• 제목/요약/키워드: Ground resistance

검색결과 1,049건 처리시간 0.025초

배전계통 접지전극의 접지효과 분석 연구 (Comparison the grounding effect of a grounding rods and a grounding copper band in the Distribution System)

  • 강문호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.509-511
    • /
    • 2004
  • Grounding rods as a discharge path are normally used to ensure the safety of human beings and facilities from the over-voltages and the over·current. Each grounding mode class 1, class 2, class 3, special class 4- has prescribed ground resistance values which are kept by the utilities. However, in the distribution system, it is very difficult for grounding rods to obtain the prescribed ground resistance values because of the limits of installation space. Therefore, in this paper, the grounding effects of the grounding copper bands which are recently developed to use efficiently in small area and the grounding rods are compared by testing the ground resistance values, ground potential rise(GPR), and step voltage in various cases.

  • PDF

침하가 예측되는 지반에서 강관말뚝 주면 마찰 저항에 따른 말뚝의 거동 분석 (Analysis of Pile Behaviors with Friction Resistance of Skin of Steel Pipe Pile in Ground where Settlement is Predicted)

  • 이기철;신세희;이학린;김동욱
    • 한국지반공학회논문집
    • /
    • 제36권11호
    • /
    • pp.107-117
    • /
    • 2020
  • 개단 강관말뚝의 경우 일반적으로 말뚝에 작용하는 외부 주면 마찰력뿐만 아니라 설치과정에서 폐색된 흙이 강관 내부에 작용하는 내부 마찰저항이 존재한다. 내·외부 저항에 따라 극한하중의 변화가 예상되며, 말뚝이 시공된 지반이 점성토일 경우 지반 침하로 유발되는 부주면 마찰력에도 영향을 끼칠 것으로 판단된다. 따라서 본 연구에서는 강관말뚝 내·외부 저항 특성에 따른 거동을 수치해석적으로 분석하고자 하며, 지반 침하 발생 전·후의 마찰력 분포, 축력, 침하량을 산정하였다. 해석 결과, 내부 마찰 저항은 외부 마찰 저항보다 적은 영향을 미쳤지만 전체적인 말뚝 거동에 끼치는 영향을 고려하였을 때, 중요한 요소 중 하나이며 설계 시 두 가지 저항요소를 고려할 필요가 있을 것으로 판단된다.

다중방전 경로를 이용한 편상접지체의 접지저항 및 전류특성 (Grounding Resistance and Current Characteristics of the Planar Earth Structure using Multiple Discharge Paths)

  • 김영선;김동민;이기식
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1564-1570
    • /
    • 2016
  • This study proposes a newly modified form of existing ground electrodes in order to secure trust of grounding system for large current caused by a stroke of lightning. Proposed planar earth structure has a several needle electrodes around a circular rod and 4 plane electrodes in all directions. The plane electrodes are fused with the insulator on the linear rod, so that they're electrically isolated. The concept is to increase the discharge amount of earth structure using multiple discharge paths like needle and plane electrodes. To check the discharge efficiency of the suggested scheme, the discharge currents are compared with typically used two kinds of ground rods. To ensure accuracy in the measurement of the discharge current, the same material was used for the comparison model. Also, the ground resistance are simulated by CDEGS commercial software and the results are compared with measured data. Based on this kind of experimental study, the suggested ground rod can be used when designing a ground system or when constructing a ground system at the site.

임펄스전압에 의한 토양의 이온화에 따른 접지성능의 향상 (Improvements of Grounding Performances Associated with Soil Ionization under Impulse Voltages)

  • 김회구;이복희
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.1971-1978
    • /
    • 2016
  • In this paper, electrical and physical characteristics associated with the ionization growth of soil under impulse voltages in a coaxial cylindrical electrode system to simulate a horizontally-buried ground electrode were experimentally investigated. The results were summarized as follows: Transient ground resistances decreased significantly by soil ionization. The voltage-current (V-I) curves for non-ionization in soil lined up in a straight line with the nearly same slope that is the ground resistance, but they showed a 'cross-closed loop' of ${\infty}$-shape under ionization. The conventional ground resistance and equivalent soil resistivity were inversely proportional to the peak value of injected impulse currents. On the other hand, the equivalent ionization radius and time-lag to the maximum value of ionization radius were increased with increasing the incident impulse voltages. An analysis method for the transient ground resistances of the ground electrode based on the ionization phenomena was proposed. The proposed method can be applied to analyze the transient performances of grounding systems for lightning protection in power system installations.

고로슬래그 미분말을 사용한 고유동콘크리트의 내동해성에 관한 실험적 연구 (An Experimental Study on the Frost Resistance of High-Flowing Concrete Using Granulated Blast-Furnace Slag)

  • 김무한;권영진;강석표
    • 콘크리트학회논문집
    • /
    • 제12권2호
    • /
    • pp.43-51
    • /
    • 2000
  • This study is to investigate for the frost resistance of high-flowing concrete using finely ground granulated blast-furnace slag with experimental parameters, such as type of binder, type of superplasticizer and method of curing. The resistance to freezing and thawing of high-flowing concrete by type of binder and superplasticizer is presented differently. Though the frost resistance of high-flowing concrete is satisfactory under standard condition, it is required that high-flowing concrete has entrained air like plain concrete. Because the critical spacing factor, being capacity of frost resistance, of high-flowing concrete is longer that of plain concrete, the frost resistance of high-flowing concrete, using finely ground granulated furnace blast slag, is superior to that of plain concrete.

지중열교환기 설치 조건이 지중 유효 열전도도에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effect of Ground Heat Exchanger to the Overall Thermal Conductivity)

  • 공형진;임효재;최재호;손병후
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.45-51
    • /
    • 2009
  • A ground-loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. The size and performance of this heat exchanger is highly dependent on ground thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U-tube configurations on ground effective thermal conductivity. In this study, thermal response tests were conducted using a testing device with 9-different ground-loop heat exchangers. From the experimental results, the length of ground-loop heat exchanger affects to the effective thermal conductivity. Among the various grouting materials, the bentonite-based grout with silica sand shows the largest thermal conductivity value.

  • PDF

다짐말뚝 채움재로서 슬래그의 적용성 연구 (A Study on the Applicability of Slag as Compaction Pile Material)

  • 이미혜;이상익;박용원
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.207-214
    • /
    • 2000
  • Sand Compaction Pile method is one of the widely used ground improvement techniques at loose sand or soft clay ground in Asian countries. However, due to environmental and economical problems concerning shortage of sand resources alternative materials are needed to substitute sand for SCP. This study is on the applicability of slag as an alternative material SCP. Consolidation and direct shear test are performed for the slag-clay composite specimens to find out the positive effects of consolidation rate and shear resistance of slag reinforced ground. The result shows that slag has similar effects with sand in consolidation and shear resistance behavior in composite ground, which says slag can be used as alternative material of sand for SCP.

  • PDF

PHC 에너지 파일을 이용한 지반의 열전도도 산정 (Thermal Conductivity Estimate of Ground Using Energy Piles)

  • 윤석;고규현;박현구;박스칸;이승래;조경진;송치용
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권4호
    • /
    • pp.8-16
    • /
    • 2012
  • The use of energy pile foundation has been increased for economic utilization of geothermal energy. This paper describes an experimental and numerical study on thermal response tests (TRTs) using W and 3U-shaped ground heat exchangers (GHEs) in precast-high strength concrete (PHC) energy piles. Ground thermal conductivity and borehole thermal resistance were measured and compared with those numerical analysis. W-shpaed GHE showed higher heat transfer behavior than 3U-shaped one because of different conditions such as pile size and volume of grout. That is, ground thermal conductivity using W-shaped GHE was higher than that of 3U shaped GHE, and borehole thermal resistance vice versa. The relative error of borehole resistance values between numerical and analytical solution was less than 5%.

광대역 접지임피던스 측정기의 설계 및 제작 (Design and Fabrication of a Wideband Ground Impedance Meter)

  • 길경석;박대원;장운용;한주섭;길형준
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.793-797
    • /
    • 2010
  • The basic performance of the ground system is evaluated as the ground resistance by applying low frequency current below 1 kHz. However, characteristics of the ground system should be analyzed by high frequency current up to 1 MHz since transient currents having a few hundred kHz component flow during a line-to-ground fault and/or a lightning strike. This paper deals with the design and fabrication of a wideband ground impedance meter (WGIM) which measures the impedance of ground systems in ranges from 65 Hz to 1.28 MHz. Also, a noise elimination algorithm using a digital bandpass filter is proposed. The maximum error of the WGIM is 4.91% in the measurement frequency range.

아두이노 기반 IT융합 스마트 대지저항 측정 기술 연구 (A Study on Smart Ground Resistance Measurement Technology Based on Aduino)

  • 김홍용
    • 한국재난정보학회 논문집
    • /
    • 제17권4호
    • /
    • pp.684-693
    • /
    • 2021
  • 연구목적: 아두이노를 이용하여 실시간 대지저항 데이터를 취득할 수 있는 스마트 대지저항 측정장치를 개발하여 낙뢰 등 이상전압으로부터 안전한 설비환경을 구축하는것에 목적이 있다. 연구방법: 본 논문은 아두이노와 전력선 통신(PLC) 체계를 갖춘 대지저항 취득 및 분석 시스템을 개발하여 설계모델과 적용사례를 연구하였다. 경남지역의 풍력발전 단지 내 일부 부지를 테스트 베드로 선정하여 신기술을 적용한 실시간 대지저항 데이터를 취득하였다. 전극배열은 웨너(Wenner) 4전극배열과 슐렘버거(Schlumberger) 전극배열을 혼용한 스마트 전극배열을 채택하였다. 연구결과: 본 기술의 특징은 첫 번째로 스마트 다 전극의 깊이를 각기 다르게 편성해 층간에 특이성을 가지는 지층 구조에도 취득 데이터의 오차범위를 축소하였다. 두 번째로 스마트 접지전극에서 취득한 대지저항 데이터의 정보를 사물인터넷으로 실시간 송·수신이 가능하도록 IT융합 기술을 적용하였다. 마지막으로 규칙적인 관리 체계를 구축하고 Server에 축적된 빅 데이터를 분석하여 다양한 요소들의 변화추이를 확인할 수 있으며, IT융합 환경에 최적의 접지 알고리즘과 접지시스템 설계 모델링이 가능하다. 결론: 본 기술은 4차 산업 시대에 근간이 되는 도시 기반시설에 낙뢰로 인한 서지(Surge)의 피해를 줄이고 최적화된 접지시스템 모델을 설계하여 사용자의 안전과 생명을 보호 할 것이다. 또한 순수 국산 기술력의 지적재산권을 확보하여 포스트 코로나 시대에 팬데믹으로 정체되어있는 우리산업의 일자리 창출과 활기를 불어넣는 효과도 기대된다.