• Title/Summary/Keyword: Grid-based control

Search Result 684, Processing Time 0.026 seconds

Monitoring and Control System for Efficient Operating and Management of Photovoltaic Power Generation System (태양광발전시스템의 효율적 운용과 관리를 위한 모니터링 및 제어 시스템)

  • Bin, Jae-Gu;Kang, Feel-Soon;Kim, Cheul-U
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.3
    • /
    • pp.532-539
    • /
    • 2007
  • Photovoltaic power generation system is one of new renewable energy sources. Such distributed power generation system has important issues for the system management ad operating after its installation. To solve the problem, remote monitoring and control systems can be employed. In this paper, LabVBEW based monitoring and control system is proposed for efficient management and operation of the photovoltaic power generation system. Interface method between monitoring part and DSP controller is given in detail. The proposed system is verified through experiments using a grid-connected photovoltaic power generation system.

A Study on Non-western modernity of Surface Phenomena in Korean Commercial Architecture (한국 상업건축 입면현상의 비서구적 근대성에 대한 연구)

  • Lee, Sang-Hun
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.6
    • /
    • pp.218-227
    • /
    • 2011
  • Korean commercial architecture is based on two distinctive characteristics of western modern architecture: grid frame structure and free facade. However, the original facade of the building disappears as numbers of commercial advertisements and signboards representing inner programs cover up the original facade. This is a unique feature of commercial architecture in Korea which I would call the surface phenomena of Korean commercial architecture. Common criticism on this type of building is that too many and too big signboards infringe upon the original pure facade of the architecture. Underlying assumption here is that signboards and commercial ads are inessential and decorative elements simply attached to the original pure facade of modern architecture. However, in this paper, I argue that commercial decorations is an essential aspect of korean commercial architecture rather than an inessential decorative element attached later to the essential facade of architecture and that it reflects the historical specificity of cultural and architectural modernity of Korea And thus, the surface phenomena of Korean commercial architecture should not be judged based upon the aesthetic paradigms of either western modern or postmodern architecture. Rather, it can be argued that surface phenomena of Korean commercial architecture is a reflection of a modernity beyond the paradigm of western modernism and postmodernism. The agenda of Korean commercial architecture is then not simply to restrict or to control signboards on the building facades with the intention to clean up facade of the building but rather to integrate the signs and commercial ads with the structure of architectural surface.

EV Flexibility Availability for V2G Considering ISO/IEC 15118 Charging Protocol (ISO/IEC 15118기반 V2G 환경에서 전기자동차 유연성 검토)

  • Lee, Sang-Hwan;Cho, Kyu-Sang;Lee, Sang-Young;Kim, Young-Woo;Son, Sung-Yong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.1
    • /
    • pp.91-97
    • /
    • 2021
  • ISO/IEC 15118 is an international communication standard for EV(electric vehicle)'s V2G implementation. In the charging/discharging control of an EV based on a communication protocol, there is inevitably a time delay when charging/discharging occurs, and the delay may limit in supplying power flexibility. In this paper, we implemented an ISO/IEC 15118-based V2G emulator and measured the charge/discharge response characteristics. As a result, the time delay appeared as 0.12ms. Accordingly, the power flexibility markets that EV can participate in under the current standard were explored.

Efficient Opaque Ice Sphere Formation Using a Lightweight Geometric Approach

  • Jong-Hyun Kim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.3
    • /
    • pp.91-98
    • /
    • 2024
  • In this paper, we present a particle-grid blending framework based on a geometric approach to efficiently represent opaque ice spheres with air bubbles. The water temperature is diffused through the grid and the air bubbles represented inside the ice through the particles. To solve the problem of previous methods that generate noisy dissolved air fields, we use levelsets to lighten the algorithm, i.e., the number of active particles and the initial amount of dissolved oxygen can be used to efficiently control the termination conditions of heat diffusion. We also extend the previous dissolved air field method, which only computes near air bubbles, to transparent regions to represent realistic ice spheres, and introduce a levelset-based approach to accurately compute the orientation of particles. As a result, the method presented in this paper is about three times faster than the existing methods and shows visually improved visualization of opaque ice spheres, which can be used in the field of representing physical virtual ice forms.

A Proposal of USN-based DER(Decentralized Energy Resources) Management System (USN 기반의 댁내 분산 전력 관리 시스템 제안)

  • Kim, Bo-Min;Kim, Jeong-Young;Bang, Hyun-Jin;Jang, Min-Seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.871-874
    • /
    • 2010
  • Needs for Smart Grid development are increasing all over the world as a solution to its problem according to depletion of energy resources, climatic and environmental rapidly change and growing demand for electrical power. Especially decentralized power is attracting world's attention. In this mood a new era for a unit scale of decentralized power environment is on its way in building. However there is a problem to have to be solved in the uniformity of power quality because the amount of power generated from renewable energy resources such as wind power and solar light is very sensitive to climate fluctuation. And thus this paper tries to suggest an energy management method on basis of real time monitoring for meteorological data. In the current situation of lacking in USN-based killer application in Smart Grid field, this paper proposes the USN-based DER management system which collects the meteorological data and control power system througout utilizing wireless sensor network technique this business. This communication technique is regarded to be efficient in aspects of installation cost and tits maintenance cost. The proposed EMS model embodies the method for predicting the power generation by monitoring and analyzing the climatic data and controling the efficient power distribution between the renewable energy and the existing power. The ultimate goal of this paper is to provide the technological basis for achieving zero-energy house.

  • PDF

Power Smoothening Control of Wind Farms Based on Inertial Effect of Wind Turbine Systems

  • Nguyen, Thanh Hai;Lee, Dong-Choon;Kang, Jong-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.1096-1103
    • /
    • 2014
  • This paper proposes a novel strategy for attenuating the output power fluctuation of the wind farm (WF) in a range of tens of seconds delivered to the grid, where the kinetic energy caused by the large inertia of the wind turbine systems is utilized. A control scheme of the two-level structure is applied to control the wind farm, which consists of a supervisory control of the wind farm and individual wind turbine controls. The supervisory control generates the output power reference of the wind farm, which is filtered out from the available power extracted from the wind by a low-pass filter (LPF). A lead-lag compensator is used for compensating for the phase delay of the output power reference compared with the available power. By this control strategy, when the reference power is lower than the maximum available power, some of individual wind turbines are operated in the storing mode of the kinetic energy by increasing the turbine speeds. Then, these individual wind turbines release the kinetic power by reducing the turbine speed, when the power command is higher than the available power. In addition, the pitch angle control systems of the wind turbines are also employed to limit the turbine speed not higher than the limitation value during the storing mode of kinetic energy. For coordinating the de-rated operation of the WT and the storing or releasing modes of the kinetic energy, the output power fluctuations are reduced by about 20%. The PSCAD/EMTDC simulations have been carried out for a 10-MW wind farm equipped with the permanent-magnet synchronous generator (PMSG) to verify the validity of the proposed method.

A Study on Power Factor Control of Inverter-based DG System with Considering the Capacity of an Active Harmonic Filter and an Inverter (고조파 필터 및 인버터의 용량을 고려한 분산전원 시스템의 역률 제어에 관한 연구)

  • Kim, Young-Jin;Hwang, Pyeong-Ik;Moon, Seung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2149-2154
    • /
    • 2009
  • Electric power quality in power transmission/distribution systems has considerably been deteriorated with the increase in the capacity of distributed generators (DGs). It is because inverters, connecting DGs to conventional power grids, tend to generate harmonic current and voltage. For harmonic mitigation, a large amount of research has been done on passive and active filters, which have been operating successfully in many countries. This paper, therefore, presents how to adopt the filters to an inverter-based DG, with considering a system consisting of both inverter-based DG and harmonic filters. In particular, this paper describes the simulation results using the PSCAD/EMTDC: firstly, the relationship between total harmonic distortion(THD) of current and output power of DG: secondly, the harmonic mitigation ability of passive and active filters. The system, furthermore, is obliged to satisfy the regulations made by Korean Electric Power Corporation(KEPCO). In the regulations, power factor should be maintained between 0.9 and 1 in a grid-connected mode. Thus, this paper suggests two methods for the system to control its power factor. First, the inverter of DG should control power factor rather than an active filter because it brings dramatic decrease in the capacity of the active filter. Second, DG should absorb reactive power only in the range of low output power in order to prevent useless capacity increase of the inverter. This method is expected to result in the variable power factor of the system according to its output power.

A Magnetic Energy Recovery Switch Based Terminal Voltage Regulator for the Three-Phase Self-Excited Induction Generators in Renewable Energy Systems

  • Wei, Yewen;Kang, Longyun;Huang, Zhizhen;Li, Zhen;Cheng, Miao miao
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1305-1317
    • /
    • 2015
  • Distributed generation systems (DGSs) have been getting more and more attention in terms of renewable energy use and new generation technologies in the past decades. The self-excited induction generator (SEIG) occupies an important role in the area of energy conversion due to its low cost, robustness and simple control. Unlike synchronous generators, the SEIG has to absorb capacitive reactive power from the outer device aiming to stabilize the terminal voltage at load changes. This paper presents a novel static VAR compensator (SVC) called a magnetic energy recovery switch (MERS) to serve as a voltage controller in SEIG powered DGSs. In addition, many small scale SEIGs, instead of a single large one, are applied and devoted to promote the generation efficiency. To begin with, an expandable mathematic model based on a d-q equivalent circuit is created for parallel SEIGs. The control method of the MERS is further improved with the objective of broadening its operating range and restraining current harmonics by parameter optimization. A hybrid control strategy is developed by taking both of the stand-alone and grid-connected modes into consideration. Then simulation and experiments are carried out in the case of single and double SEIG(s) generation. Finally, the measurement results verify that the proposed DGS with SVC-MERS achieves a better stability and higher feasibility. The major advantages of the mentioned variable reactive power supplier, when compared to the STATCOM, include the adoption of a small DC capacitor, line frequency switching, simple control and less loss.

Application of Conservation Voltage Reduction using Automatic Voltage Regulator of Linear Voltage Control in Campus Microgrid with Power Consumption Reduction (에너지 절감을 고려한 캠퍼스 마이크로그리드에서 선형 전압제어 방식의 AVR을 이용한 CVR의 적용)

  • Lim, Il-Hyung;Lee, Myung-Hwan;Shin, Yong-Hark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1039-1046
    • /
    • 2017
  • Campus microgrid is designed and built by considering not only power generation but also power consumption management as connected microgrid type because the main goal of the campus microgrid is to save power consumption costs. There are many functions to achieve the goal and they are mainly to use generation-based functions such as islanding operation for peak management and for emergency events. In power distribution operation, Conservation Voltage Reduction (CVR) is applied in order to reduce power consumption. The CVR is defined as a function for load consumption reduction by voltage reduction in order to reduce peak demands and energy consumption. However, application of CVR to microgrid is difficult because the microgrid cannot control a tap of transformer in a substation and the microgrid normally is not designed with phase modifying equipment like a step-voltage-regulator which can control voltage in power distribution system operation. In addition, an impact of the CVR is depended on load characteristics such as a normal load, a rated power, and synchronous motors. Therefore, this paper proposes an application of CVR using linear voltage control based AVR in campus microgrid with power consumption reduction considering characteristics of load and component in the microgrid. The proposed system can be applied to each buildings by a configuration of power distribution cables; and the application results and CVR factor are presented in this paper.

The Discipline of the Dom-ino Frame and the Regulating Line - A Study of Le Corbusier's Villa La Roche-Jeanneret and Villa Stein-de Monzie - (르 꼬르뷔제 건축에서 돔-이노 프레임과 규준선의 기율 - 라 로쉬-잔느레 주택과 가르쉬 주택을 중심으로 -)

  • Pai, Hyung-Min;Hyun, Myung-Seok
    • Journal of architectural history
    • /
    • v.12 no.1 s.33
    • /
    • pp.25-41
    • /
    • 2003
  • This paper is a study of Le Corbusier's trace regulateur of the 1920s, particularly its role in the design of the Villas La Roche-Jeanneret and Stein-de Monzie. It proceeds on the basis of the following three themes: first, the relation between the regulating line and the dom-ino frame; second, its status as a proportional device based not on a module system but one that defines relations; third, its function as an essential practical device in the design process. In the Villa La Roche-Jeanneret, the embedded horizontal planes of the dom-ino frame were constant, but the vortical lines of the columns were altered according to the changes in plan. Initially, a left-hand bay window formed a symmetry with the right-hand bay window, the only constant in the design process. With subsequent changes, mullion sections of the horizontal window and roof elements came to provide the reference points for the regulating line. Eventually, a regulating line different from the one that controlled the bay window and the elongated volume came to control the entrance hall of Villa La Roche, resulting in three different kinds of regulating lines in the final version. In contrast to the Villa La Roche-Jeanneret, a singular and consistent regulation line was anticipated in the earliest design stages of the Villa Stein-de Monzie. The repetition of its A:B grid and the standard $2.5m{\times}1.0m$ sliding window determined the proportions of both its plan and elevation, and thus the regulating line became 'automatic,' losing its viability as a practical tool. Though the regulating titles of the La Roche-Jeanneret look as if they were an afterthought, drawn after the design was complete, they were most active, requiring tenacity and discipline in their application. On the other hand, the seemingly 'redundant' regulating line of the Villa Stein-de Monzie gains its raison d'etre from the dom-ino frame. Its cantilevers and uninterrupted horizontal window could be used in decisive fashion because of the guarantee that the correct proportion would always be maintained. Thus we discover that Le Corbusier's discipline of the 1920s had a certain spectrum of flexibility. His 'parti' ranged from the extremely loose and malleable grid of the Villa La Roche-Jeanneret to the fixed grid of the Villa Stein-de Monzie. In different ways, these projects retain the tension between the dom-ino frame and the regulating line. For Le Corbusier, as much as the grid was an object with fixed attributes, it was also an active medium manipulated by the will of the architect.

  • PDF