• Title/Summary/Keyword: Ground Temperature

Search Result 1,603, Processing Time 0.029 seconds

Effect of PE Film Mulching and Irrigation Method on the Growth, Yield and Antioxidant Activity for Potatoes Grown in Winter Season at Saemangeum Reclaimed Land (새만금 간척지에서 감자 겨울재배시 비닐멀칭 및 관수방법이 생육, 수량 및 괴경의 항산화 활성에 미치는 영향)

  • Choi, Weon-Young;Cho, Kwang-Min;Kim, Sun;Jeong, Jae-Hyeok;Lee, Su-Hwan;Lee, Kyeong-Bo;Lee, Geon-Hwi;Park, Ki-Hun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.60 no.1
    • /
    • pp.63-69
    • /
    • 2015
  • This study was conducted to measure the effect of PE film mulching and irrigation methods on the growth, yield and antioxidant activity of potatoes tubers, in order to examine the possibility of cultivating potatoes in winter season in vinyl greenhouse on the reclaimed tidal land with weak ground inside the sea wall currently completed. The test was conducted on the sandy loam soil (Munpo series), and its salt concentration was 0.42% at the time of planting. The emergence speed per kind of PE film mulching was in the order of black > coloration > transparent > green color, with the black color showing the fastest speed. The temperature change during a day per kind of PE film mulching was in the order of transparent > coloration > green > black color. As for the salt concentration in the soil for each different way of water management, the salt concentration in the treatment of drip irrigation with 1 week interval was lower than that drip irrigation with 2 weeks interval. As for the growth of above-aerial part, plant length was higher, number of tiller and leaves were more and dry weight of above-aerial part was larger in the treatment of drip irrigaton with 1 week interval than drip irrigation with 2 weeks interval. As for the yield of potatoes depending on each way of water management, the yield in the treatment of drip irrigation with 1 week interval was more than drip irrigation with 2 weeks interval. The yield for each different kind of PE film mulching in the weekly drip-irrigation management section was in the order of transparent ${\geq}$ black ${\geq}$ coloration ${\geq}$ green color. In both of total phenol content and DPPH free radical activity experiments, the content and activity were higher with pear color vinyl treatment.

Overwintering pattern of larvae of Chilo suppressalis Walker in the bioenergy crop Miscanthus sacchariflorus cv. Geodae 1 (바이오에너지작물 거대억새 가해 해충 이화명나방 유충 월동양상)

  • An, Gi Hong;Yang, Jungwoo;Jang, Yun-Hui;Um, Kyoung Ran;Kim, Seok;Cha, Young-Lok;Yoon, Young-Mi;Moon, Youn-Ho;Ahn, Joung Woong;Yu, Gyeong-Dan
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.59 no.3
    • /
    • pp.369-374
    • /
    • 2014
  • The rice stem borer (Chilo suppressalis Walker) was one of the most destructive pest of rice for the 1960s and 1970s in Korea. Recently, it is newly recognized as a potential risk factor to the biomass yield of bioenergy crops. The current research was firstly conducted to investigate overwintering larvae population density and pattern of rice stem borer attacking Miscanthus sacchariflorus cv. Geodae 1 which is referred to as an ideal lignocellulosic bioenergy crop in Korea. Population density of larvae per $1m^2$ in stems and rhizomes at the Miscanthus experimental plots and rates of damage (wormhole, abscission) of M. sacchariflorus cv. Goedae 1 were investigated from October 2012 to March 2013. The population of larvae per $1m^2$ in stems of Miscanthus were 23, 4, 1, and 1 in October, November, December 2012, and January 2013, respectively. Over the same period, the population of larvae in basal stem rots and rhizomes were increased, whereas decreased in stems. Interestingly, the positions of larvae for overwintering in Miscanthus were confirmed to 5~10 cm below the soil surface such as basal stem rot and rhizome, whereas the most common overwintering position known in rice is a part of stem on the ground such as rice straw and rice stubble. It would suggest that the larvae gradually moved to bottom of stems and rhizomes in soil in line with decline in temperature. Moreover, the damage rates of stems per $1m^2$ were up to more than 50% in some places. In conclusion, this might be the first report that rice stem borer could affect the productivity of biomass of Miscanthus in case of mass cultivation. Moreover, it should be necessary to make a decision in insect control management for this bioenergy feedstock and other related crops.

Distribution of Microorganisms in the Marine Ranching Ground of Tongyong Coastal Waters (통영 연안 해역에서의 미생물 분포)

  • 장지철;김말남;이진환;김종만
    • Korean Journal of Environmental Biology
    • /
    • v.18 no.4
    • /
    • pp.403-409
    • /
    • 2000
  • Surface and bottom water samples were collected from 10 stations located in the coastal area of Tongyong in April, August and October 2000. Distribution of heterotrophic bacteria, coliform bacteria and fungi in the sea water samples was investigated by measuring the corresponding viable cell number according to the plate counting method. Heterotrophic bacteria in the surface water counted 3.1$\times$10$^2$- 4.0$\times$10$^3$cfu ml$\^$-1/, 2.7$\times$10$^3$- 1.2$\times$10$\^$5/cfu ml$\^$-1/ and 1.3$\times$10$^2$- 7.2$\times$10$^2$cfu ml$\^$-1/ in April, August and October, respectively. The cell number of coliform bacteria in the surface water amounted to 0-1.5$\times$10$^1$cfu ml$\^$-1/, 3.5$\times$10$^1$- 5.2$\times$10$^3$cfu ml$\^$-1/ and 0-1.8$\times$10$^2$cfu ml$\^$-1/ in April, August and October, respectively. As for fungi, the cell number in the surface water was 0-3.0$\times$10$^1$propagules ml$\^$-1/, 3.0$\times$10$^1$- 8.0$\times$10$^1$ propagules ml$\^$-1/ and 0-2.2$\times$10$^1$ propagules ml$\^$-1/ in April, August and October respectively. The surface water samples from the station 3 in August were added with feed stuffs for fish as much as 0.01 gl$\^$-1/, 0.1 gl$\^$-1/ and 1 gl$\^$-1/ and cultured at 5$\^{C}$, 15$\^{C}$, 25$\^{C}$ and 35$\^{C}$. Microbial cells were not isolated at all when the culturing temperature was 5$\^{C}$. However, the microbial cell number increased significantly in all the surface water samples containing 1 gl$\^$-1/ of the feed stuffs when cultured at 15$\^{C}$, 25$\^{C}$ and 35$\^{C}$

  • PDF

Clinical Outcomes of Thoracic Sympathicotomy for Palmar Hyperhidrosis (수부 다한증에서 흉부교감신경 절제술의 성적)

  • Lee, Jang-Hoon;Lee, Jung-Cheul
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.89-94
    • /
    • 2008
  • Background: Thoracoscopic R3 sympathicotomy can effectively treat palmar hyperhidrosis. Here, we evaluated post-operative outcomes of patients receiving a thoracoscopic R3 sympathicotomy due to palmar hyperhidrosis. Material and Method: From January 2001 to December 2006, 225 patients were treated with a R3 sympathicotomy, and follow up was completed for 200 patients, with an average follow up period of 51.7 ($11{\sim}80$) months. We measured postoperative hand sweating according to four grades; dry (grade 1), proper (grade 2), light sweating (grade 3), heavy sweating (grade 4) and evaluated patient satisfaction using 4 grades: very good (grade 0), good (grade1), regular (grade 2), and deficient (grade 3). Result: There were no differences in clinical parameters between the compensatory sweating group and the non-compensatory sweating group. There was a 83.5% compensatory sweating rate. The degree of compensatory sweating related to the patient's body mass index and was influenced by the season, environmental temperature, and emotional stress. Conclusion: The satisfaction rate was 61.5%, and the degree of satisfaction related to the development of compensatory sweating. Therefore, reducing compensatory sweating would increase patient satisfaction with R3 sympathicotomies.

MEASUREMENT OF ADHESION OF ROOT CANAL SEALER TO DENTINE AND GUTTA-PERCHA (상아질과 Gutta-Percha에 대한 근관충전용 Sealer의 결합강도의 측정)

  • Her, Mi-Ja;Yu, Mi-Kyung;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.89-99
    • /
    • 2003
  • The purpose of this study was to investigate the bonding of resin- based root canal sealer, AH26 when the sealer was applied as a thin layer between dentine and gutta-percha surface. In this study forty non-caries extracted human molars and resin-based root canal sealer(AH 26, DeTrey/Dentsply, Germany) were used. Disks of gutta-percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for thermoplastic obturation were used and dentin surfaces were treated with 2% NaOCl(Group 1) or 2%NaOCl+17% EDTA(Group 3). Disks of gutta-Percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for conventional obturation were used and dentin surface were treated with 2% NaOCl(Group 2) or 2%NaOCl+17% EDTA(Group 4). Enamel was removed by a horizontal section 1mm below the deepest portion of the central occlusal groove by using a watercooled low speed diamond saw. A second horizontal section was done around cementoenamel junction. Exposed dentin surface was cut to approximately $8{\times}8{\;}mm$ rectangular shape and was ground against 320, 400, 600 grade silicon carbide abrasive paper serially. After grinding, the dentine surface were soaked in a solution of 2% NaOCl for 30 minutes and twenty of specimens were treated with 17% EDTA solution for 1 minute. The treated specimens were washed and dried, Root canal sealer, AH26 was prepared according to the manufacture's instructions The Gutta-percha and dentin surface were coated with a thin layer of the freshly mixed seal or. The specimens were left overnight at room temperature. After their initial set, they were transferred to an incubator at $37$^{\circ}C$ for 72 h. After 72 hours, resin blocks were made. The resin block was serially sectioned vertically into stick of $1{\cdot}1mm$. Twenty sticks were prepared from each group. After that, tensile bond strength f3r each stick was measured with Microtensile Tester Failure patterns of the specimens at the interface between gutta-percha and dentin were observed under the SEM(x1000) and Stereomicroscope (LEICA M42O, Meyer Inst., TX U.S.A) at 1.25 x25 magnification. The results were statistically analysed by using a One-way ANOVA and Tukey's test. The results were as follows; 1. Tensile bond strengths($mean{\pm}SD$) were expressed with ascending order as follows: Group 1, $3.09{\pm}$ 1.05Mpa : Group 2, $6.23{\pm}1.16MPa$ : Group 3, $7.12{\pm}1.07MPa$ : Group 4, $10.32{\pm}2.06MPa$. 2. Tensile bond strengths of the group 2 and 4 used disks of gutta-percha for conventional obturation were significantly higher than that of the group 1 and 3 used fir thermoplastic obturation. (p < 0.05). 3. Tensile bond strengths of the group 3 and 4 treated with 2% NaOC1+17% EDTA were significantly higher than that of the group 1 and 2 treated with 2% NaOCl. (p < 0.05). 4. In analysis of failure patterns at the interface between sealer and gutta-percha, there were observed 49 (61%)cases of adhesive failure patterns and 31 (39%) cases of mixed failures patterns.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009 (설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo Young;Choi, Jong-Min;Baik, Yong-Kyu;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

Seed Germination, Seedling Grwoth and Optimal Seedling Density of Phellodendron amurense Rupr. in Nursery (황벽나무의 종자발아(種子發芽)와 묘목생장(苗木生長) 및 적정생육밀도(適正生育密度)에 관(關)한 연구(硏究))

  • Goo, Gwan-Hyo;Lee, Kang-Young;Youn, Ki-Sik;Lee, Chong-Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.4
    • /
    • pp.443-449
    • /
    • 1997
  • We examined the effect of pretreatments on seed germination, seedling growth, optimal seedling density of Phellodendron amurense. The seeds were carefully purified after collection in late Oct. from natural population at Mt. Chiri. For the evaluation of pretreatment effects, seeds were sowed in an experimental nursery after being stored in open ground($2{\sim}8^{\circ}C$) with soaking in 20% $H_2O_2$, 50-fold pon-pon solution, cold moist stratification in refrigerator($2{\sim}4^{\circ}C$) and dry storage in roam temperature($4{\sim}18^{\circ}C$), respectively, For the effect of growth density of seedlings, seedlings germinated in nursery were precisely controlled with 53, 104, 220, 380 seedlings per $m^2$. Among pretreatments for the promotion of germination rate, pon-pon treatment(68.8%) was highest, the others were higher than that in dry storage(2.3%), and these seed pretreatment methods were significantly different at 1% level. The height growth of seedlings showed the most vigor from Jun.12 to Jul. 8, and from Jul.20 to Aug. 2, and it reached to 72.8% of height growth. In case of 1-0 seedling, although seedling density per $m^2$ was increased, seedling growth was decreased. The optimal seedling density was 104 seedlings per $m^2$. The standard seedlings for plantation were above height 55cm, root collar diameter 8.1mm, and root length 21cm. These results demonstrated that seed of P. amurense requires stratification for the germination promotion.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Recent Progress in Air Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2007 (설비공학 분야의 최근 연구 동향 : 2007년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.844-861
    • /
    • 2008
  • The papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during the year of 2007 have been reviewed. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro nano fluid, micropump and fuel cell. Traditional CFD was still popular and widely used in research and development. Studies about fans and pumps were performed in the field of fluid machinery. Characteristics of flow and fin shape optimization are studied in the field of piping system. (2) The research works on heat transfer have been reviewed in the field of heat transfer characteristics, heat exchangers, and desiccant cooling systems. The research on heat transfer characteristics includes thermal transport in pulse tubes, high temperature superconductors, ground heat exchangers, fuel cell stacks and ice slurry systems. For the heat 'exchangers, the research on pin-tube heat exchanger, plate heat exchanger, condensers and gas coolers has been cordially implemented. The research works on heat transfer augmenting tubes have been also reported. For the desiccant cooling systems, the studies on the design and operating conditions for desiccant rotors as well as performance index are noticeable. (3) In the field of refrigeration, many papers were presented on the air conditioning system using CO2 as a refrigerant. The issues on the two-stage compression, the oil selection, and the appropriate oil charge were treated. The subjects of alternative refrigerants were also studied steadily. Hydrocarbons, DME and their mixtures were considered and various heat transfer correlations were proposed. (4) Research papers have been reviewed in the field of building facilities by grouping into the researches on heat and cold sources, air conditioning and air cleaning, ventilation and fire research including tunnel ventilation, flow control of piping system, and sound research with drain system. Main focuses have been addressed to the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies were mostly focused on analyzing the indoor environment in various spaces like cars, old tombs, machine rooms, and etc. in an architectural environmental field. Moreover, subjects of various fields such as the evaluation of noise, thermal environment, indoor air quality and development of energy analysis program were researched by various methods of survey, simulation, and field experiment.

Estimation of Wheat Growth using a Microwave Scatterometer (마이크로파 산란계를 이용한 밀 생육 추정)

  • Kim, Yihyun;Hong, Sukyoung;Lee, Kyungdo;Jang, Soyeong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.1
    • /
    • pp.23-31
    • /
    • 2013
  • Microwave remote sensing can help monitor the land surface water cycle and crop growth. This type of remote sensing has great potential over conventional remote sensing using the visible and infrared regions due to its all-weather day-and-night imaging capabilities. In this paper, a ground-based multi-frequency (L-, C-, and X-band) polarimetric scatterometer system capable of making observations every 10 min was developed. This system was used to monitor the wheat over an entire growth cycle. The polarimetric scatterometer components were installed inside an air-conditioned shelter to maintain constant temperature and humidity during the data acquisition period. Backscattering coefficients for the crop growing season were compared with biophysical measurements. Backscattering coefficients for all frequencies and polarizations increased until dat of year 137 and then decreased along with fresh weight, dry weight, plant height, and vegetation water content (VWC). The range of backscatter for X-band was lower than for L- and C-band. We examined the relationship between the backscattering coefficients of each band (frequency/polarization) and the various wheat growth parameters. The correlation between the different vegetation parameters and backscatter decreased with increasing frequency. L-band HH-polarization (L-HH) is best suited for the monitoring of fresh weight (r=0.98), dry weight (r=0.96), VWC (r=0.98), and plant height (r=0.96). The correlation coefficients were highest for L-band observations and lowest for X-band. Also, HH-polarization had the highest correlations among the polarization channels (HH, VV and HV). Based on the correlation analysis between backscattering coefficients in each band and wheat growth parameters, we developed prediction equations using the L-HH based on the observed relationships between L-HH and fresh weight, dry weight, VWC and plant height. The results of these analyses will be useful in determining the optimum microwave frequency and polarizations necessary for estimating vegetation parameters in the wheat.