• Title/Summary/Keyword: Ground layer

Search Result 1,152, Processing Time 0.038 seconds

Manufacturing Technique of the Avalokitesvara Bodhisattva Mural Painting in Geungnakjeon Hall, Daewonsa Temple, Boseong

  • Yu, Yeong Gyeong;Jee, Bong Goo;Oh, Ran Young;Lee, Hwa Soo
    • Journal of Conservation Science
    • /
    • v.38 no.4
    • /
    • pp.334-346
    • /
    • 2022
  • The manufacturing technique was studied through the structure and material characteristics of the walls and the painting layers of the Avalokitesvara Bodhisattva mural of Geungnakjeon Hall, Daewonsa Temple. The mural is painted and connected to the earthen wall and the Junggit, and the wall is composed of wooden laths as a frame, the first and middle layers, the finishing layer, and the painting layer. The first layer, middle layer, and finishing layer constituting the wall were made by mixing weathered soil and sand. It was confirmed that the first layer had a high content of loess below silt, and the finishing layer had a high content of fine-sand and very fine sand. For the painting layer, a ground layer was prepared using soil-based mineral pigments, and lead white, white clay, atacamite, minium, and cinnabar (or vermilion) pigments were used on top of it. The Avalokitesvara Bodhisattva mural was confirmed to belong to a category similar to the soil-made buddhist mural paintings of Joseon Dynasty. However, it shows characteristics such as a high content of fine sand in the finishing layer and overlapping over other colors. Such material and structural characteristics can constitute important information for future mural conservation status diagnoses and conservation treatment plans.

Field and laboratory assessment of ground subsidence induced by underground cavity under the sewer pipe

  • Kong, Suk-Min;Kim, Dong-Min;Lee, Dae-Young;Jung, Hyuk-Sang;Lee, Yong-Joo
    • Geomechanics and Engineering
    • /
    • v.16 no.3
    • /
    • pp.285-293
    • /
    • 2018
  • In densely populated urban areas with a large amount of infrastructure, ground subsidence events can result in massive casualties and economic losses. In South Korea, the incidence of ground subsidence in urban areas has increased in recent years and the number of underground cavities suspected of causing such events has significantly increased. Therefore, it is essential to develop techniques to prevent the occurrence of underground and ground subsidence. In this study, a field test, laboratory test, and numerical analysis were conducted to determine the optimal compaction degree of the upper support layer of any underground cavity below the level of sewer pipes in order to prevent such cavities from collapsing and leading to ground subsidence accidents. During the field test, an underground cavity was simulated using ice, and the generation of the cavity was confirmed using ground penetrating radar. The ground investigation was performed using a cone penetration test, and the compaction of the ground where ground subsidence occurred was evaluated with a laboratory test. The behaviour of the ground under various conditions was predicted using a numerical analysis based on the data obtained from the field test and previous studies. Based on these results, the optimal compaction degree of the ground required to prevent the underground cavity from causing ground subsidence was predicted and presented.

Ground Motion Simulation of Scenario Earthquakes in the Nakdonggang Delta Region using a Broadband Hybrid Method and Site Response Analysis (광대역 하이브리드 기법과 지반응답 해석을 통한 낙동강 삼각주 지역의 가상지진 지반운동 시뮬레이션)

  • Kim, Jaehwi;Oh, Junsu;Jeong, Seokho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.5
    • /
    • pp.233-247
    • /
    • 2024
  • The damage to structures during an earthquake can be varied depending on the frequency characteristics of seismic waves and the geological properties of the ground. Therefore, considering such attributes in the design ground motions is crucial. The Korean seismic design standard (KDS 17 10 00) provides design response spectra for various ground classifications. If required for time-domain analysis, ground motion time series can be either selected and adjusted from motions recorded at rock sites in intraplate regions or artificially synthesized. Ground motion time series at soil sites should be obtained from site response analysis. However, in practice, selecting suitable ground motion records is challenging due to the overall lack of large earthquakes in intraplate regions, and artificially synthesized time series often leads to unrealistic responses of structures. As an alternative approach, this study provides a case study of generating ground motion time series based on the hybrid broadband ground motion simulation of selected scenario earthquakes at sites in the Nakdonggang delta region. This research is significant as it provides a novel method for generating ground motion time series that can be used in seismic design and response analysis. For large-magnitude earthquake scenarios close to the epicenter, the simulated response spectra surpassed the 1000-year design response spectra in some specific frequency ranges. Subsequently, the acceleration time series at each location were used as input motions to perform nonlinear 1D site response analysis through the PySeismoSoil Package to account for the site response characteristics at each location. The results of the study revealed a tendency to amplify ground motion in the mid to long-period range in most places within the study area. Additionally, significant amplification in the short-period range was observed in some locations characterized by a thin soil layer and relatively high shear wave velocity soil near the upper bedrock.

Ground Fault Current Variation of 22.9kV Multi Neutral Grounded Distribution System with CD Type Superconducting Cable (22.9kV 중성점 다중접지계통에 CD형 초전도케이블을 적용한 경우의 지락전류변화)

  • Lee, Jong-Bae;Hwang, Si-Dole;Sohn, Song-Ho;Lee, Geun-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.993-999
    • /
    • 2007
  • This paper discusses the effects of CD type superconducting cable operation in 22.9kV multi neutral grounded distribution system during L-G fault and counterplans to power system protection. In case of using the 3-phase CD-type superconducting cable, the inductance of superconducting cable system would be decreased due to the current of shield part of superconducting cable, which is opposite direction and nearly equal value with respect to main superconductor. However, when the shield circuit system is operated in shorted state, shield current decreases faulted ground current and give effects to power system protection scheme. This study examines the phenomena of single line to ground fault case in above mentioned system using the EMTDC program and discusses the right operation method of superconducting shield.

Dynamic analysis Ground using 2-D FEM (차량하중에 의한 주변지반의 진동해석)

  • 황성춘;강보순;심형섭;오병헌;박성진
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.642-647
    • /
    • 2001
  • Dynamic response of ground due to train loads is analyzed. A numerical procedure based on finite element method is used to solve two-dimensional ground response. Dynamic train loads assumed in analysis is the point acceleration on train rail with magnitude of 2330 gal and thickness of surface of soil layer assumed is 60cm. In order to consider the effect of acceleration point, dynamic responses such as response acceleration and displacement are computed as a function of distance from acceleration point on rail. In addition, simple methods which reduce dynamic effects on ground are also proposed.

  • PDF

Noncontact techniques for monitoring of tunnel linings

  • White, Joshua;Hurlebaus, Stefan;Shokouhi, Parisa;Wittwer, Andreas;Wimsatt, Andrew
    • Structural Monitoring and Maintenance
    • /
    • v.1 no.2
    • /
    • pp.197-211
    • /
    • 2014
  • An investigation of tunnel linings is performed at two tunnels in the US using complimentary noncontact techniques: air-coupled ground penetrating radar (GPR), and a vehicle-mounted scanning system (SPACETEC) that combines laser, visual, and infrared thermography scanning methods. This paper shows that a combination of such techniques can maximize inspection coverage in a comprehensive and efficient manner. Since ground-truth is typically not available in public tunnel field evaluations, the noncontact techniques used are compared with two reliable in-depth contact nondestructive testing methods: ground-coupled GPR and ultrasonic tomography. The noncontact techniques are used to identify and locate the reinforcement mesh, structural steel ribs, internal layer interfaces, shallow delamination, and tile debonding. It is shown that this combination of methods can be used synergistically to provide tunnel owners with a comprehensive and efficient approach for monitoring tunnel lining conditions.

Characteristics of Groundwater Contamination in Uncontrolled Landfill and Pollution Control Measures (불량 매립지에서의 지하수 오염특성과 환경오염 방지방안)

  • 구자중;윤석표
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1993.05a
    • /
    • pp.28-44
    • /
    • 1993
  • Remediation actions in uncontrolled landfill site should be conducted after the investigation of contamination status and potential health risk or damage. Based on the above, proper control measures should be established and operated. Also continuous monitoring should be followed. In this study, the status of ground water contamination around Nanji Landfill Site was investigated. Monitoring wells were installed around the landfill and ground water was sampled once a month and analyzed. Water quality of each monitoring well was different depending on the horizontal and vertical distance from the landfill, and the seasonal leachate characteristics were not significantly changed because percolating water stayed long time in the deep waste layer. It was predicted that major multivalent cations were mainly precipitated as metal carbonate form, and chemical mass balances (CMBs) could be applied for the apportionment of leachate contamination to ground water quality of surrounding areas of Nanji Landfill. Parameters required to estimate pollutant flux to the receptor near landfill were listed and discussion to get these parameters was made. Finally, based on the above data, control measures of ground water contamination were suggested and discussed.

  • PDF

A Study on the Lateral Flow of the Silts which is Polluted with a Garbage Leachate to the Dyes (쓰레기 침출수와 염료로 오염된 실트지반의 측방유동에 관한 연구)

  • Ahn, Jong-Pil;Park, Sang-Bum;Ahn, Ki-Mun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1157-1166
    • /
    • 2008
  • Critical surcharge value of silt ground polluted with garbage leachate to the dyes $q_{cr}=3.73c_u$ and ultimate bearing capacity value $q_{ult}=8.60c_u$. Lateral flow pressure at polluted silt ground was about $P_{max}$/3 and depth of maximum lateral flow pressure was found at that of H/3 of soft layer thickness(H). Expression of polluted silt ground of fracture baseline at stability control charge by Matsuo Kawamura is $S_v=3.56\exp\{0.51(Y_m/S_v)\}$.

  • PDF

Study on Physical Characteristics of Historical and Artificial Ground Accelration (역사지진 및 인공지진의 물리적특성에 관한 연구)

  • 전환석
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.52-57
    • /
    • 1998
  • Becaruse of the continual occurrence of minor and moderate earthquake in Korean peninsula, it is generally considered that Korean is nor located in safe region against probable earthquake and more, even though being recognized as a safe contry in earthquake. It is in particular noted that nowadays there has been much concern about undesirable disaster due to unexpected earthquake since the disaster of 1995 Kobe earthquake. Thus, the objective of this research is to develop appropriate design spectrum which could be practicably used in seismic design of important structures taking into consideration of local physical characteristics. Particularly, we have to keep in mind the lessons from 1985 Mexico earthquake which had disregarded deep research on local ground conditions, being a possible magnification phenomena of ground motions in weak soil layer. Various spectra has been described based on the analysis of historical earthquakes, and appropriate design spectrum has been proposed herein.

  • PDF

Model Test on the Effect of the Depth of Revetment by Inter Sand Layer in Soft Ground (모형토조 실험을 이용한 연약지반내 중간모래층이 호안제방하부 강제치환 깊이에 미치는 영향 연구)

  • Chung, Hyung-Sik;Bang, Chang-Kuk;Lee, Yong-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.956-965
    • /
    • 2005
  • In this paper, the effect on the forced replacement depth of the revetment in soft soil with inter sand layer is analyzed by model test. In the result, the forced replacement occur in 60 second from filling the embankment material. The shape of the forced replacement depth is like to punching shape. Then, in case of thin inter sand layer and near the embankment, the forced replacement depth of inter sand layer case is more than only clayed soil case.

  • PDF