• Title/Summary/Keyword: Ground Resistance

Search Result 1,049, Processing Time 0.026 seconds

Digital Adaptive Distance Relay for Transmission Line Protection (송전선로 보호용 디지털 지능형 거리계전기)

  • Jeong, Chang-Ho;Kim, Jin-O
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.9
    • /
    • pp.411-416
    • /
    • 2001
  • Distance relay is the most widely used in transmission line protection because it is applicable not only as main protection but also as back-up protection. However, the protection range of the distance relay is always fixed in the unchangeable operating range while the power system varies, and therefore the distance relay is the device that is the highly influenced by the power system changes. In this regard, this paper describes an approach to minimize the mal-operation of the distance relay due to the power system changes through changing protection range of the distance relay into optimal condition in response to the load variation and power system condition. Also mal-function of the distance repay in case of high resistance ground faults could be minimized through modeling the protection range into quadratic function.

  • PDF

The Specific Resistance Analysis and Measurement of the Ground at the site of the Anode Laying for the Electrolytic Protection for the Electrical Anticorrosive (전기방식용 양극 매설부지 대지 비저항 측정 및 분석)

  • Hong, Sung-Taek;Shin, Gang-Wook;Lee, Dong-Keun;Lee, Eun-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.115-117
    • /
    • 2005
  • The electrolytic protection is classified according to the current supplied. And there are the Sacrificial Anode System, the Impressed Current System, the Polarized Drainage System, the Forced Drainage System. This study is intended to design and analyze the electrolytic protection at water transmission pipes which is occurred the corrosion, and to show the methods protecting corrosions at water transmission pipes.

  • PDF

Seismic Response Analysis of Lightly Reinforced Concrete Shear Walls

  • Rhee, In-Kyu
    • International Journal of Railway
    • /
    • v.3 no.2
    • /
    • pp.73-82
    • /
    • 2010
  • Global and local behaviors of a lightly RC shear walls are investigated in this paper. For the sake of cyclic behaviors, nominal ground accelerations of 0.15 g, 0.40 g and 0.55 g which associated with natural periods of the walls are applied as listed in French CAMUS-2000 shake table test. Modified Kent & Park model, Drucker-Prager model for concrete material and $Giufr\acute{e}$-Menegotto-Pinto model for rebar are used for time history analyses using fiber/solids elements respectively. Alternatively, Eulerian beam analysis are discussed by imposing inelastic hinges at the most possible plastic hinge location using modified Takeda's trilinear model with stiffness reduction. Relative displacements, base shears, bending moments of 5-story shear building with 36-tons of mass under bi-lateral seismic excitation are extracted and compared with EC-8, PS-92 and KBC-09 provisions. Multi-scaled degradation process; material damage, elemental fracture and structural failure in turn is discussed in the view of numerical accuracy, efficiency and limitation depending on three different model-based analyses.

  • PDF

Effect of Blending Materials on the Durability of Concrete II. Freezing and Thawing Resistance of Concrete (염분환경하 콘크리트 경화체의 내구성에 미치는 혼합재의 영향 II. 콘크리트의 동결융해저항성)

  • Jaung, J.d.;Kim, W.K.;Jeong, Y.;Han, K.S.;Choi, S.H.
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1991.10a
    • /
    • pp.34-39
    • /
    • 1991
  • It is well-known that concretes under sea water environment show remarkably degrading phenomena physically by repeatable freeze-thawing action and chemically by penetration of soluted ions in sea water. In this study the influences of type of blending materials, their dosage and W/C ratio on freeze-thawing resistances of hardened cement concrete using foy ash, ground blast furnace slag, silica fume, EVA and SBR under sea-water environment were investigated.

  • PDF

Seismic response of buildings during the May 19, 2011 Simav, Turkey earthquake

  • Yon, Burak;Sayın, Erkut;Koksal, Teoman S.
    • Earthquakes and Structures
    • /
    • v.5 no.3
    • /
    • pp.343-357
    • /
    • 2013
  • On May 19, 2011 an earthquake struck Simav district of K$\ddot{u}$tahya which located west of Turkey. According to Disaster and Emergency Management Agency (DEMA), magnitude of this earthquake was $M_L$ = 5.7. In this earthquake 2 people lost their lives and considerably damages occurred in the city center and surrounding villages. Damaged structures in the earthquake area did not have adequate earthquake resistance since low quality materials, poor workmanship and improper selection of the structural system. In this study, reasons of damages and failure mechanism of reinforced concrete and masonry buildings were evaluated.

The direction and formation of carbonized conductive path according to surface leakage between electrodes (전극간 표면누설에 의한 탄화도전로의 생성과 방향성)

  • Shong, Kil-Mok;Han, Woon-Ki;Lee, Ki-Yoen;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1525-1526
    • /
    • 2006
  • Electrical current always travels through the minimum resistance path. In this paper, we are studied on the direction and formation of carbonized conductive path according to surface leakage between electrodes. The analysis of characteristics of the arc discharge as surface is broken down between exposed live parts. Using the HSIS(high speed imaging system, 100,000fps, redlake ltd., USA), it took photographs by arc growth mechanism occurred in on/off surge, ground fault and discharge between electrodes. Therefore, it recommended for results of technology development and application such as theoretic verification of an arc direction and economic security according to a technology about connecting arc generation in surfaces of insulators. Hereafter, it expected effects that application of energy utility technology through the arc control.

  • PDF

On-site Investigation of the Stray Current Condition in DC-Powered Subway System (지하철 직류 급전시스템의 표유전류 실태조사)

  • Ha, Yoon-Cheol;Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.373-375
    • /
    • 2003
  • The subway, a typical electrified transit, is operated by the 1500 V DC-powered system with the overhead positive feeder and the rails negative return. This return path would bring about considerable stray current circuits, that is, from the bottom of rails to sell and then to the station ground, unless the rail-to-soil resistance is sufficiently high. The stray current can cause electrolytic corrosion of subway metallic structures and adjacent underground utilities. In this paper, we reports on-site investigation of the stray current condition, especially influenced by drainage method. The drainage method including both forced drainage and polarized drainage, extensively adopted as a countermeasure for electrolytic corrosion of underground pipelines, was found out to exert a harmful influence upon rail components as well as the pipelines.

  • PDF

A Study on the Evaluation of Frost Damage of High-Flowing Concrete using Blast-Furnace Slag (고로슬래그미분말을 사용한 고유동콘크리트의 시공을 위한 내동해성의 평가)

  • 권영진
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.157-162
    • /
    • 2001
  • Recently, lots of studies for high flowing concrete have been suggested under practical use that it is only a way to solve the confronted problem. However, most studies have been concentrated on the manufacture method and properties of fresh concrete, but there is few studies for the durability of hardened concrete, specially for the freezing and thawing. Therefore this study is to investigate for the resistance of high-flowing concrete using finely ground granulated furnace blast slag to frost with experimental parameters, such as binder, ratio of replacement of granulated furnace blast slag, superplasticizer, curing method and blain surface area of granulated furnace blast slag.

  • PDF

Earth Ground Resistance by using Transfroming Tower's Corner Leakage Current (운전중인 철탑의 탑각 누설전류를 이용한 접지저항 측정 방법)

  • Lee, Sang-Oh;Kim, Hyun-Han;Gang, Jung-Ho;Ju, Deok-Yun;Lee, In-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.364-368
    • /
    • 2007
  • 현재 일반적으로 서지 발생장치를 이용하여 측정하는 서지임피던스 측정기는 측정시 측정의 경향성 및 재현성이 상당히 불량하여 측정값을 신뢰하기 힘들고 일반적인 접지저항 측정기로는 측정값이 정확하게 측정되지 않는 문제점이 있어 탑각의 누설전류를 이용한 활선철탑 접지저항 측정기에 의한 정확한 접지저항 측정을 하는 것에 이 연구의 목적이 있음

  • PDF

Structural redundancy of 3D RC frames under seismic excitations

  • Massumi, Ali;Mohammadi, Ramin
    • Structural Engineering and Mechanics
    • /
    • v.59 no.1
    • /
    • pp.15-36
    • /
    • 2016
  • The components of the seismic behavior factor of RC frames are expected to change as structural redundancy increases. Most researches indicate that increasing redundancy is desirable in response to stochastic events such as earthquake loading. The present paper investigated the effect of redundancy on a fixed plan for seismic behavior factor components and the nonlinear behavior of RC frames. The 3D RC moment resistant frames with equal lateral resistance were designed to examine the role of redundancy in earthquake-resistant design and to distinguish it from total overstrength capacity. The seismic behavior factor and dynamic behavior of structures under natural strong ground motions were numerically evaluated as the judging criteria for structural seismic behavior. The results indicate that increasing redundancy alone in a fixed plan cannot be defined as a criterion for improving the structural seismic behavior.