• Title/Summary/Keyword: Ground Firing Test

Search Result 63, Processing Time 0.026 seconds

Ground Firing Test Facility of Hybrid Rocket Engine (하이브리드로켓엔진 지상연소시험 설비)

  • Kim, Soo-Jong;Kim, Gi-Hun;Cho, Jung-Tae;Cho, Min-Kyoung;Do, Gyu-Sung;So, Jung-Soo;Heo, Jun-Young;Lee, Jung-Pyo;Park, Su-Hayng;Moon, Hee-Jang;Sung, Hong-Gye;Kim, Jin-Kon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.251-254
    • /
    • 2008
  • Ground firing test facility and test field for firing test of hybrid rocket engine were constructed. Ground firing test facility were composed of hybrid rocket engine, thrust stand, oxidizer storage/supply system, control system and data acquisition system. Firing tests of thrust 50 kgf class were conducted. Stable performance data was obtained and operational reliability of ground firing test facility were found.

  • PDF

Rocket Engine Test Facility Improvement for Hot Firing Test of 75 ton-f Class Gas Generator and Cold Flow Test (75톤급 가스발생기 연소시험을 위한 시험장 개선 및 수류시험)

  • Kang, Dong-Hyuk;Lim, Byoung-Jik;Ahn, Kyu-Bok;Seo, Seong-Hyeon;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.29-33
    • /
    • 2009
  • On the basis of the development experience of a gas generator for the 30 ton-f thrust liquid rocket engine combustor a Subscale Ground Firing Test Facility was designed and fabricated for a gas generator for the 75 ton-f thrust liquid rocket engine combustor. The Subscale Ground Firing Test Facility developed is going to be used to develop 75 ton-f class gas generator. Acquired data and test technique from this facility will be used to develope the high performance liquid rocket engine combustor and the Ground Firing Test Facility. This report describes the improved Subscale Ground Firing Test Facility for 75 ton-f class gas generator and results of the cold flow test.

  • PDF

Strain Characteristics of a 75 tonf-class Engine for Ground Firing Test (75톤급 엔진 지상 연소 시험 변형율 특성)

  • Yoo, Jaehan;Kim, Jinhyuk;Jeon, Seongmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.126-133
    • /
    • 2018
  • A liquid rocket engine experiences various static loads in flight, such as high pressures due to propellents, thrust and thermal loads due to cryogenic liquid oxygen and combustion gas with extreme vibration. During the engine development stage, structural analyses and investigation on the strain measured from ground firing tests are necessary for determining the structural reliability of the engine. In this study, the strain characteristics, obtained from the ground firing tests of a 75 tonf-class engine, were analyzed.

Performance Analysis and Configuration Design of the Thruster Nozzle for Ground-firing Test and Evaluation (지상연소시험평가용 추력기 노즐의 성능해석과 형상설계)

  • Kam, Ho-Dong;Kim, Jeong-Soo;Bae, Dae-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.2
    • /
    • pp.10-16
    • /
    • 2012
  • A computational analysis of nozzle flow characteristics and plume structure is conducted to examine performance of the supersonic nozzle employed in a thruster for ground firing test. At first, flow simulations in two-dimensional converging-diverging nozzle are performed for the verification of computational capability as well as turbulence model validity. Axisymmetric converging-diverging nozzles for ground firing test are analyzed with the k-${\omega}$ SST model. A performance penalty caused by flow separation in a diverging section is observed in initially-designed nozzle. The performance could be enhanced by the modification of the diverging section of nozzle contour.

Operation Techniques of Liquid Rocket Engine Combustor Ground Firing Test Facility (액체로켓엔진 연소기 지상연소시험설비 운영관리 기술)

  • Kang, Dong-Hyuk;Lim, Byoung-Jik;Moon, Il-Yoon;Seo, Seong-Hyeon;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.157-162
    • /
    • 2006
  • A Liquid Rocket Engine(LRE) ground firing test facility was built in Korea Aerospace Research Institute(KARI) in 2001 to develop the LRE for the first Korean liquid rocket, KSR-III. Around 170 tests were conducted since its establishment until recently by September 2006, and in the meantime, a considerable improvements were made in the capability. This paper describes the outline, conducted tests and operation techniques which have been accumulated through the operation of KARI LRE ground firing test facility.

  • PDF

Configuration Design, Hot-firing Test and Performance Evaluation of 200 N-Class GCH4/LOx Small Rocket Engine (Part II: Steady State-mode Ground Hot-firing Test) (200 N급 GCH4/LOx 소형로켓엔진의 형상설계와 성능시험평가 (Part II: 정상상태 지상연소시험))

  • Kim, Min Cheol;Kim, Young Jin;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.1
    • /
    • pp.9-16
    • /
    • 2020
  • A performance evaluation of the 200 N-class GCH4/LOx small rocket engine was performed through ground hot-firing test. As a result, the combustion pressure and thrust raised with the increase of the oxidizer supply pressure, and thus the specific impulse, characteristic velocity, and their efficiency increased. The characteristic velocity was measured at about 90% performance efficiency. The change of chamber aspect ratio did not affect the performance of the rocket engine in the test condition specified. In addition, uncertainty evaluation was conducted to ensure the reliability of the test results.

A Study on Vibration Phenomena occurred in Ground Firing Test of Solid Rocket Motors (고체추진 로켓모터의 지상연소시험시 발생되는 진동현상에 관한 연구)

  • 김준엽;장성조;김도영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2280-2285
    • /
    • 1993
  • Many items, as internal pressure, thrust, temperature, strain, etc. are measured in Ground Firing Test (GFT) of rocket motors. But these items are influenced by various phenomena occurred during propellant combustion. In this study, natural frequencies of motor itself and system(motor+loadcell) on Stand were measured. Also motor responses were measured during burning and analyzed so that the vibration characteristics occurred during GFT and the causes and characteristics of vibration signal appearing on thrust curve were identified.

A Construction Scheme of Control System in a Ground Hot-firing Test Facility (지상연소시험설비의 제어시스템 구축 방안)

  • Lee, Kwang-Jin;Kim, Ji-Hoon;Kim, Seung-Han;Han, Young-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.468-471
    • /
    • 2012
  • This paper describes a construction scheme of hot backup or triple modular redundancy control system in a ground hot-firing test facility to carry out performance assessment of propulsion system used in a space launch vehicle. It was possible for a hot backup redundancy control system with manual operated console to simulate TMR control system. A console layout of control system in control center to restrict imprudent works of operators was proposed.

  • PDF

Performance Analysis of the Supersonic Nozzle Employed in a Small Liquid-rocket Engine for Ground Firing Test (소형 액체로켓엔진 지상연소시험용 초음속 노즐의 성능해석)

  • Kam, Ho-Dong;Kim, Jeong-Soo;Bae, Dae-Seok;Lee, Jae-Won
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.321-324
    • /
    • 2011
  • A computational analysis of nozzle flow characteristics and plume structure using Reynolds-averaged Navier-Stokes equations with $k-{\omega}$ SST turbulence model was conducted to examine performance of the supersonic nozzle employed in a small liquid-rocket engine for ground firing test. Computed results and experimental outcome of 2-D converging-diverging nozzle flow were compared for verifying the computational capability as well as the turbulence model validity. Numerical computations of 2-D axisymmetric nozzle flow was carried out with the selected model. As a result, flow separation with backflow appeared around the nozzle exit. This investigation was reported as a background data for the optimal nozzle design of small liquid-propellant rocket engine for ground test.

  • PDF

Operation and Maintenance Techniques for Liquid Rocket Combustor Ground Firing Test Facility (액체로켓 연소기 지상연소시험설비 운영 및 관리 기술)

  • Kang, Dong-Hyuk;Lim, Byoung-Jik;Moon, Il-Yoon;Seo, Seong-Hyeon;Han, Yeoung-Min;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.3
    • /
    • pp.43-49
    • /
    • 2007
  • A ground firing test facility for Liquid Rocket Engine(LRE) combustor was built in Korea Aerospace Research Institute(KARI) in 2001 to support the development of the first Korean LRE for the KSR-III. About 170 tests were conducted up to date since its establishment and in the meantime a considerable improvements were made in the facility capability. This paper describes the outline, conducted tests and operation techniques which have been acquired through the operation of the test facility.