• 제목/요약/키워드: Ground characteristics

검색결과 4,597건 처리시간 0.036초

고로슬래그미분말을 사용한 고유동콘크리트의 특성 (Properties of Self Compacting Concrete Using Ground Granulated Blast Furnace Slag)

  • 김은겸;박천세;전찬기;이호석;최재진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.579-584
    • /
    • 2002
  • In this research, the physical properties of self compacting concrete using ground granulated blast furnace slag as a part of cement were investigated. Concrete using ground granulated blast furnace slag was prepared with various ground granulated blast furnace slag replacement(20~80 volume %) for cement and the quantities of coarse aggregate in concrete were 50%, 55% and 60% of ratio of absolute volume of coarse aggregate. The workability, flowing characteristics, air content and compressive strength of concrete using ground granulated blast furnace slag were tested and the results were compared with those of ordinary portland cement concrete. In the experiment, we acquired satisfactory results at the point of flowing characteristics and strengths of concrete using ground granulated blast furnace slag within tile replacement ratio of 50% and the optimum quantity of coarse aggregate in concrete was found to be 50%~55% of ratio of absolute volume of coarse aggregate.

  • PDF

보조전극의 배치 및 주파수에 따른 매설지선의 접지임피던스 특성 (Characteristics for Ground Impedance of Counterpoise according to Position of Auxiliary Probe and Frequency)

  • 길형준;김동우
    • 한국안전학회지
    • /
    • 제27권4호
    • /
    • pp.33-37
    • /
    • 2012
  • This paper describes the characteristics for ground impedance of counterpoise according to position of auxiliary probe and frequency using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position of auxiliary probes. In order to analyze the effects of ground impedance due to the distance of the current probe and frequency, ground impedances were measured in case that the distance of current probe was located from 10[m] to 100[m] and the measuring frequency was ranged in 55 [Hz], 128[Hz], 342[Hz], and 513[Hz]. The results could be help to determine the position of auxiliary probe when the ground impedance was measured at grounding system.

매립 지반에서의 지진파 증폭 특성 (Seismic Motion Amplification Characteristics at Reclaimed Ground)

  • 김용성;김기영;전제성
    • 한국농공학회논문집
    • /
    • 제47권5호
    • /
    • pp.51-61
    • /
    • 2005
  • In this study, borehole records were analyzed to verify the amplification of seismic motion at the soft reclaimed ground before and after the main event of the 1995 Hyogoken Nambu Earthquake at Port Island, Japan. From the analysis, it was shown that the amplification of seismic motion occurred near the soft ground surface (within 30 m below) where confining stress is low. Moreover, it was found that recovery of dynamic soil stiffness at the liquefied ground began gradually 3 hours after the liquefaction and completed in 10 days, when the ground exhibited the same seismic motion characteristics as those before the liquefaction.

근거리 지진에 의한 현수교의 동적응답특성 (Dynamic Response Characteristics of the Suspension Bridge Subjected to Near Fault Ground Motions)

  • 한성호;이강혁;유병률;방명석;신재철
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.484-491
    • /
    • 2004
  • In this study, the effect of the Near Fault Ground Motion which hasn't been considered at the domestic seismic design is demonstrated through the seismic response analysis of suspension bridge. After selecting the typical Near and Far Fault Ground Motion, the response characteristics are analysed by conducting the seismic response analysis about the long period suspension bridge which is expected to suffer the effect of Near Fault Ground Motions more largely. According to the results of this study, the Near Fault Ground Motions affect the suspension bridge more considerably than the Far Fault Ground Motions.

  • PDF

고로슬래그미분말 및 플라이애쉬를 사용한 고유동콘크리트의 특성에 관한 연구 (Properties of Self-Compacting Concrete Using Ground Granulated Blast Furnace Slag and Fly ash)

  • 김은겸;박천세;최재진;전찬기;이호석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.89-94
    • /
    • 2003
  • In this research, the physical properties of self compacting concrete using ground granulated blast furnace slag and fly ash as a part of cement were investigated. Concrete using ground granulated blast furnace slag and fly ash was prepared with various ground granulated blast furnace slag(30-50 volume %) and fly ash(10-20 volume %) replacement for cement. The effect of each of the materals, which have effects on self compacting concrete made by the basic mix proportion used granulated blast furnace slag and fly ash after hardening, has been checked. The workability, flowing characteristics, resistance of segregation of materals, air content, and compressive strength of concrete using ground granulated blast furnace slag and fly ash were tested and the results were compared with those of ordinary portland cement concrete. In the experiment, we acquired satisfactory results at the point of flowing characteristics and strengths of concrete using ground granulated blast furnace and slag fly ash within the replacement ratio of 65%

  • PDF

열교환방식에 따른 지열히트펌프의 난방특성에 관한 연구 (A Study on Heating Characteristics of Ground Source Heat Pump with Variation of Heat Exchange Methods)

  • 차동안;권오경;박차식
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.9-15
    • /
    • 2012
  • The objective of this study is to investigate the influence on the heating performance for a water-to-water 10RT ground source heat pump by using the water switching and refrigerant switching method. The test of water-to-water ground source heat pump was measured by varying the compressor speed, load side inlet temperature, and ground heat source side temperature. The heating capacity and COP of the heat pump increased with increasing ground heat source temperature. As a result, compared to a refrigerant switching method, the water switching method with counter flow improves the heating capacity and COP by approximately 5% in average, respectively.

Characterization of earthquake ground motion of multiple sequences

  • Moustafa, Abbas;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • 제3권5호
    • /
    • pp.629-647
    • /
    • 2012
  • Multiple acceleration sequences of earthquake ground motions have been observed in many regions of the world. Such ground motions can cause large damage to the structures due to accumulation of inelastic deformation from the repeated sequences. The dynamic analysis of inelastic structures under repeated acceleration sequences generated from simulated and recorded accelerograms without sequences has been recently studied. However, the characteristics of recorded earthquake ground motions of multiple sequences have not been studied yet. This paper investigates the gross characteristics of earthquake records of multiple sequences from an engineering perspective. The definition of the effective number of acceleration sequences of the ground shaking is introduced. The implication of the acceleration sequences on the structural response and damage of inelastic structures is also studied. A set of sixty accelerograms is used to demonstrate the general properties of repeated acceleration sequences and to investigate the associated structural inelastic response.

Research on Ground Temperature Restoration Characteristics of Large-Scale Ground Source Heat Pump System

  • Zhang, Xu;Liu, Jun;Gao, Jun;Li, Kuishan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권4호
    • /
    • pp.109-116
    • /
    • 2008
  • Ground temperature restoration characteristics are the crucial factors to evaluate whether a ground source heat pump system can keep long time steady operation. They are mainly dependent on soil thermal properties, layout of pile group, operation/shutoff ratio, cooling/heating load, thermal imbalance ratio and so on. On the one hand, several types of vertical pile foundation heat exchangers are intercompared to determine the most efficient one by performance test and numerical method. On the other hand, according to the layout of pile group of a practical engineering and running conditions of a GSHP system in Shanghai, the temperature distribution during a period of five years is numerically studied. The numerical results are analyzed and are used to provide some guidance for the design of large-scale GSHP system.

항공기 탑재 시험을 통한 지상 클러터 반사계수 추정 (Estimation of Ground Clutter Reflectivity based on the CFT(Captive Flight Test))

  • 손창희
    • 한국군사과학기술학회지
    • /
    • 제9권2호
    • /
    • pp.87-95
    • /
    • 2006
  • The performance of a microwave missile seeker and radar operating in an air-to-air look-down mode is strongly influenced by the presence of ground clutter In order to correctly account for the effects of ground clutter, it is required to develop a model capable of representing clutter characteristics as a function of range and/or frequency. In this paper, a program to estimate the clutter reflectivity for various ground conditions is developed, using the actually measured data and the data available from open literatures. In addition, clutter characteristics measured for various ground conditions such as sea, agricultural area, urban city and industrial area through the captive flight tests are presented.

Propagation Analysis of DGPS Antenna for Radial Ground and Obstacle

  • Kim, Young-Wan
    • Journal of information and communication convergence engineering
    • /
    • 제9권4호
    • /
    • pp.363-368
    • /
    • 2011
  • The DGPS transmits the enhancement signal to GPS using the medium frequency band. The NDGPS service that covers the Korean peninsula has been started since 2009. The service area of ocean-based DGPS(maritime-DGPS) reference stations covers the 100NM, but land-based DGPS(land-DGPS) covers 80km service area less than that of maritime DGPS. The DGPS's antenna has the top-loaded monopole antenna type. Top-loaded monopoles are the logical antennas to be used in order to get a low profile antenna and a performance according to the broadcaster and communication needs. The antenna needs to get the ground plane with good conductivity characteristics and flat ground plane without obstacle near to the transmitting antenna. In this paper, the radiation characteristics of an equivalent MF antenna are analyzed in view points of the ground conductivity and the ground plane with obstacle near to the antenna.