A Study on the method to collect Vehicle-Data using Wireless LAN (전동차운행정보수집을 위한 무선랜 활용방안 연구)

  • Ahn Tae-Ki;Lee Ho-Yong;Park Ki-Jun;Kim Gil-Dong
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1459-1461
    • /
    • 2004
  • EMU, Electrical Multiple Unit, stores various information in the computer system installed on the vehicle when train is running. The stored information has to be moved into a computer installed on the ground. The information is used to all kinds of planning concerned EMU, and taken advantage of maintenance with information importantly. IC memory card is used to move the information from vehicle to the ground at present. But this method has many weaknesses from hours and manpower aspect because it spends much time shifting data. So this paper proposes a method to move data as quickly and correctly as possible. We propose the method to collect the information using wireless LAN automatically in this paper. And we carried out data-transfer-test on the real field using wireless LAN to confirm possibility of this method. This paper shows the result of the data-transfer-test.

  • PDF

Proposal and Evaluation of Ground Response Spectrum Estimation Algorithm based on Seismic Observation Data (지진 관측데이터 기반 지반응답스펙트럼 추정 알고리즘 제안 및 평가)

  • Ahn, Jin-Hee;Jeong, Jin-Woo;Hong, Yu-Chan;Park, Jae-Bong;Choi, Hyoung-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.13-22
    • /
    • 2019
  • In order to evaluate the earthquake damage level of small and medium - sized bridges without earthquake monitoring system, we proposed an algorithm for estimating the seismic force at the target bridge location using the ground acceleration data from the earthquake observatories near the structure. In general, response spectrum analysis, which is the most widely used dynamic analysis method to design and evaluate the structural system numerically is required a response spectrum to determine the dynamic loading. In this study, selection methods of the three closest observatories from the target structure and estimation method of ground response spectrum at arbitrary locations are developed. The proposed method can consider the distance and phase between the target bridge and the seismic station and from the relationship between the acceleration amplitudes and the location of the selected seismic station, the earthquake loading of the target bridge can be determined. The proposed algorithm is estimated to be more conservative than the response spectrum evaluated by actual earthquake data.

Implementation of ZUPT on RPA Navigation System for GNSS Denied Ground Test

  • Shin, Hyeoncheol
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.9 no.2
    • /
    • pp.125-129
    • /
    • 2020
  • In this paper, Zero velocity UPdaTe (ZUPT) is implemented on the navigation system of Remotely Piloted Aircraft for GNSS denied environment. RPA's navigation system suffers from lack or loss of satellite signal while maintenance or ground test inside a hangar. Although some of the hangars install GPS repeaters for indoor tests, the anti-jamming equipment with array antenna blocks the repeater signal regarding them as hostile jamming signal. With ZUPT, an aircraft navigation system can be tested free from the divergence of navigation solution without line-of-sight satellites. The designed ZUPT aided centralized Kalman Filter is implemented on the Embedded GPS&INS and simulated with Captive Flight Test data. The simulation result shows stable navigation solution without GNSS updates.

The development of On-Line Cathodic Protection Monitoring System (지중 금속구조물의 전기방식 원격감시시스템 개발)

  • 임헌호;정성우;하희천
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.213-218
    • /
    • 2001
  • These days, corrosion condition of a underground objects is measured by the electric potential between the subject and ground. But this method is implemented by means of manual work with analog voltmeter, which is uneconomic and inefficient. So, We developed real-time On-Line cathodic protection monitoring system that is able to detect corrosion potential conditions of metal objects or various steel structures in the ground continuously, display them with the graphic screen, construct a database, and analyze them simultaneously. Since the data of corrosion and corrosion protection of all underground objects is processed automatically, not manually in this system, It is possible to reduce the manipulated error, and perform precise safety management, maintenance and inspection. As as result, this system can not only guarantee long-life operation, reduction of manpower and cost, but prevent large accidents in advance.

  • PDF

A Study for Applied In the Transfer of Train Information using RTD System (열차종합제어장치 정보전송시 RTD시스템을 적용한 사례 연구)

  • Shin, Han-Chul;Kim, Jung-Hyun;Kim, Sang-Hoon
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.01a
    • /
    • pp.109-110
    • /
    • 2011
  • Because contemporary rolling stock system is complex and highly advanced, and it builds mutual interface, it is necessary to manage maintenance of rolling stock systematically. This study present a case, which shows how to adopt and apply RTD(Remote Transmission Device) integrated to train information collection device. After the train service is complete and the train enters the main subway station, various kinds of information collected from TCMS(Train Control Monitoring System) is transmitted to train depot information collection device through RTD. This study suggests that RTD integrated to train information collection device helps build an effective rolling stock maintenance system by improving reliability of data transmission and cutting maintenance costs.

  • PDF

Study on performance improvement of electric-point machine monitoring system (전기선로전환기 모니터링시스템의 성능 향상에 관한 연구)

  • Park, Jae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4509-4514
    • /
    • 2010
  • In this thesis, the effect of switch maintenance improvement is confirmed after testing and operating the switch monitoring system that were researched and developed originally in order to improve method of electric switch maintenance. However, as in an automatic interlocking station where a ground crew was not placed, repair and inspection could not be carried out until the maintenance person comes in case of switch problems or maintenance. In order to improve this issue, control module was installed in a monitoring system which can communicate through a data radio to a remote computer. Thus, the monitoring device can receive control information which a remote computer commands during the operation of switches. Afterward, it shows information on the real-time status of swith, in particular, anomaly situation through user interface after the switch is operated. By improving performance of the monitoring system in this way which can be managed and controled at a remote place, the prompt countermeasure system in case of disruption will be built and as a result, efficiency and convenience of maintenance improvement will be expected to increase.

A Simulation Modeling for Rail Potential and Leakage Current Analysis in DC Traction System (직류 전기철도에서의 레일전위 및 누설전류 해석을 위한 시뮬레이션 모델링)

  • Yoon, Yim-Joong;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.196-201
    • /
    • 2008
  • In DC traction systems, a part of feedback current returning through rails becomes leakage current, illumination on a metal laid underground results from the leakage current to ground. To prevent the leakage current on rails, feedback rails almost have insulated with the ground. Insulation between rails and the ground causes that the earth method changes a isolated method in DC traction systems. the rail potential rise results in the isolated method. the rail potential rise causes an electric shock when a person touches the ground and rolling stock. To decrease the rail potential rise and leakage current, there are methods for reducing the feedback resistance and current of rails, increasing the leakage resistance, decreasing the distance between substations. But it are necessary to forecast and analyze the rail potential and amplitude of leakage current. In this paper, we modeled DC traction systems and feedback circuit to simulate the rail potential and amplitude of leakage current using PSCAD/EMTDC that is power analysis program, forecasted the rail potential and amplitude of leakage current about changing various parameters in the electric circuit. By using the simulation model, we easily will forecast the rail potential and amplitude of leakage current in case of a level of basic design and maintenance in electric railway systems, valuably use basic data in case of system selection.

  • PDF

Derivation of risk factors according to accident cases related to subway structures

  • Park, Hyun Chul;Park, Young Gon;Pyeon, Mu Wook;Kim, hyun ki;Yoon, Hee Taek
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.5
    • /
    • pp.329-341
    • /
    • 2021
  • This study derives the risk-Influence factors for subway structures, the basis for the transition from the current subway disaster recovery-oriented maintenance system to a preemptive disaster management system, to reduce risk factors for existing subway structures. To apply reasonable risk assessment techniques, risk influence factors for subway underground structures using statistical information(spatial information) and risk influence factors according to frequency of accidents were selected to derive the risk factors. The significant risk factors were verified through ground subsidence (SI: Subsidence Impact)-based correlation analysis. This process confirmed that the subsidence of the ground was a risk influence factor for the subway structure. The main result of this study is that derive the risk factors to improve the risk factors of subway structures due to the rapid increase in disaster risk factors. The derived risk factors that were expected to affect the depression around subway stations and track structures did not show a noticeable correlation, but the cause of this may be that there is no physical connection between them, but on the other hand, the accumulated data may not accurately record the surrounding depression. Accordingly, in order to evaluate the risk of depression around the station and track, more intensive observation and data accumulation around the structure are required.

Development of KTX Track Error Diagnosis Program using Track Circuit Modeling Methods (궤도회로 모델링을 이용한 KTX 궤도결함 진단 프로그램 개발)

  • Ahn, Dong-Jun;Lee, Byeong-Gon;Nam, Hyun-Do
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.44-51
    • /
    • 2012
  • The purpose of this study is development of the diagnosis system to preventative maintenance in the on-board measuring systems for in-cab electric inspection systems of high speed railway. The on-board measuring systems can inspect precisely whether ground signal system operate stably. In this paper, we recognize characteristics of the track circuits and confirm whether the wave of current matches the on-board measuring data through the electric modeling method for high speed railway. it is necessary to develop GUI visual programs that can simulate abnormalities of the on-board measuring data in many ways, and the visual program is designed to diagnosis in the case of track circuit equipment's function decreased in advance.

Preliminary Design of Monitoring and Control Subsystem for GNSS Ground Station (위성항법 지상국 감시제어시스템 예비설계)

  • Jeong, Seong-Kyun;Lee, Jae-Eun;Park, Han-Earl;Lee, Sang-Uk;Kim, Jae-Hoon
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.2
    • /
    • pp.227-238
    • /
    • 2008
  • GNSS (Global Navigation Satellite System) Ground Station monitors navigation satellite signal, analyzes navigation result, and uploads correction information to satellite. GNSS Ground Station is considered as a main object for constructing GNSS infra-structure and applied in various fields. ETRI (Electronics and Telecommunications Research Institute) is developing Monitoring and Control subsystem, which is subsystem of GNSS Ground Station. Monitoring and Control subsystem acquires GPS and Galileo satellite signal and provides signal monitoring data to GNSS control center. In this paper, the configurations of GNSS Ground Station and Monitoring and Control subsystem are introduced and the preliminary design of Monitoring and Control subsystem is performed. Monitoring and Control subsystem consists of data acquisition module, data formatting and archiving module, data error correction module, navigation solution determination module, independent quality monitoring module, and system operation and maintenance module. The design process uses UML (Unified Modeling Language) method which is a standard for developing software and consists of use-case modeling, domain design, software structure design, and user interface structure design. The preliminary design of Monitoring and Control subsystem enhances operation capability of GNSS Ground Station and is used as basic material for detail design of Monitoring and Control subsystem.