• 제목/요약/키워드: Ground Station System

검색결과 397건 처리시간 0.037초

서울메트로 PSD장비 탄소접지모듈 설치 사례 (The example of the Carbon Grounding Modules installation for PSD systems at a subway station, Seoulmetro)

  • 정용기;현용섭;송병권;김용협
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.292-298
    • /
    • 2008
  • Seoul Metro and Seoul Metropolitan Rapid Transit Corp. have started installing screen doors at subway platforms to improve the environment of subways and prevent passengers' accidents since 2006. They are still installing screen doors at subway platforms and Metropolitan Rapid Transit Corporations in other areas are also proceeding with installment of screen doors or making preparations for it. Grounding is necessary for installing PSD systems. In case that PSD grounding is connected with existing electrical equipment grounding system, it was decided to install separate grounding for safe operation of PSD system and passenger safety. However, it's very difficult to install new grounding at the subway station compound. A way to improve this condition is that we proceed with grounding by composing grounding station by carbon grounding rod. This paper will mainly deal with how to design and construct carbon ground rod, which has been applied to PSD system grounding since 2006, including its experimental examples. In this paper, ways to secure ground resistance below 5 ohms, which is resistance necessary for PSD grounding, and to compose grounding system were also discussed. Furthermore, a ground test to check the ability to fulfill a role of PSD grounding system was conducted. As a result of applying carbon grounding module, PSD system is being operated without any problem and the installment of PSD system will be continuously expanded in the future. It's also thought that a way to integrate grounding of each functional room which has been installed at the subway station compound and to arrange equipotential grounding should be reviewed and performed promptly.

  • PDF

Performance Test for the SIGMA Communication System

  • Jeong, Seonyeong;Lee, Hyojeong;Lee, Seongwhan;Shin, Jehyuck;Lee, Jungkyu;Jin, Ho
    • Journal of Astronomy and Space Sciences
    • /
    • 제33권4호
    • /
    • pp.335-344
    • /
    • 2016
  • Scientific CubeSat with Instruments for Global Magnetic Fields and Radiations (SIGMA) is a 3-U size CubeSat that will be operated in low earth orbit (LEO). The SIGMA communication system uses a very high frequency (VHF) band for uplink and an ultra high frequency (UHF) band for downlink. Both frequencies belong to an amateur band. The ground station that communicates with SIGMA is located at Kyung Hee Astronomical Observatory (KHAO). For reliable communication, we carried out a laboratory (LAB) test and far-field tests between the CubeSat and a ground station. In the field test, we considered test parameters such as attenuation, antenna deployment, CubeSat body attitude, and Doppler frequency shift in transmitting commands and receiving data. In this paper, we present a communication performance test of SIGMA, a link budget analysis, and a field test process. We also compare the link budget with the field test results of transmitting commands and receiving data.

달 잡음에 의한 지상 시스템 수신 성능 열화 분석 (Analysis on Receiving Performance Degradation of Ground Station in Lunar Mission)

  • 박덕종;염경환
    • 한국전자파학회논문지
    • /
    • 제25권2호
    • /
    • pp.208-216
    • /
    • 2014
  • 달 탐사 미션 수행을 위한 지상국은 달 궤도선과 착륙선의 상태 정보 및 관측한 센서 데이터를 수신할 수 있어야 한다. 이러한 지상 시스템 개발 초기 단계에서는 정확한 링크 파라미터에 의한 링크 분석을 통해 지상 안테나의 크기 및 시스템 잡음 성능이 도출되어야 한다. 한편, 지상 안테나가 달 궤도선과 착륙선과 통신을 할 경우에 달을 지향하게 되고, 이 때 달은 자체 밝기에 의해 안테나의 수신 성능을 열화 시키는 잡음으로써 동작한다. 본 논문에서는 안테나가 달을 지향할 때 발생되는 수신 성능 열화에 대한 분석 결과를 제시한다. 결과 검증을 위해 달에 의한 안테나 잡음 온도를 우선 계산 한 후에 이를 본 논문에서 제안하는 시험 방식의 결과와 비교하였고, 그 결과는 허용 오차 수준에서 일치함을 확인하였다. 이는 달에 의한 안테나 잡음 온도의 계산 방식이 정당함을 검증한 것이므로 이 방식을 통하여 다양한 주파수와 안테나의 크기에 따른 달 탐사 지상 안테나의 수신 열화 분석을 수행할 수 있었다.

웨이포인트 기반 UAV 비행을 위한 Ground Control Station 구조 설계 연구 (Research on Structure Design of Ground Control Station for Waypoint based-UAV Flight)

  • 심규창;곽정훈;정영식;성연식
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2016년도 춘계학술발표대회
    • /
    • pp.675-678
    • /
    • 2016
  • 최근 무인항공기 (Unmanned Aerial Vehicel, UAV)는 장점인 빠른 이동속도와 장착된 카메라를 이용하여 넓은 지역을 감시하기 위해서 활용되고 있다. 하지만, 조종사가 UAV를 직접 조종하여 넓은 지역을 비행하기에는 많은 비용이 발생한다. UAV가 자율적으로 넓은 지역을 비행하는 방법이 요구된다. 이 논문은 웨이포인트를 기반으로 UAV를 비행시키기 위한 Ground Control Station (GCS)의 구조를 제안한다. 비행할 웨이포인트는 위성항법시스템(Global Positioning System, GPS) 기반으로 설정하고 제안한 구조를 기반으로 다양한 임무 수행을 위해 다수의 비행 알고리즘을 정의하여 UAV를 비행시킨다. 부가적으로, 웨이포인트 기반으로 UAV를 비행시키기 위한 사용자 인터페이스도 소개한다.

Development of CINEMA Mission Uplink Communication System

  • Yoon, Na-Young;Yoon, Se-Young;Kim, Yong-Ho;Yoon, Ji-Won;Jin, Ho;Seon, Jong-Ho;Chae, Kyu-Sung;Lee, Dong-Hun;Lin, Robert P.
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권1호
    • /
    • pp.33-40
    • /
    • 2012
  • Triplet Ionospheric Observatory (TRIO) CubeSatforIon, Neutral, Electron MAgneticfields (CINEMA) is a CubeSat with the weight 3 kg that will be operated in the orbit conditions of about 800 km altitude and $90^{\circ}$ inclination angle, using the S-band and ultra-high frequency (UHF)-band communication frequencies. Regarding the communication antenna loaded on the satellite, the two patch antennas has the downlink function in the S-band, whereas the two whip antennas has the function to receive the command sent by the ground station to the satellite in the UHF-band. The uplink ground station that communicates through the UHF-band with the CINEMA satellite was established at Kyung Hee University. The system is mainly composed of a terminal node controller, a transceiver, and a helical antenna. The gain of the helical antenna established at the Kyung Hee University ground station was 9.8 dBi. The output of the transceiver was set to be 5 W (6.9 dB) for the communication test. Through the far-field test of the established system, it was verified that the Roman characters, figures and symbols were converted into packets and transmitted to the satellite receiver in the communication speed of 9,600 bps.

발전소 직류전선로의 지락안전진단 시스템에 관한 연구 (A Study on the Ground Fault Diagnosis System of Power Station DC Power line)

  • 안영주;김남호;이형기
    • 한국안전학회지
    • /
    • 제12권1호
    • /
    • pp.37-43
    • /
    • 1997
  • There are two kinds of ground fault diagonosis system(GFD), which are for AC and DC power line. The ground fault current of a DC power line Is, first, analyzed for a description of a GFD system for DC power line and then the construction method of the GFD system, which could be processed and analyzed a ground fault current, are explained. Main functions of the system are that the detected ground fault current could be converted to the line insulation resistance by a program and saved in the system memory continuously. Finally a DC power line insulation safety could be decide by a change of the saved Insulation resistance for a given time. This system can detect the ground fault resistance to 100㏀.

  • PDF

COMS SYSTEM LEVEL RF COMPATIBILITY TEST SYNTHESIS

  • Lim, Hyun-Su;Park, Durk-Jong;Yang, Hyung-Mo;Ahn, Sang-Il
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.500-503
    • /
    • 2007
  • During the COMS system level test, the RF compatibility will be performed in order to verify that there is no issue in RF interface between satellite and COMS ground station, namely SOC (Satellite Operation Center) before the launch. As used for KOMPSAT1, the RF coaxial cable was chosen to be used to connect satellite and SOC with various advantages as compared with ground antennas. As the preparation step, RF cable and required multiplexer were tested in advance. This paper suggests the way for the RF compatibility tests between the satellite and the SOC over RF cable interface and presents the estimated level diagram as the signal power analysis result.

  • PDF

청송 양수발전소 시공사례 (A Case Study on the Chungsong Pumped-storage power station Construction)

  • 홍창수;이현구;도종열
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 추계 학술발표회
    • /
    • pp.169-178
    • /
    • 2006
  • The pumped-storage power system is the one of the hydroelectric power systems, generating electricity with hydraulic head difference. In this system, the electricity is produced during the hours of peak demand by using water that has been pumped into an upper reservoir from a lower reservoir during the hours of low demand. Generally, the system consists of an under-ground power house and tunnels such as the headrace, pressure, and tailrace tunnels. The Chungsong pumped-storage power station is the sixth one In the pumped-storage power station in Korea. Both the regional self-government and the population of chungsong -Goon had made a great effort to draw this power station construction into this area. The proposed Chungsong pumped-power station construction project was accepted by the central government as a part of the national electricity plan for the first time in Korea.

  • PDF

차세대 RNSS 감시국을 위한 고장 검출 알고리즘 개발 방안 (Development Approach of Fault Detection Algorithm for RNSS Monitoring Station)

  • 정다님;이수민;이찬희;김의호;최헌호
    • 한국항행학회논문지
    • /
    • 제28권1호
    • /
    • pp.1-14
    • /
    • 2024
  • 위치, 항법 및 시각정보 서비스를 제공하는 위성항법시스템은 위성시스템, 지상시스템, 사용자시스템으로 구성된다. 지상시스템의 구성요소인 감시국은 위성항법시스템의 서비스 제공 및 고장 검출을 위해, 위성항법 신호를 연속적으로 수집하고 위성의 SIS (signal-in-space) 고장과 수신기 및 다중반사파를 포함한 Local 고장과 같은 신호 이상을 검출하여 수신한 데이터와 검출 결과를 중앙처리국으로 전송하는 역할을 한다. 본 논문에서는 기존 위성항법시스템 감시국의 수신한 위성 신호에 대한 품질 판단 및 고장 검출을 위한 주요 모니터와 측정치 전처리 과정을 소개하고, 이를 활용하여 차세대 지역 위성항법시스템 (RNSS; regional navigation satellite system) 감시국의 구성요소와 아키텍처 및 알고리즘 개발 방안을 제시하였다.

Earthquake risk assessment of underground railway station by fragility analysis based on numerical simulation

  • Kwon, Sun Yong;Yoo, Mintaek;Hong, Seongwon
    • Geomechanics and Engineering
    • /
    • 제21권2호
    • /
    • pp.143-152
    • /
    • 2020
  • Korean society experienced successive earthquakes exceeding 5.0 magnitude in the past three years resulting in an increasing concern about earthquake stability of urban infrastructures. This study focuses on the significant aspects of earthquake risk assessment for the cut-and-cover underground railway station based on two-dimensional dynamic numerical analysis. Presented are features from a case study performed for the railway station in Seoul, South Korea. The PLAXIS2D was employed for numerical simulation and input of the earthquake ground motion was chosen from Pohang earthquake records (M5.4). The paper shows key aspects of earthquake risk for soil-structure system varying important parameters including embedded depth, supported ground information, and applied seismicity level, and then draws several meaningful conclusions from the analysis results such as seismic risk assessment.