• Title/Summary/Keyword: Ground contamination

Search Result 244, Processing Time 0.041 seconds

Estimation of the Optimum Installation Depth of Soil Moisture Sensor in an Automatic Subsurface Drip Irrigation System for Greenhouse Cucumber (시설오이 지중관비시 자동관수센서의 적정 매설깊이)

  • Lim, Tae-Jun;Kim, Ki-In;Park, Jin-Myeon;Noh, Jae-Seung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.2
    • /
    • pp.99-104
    • /
    • 2013
  • Vegetables production in greenhouse are typically intensely managed with high inputs of fertilizers and irrigation water, which increases the risk of ground-water nitrate contamination. In 2010 and 2011, a study was conducted to determine the appropriate depth of soil moisture sensor for automatic irrigation control to use water and nitrogen efficiently under subsurface drip irrigation (SDI) systems. The irrigation line for SDI placed 30 cm below soil surface and tensiometer was used as soil moisture sensor. Three tensiometer treatments placed at 10 (SDI-T10), 20 (SDI-T20) and 30 cm (SDI-T30) depths below soil surface under SDI. These are also compared to SUR-T20 treatment where tensiometer placed at 20 cm below soil surface under surface drip irrigation (SUR) systems. The growth of cucumber was not statistically different between SUR and SDI without SDI-T30 treatment. Fruit yields (Mg/ha) were 57.0 and 56.9 (SDI-T10), 56.0 and 60.5 (SDI-T20), 40.9 and 41.2 (SDI-T30) and 56.6 and 54.3 (SUR-T20) for 2010 and 2011, respectively. Slightly higher total yield was observed in tensiometer placed 20 cm below the soil surface, although no significant differences were found between SDI-T10 and SDI-T20 under SDI treatments. In addition, nitrogen application rates and daily irrigation rates were lowest in SDI-T20 compared with other SDIs and SUR treatments. Nitrogen and daily irrigation application under SDI-T20 was lower than that under SUR-T20 by 6.0%. These findings suggested tensiometer 20 cm depth under SDI systems was best for cucumber production in greenhouse.

Effects of Changes of Nutrient Solution Concentration According to Growth Stage on Growth and Flowering of Cut Chrysanthemum Grown Hydroponically in Perlite (국화의 펄라이트 양액재배시 생육단계에 따른 양액농도의 변화가 생육과 개화에 미치는 영향)

  • Ji, Eun Young;Oh, Wook;Kim, Sun Hwa;Kim, Ki Sun
    • Horticultural Science & Technology
    • /
    • v.16 no.2
    • /
    • pp.247-250
    • /
    • 1998
  • This study was carried out to investigate the effects of changes of ionic strength according to growth stage on growth and flowering of Dendranthema grandiflorum (Ramat.) Kitamura 'Seiun' grown hydroponically in perlite. The stage I, II, and III covered early vegetative growth (27-40 days after planting), latter vegetative growth (41-54 days), and reproductive growth (55-80 days), respectively. The 2 strength (1S and 2S) of nutrient solution were treated in stage I, whereas 3 strengths (1S, 1-2S, and 2S) were treated in stage II. Then, total 9 treatments in stage III were designated by 3 treatments (tap water, 1S, and 2S) for each 3 strengths in stage II. Each nutrient solution was applied 8 times per day. At vegetative growth stage (54 days after planting), stem length was highest when irrigated 8 times a day with 1S nutrient solution. Both photosynthesis and transpiration rate were higher in 1S than those in other treatments (1-2S, 2S), whereas leaf chlorophyll content was highest in 2S treatment. Ion content of plant treated with 2S was higher than other treatments. Growth (plant height, leaf area, stem length), fresh weight, and dry weight of each plant organ after flower bud formation were better in tap water treatment (1-1-0) than other 1S treatments (1-1-1, 1-1-2). Regarding the number of days to flowering, tap water treatment was the most effective. Thus, after flower bud formation supplying tap water or lower concentration of nutrient solution than those used during the vegetative growth stage was economical in saving chemical fertilizers, shortening the number of days to flowering, reducing salt accumulation in media, saving efforts of leaching, and reducing ground water contamination.

  • PDF

A Study on the Chemical Resistance Performance of Injection Type Leakage Repair Materials used in Crack Parts of Concrete Structures under the Contaminated Groundwater Environment (오염된 지하수 환경 하의 콘크리트 구조물 균열부위에 사용되는 주입형 누수보수재료의 화학저항성능 시험평가 연구)

  • Kim, Soo-Yeon;Yoo, Jae-Yong;Kim, Byung-Il;Oh, Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.5
    • /
    • pp.411-419
    • /
    • 2019
  • Underground concrete structures are constructed under a geographical environment called underground and exposed to various environments that promote deterioration. Among them, groundwater promotes deterioration of underground concrete structures due to contaminated water from the ground. In this study, the chemical resistance performance test evaluation of five different receptors for a total of 15-type leakage repair materials of five series was conducted to determine the chemical stability of the leakage repair material used in the crack area. The results show a general increase and decrease in most chemical receptors, but the biggest increase and decrease was shown in acrylic systems, which were found in sodium chloride and sodium hydroxide, and epoxy was found in hydrochloric acid. The cement system is showing a lot of increase and decrease in sodium chloride. It is expected that the results of these studies will be used as a basis for chemical stabilization in the development of new materials.

Microbiological Quality and Antibiotic Susceptibility of E. coli Isolated from Agricultural Water in Gyeonggi and Gangwon Provinces (경기, 강원 지역 농업용수의 미생물학적 특성 및 농업용수 분리 대장균의 항생제 내성)

  • Hwang, Injun;Park, Daesoo;Chae, Hyobeen;Kim, Eunsun;Yoon, Jae-Hyun;Rajalingam, Nagendran;Choi, Songyi;Kim, Se-Ri
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.4
    • /
    • pp.343-351
    • /
    • 2020
  • BACKGROUND: Irrigation water is known to be one of the major sources of bacterial contamination in agricultural products. In addition, anti-microbial resistance (AMR) bacteria in food products possess serious threat to humans. This study was aimed at investigating the prevalence of foodborne bacteria in irrigation water and evaluating their anti-microbial susceptibility. METHODS AND RESULTS: Surface water (n = 66 sites) and groundwater (n = 40 sites) samples were collected from the Gyeongi and Gangwon provinces of South Korea during April, July, and October 2019. To evaluate the safety of water, fecal indicators (Escherichia coli) and foodborne pathogens (E. coli O157:H7, Salmonella spp., and Listeria monocytogenes) were examined. E. coli isolates from water were further tested for antimicrobial susceptibility using VITEK2 system. Overall, detection rate of foodborne pathogens in July was highest among three months. The prevalence of pathogenic E. coli (24%), Salmonella (3%), and L. monocytogenes (3%) was higher in surface water, while only one ground water site was contained with pathogenic E. coli (2.5%). Of the 343 E. coli isolates, 22.7% isolates were resistant to one or more antimicrobials (ampicillin (18.7%), trimethoprim-sulfamethoxazole (7.0%), and ciprofloxacin (6.7%)). CONCLUSION: To enhance the safety of agricultural products, it is necessary to frequently monitor the microbial quality of water.

Geoenvironmental Influence on the Recycled Soil from Demolition Concrete Structures for using in Low Landfilling (건설폐토석의 성토에 따른 지반환경적 영향)

  • Shin, Eun-Chul;Kang, Jeong-Ku;Ahn, Min-Hee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.12
    • /
    • pp.21-30
    • /
    • 2011
  • The recycled soil that is proceeded from demolition concrete structures was analyzed by the methods of the physical and mechanical tests of soil and TCLP test to use the soil in low landfilling for the construction of an industrial complex. The laboratory test for diffusion of alkali ion in soil mass was analyzed by the methods of XRF and ICP. The fish toxicity test was also conducted to find an environmental influence. The recycled soil through the laboratory test satisfied the engineering property for low landfilling and the criteria of soil contamination. However, the solution which producted by 1:1 ratio of recycled soil and water contained the high pH concentration by alkali ion. The calcium hydroxide solution by CSH cement paste was estimated as the main reason why pH concentration is increased more than 9.0. The high pH concentration in recycled soils causes a toxicity to the livability of fishes. A diffusion area of pH concentration in the ground was analyzed by the Visual Modflow Ver. 2009 program based on geotechnical investigation. The high pH concentration in the recycled soils can be remained as high value due to cement paste in the long term period. Therefore, in the early stage of landfilling work, the mixing with the weathered granite soil is necessary to control the pH concentration.

The Effects of Fertilization on Growth Performances and Physiological Characteristics of Liriodendron tulipifera in a Container Nursery System (시비 처리가 백합나무 용기묘의 생장 및 생리적 특성에 미치는 영향)

  • Cho, Min Seok;Lee, Soo Won;Park, Byung Bae;Park, Gwan Su
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.2
    • /
    • pp.305-313
    • /
    • 2011
  • Fertilization is essential to seedling production in nursery culture, but excessive fertilization can contaminate surface and ground water around the nursery. The objective of this study was to find optimal fertilization practice of container seedling production for reducing soil and water contamination around the nursery without compromising seedling quality. This study was conducted to investigate growth performance, photosynthesis, chlorophyll fluorescence, and chlorophyll contents of Liriodendron tulipifera growing under three different fertilization treatments (Constant rate, Three-stage rate, and Exponential rate fertilization). Root collar diameter, height, and biomass of L. tulipifera were the highest at Constant treatment. Like growth performance, seedling quality index (SQI) were higher at Constant than at other treatments, but not significantly different among treatments. L. tulipifera showed good photosynthetic capacity at all treatments. Photochemical efficiency and chlorophyll contents were significantly lower at Exponential than at other treatments. Therefore, Exponential fertilization which is 50% fertilizer of other treatments would maximize seedling growth and minimize nutrient loss.

Detection of Toluene Hazardous and Noxious Substances (HNS) Based on Hyperspectral Remote Sensing (초분광 원격탐사 기반 위험·유해물질 톨루엔 탐지)

  • Park, Jae-Jin;Park, Kyung-Ae;Foucher, Pierre-Yves;Kim, Tae-Sung;Lee, Moonjin
    • Journal of the Korean earth science society
    • /
    • v.42 no.6
    • /
    • pp.623-631
    • /
    • 2021
  • The increased transport of marine hazardous and noxious substances (HNS) has resulted in frequent HNS spill accidents domestically and internationally. There are about 6,000 species of HNS internationally, and most of them have toxic properties. When an accidental HNS spill occurs, it can destroys the marine ecosystem and can damage life and property due to explosion and fire. Constructing a spectral library of HNS according to wavelength and developing a detection algorithm would help prepare for accidents. In this study, a ground HNS spill experiment was conducted in France. The toluene spectrum was determined through hyperspectral sensor measurements. HNS present in the hyperspectral images were detected by applying the spectral mixture algorithm. Preprocessing principal component analysis (PCA) removed noise and performed dimensional compression. The endmember spectra of toluene and seawater were extracted through the N-FINDR technique. By calculating the abundance fraction of toluene and seawater based on the spectrum, the detection accuracy of HNS in all pixels was presented as a probability. The probability was compared with radiance images at a wavelength of 418.15 nm to select abundance fractions with maximum detection accuracy. The accuracy exceeded 99% at a ratio of approximately 42%. Response to marine spills of HNS are presently impeded by the restricted access to the site because of high risk of exposure to toxic compounds. The present experimental and detection results could help estimate the area of contamination with HNS based on hyperspectral remote sensing.

Evaluation of Environmental Stability and Durability of Cementitious Mixed Soil (시멘트계 혼합토의 환경안정성 및 내구성 평가)

  • Oh, Sewook;Bae, Wooseok;Kim, Hongseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.9
    • /
    • pp.17-23
    • /
    • 2022
  • Using cement as a road subbase is economical, easily modified and supplemented and has excellent road pavement quality control. In addition, cement adheres well to sandy soils without adhesion, and it plays a role of permanently preserving adhesion in viscous soils with adhesion, so it can be widely applied as stable treatment with the advantages of increased strength, reduced compressibility. and improved durability. However, while cement is excellent in terms of strength for a road subbase, the material properties mean that it is difficult to maintain and reinforce when cracks or fractures occur due to dry shrinkage, and the pH increases in the ground due to hexavalent chromium eluting from cement. which can cause environmental problems such as groundwater contamination. Therefore, this study evaluates the usability of alternatives in the road base layer such as environmentally cementitious stabilizer and on-site soil generated from the site. We intend to reduce the environmental damage and evaluate the durability. To evaluate the applicability of the site, Environmental stability test and freeze-thaw test and wetting-drying test was conducted to evaluate the strength characteristics of alternative materials on the road through the limited performance evaluation of environmentally cementitious stabilizer. The test ranges were set at mixing ratios of 10%, 20%, and 30% and ages of three days, and 28 days old to evaluate the early strength and reference strength according to the mixing ratio of the environmentally cementitious stabilizer.

Analysis of Bacterials Community Structure in Leadchate-Contaminated Groundwater using Denaturing Gradient Gel Electrophoresis (Denaturing Gradient Gel Electrophoresis를 이용한 매립지 침출수로 오염된 지하수의 세균 군집 분석)

  • Kim Jai-Soo;Kim Ji-Young;Koo So-Yeon;Ko Kyung-Seok;Lee Sang-Don;Cho Kyung-Suk;Koh Dong-Chan
    • Microbiology and Biotechnology Letters
    • /
    • v.34 no.2
    • /
    • pp.166-173
    • /
    • 2006
  • This research has been performed to clarify the relationship between hydrogeochemistry and bacterial community structure in groundwater contaminated with landfill leachate. We collected and analyzed samples from 5 sites such as leachate (KSG1-12), treated leachate (KSG1-16), two contaminated groundwaters (KSG1-07 and KSG1-08) and non-contaminated groundwater (KSG1-13). pH was 8.83, 8.04, 6.87, 6.87 and 6.53 in order; redox potential (Eh) 108, 202, 47, 200 and 154 mV; electric conductivity (EC) 3710, 894, 1223, 559 and 169.9 $\mu$S/cm; suspended solids (SS) 86.45, 13.74, 4.18, 0.24 and 11.91 mg/L. In KSG01-12, the ion concentrations were higher especially in $Cl^-$ and $HCO_3^-$ than other sites. The concentrations of Fe, Mn and $SO_4^{2-}$ were higher In KSG1-07 than in KSG1-08, and vise versa in $NO_3^{2-}$. In the comparison of DGGE fingerprint patterns, the similarity was highest between KSG1-13 and KSG1-16 (57.2%), probably due to common properties like low or none contaminant concentrations. Otherwise KSG1-08 showed lowest similarities with KSG1-13 (25.8%) and KSG1-12 (27.6%), maybe because of the degree of contamination. The most dominant bacterial species in each site were involved in $\alpha$-Proteobacteria (55.6%) in KSG1-12, $\gamma$-Proteobacteria (50.0%) in KSG1-16, $\beta$-Proteobacteria (66.7%) in KSG1-07, $\gamma$-Proteobacteria (54.5%) in KSG1-08 and $\beta$-Proteobacteria (36.4%) in KSG1-13. These results indicate that the microbial community structure might be changed according to the flow of leachate in grounderwater, implying changes in concentrations of pollutants, available electron accepters and/or other environmental conditions.

Evaluation of Standardized Uptake Value applying Prompt Gamma Correction on 68Ga-DOTATOC PET/CT Image (68Ga-DOTATOC PET/CT에서 Prompt Gamma Correction을 적용한 SUV의 평가)

  • Yoon, Seok Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • $^{68}Ga$ was eluted from a $^{68}Ge/^{68}Ga$ radionuclide generator. $^{68}Ga$ decays into $^{68}Zn$, with a half life=67.8min. The decay is 88.9 % by ${\beta}$+ and 11.1 % by EC. The main ${\beta}$+ decay (87.7 %) is to the ground level of $^{68}Zn$ and it is a pure positron emission branch. A small fraction decays ${\beta}$+ (1.2 %) into an excited level of $^{68}Zn$, which promptly decays into the ground level with a ${\gamma}$ (1.077 Mev). This can constitute prompt gamma contamination in the PET data, if the 1.077 Mev ${\gamma}$ has a scatter interaction in the patient, and generates a lower energy ${\gamma}$ in coincidence with the positron annihilation pair. The purpose of this study was to evaluate standardized uptake value(SUV) before and after applying prompt gamma rays correction on $^{68}Ga$-DOTATOC PET/CT image. Fifty patient underwent PET/CT 1 hour after injection of the $^{68}Ga$-DOTATOC. The SUVmax and SUVmean of lesions and normal tissues (Pituitary, Lung, Liver, Spleen, Kidney, Intestine) were evaluated before and after applying prompt gamma correction on $^{68}Ga$-DOTATOC PET/CT image. Additionally, the SUVmax of each lesions and SUVmean of the soft tissues were measured on images. and target to background ratios (TBR) were calculated as quantitative indices. Among 15 patients, 25 of lesions (Pancreas, Liver, Thoracic Spine, Brain) with increased uptake on $^{68}Ga$-DOTATOC PET/CT image. SUVmax and SUVmean were increased in lesion site and normal tissue after prompt gamma rays correction. TBR was $51.51{\pm}49.28$ and $55.50{\pm}53.12$ before and after prompt gamma rays correction, respectively. (p<0.0001)