 1492.14 W of heat exchange rate was acquired in the condition of cement-silica sand-graphite materials.

지열 이용 열펌프 시스템의 열성능 해석 (Analysis of Thermal Performance of Ground-Source Heat Pump System)

  • 고득용;신우철;백남춘;김욱중
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.167-172
    • /
    • 2005
  • The purpose of this study is to present the simulation results and an overview of the performance assessment of the Ground-Source Heat Pump(GSHP) system. The calculation was performed for two design factors. the spacing between boreholes and the depth of the vertical ground heat exchangers. And the simulation was carried out using the thermal simulation code TRNSYS with new model o( water to water heat pump developed by this study. As a result, it was anticipated that the yearly mean COPs of heat pump for heating and cooling are about 3.7 and 5.8 respectively and the heat pump can supply 100% of heating and cooling load all the year around.

  • PDF

지열 냉난방 시스템의 성능 및 경제성 평가 (Performance Evaluation and Economic Estimation of Ground Source Heat Pump Cooling and Heating System)

  • 임효재;송윤석;공형진;박성구
    • 에너지공학
    • /
    • 제13권4호
    • /
    • pp.296-300
    • /
    • 2004
  • 본 연구는 지열원 물 대 물(water to water)히트 펌프 시스템의 냉방 및 난방 운전시 성능 특성과 경제성 평가에 관한 것이다. 5개의 보어홀당 지중 100m의 깊이로 밀폐 수직형 지중 열교환기(closed-vertical ground source)가 설치된 냉난방 시스템이 적용된 건축물에 대하여 냉난방 운전성능을 평가하였으며, 연간 소비전력을 측정하여 실제 시스템의 경제성을 분석하였다. 또한, 순환수의 입구온도에 따른 시스템의 운전 성능을 분석한 결과 난방시에는 COP가 3.0에서 4.2로 증가한 반면, 냉방시에는 5.0에서 3.7로 감소하였다. 본 실험을 통해서,대상 건축물에 대한 지열 냉난방 시스템의 수명주기비용은 기존 냉난방 시스템(보일러+에어컨)에 비해서 68%까지 절감되었으며, 시스템의 경제성을 고려해 볼 때 기존 건축물에도 지열원 냉난방 시스템을 적용하는 것이 타당하다.

단독주택용 지열 열펌프 시스템의 경제성과 이산화탄소 배출 저감 가능성 평가 (Assessing the Economic and $CO_2$ Emission Reductions Viability of Domestic Ground-Source Heat Pumps)

  • 손병후;강신형
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.64-69
    • /
    • 2009
  • Because of their low operating and maintaining costs, ground-source heat pump(GSHP) systems are an increasingly popular choice for providing heating, cooling and water heating to public and commercial buildings. Despite these advantages and the growing awareness, GSHP systems to residential sectors have not been adopted in Korea until recently. A feasibility study of a residential GSHP system was therefore conducted using the traditional life cycle cost(LCC) analysis within the current electricity price framework and potential scenarios of that framework. As a result, when the current residential electricity costs for running the GSHP system are applied, the GSHP system has weak competitiveness to conventional HVAC systems considered. However, when the operating costs are calculated in the modified price frameworks of electricity, the residential GSHP system has the lower LCC than the existing cooling and heating equipments. The calculation results also show that the residential GSHP system has lower annual prime energy consumption and total greenhouse gas emissions than the alternative HVAC systems considered in this work.

  • PDF

GSHP용 수직형 지중열교환기의 열전달 성능에 관한 연구 (A Study on Heat Transfer Performance of Vertical Ground Heat Exchanger of GSHP(Ground Source Heat Pump))

  • 정민호;장기창;나호상;백영진;박성룡;유성연
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2102-2107
    • /
    • 2007
  • GSHP systems are used for air-conditioning systems in commercial buildings, schools, and factories because of low operating and maintenance costs. These systems use the earth as a heat source in heating and a heat sink in cooling mode. Ground heat exchangers are classified by a horizontal and vertical type according to the installation method. Vertical type is usually constructed by placing small diameter high density polyethylene tube in a vertical borehole. Vertical tube sizes range from 20 to 40 mm nominal diameter. Borehole depth range between 100 and 200 m depending on local drilling conditions and available equipment. In this study, to evaluate the performance of single u-tube with bentonite grouting, single u-tube with broken stone grouting and double u-tube bentonite grouting of vertical ground heat exchangers, test sections are buried on the earth and experimental apparatus is installed. Therefore the heat transfer performance and pressure loss of these are estimated.

  • PDF

IEA ECBCS Annex 54 방법에 근거한 PVT-GSHP 시스템 경제성 평가 연구 (PVT-GSHP System Economic Evaluation Study with IEA ECBCS Annex 54 Method)

  • 박진우;강은철;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.64-71
    • /
    • 2014
  • This study is to perform economic analysis of a PVT-GSHP (Photovoltaic Thermal-Ground Source Heat Pump) system compared to the conventional system which consists of a boiler and a chiller. This research has simulated, developed and analyzed four systems for application in a residential and an office building which was based on the hourly EPI (Energy Performance Index, $kWh/m^2yr$). Case 1 includes a boiler and a chiller to meet heating and cooling demands for a house. Case 2 is the same conventional system as Case 1 for a office. Case 3 is simple summation of Case 1 and 2. And Case 4 is utilizing a PVT-GSHP to meet the combined loads of the house and office. The economic evaluation study was based on IEA ECBCS Annex 54 subtasks C economic assessment methods. This study indicated that PVT-GSHP system can save a building's energy up to 53.9%. Also the SPB (Simple Payback) of the PVT-GSHP system with 0%, 50% initial incentive was 14.5, 6.7 year respectively.

지역 기후가 유닛형 지중열교환기 성능에 미치는 영향 (Analysis on the Effect of Local Climate on the Unit-type Ground Heat Exchanger)

  • 배상무;김재민;남유진
    • 한국태양에너지학회 논문집
    • /
    • 제39권1호
    • /
    • pp.67-76
    • /
    • 2019
  • A ground source heat pump (GSHP) system can stable system operation by using underground heat source and has high reliability for energy production. However, wide-spread of the GSHP system is delayed to high initial investment costs. In previous studies, horizontal and unit-type ground heat exchanger (GHX) have developed to overcome disadvantages such as high initial cost. However, these performances of GHXs are greatly influenced by climate and weather conditions. It is necessary to analyze the performance of GHX according to the ground temperature change in the installation site. In this study, the ground temperature of each installation site confirmed and performance of unit-type GHX quantitatively analyzed by numerical analysis. As the result, the performance of the unit type GHX was 33.9 W/m in Seoul, 34.2 W/m in Daejeon, and 37.2 W/m in Busan.The result showed the difference performance of GHX according to local climate was maximum of 9.7%.

에너지플러스 시뮬레이션을 통한 하천수 열원 히트펌프 시스템의 적용 가능성 분석 (An Applicability Analysis of River Water Source Heat Pump System using EnergyPlus Simulation)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권2호
    • /
    • pp.10-21
    • /
    • 2022
  • A water source heat pump (WSHP) system is regarded as an energy-efficiency heating and cooling supply system for buildings due to its high energy efficiency and low greenhouse gas emissions. Recently, water sources such as river water, lake water, and raw water are attracting attention as heat sources for a heat pump system in Korea. This paper analyzed the applicability of a river water source heat pump system (RSHP). The river water temperature level was compared with the outdoor air and ground temperature levels to present applicability. In addition, the cooling and heating performance were compared through a simulation approach for the RSHP and a ground source heat pump (GSHP) applied to a large-scale office building. To compare the temperature level, the actual data were applied to the river water and the outdoor air, while the simulation results were applied to the ground circulation water. The results showed that the change in river water temperature throughout the year was similar to the change in outdoor air temperature. However, unlike the outdoor air temperature, the difference between the hourly and daily average river water temperatures was not large. The temperature level of river water was lower during the heating season and somewhat higher during the cooling season than that of the ground circulation water. Finally, the performance of the RSHP system was 13.4% lower than that of the GSHP system on an annual-based.