• Title/Summary/Keyword: Ground Coefficient

Search Result 971, Processing Time 0.026 seconds

The Potential Interference of the Grounding Grids (격자형 접지전극의 전위간섭)

  • Lee, Bok-Hee;Lee, Tae-Hyung;Lee, Su-Bong;Jung, Hyun-Uk;Gil, Hyoung-Jun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.261-263
    • /
    • 2005
  • This paper presents the potential interferences between various grounding electrodes. The ground potential rise and potential interference coefficient between grounding grid and ground rod were calculated. The potential rise and potential interference coefficient strongly depend on the distance between grounding electrodes.

  • PDF

Design of Coupled Resonators Bandpass Filter with Defected Ground Structure

  • Kim, Gi-Rae
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.2
    • /
    • pp.150-154
    • /
    • 2011
  • In this paper a four-pole elliptic function bandpass filter is designed with two ground slots. A research of microstrip bandpass filters (BPF) using defected ground structures (DGS) is presented. DGS technique allows designs of tight couplings without the necessity of using very narrow coupling gaps. The simulator Sonnet is used to design the resonator and to calculate the coupling coefficient of the basic coupling structure. Compared to similar microstrip filters without defected ground structure, the simulated performances of these novel structures indicate some technological advantages.

Performance Analysis of the Horizontal Ground Source Heat Pump for Greenhouse (시설원예용 수평형 지열 히트펌프 시스템의 성능분석)

  • Park, Yong-Jung;Kang, Shin-Hyung
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.447-452
    • /
    • 2007
  • Greenhouses should be heated during nights and cold days in order to fit growth conditions in greenhouses. Ground source heat pump(GSHP) or geothermal heat pump system(GHPs) is recognized to be outstanding heating and cooling system. Horizontal GSHP system is typically less expensive than vertical GSHP system but requires wide ground area to bury ground heat exchanger(GHE). In this study, a horizontal GSHP system with thermal storage tank was installed in greenhouse and investigated as performance characteristics. In the daytime, heating load of greenhouse is very small or needless because solar radiation increases inner air temperature. The results of study showed that the heating coefficient of performance of the heat pump ($COP_h$) was 2.9 and the overall heating coefficient of performance of the system($COP_{sys}$) was 2.4. Heating energy cost was saved 76% using the horizontal GSHP system with thermal storage tank.

  • PDF

Analysis of Split Power/Ground Plane Structures for Radiated EMI Reduction (EMI 저감을 위해 분할된 전원/접지 평판 구조에서의 방사성 방출 분석)

  • Lee, Jang-Hoon;Lee, Pil-Soo;Lee, Tae-Heon;Kim, Chang-Gyun;Song, In-Chae;Wee, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.6
    • /
    • pp.43-50
    • /
    • 2010
  • In this paper, we analyzed radiated emission generated by the split power/ground plane structures in order to reduce EMI in system modules. The magnetic fields and electric fields were simulated and measured on the test boards under various conditions. In order to reduce radiated emission, we have to determine spacing and location of the split ground gap so that input signal frequency does not coincide with the resonance frequency of the split power/ground plane structure and the phase of reflection coefficient is close to $0^{\circ}$ at input signal frequency. Moreover, we found that inserting a stitching capacitor could reduce the radiated emission. Low magnitude of reflection coefficient and the phase close to $0^{\circ}$ are required to reduce radiated emission. It is necessary to properly decide value and location of a stitching capacitor to fulfil those requirements.

Compact MIMO Antenna with Wide-Band Isolation and Ground Mode Resonance for Smart Glasses (그라운드 모드의 공진을 이용한 광대역 격리도를 가지는 스마트 안경용 소형 MIMO 안테나)

  • Ryu, Jongin;Kim, Hyeongdong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.10
    • /
    • pp.817-820
    • /
    • 2018
  • In this letter, a compact multiple-input multiple-output(MIMO) antenna design for a 2.4 GHz wireless local area network(WLAN) band is proposed for use in smart glasses. To miniaturize the MIMO antenna system, a ground plane is employed within the antenna and a T-shaped ground is proposed. To achieve wideband isolation, dual resonance is formed by the ground mode. One resonance is created by the T-shaped ground and the second resonance is created by adding a slot and a capacitor between the two feed lines. The measurements show that the reflection coefficient characteristic was less than -5.1 dB, whereas the isolation obtained was less than -20 dB. The diversity performance was evaluated using the measured two-dimensional radiation patterns, and the envelope correlation coefficient(ECC) values achieved in the target band(2.4~2.5 GHz) were less than 0.1.

Comparison of Coefficient of Consolidation and Prediction of Excess Pore Water Pressure of Agricultural Reservoir under Embankment on Soft Ground (연약지반상에 축조된 농업용저수지의 과잉공극수압 예측과 압밀계수의 비교)

  • Lee, Dal-Won;Kim, Eun-Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.2
    • /
    • pp.1-9
    • /
    • 2010
  • This study was carried out to comparison of coefficient of consolidation and the prediction of excess pore water pressure in agricultural reservoir on soft clay ground. For the purpose of verification of the proposed equation, laboratory model tests and field tests were performed and excess pore water pressure was compared to those predicted with the Terzaghi's method. The predicted excess pore water pressure according to ponding was very applicable to practice because it was close to the observed data. Also, for the comparison of coefficient of consolidation, the oedometer, constant rate of strain (CRS), and Rowe cell tests were performed. The coefficient of consolidation at the Rowe cell and CRS tests showed a greate increase than in the oedometer test. The ratio of the vertical and horizontal coefficient of consolidation showed a large difference according to various tests method and mixing ratio. Therefore, it is recommended that careful attention should be paid to predicting the required consolidation period in agricultural reservoir.

A Studyon the Movment of Ground Water of Banayweol Formation (반야월층(半夜月層)의 지하수운동(地下水運動)에 관(關)한 연구(硏究))

  • Kim, Yong Ki
    • Economic and Environmental Geology
    • /
    • v.9 no.4
    • /
    • pp.225-240
    • /
    • 1976
  • This study deals with the flow of bed rock ground water of Banyaweol Formation, which is presently cleared up as a laminar flow. The result obtained may be summarized as the following. 1) The Banyaweol Formation consists mainly of thin-bedded, green to blackish green shale, mudstone, and marl. The marl and mudstone alternatively occur with shale. The marl and mudstone form a aquifer of Banyaweol Formation. In this study, a group of aquifer is in convenience named as a aquifer zone. The aquifer occurs in lenticular form. The aquifer seems to be a type of artesian aquifer because it is covered with aquicludes, but it actually forms a unconfined aquifer because its piezometric surface stays under the lower aquiclude. The lowering of piezometric level is formed because of leakage of the ground water to the lower aquifer undersaturated. 2) The coefficient of permeability of Banyaweol Formation's ground water body (K) is derived by using Dupuit's equation as the following ${\log}K=\frac{CK^2-dK+f}{aK-b}\;\(M=1.365(2H-s)s\\M={\log}1.956s{\sqrt{H}}r\)$ here, $$a=\sum_{1}M_iG_i$$ $$b={\frac{1}{2}log{\sum_{i}}Q_i{^2}$$ $$c=2{\sum_{i}}M_i{^2}$$ $$d=loge{\sum_{i}}M_{i}Q_{i}+2{{\sum_{i}}N_{i}Q_{i}$$ $$f=loge{\sum_{i}}Q_i{^2}N_i$$ If the measured values substituted for the above equation, the coefficient of permeability of the aquifer is 4.1m/day. The coefficient of storge of the aquifer is $2.8{\times}10^{-4}$ if the measured values substituted for Theis's equation. Using the above constants, the filtration velocity of the aquifer is $2.1{\times}1O^{-1}m/day$and the daily flow quantity of the ground water is $847.38m^{3}/day$. 3) In order to understand the time necessary for a circulation of ground water body, the contents of tritum contained in the ground water are measured as 2.3 T.U. at the Korea Atomic Energy Research Institute. Before 1952, the average concentration of tritium per year in groundwater was reported as 10T. u., taking it as the standard, the groundwater of the present study 26.25 years old. Therofore, the groundwater of the Banyaweol Formation is judged as an relatively old groundwater. It is characteristic that the ground water of Banyawol Formation is laminar flow as well as unconfined aquifer and ground water flow of relatively long time. 4) The nature, means of flow, and circulation of Banyaweol Formation's ground water body make it possible set up this ground water body as a ground water system.

  • PDF

A case study on a tunnel back analysis to minimize the uncertainty of ground properties based on artificial neural network (인공신경망 기법에 근거한 지반물성치의 불확실성을 최소화하기 위한 터널 역해석 사례연구)

  • You, Kwang-Ho;Song, Won-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.1
    • /
    • pp.37-53
    • /
    • 2012
  • There is considerable uncertainty in ground properties used in tunnel designs. In this study, a back analysis was performed to find optimal ground properties based on the artificial neural network facility of MATLAB program of using tunnel monitoring data. Total 81 data were constructed by changing elastic modulus and coefficient of lateral pressure which have great influence on tunnel convergence. A sensitivity analysis was conducted to establish an optimal training model by varying the number of hidden layers, the number of nodes, learning rate, and momentum. Meanwhile, the optimal training model was selected by comparing MSE (Mean Squared Error) and coefficient of determination ($R^2$) and was used to find the correct elastic moduli of layers and the coefficient of lateral pressure. In future, it is expected that the suggested method of this study can be applied to determine the optimum tunnel support pattern under given ground conditions.

Ductility and inelastic deformation demands of structures

  • Benazouz, Cheikh;Moussa, Leblouba;Ali, Zerzour
    • Structural Engineering and Mechanics
    • /
    • v.42 no.5
    • /
    • pp.631-644
    • /
    • 2012
  • Current seismic codes require from the seismically designed structures to be capable to withstand inelastic deformation. Many studies dealt with the development of different inelastic spectra with the aim to simplify the evaluation of inelastic deformation and performance of structures. Recently, the concept of inelastic spectra has been adopted in the global scheme of the performance-based seismic design through capacity-spectrum methods. In this paper, the median of the ductility demand ratio for 80 ground motions are presented for different levels of normalized yield strength, defined as the yield strength coefficient divided by the peak ground acceleration (PGA). The influence of the post-to-preyield stiffness ratio on the ductility demand is investigated. For fixed levels of normalized yield strength, the median ductility versus period plots demonstrated that they are independent of the earthquake magnitude and epicentral distance. Determined by regression analysis of the data, two design equations have been developed; one for the ductility demand as function of period, post-to-preyield stiffness ratio, and normalized yield strength, and the other for the inelastic deformation as function of period and peak ground acceleration valid for periods longer than 0.6 seconds. The equations are useful in estimating the ductility and inelastic deformation demands for structures in the preliminary design. It was found that the post-to-preyield stiffness has a negligible effect on the ductility factor if the yield strength coefficient is greater than the PGA of the design ground motion normalized by gravity.

Mathematical Models Predicting for Tree Skidding Forces and Its Evaluations (집재견인력 예측을 위한 수학적 모델의 개발과 평가)

  • Oh, Jae-Heun;Hwang, Jin Sung;Cha, Du Song
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.4
    • /
    • pp.448-454
    • /
    • 2007
  • Mathematical models for predicting the ground and semi-ground skidding force have been developed. The skidding force is expressed as a function of log geometry, total weight and coefficient of skidding. The coefficient of skidding was determined under field tests. The validity of the model developed was examined by comparing the predicted and measured skidding forces. Calculated ground skidding force, using the model developed can be predicted well with that measured experimentally. The semi-ground skidding force calculated from the model, however, does not predict well due to its confined conditions experimentally.