• 제목/요약/키워드: Ground Temperature

검색결과 1,607건 처리시간 0.029초

Effect of curing temperature on the properties of ground granulated blast furnace slag-cement bentonite slurry

  • Kim, Taeyeon;Lee, Bongjik;Hong, Seongwon
    • Geomechanics and Engineering
    • /
    • 제29권3호
    • /
    • pp.237-247
    • /
    • 2022
  • To investigate the curing temperature effect on the engineering properties of ground granulated blast furnace slag-cement bentonite (GGBS-CB) slurry for cutoff walls, the laboratory experiments including the setting time, unconfined compressive strength, and permeability tests were carried out. The mixing procedure for GGBS-CB slurry was as follows: (1) montmorillonite-based bentonite slurry was first fabricated and hydrated for four hours, and (2) cement or GGBS with cement was added to the bentonite slurry. The dosage range of GGBS was from 0 to 90 % of cement by mass fraction. The GGBS-CB slurry specimens were cured and stored in environmental chamber at temperature of 14±1, 21±1, 28±1℃ and humidity of 95±2% until target days. The highest average temperature of three seasons in South Korea was selected and used for the tests. The experimental results indicated that in early age (less than 28 days) of curing the engineering properties of GGBS-CB slurry were primarily affected by the curing temperature, whereas the replacement ratio of GGBS became a main factor to determine the properties of the slurry as the curing time increased.

심부지열 용 동축 열교환기 성능예측을 위한 열전달 실험 및 해석 (Heat Transfer Experiment and Analysis to Predict the Efficiency of Heat Exchanger for Deep Geothermal System)

  • 정국진;정윤성;박준수;이동현
    • 융복합기술연구소 논문집
    • /
    • 제7권1호
    • /
    • pp.1-6
    • /
    • 2017
  • The Heat exchanger for deep geothermal system is very important to enhance the efficiency of the system. The co-axial heat exchanger is used due to the limitation of digging space. The heat transfer on the external surface of outer pipe should be high to receive a large amount of heat from the ground. However, the inner pipe should be insulated to reduce the heat loss and increase the temperature of discharge water. This study made experiment apparatus to describe the co-axial heat exchanger and measure the heat transfer coefficients on the internal and external surface. And the pin-fin was designed and fixed on the internal surface to increase the efficiency of heat exchanger. Finally, we calculated the temperature of discharge water using the heat transfer circuit of co-axial heat exchanger and heat transfer coefficient which from experimental results. The water temperature was reached the ground temperature at -500 m and following the ground temperature. When the water return to the ground surface, the water temperature was decreased due to heat loss. As the pin-fin case, the heat transfer coefficient on the internal surface was decreased by 30% and it mean that the pin-fin help to insulate the inner pipe. However, the discharge water temperature did not change although pin-fin fixed on the inner pipe.

Applications of Time-Temperature Integrator (TTI) as a Quality Indicator of Grounded Pork Patty

  • Chun, Ji-Yeon;Choi, Mi-Jung;Lee, Seung Ju;Hong, Geun-Pyo
    • 한국축산식품학회지
    • /
    • 제33권4호
    • /
    • pp.439-447
    • /
    • 2013
  • Time-temperature integrators (TTIs) are simple and cost-efficient tools which may be used to predict food quality. Enzymatic TTIs are devised to indicate food quality in the form of color alterations from green to red, based on the cumulative impacts of temperature and time period on the enzymatic reactions. In this study, the quality of ground beef patties was investigated for the parameters of pH levels, color, VBN, water holding capacity, and total microbial counts, depending on various storage temperatures (5, 15, and $25^{\circ}C$). TTIs were attached to the surface of the ground beef patties in order to evaluate the degree of correlating colorimetric changes with the determined quality parameters. Through the Arrhenius equation, activation energy and constant reaction rates of TTI, VBN, and total microbial counts were calculated as to observe the relationship between enzymatic reactions of the TTI and food spoilage reactions of the ground beef patties. VBN and total microbial counts were already increased to reach decomposition index (VBN: 20, total microbial count: 7-8 Log CFU/g) of meat at middle stage of storage period for each storage temperature. Although activation energy of TTI enzymatic reactions and food spoilage reactions of the ground beef patties were similar, the change of TTI color was not a coincidence for food spoilage at $5^{\circ}C$ and $15^{\circ}C$ of storage temperature. It was suggested that TTI should be designed individually for storage temperature, time, type of meat, or decomposition index of meat.

열수송관의 누수에 대한 열-수리적 수치해석 (Thermo-hydraulic Numerical Analysis for the Leakage of Buried District Heating Pipe)

  • 신호성;홍승서
    • 한국지반공학회논문집
    • /
    • 제38권3호
    • /
    • pp.17-26
    • /
    • 2022
  • 국내의 지역난방을 위해 지중에 매설된 열수송관은 노후화로 인한 손상을 감지하기 위하여 지표면 온도변화에 기반한 안전관리 기준이 필요하다. 본 논문은 열수송관의 매설과 누수로 인한 지표면 온도 변화에 대하여 수치해석을 수행하였다. 열수송관이 매설된 지면과 주변지면의 온도차는 오전3시~오전8시에 가장 크게 나타났으며, 하절기 보다는 동절기에 온도차가 크게 발생하였다. 지하수위의 하강은 열수송관에 의한 지표면의 온도 증가를 크게 하고, 아스팔트 지면조건은 토사 지면조건에 비하여 지하수위 변화의 영향이 작게 나타났다. 열수송관의 누수가 없는 경우, 열수송관에 의한 지표면 온도 상승은 토사지반에서 3.0℃, 아스팔트 포장에서는 3.5℃이내로 나타났다. 토사 지면조건에서 열수송관의 누수에 의한 지면온도 변화는 하절기에는 완만하게, 동절기에는 급격하게 상승하였다. 아스팔트 포장조건은 토사 지면조건보다 누수에 의한 지표면의 온도 상승폭과 상승률이 작게 나타났다. 그리고 공급관의 양측 누수에 의하여 수송관 상부 지면과 주변지면의 온도차이가 10℃에 도달하는데 1~2일 정도 소요되었다.

지하수 열원 복수정 지열 열펌프 시스템의 성능에 관한 실험적 연구 (An Experimental Study of Ground Water Source Two Well Type Geothermal Heat Pump System)

  • 임효재;권정태;김창업;공형진;박성구
    • 설비공학논문집
    • /
    • 제21권8호
    • /
    • pp.468-474
    • /
    • 2009
  • Ground water source heat pump system is the oldest one of the ground source heat pump systems. Despite of this, little formal design information has been available until recently. The important design parameters for open system are the identification of optimum ground water flow, heat exchanger selection and well pump. In this study, the capacity of 50 RT system of two well type ground water heat pump system was used. As a result, static water level was -7 m and the level during the heating operation was -32 m, cooling operation was -40 m. The initial static water level recovered within 48 hrs. The temperature of ground water is $15.6^{\circ}C$ for heating season and $16.2^{\circ}C$ for cooling season and does not depend on the outdoor temperature. Operation efficiency of the system shows that, COP 3.1 for heating and COP 4.2 for cooling.

지역 기후가 유닛형 지중열교환기 성능에 미치는 영향 (Analysis on the Effect of Local Climate on the Unit-type Ground Heat Exchanger)

  • 배상무;김재민;남유진
    • 한국태양에너지학회 논문집
    • /
    • 제39권1호
    • /
    • pp.67-76
    • /
    • 2019
  • A ground source heat pump (GSHP) system can stable system operation by using underground heat source and has high reliability for energy production. However, wide-spread of the GSHP system is delayed to high initial investment costs. In previous studies, horizontal and unit-type ground heat exchanger (GHX) have developed to overcome disadvantages such as high initial cost. However, these performances of GHXs are greatly influenced by climate and weather conditions. It is necessary to analyze the performance of GHX according to the ground temperature change in the installation site. In this study, the ground temperature of each installation site confirmed and performance of unit-type GHX quantitatively analyzed by numerical analysis. As the result, the performance of the unit type GHX was 33.9 W/m in Seoul, 34.2 W/m in Daejeon, and 37.2 W/m in Busan.The result showed the difference performance of GHX according to local climate was maximum of 9.7%.

다양한 대기풍속 및 대기온도 구배 조건에서의 공장 배출 가스의 확산 특성에 관한 연구 (A Study for Characteristics of Stack Plume Dispersion under Various)

  • 박일석
    • 설비공학논문집
    • /
    • 제22권11호
    • /
    • pp.773-780
    • /
    • 2010
  • The dispersion of plume which is emitted from a chimney is governed by a lot of factors: wind, local terrain, turbulence intensity of atmosphere, and temperature, etc. In this study, we numerically investigate the plume dispersions for various altitudinal temperature gradients and wind speeds. The normal atmosphere has the temperature decrease of $0.6^{\circ}C/100m$, however, actually the real atmosphere has the various altitudinal temperature profiles according to the meteorological factors. A previous study focused on this atmospheric temperature gradient which induces a large scale vertical flow motion in the atmosphere thus makes a peculiar plume dispersion characteristics. In this paper, the effects of the atmospheric temperature gradient as well as the wind speed are investigated concurrently. The results for the developing processes in the atmosphere and the affluent's concentrations at the ambient and ground level are compared under the various altitudinal temperature gradients and wind speeds.

식물의 온도 완화효과에 관한 기초적 연구 (A Quantitative Study on the Effect of Temperature Control by a Shade Tree and the Lawn Area)

  • 안계복;김기선
    • 한국조경학회지
    • /
    • 제14권1호
    • /
    • pp.1-13
    • /
    • 1986
  • The purpose of this study is to investigate the effect of temperature control by a shade tree and the lawn area. In this investigation, we find out that artificial-lawn, concerte, and exposed soil are more higher temperature than covered with plant materials. The results of the measurement may to summerized as follows; 1) Low-temperature effects of zoysia japonica is more controlled by condition of growth than leaf length of grass. Surface temperature make 0.7$^{\circ}C$ difference between long grass (15cm), and short grass (5cm), but make 5$^{\circ}C$ difference between good growth grass (230/10$\textrm{cm}^2$) and bad growth grass (80/10$\textrm{cm}^2$). 2) The surface temperature of the lawn area is 40.5$^{\circ}C$ lower on a maxinum than that of the artificial lawn (July 28, 1985). During the day of summer, shade area under the shade tree is 0.9$^{\circ}C$ lower then lawn area surface temperature, 6.9$^{\circ}C$ lower than bad growth lawn, 10.3$^{\circ}C$ lower than exposed soil, and 18$^{\circ}C$ lower than concrete surface temperature. 3) Natural irrigation effect on the surface temperature fluctuation. But this effect is changed by compositions of ground materials and time-lapse. 4) Sunny day is more effective than cloud day. 5) In summer season, surface temperature make a difference compare to temperature of 0.5-1.5m height from ground : Surface temperature is 3.4$^{\circ}C$ lower at the lawn area (11 a.m.), 4.2$^{\circ}C$ lower at the shade area the shade tree, 12.7$^{\circ}C$ higher at the concrete area (3p.m.), 38.8$^{\circ}C$ higher at the artificial lawn (2p.m.) 6) According to compositions of ground materials and season have specific vertical temperature distribution curve. 7) In summer season, temperature distribution of 0.5-1.5m hight at the shade tree is 4.8-5.7$^{\circ}C$ lower than concrete area (noon-3p.m.)

  • PDF

한국의 지중온도를 이용한 기후변화연구 (Climate change in Korea inferred from subsurface temperatures)

  • 이영민;김형찬;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.442-444
    • /
    • 2006
  • On long time scale and over large areas ground surface temperatures (GSTs) track surface air temperatures (SATs). Additionally, GST changes penetrate into the subsurface and are recorded as transient temperature perturbation to the background thermal filed. Therefore, climate change can be reconstructed from borehole temperature measurements We present GST hi story reconstructed from temperature measurements in a borehole at Pocheon The result shows that GST cold period in the late 19th century and then increased by about 2K to 1990. GST history matches well with surface air temperatures measured from 1907 to 2001 at the Seoul Meteorological Station and GST history reconstructed from temperature measurements in three boreholes at Ulsan.

  • PDF

지중열교환기 설치 조건이 지중 유효 열전도도에 미치는 영향 (Effect of Some Parameters on Ground Effective Thermal Conductivity)

  • 최재호;임효재;공형진;손병후
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.33-38
    • /
    • 2008
  • A ground-loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. The Size and performance of this heat exchanger is highly dependent on ground thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U-tube configurations on ground effective thermal conductivity. In this study, thermal response tests were conducted using a testing device with 9-different ground-loop heat exchangers. From the experimental results, the length of ground-loop heat exchanger affects to the effective thermal conductivity. Among the various grouting materials, the bentonite-based grout with silica sand shows the largest thermal conductivity value.

  • PDF