• Title/Summary/Keyword: Ground layer

Search Result 1,152, Processing Time 0.029 seconds

A Study on the Ground Covering in Landscape Planting -In the Case of the Mongchon Earth Fort- (조경배식에 있어 지피식생조성에 관한 연구 -몽촌토성을 중심으로-)

  • 우종서;이경재
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.18 no.4
    • /
    • pp.7-16
    • /
    • 1991
  • This research investigated soil, plants, insects and birds in the Mongchon Earth Fort, establishing the 11 plots, according to planting treatment, in order to present management method for ecological stability of species in the ground covering plots. The results of analysizing the investigated data summarize as follows. 1. In the ground covering plots without upper layer, the density and coverage of middle and low layer in the natural plots were higher than those in the artificial plots. 2. In the ground covering plots without upper layer, the density and coverage of low layer were higher than those in the artificial, while the density and coverage of herb layer in the natural plots were lower. 3. Whether there was upper layer or not, the total species diversity and enenness of the ground covering community in the natural plot without artificial treatment and natural treatment plot were higher than those ground covering. 4. In the ground covering plots with upper layer, the species diversity of ground covering in the plots without artificial treatment is high, while the species diversity in the plots with natural treatment caused the secondary succession is higher than that of the natural plot. 5. In the ground covering plots without upper layer, the species diversity in the plots with artificial management was higher than that of natural plots, while the evenness in the plots with artificial management was lower. 6. In the ground covering plots with upper layer the species diversity of insect in the plot of natural state was higher than that of insect in the plots with artifical treatment. 7. Synthetically, in the area with upper layer the species diversity of the ground covering community in the natural plot was high, while in the area without upper layer, the species diversity of it in the plots with artificial treatment was high. The insect turned up frequently in the plots of high species diversity of the ground covering, so the bird did in the plots of high species diversity of the ground covering and insects.

  • PDF

Seismic performance of the immersed tunnel under offshore and onshore ground motions

  • Bowei Wang;Guquan Song;Rui Zhang;Baokui Chen
    • Earthquakes and Structures
    • /
    • v.27 no.1
    • /
    • pp.41-55
    • /
    • 2024
  • There are obvious differences between the characteristics of offshore ground motion and onshore ground motion in current studies, and factors such as water layer and site conditions have great influence on the characteristics of offshore ground motion. In addition, unlike seismic response analysis of offshore superstructures such as sea-crossing bridges, tunnels are affected by offshore soil constraints, so it is necessary to consider the dynamic interaction between structure and offshore soil layer. Therefore, a seismic response analysis model considering the seawater, soil layer and tunnel structure coupling is established. Firstly, the measured offshore and different soil layers onshore ground records are input respectively, and the difference of seismic response under different types of ground motions is analyzed. Then, the models of different site conditions were input into the measured onshore bedrock strong ground motion records to study the influence of seawater layer and silt soft soil layer on the seabed and tunnel structure. The results show that the overall seismic response between the seabed and the tunnel structure is more significant when the offshore ground motion is input. The seawater layer can suppression the vertical seismic response of seabed and tunnel structure, while the slit soft soil layer can amplify the horizontal seismic response. The results will help to promote seismic wave selection of marine structures and provide reference for improving the accuracy of seismic design of immersed tunnels.

Application of Ground Penetrating Radar for Estimation of Loose Layer (지반 이완구간 추정을 위한 지하투과레이더의 적용)

  • Hong, Won-Taek;Kang, Seonghun;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.11
    • /
    • pp.41-48
    • /
    • 2015
  • An investigation of a void and a loose layer of the ground is essential in order to prevent the losses of life and properties caused by subsidence and sinkage of the ground. Recently, studies on the ground penetrating radar survey have been actively conducted in order to estimate the void and the loose layer of the ground. However, an error can be committed by contrarily predicting a dense ground and a loose layer because the ground penetrating radar estimates an interface depth between geo-materials that have different electrical impedances. In this study, a loose ground depth is estimated using the characteristics of the reflected electromagnetic wave obtained from the ground penetrating radar survey. To gather the signals according to the loose ground depths, the ground penetrating radar survey is conducted on a field which underwent a huge ground settlement. In addition, the dynamic cone penetration test is performed to verify the result of the loose ground depth estimation from the ground penetrating radar survey. From the analysis of the reflection characteristics of the electromagnetic wave, a phase of an electromagnetic wave reflected from a denser soil layer is found to be identical with that of the first measured signal. On the other hand, a phase of an electromagnetic wave reflected from the loose soil layer is found to be opposed to that of the first detected signal. The comparison between the dynamic cone penetration index and electromagnetic signals by the ground penetrating radar shows that the estimated depth of the loose or dense layer is perfectly matched with a high reliability. The ground penetrating radar survey and the signal analysis performed in this study can be used not only for the survey of interface depth between the discontinuity layers but also for the estimation of the loose layer.

Comparison of Ground Movements in A Single Ground Layer and Multiple Ground Layers due to Nearby Tunnel Excavation (터널굴착으로 발생한 주변 단일지층 및 복합지층 지반에서의 지반변위에 대한 거동비교)

  • Son, Moorak;Yun, Jongcheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3C
    • /
    • pp.167-174
    • /
    • 2010
  • In this study, numerical analysis has been performed to compare the ground movements in a single ground layer and multiple ground layers due to nearby tunnel excavation. The numerical analysis has been conducted in the different ground layer conditions considering different construction conditions (volume loss at excavation face), and the results of the maximum surface settlement and horizontal displacement have been compared considering the ground layer and construction conditions. In addition, the maximum surface settlement from the numerical analysis has been compared with the maximum settlement at tunnel crown considering the ground layer and construction conditions, and the maximum surface settlement has been also compared with the maximum horizontal displacement with the ground layer conditions. Besides, the volume loss($V_L$) at tunnel excavation face has been compared with the total surface settlement volume($V_s$) with the variation of ground layer condition. The results from the numerical analysis have been compared with field measurements and by this comparison it is believed that the numerical results in this study can be utilized practically in analyzing the nearby ground behavior in different ground layer and construction conditions due to tunnel excavation.

Ground Penetrating Radar Imaging of a Circular Patterned Ground near King Sejong Station, Antarctica

  • Kim, Kwansoo;Ju, Hyeontae;Lee, Joohan;Chung, Changhyun;Kim, Hyoungkwon;Lee, Sunjoong;Kim, Jisoo
    • The Journal of Engineering Geology
    • /
    • v.31 no.3
    • /
    • pp.257-267
    • /
    • 2021
  • Constraints on the structure and composition of the active layer are important for understanding permafrost evolution. Soil convection owing to repeated moisture-induced freeze-thaw cycles within the active layer promotes the formation of self-organized patterned ground. Here we present the results of ground penetrating radar (GPR) surveys across a selected sorted circle near King Sejong Station, Antarctica, to better delineate the active layer and its relation to the observed patterned ground structure. We acquire GPR data in both bistatic mode (common mid-points) for precise velocity constraints and monostatic mode (common-offset) for subsurface imaging. Reflections are derived from the active layer-permafrost boundary, organic layer-weathered soil boundary within the active layer, and frozen rock-fracture-filled ice boundary within the permafrost. The base of the imaged sorted circle possesses a convex-down shape in the central silty zone, which is typical for the pattern associated with convection-like soil motion within the active layer. The boundary between the central fine-silty domain and coarse-grained stone border is effectively identified in a radar amplitude contour at the assumed active layer depth, and is further examined in the frequency spectra of the near- and far-offset traces. The far-offset traces and the traces from the lower frequency components dominant on the far-offset traces would be associated with rapid absorption of higher frequency radiowave due to the voids in gravel-rich zone. The presented correlation strategies for analyzing very shallow, thin-layered GPR reflection data can potentially be applied to the various types of patterned ground, particularly for acquiring time-lapse imaging, when electric resistivity tomography is incorporated into the analysis.

Key technologies research on the response of a double-story isolated structure subjected to long-period earthquake motion

  • Liang Gao;Dewen Liu;Yuan Zhang;Yanping Zheng;Jingran Xu;Zhiang Li;Min Lei
    • Earthquakes and Structures
    • /
    • v.26 no.1
    • /
    • pp.17-30
    • /
    • 2024
  • Earthquakes can lead to substantial damage to buildings, with long-period ground motion being particularly destructive. The design of high-performance building structures has become a prominent focus of research. The double-story isolated structure is a novel type of isolated structure developed from base isolated structure. To delve deeper into the building performance of double-story isolated structures, the double-story isolated structure was constructed with the upper isolated layer located in different layers, alongside a base isolated structure for comparative analysis. Nonlinear elastoplastic analyses were conducted on these structures using different ground motion inputs, including ordinary ground motion, near-field impulsive ground motion, and far-field harmonic ground motion. The results demonstrate that the double-story isolated structure can extend the structural period further than the base isolated structure under three types of ground motions. The double-story isolated structure exhibits lower base shear, inter-story displacement, base isolated layer displacement, story shear, and maximum acceleration of the top layer, compared to the base isolated structure. In addition, the double-story isolated structure generates fewer plastic hinges in the frame, causes less damage to the core tube, and experiences smaller overturning moments, demonstrating excellent resistance to overturning and a shock-absorbing effect. As the upper isolated layer is positioned higher, the compressive stress on the isolated bearings of the upper isolated layer in the double-story isolated structure gradually decreases. Moreover, the compressive stress on the isolated bearings of the base isolated layer is lower compared to that of the base isolated structure. However, the shock-absorbing capacity of the double-story isolated structure is significantly increased when the upper isolated layer is located in the middle and lower section. Notably, in regions exposed to long-period ground motion, a double-story isolated structure can experience greater seismic response and reduced shock-absorbing capacity, which may be detrimental to the structure.

The dynamic response and seismic damage of single-layer reticulated shells subjected to near-fault ground motions

  • Zhang, Ming;Parke, Gerry;Chang, Zhiwang
    • Earthquakes and Structures
    • /
    • v.14 no.5
    • /
    • pp.399-409
    • /
    • 2018
  • The dynamic response and seismic damage of single-layer reticulated shells in the near field of a rupturing fault can be different from those in the far field due to the different characteristics in the ground motions. To investigate the effect, the dynamic response and seismic damage of this spatial structures subjected to two different ground motions were numerically studied by nonlinear dynamic response analysis. Firstly, twelve seismic waves with an apparent velocity pulse, including horizontal and vertical seismic waves, were selected to represent the near-fault ground motion characteristics. In contrast, twelve seismic records recorded at the same site from other or same events where the epicenter was far away from the site were employed as the far-fault ground motions. Secondly, the parametric modeling process of Kiewitt single-layer reticulated domes using the finite-element package ANSYS was described carefully. Thirdly, a nonlinear time-history response analysis was carried out for typical domes subjected to different earthquakes, followed by analyzing the dynamic response and seismic damage of this spatial structures under two different ground motions based on the maximum nodal displacements and Park-Ang index as well as dissipated energy. The results showed that this spatial structures in the near field of a rupturing fault exhibit a larger dynamic response and seismic damage than those obtained from far-fault ground motions. In addition, the results also showed that the frequency overlap between structures and ground motions has a significant influence on the dynamic response of the single-layer reticulated shells, the duration of the ground motions has little effects.

Earthquake Amplification for Various Multi-Layer Ground Models (다양한 다층 지반모형에 대한 지진동 증폭)

  • Sugeun Jeong;Hoyeon Kim;Daeheyon Kim
    • The Journal of Engineering Geology
    • /
    • v.33 no.2
    • /
    • pp.293-305
    • /
    • 2023
  • Three ground models are analyzed using a 1g shaking table and laminar shear box (LSB) to investigate the impact of the ground structure on seismic wave amplification during earthquakes. Multi-layer horizontal, embankment, and basin ground models are selected for this investigation, with each model being divided into dense and loose ground layers, Accelerometers are installed during the construction of each ground model to capture any seismic wave amplification owing th the propagation of an artificial seismic wave, sine wave sweep, and 10-Hz sine wave through a given ground model. The amplification of the tested seismic waves is analyzed using the observed peak ground acceleration and spectrum acceleration. The observed acceleration amplification in the multi-layer horizontal ground model is significantly higher the seismic waves that propagated across the dense ground-loose ground boundary compared with those that only propagated through the dense ground. Furthermore, the observed acceleration amplification gradually increases in the central part of the multi-layer embankment and basin models for the seismic waves that propagated across the dense ground-loose ground boundary.

Experimental Study on the Reinforcement Effect of Geogrid in Soft Ground Improvement (연약지반 개량시 지오그리드 보강효과에 관한 실험적 연구)

  • Ham, Hyeon-Su;Lee, Sang Duk
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.2
    • /
    • pp.1-7
    • /
    • 2018
  • The number of construction of roads and railroads in soft ground such as coastal areas and wetlands is getting increased. For this reason cases that soft ground improvement is applied are increasing. In general, many ground improvement methods consider only the working conditions at the time or only economy. But if the working condition and economy are taken into consideration together, the number of applicable construction method gets limited. In such a case, a ground improvement method using both the surface layer portion and the deep layer portion is applied. But the basic research on this is still insufficient in practice. Therefore, in this study the reinforcement effect of geogrid was investigated by carrying out the model test realizing the case in which soft surface ground improvement and depth improvement are simultaneously applied. And it was intened to understand the effect of the thickness of surface layer, the diameter and length of the improvement body on the reinforcement effect of geogrid. The result showed that the effect of the surface layer thickness is greater than the effect of the deep layer diameter. Moreover, when the surface layer is reinforced with a geogrid, the strength of the surface layer part is enhanced and this effect of a geogrid reinforcement caused the reduction of surface settlement.

Numerical Analysis of the Vortex Shedding past a Square Cylinder with Moving Ground (지면 운동에 따른 정사각주 후류의 와류 유동장 수치 해석 Part I. 고정 지면과 이동 지면 비교)

  • Kim, Tae-Yoon;Lee, Bo-Sung;Lee, Dong-Ho;Kohama, Y.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.6
    • /
    • pp.1-7
    • /
    • 2005
  • Incompressible Reynolds-averaged Navier-Stokes equations with $\varepsilon{-SST}$ turbulence model are adopted for the investigation of the flow fields between the square cylinder and the ground. When the grounds moves, the diminish of the shear layer intensity on the ground promotes the interaction between the lower and the upper separated shear layer of the cylinder. Hence vortex shedding occurs at the lower gap height than stationary ground. In the moving ground, the secondary shedding frequency disappears due to the absence of the separation bubble on the ground which exists in the stationary ground. In addition, the shedding frequency and aerodynamic coefficients in the moving ground become higher than those of the stationary ground.