3상4선식 계통에서 중성선 영상고조파 저감에 따른 기대효과 (The expectation effects of a decrease in neutral wires Zero Sequence harmonic currents in 3 phases - 4 wires systems)

  • 강창원;이성우;정연해;김세동;이원구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.715-719
    • /
    • 2002
  • Recently, Dangers due to harmonics emanated from all sorts of machinery have been on the increase with the development in industry. One of them is that Zero Sequence harmonic currents flow from the neutral wires in 3 phases - 4 wire systems. The flowing of harmonic currents in neutral wires brings about the superheating and falloff in output of transformer, the overheating of them, a rise in ground potential and the wrong movement of machinery, so has a bad influence on this system. To develop the machinery to decrease neutral wires Zero sequence harmonic currents and apply it help solve these problems and bring about the effects of a improvement in power factor and energy savings.

  • PDF

건물의 직격뢰시 본딩 방식에 따른 서지 진압 분포 (Surge Voltage Distribution at the Different Bonding Practice During a Direct Lightning Stroke to Building)

  • 이재복;장석훈;명성호;조연규
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.444-450
    • /
    • 2008
  • There are several ways to bond to building grounding systems for reducing GPR(ground potential rise) and EMI resulting from power system faults or lightning stroke to building. In order to verify effective bonding practice, the GPR and voltage of equipment due to the direct stroke to building are calculated with ATP-EMTP model for transformer, transmission line and MOV(Metal oxide varistor). The simulated model shows a satisfactory accuracy compared with experimental result for the $8/20{\mu}s$ simulated current pulse. It is observed that separate grounding can cause dangerous voltage to the building equipment and the performance of surge protective device can improve when it is installed to the protected equipment in distance as short as possible.

무부하 충전케이블 개방시 잔류전압에의한 과전압계전기 동작현상 연구 (A Study of Over Voltage Ground Relay Operation Status at Opening of No-load Charged Cable)

  • 김영한;최종혁;윤기섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.185-187
    • /
    • 2000
  • Fault current is flowed into 154/23kV M. Tr when line-to-ground fault occurs in power system. NGR(Neutral Grounded Reactor) is set up in order to prevent M.Tr fault by limiting magnitude of fault currents. Here, disconnection of NGR causes voltage increase by L-C resonance and line-to-ground fault in an unearthed system results in voltage increase at healthy phases. So Over Voltage Ground Relay(OVGR) is used for tripping M.Tr. Also, buses at second phases of M.Trs are all connected with section circuit breakers closed for the purpose of parallel operation and load shedding. In case of speciality buses are comprised of power cable in part for GIS connection. When no-load charged cable or bus is open by a section CB, unbalanced voltage charged on the bus is induced. Also discrepant opening time for circuit breakers on different phases gives rise to unbalanced zero sequence voltage. It was observed that this zero sequence voltage detected in the 22.9kV P.T (Potential Transformer for bus) mal-operated 59GT and tripped M.Tr. The zero sequence voltage of which vanishing time is longer than relay operating time came out by EMTDC simulation. Also, it was shown that the voltage waves of actual test are similar to those of simulation. On the basis of above results, R-C circuit complement on the relay without any effect on a power system made operating time of the relay longer than vanishing time of distorted waves. Consequently, operating time of the relay was delayed and magnitude of distorted waves was decreased by increasing time constant of the relay.

  • PDF

High-rate Single-Frequency Precise Point Positioning (SF-PPP) in the detection of structural displacements and ground motions

  • Mert Bezcioglu;Cemal Ozer Yigit;Ahmet Anil Dindar;Ahmed El-Mowafy;Kan Wang
    • Structural Engineering and Mechanics
    • /
    • 제89권6호
    • /
    • pp.589-599
    • /
    • 2024
  • This study presents the usability of the high-rate single-frequency Precise Point Positioning (SF-PPP) technique based on 20 Hz Global Positioning Systems (GPS)-only observations in detecting dynamic motions. SF-PPP solutions were obtained from post-mission and real-time GNSS corrections. These include the International GNSS Service (IGS)-Final, IGS real-time (RT), real-time MADOCA (Multi-GNSS Advanced Demonstration tool for Orbit and Clock Analysis), and real-time products from the Australian/New Zealand satellite-based augmentation systems (SBAS, known as SouthPAN). SF-PPP results were compared with LVDT (Linear Variable Differential Transformer) sensor and single-frequency relative positioning (SF-RP) solutions. The findings show that the SF-PPP technique successfully detects the harmonic motions, and the real-time products-based PPP solutions were as accurate as the final post-mission products. In the frequency domain, all GNSS-based methods evaluated in this contribution correctly detect the dominant frequency of short-term harmonic oscillations, while the differences in the amplitude values corresponding to the peak frequency do not exceed 1.1 mm. However, evaluations in the time domain show that SF-PPP needs high-pass filtering to detect accurate displacement since SF-PPP solutions include trends and low-frequency fluctuations, mainly due to atmospheric effects. Findings obtained in the time domain indicate that final, real-time, and MADOCA-based PPP results capture short-term dynamic behaviors with an accuracy ranging from 3.4 mm to 8.5 mm, and SBAS-based PPP solutions have several times higher RMSE values compared to other methods. However, after high-pass filtering, the accuracies obtained from PPP methods decreased to a few mm. The outcomes demonstrate the potential of the high-rate SF-PPP method to reliably monitor structural and earthquake-induced ground motions and vibration frequencies of structures.

비접지 배전계통 지락고장 검출 알고리즘 및 프로그램 개발 (Development of Algorithm and Program for the Ground Fault Detection in Ungrounded Distribution Power System)

  • 박소영;신창훈
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2619-2627
    • /
    • 2009
  • 비접지 배전계통에서 전체고장의 약 70%를 차지하는 지락고장 발생시에는 지락전류가 작아 검출이 어렵지만 고장상태로 전원 공급을 지속할 경우 사고 파급 및 기기 소손을 유발할 가능성이 있기 때문에 지락고장 처리는 매우 중요하다. 본 논문에서는 GPT(접지형 계기용 변압기, Ground Potential Transformer)에서 감지하는 영상전압 신호를 이용하여 고장선로를 검출하고, 비상시 연계선로를 이용하여 정전구역을 복구하기 위해 평상시 개폐기가 열려 있는 상태로 배전선로 사이를 연결하는 상시개방점을 이동하며 각 구간을 차례로 분리하면서 GPT 신호의 사라짐 여부를 감시하여 고장구간을 검출하는 방법을 제안한다. 고장구간 탐색 시 전체 정전이 없고, 고장구간 검출과 건전구간 복구가 동시에 가능하며 다양한 형태의 배전계통 구성에 적용 가능하다는 점에서 효율적이다. 본 논문에서 제안하는 고장처리 방법을 프로그램으로 개발하여 베트남 배전자동화 시범사업에 적용함으로써 알고리즘 및 프로그램의 적정성을 검증하였다.

열차운행 안정화를 위한 주회로 기기의 고조파 제한장치 개발에 관한 연구 (A Study on the Development of Harmonic Limit Device for Stabilizing Main Circuit Equipment of Train)

  • 김성준;채은경;강정원
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제8권6호
    • /
    • pp.853-861
    • /
    • 2018
  • 본 논문에서는 전기철도차량이 운행할 때 이상 전압상승에 의한 문제점을 해결할 수 있는 고조파 제한장치의 적용을 제안한다. 운행 중 열차에 전력을 공급하는 교류가선은 25kV/60Hz의 전기를 공급하기 위하여 사용되지만 철도차량 전기장치의 기술발전에 따라 점차 가선에 포함되는 고조파의 크기 및 주파수의 변형이 다양해지고 있다. 최근 열차안전운행에 심각한 문제가 되고 있는 주회로 기기인계기용변압기(Potential Transformer, PT)의 파손이나 주변압기 등의 열손증가는 가선 전원의 고조파로 인한 순간적인 무효전류의 증가로 생기는 현상이다. 주회로 기기의 저주파형 트랜스포머로 고주파수 성분이 유입되면 트랜스 코어의 히스테리시스에 의한 철손 증가 및 기생 커패시턴스에 흐르는 전류가 증가하므로 발열이 발생하게 된다. 이러한 문제 해결을 위해 최근 시퀀스의 조정으로 전력변환 장치의 인위적인 NOTCH OFF가 적용되었다. 그러나, OFF 신호를 받아 제어하는 방식은 지상과 차상 장치의 상호작용으로 동작하므로 불량 발생 시 무효화 되며, 실제 사고가 발생되고 있다. 따라서, 근본적인 문제해결을 위한 방법으로 고조파 전류가 가급적 변압기에 유입되지 않도록 하는 것이 필요하며, 고조파 전류의 유입으로 인해 빈번하게 발생되고 있는 열차사고를 방지하고 안전한 운행을 위해 열차의 실험 분석과 고조파 제한장치의 시뮬레이션을 통한 장치의 타당성 검증을 위한 연구를 수행하였다.

고조파발생에 따른 영향과 대책 연구 (Effect of Harmonic Generation and Countermeasures)

  • 백동현
    • 한국화재소방학회논문지
    • /
    • 제29권6호
    • /
    • pp.91-97
    • /
    • 2015
  • 초고층건축물이나 대형 사업장과 IT를 추구하는 수용가는 많은 가전기기 사용하여 선형, 비선형부하시의 고조파로인한 Capacitor의 과열 및 소손, 자료 손상, 대지전위 상승, 통신유도장해등을 일으켜 전력설비의 오동작과 과열로 화재의 원인이 될 수 있다. 이를 확인하기 위해 건축물의 7곳을 조사하여 비교한 결과 6곳에서는 적정하였으나 1곳은 고조파관리가 필요하였다. 전류 고조파는 No. 3, 6, 7은 매우 초과하여 정밀 진단이 필요하였으며 No. 2, 3, 5는 5고조파 전류를 고려하여야 한다. R상 전압고조파는 양호하였으나 전류고조파는 No. 1을 제외하고 No. 2, 3, 4, 5, 6, 7은 모두 기준을 초과하였다. 따라서 지그재그변압기나 엑티브필터를 설치하여 고조파 상승을 억제시킬 필요가 있고 설비불평형률, 역률등을 종합 조사하여 효율도 향상시킬 필요가 있다.