• 제목/요약/키워드: Grid-based control

검색결과 684건 처리시간 0.025초

평균기온과 식생의 영향을 고려한 격자기반 일 지표토양온도 예측 모형 개발 (Development of a Grid-Based Daily Land Surface Temperature Prediction Model considering the Effect of Mean Air Temperature and Vegetation)

  • 최치현;최대규;최현일;김경현;김상단
    • 한국물환경학회지
    • /
    • 제28권1호
    • /
    • pp.137-147
    • /
    • 2012
  • Land surface temperature in ecohydrology is a variable that links surface structure to soil processes and yet its spatial prediction across landscapes with variable surface structure is poorly understood. And there are an insufficient number of soil temperature monitoring stations. In this study, a grid-based land surface temperature prediction model is proposed. Target sites are Andong and Namgang dam region. The proposed model is run in the following way. At first, geo-referenced site specific air temperatures are estimated using a kriging technique from data collected from 60 point weather stations. Then surface soil temperature is computed from the estimated geo-referenced site-specific air temperature and normalized difference vegetation index. After the model is calibrated with data collected from observed remote-sensed soil temperature, a soil temperature map is prepared based on the predictions of the model for each geo-referenced site. The daily and monthly simulated soil temperature shows that the proposed model is useful for reproducing observed soil temperature. Soil temperatures at 30 and 50 cm of soil depth are also well simulated.

리튬이온전지를 이용한 태양광전원의 운용효율향상장치의 제어 알고리즘에 관한 연구 (A Study on Control Algorithms of Efficiency Improvement Device for PV System Operation using Li-ion Battery)

  • 박지현;김병목;이후동;남양현;노대석
    • 한국산학기술학회논문지
    • /
    • 제19권10호
    • /
    • pp.590-597
    • /
    • 2018
  • 최근 전 세계적으로 에너지 고갈과 기후변화 문제로 인하여, 재생 가능하고 친환경적인 태양광전원에 대한 관심이 증가되고 있다. 그러나, 이러한 태양광전원은 주변 환경에 따라 출력이 크게 변동되는데, 일부 모듈에만 음영이 발생하여도 태양광전원의 전체적인 운용 효율이 상당히 저하되는 문제점을 가지고 있다. 즉, 기존의 제어방식에서는 모듈을 직렬로 연결된 스트링들이 인버터에 연계되어 있으므로, 일부 모듈에 부분 음영이 발생하면 해당 스트링의 전압이 인버터의 동작전압범위를 벗어나게 되어, 해당 스트링이 인버터에서 탈락되는 문제점이 발생할 수 있다. 따라서, 본 논문에서는 음영에 의하여 태양광 스트링이 인버터에서 탈락되는 것을 방지하기 위하여, 태양광스트링에 리튬이온전지를 연결한 태양광전원 운용효율 향상장치의 제어알고리즘을 제안한다. 또한, 전력전자 회로해석 상용 프로그램인 PSIM S/W를 이용하여 태양광스트링, 리튬이온전지, 계통연계형 인버터로 구성된 태양광전원의 운용효율향상장치의 모델링을 수행하여 운용 특성을 분석한 결과, 직렬로 연결된 리튬이온전지가 부분 음영에 의하여 전압 저하를 발생한 해당 스트링의 전압을 보상함으로서, 해당 스트링이 인버터에서 탈락되는 현상을 개선하여 태양광전원의 운용효율을 향상시킬 수 있음을 알 수 있었다.

Dynamic Droop-based Inertial Control of a Wind Power Plant

  • Hwang, Min;Chun, Yeong-Han;Park, Jung-Wook;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1363-1369
    • /
    • 2015
  • The frequency of a power system should be maintained within the allowed limits for stable operation. When a disturbance such as generator tripping occurs in a power system, the frequency is recovered to the nominal value through the inertial, primary, and secondary responses of the operating synchronous generators (SGs). However, for a power system with high wind penetration, the system inertia will decrease significantly because wind generators (WGs) are operating decoupled from the power system. This paper proposes a dynamic droop-based inertial control for a WG. The proposed inertial control determines the dynamic droop depending on the rate of change of frequency (ROCOF). At the initial period of a disturbance, where the ROCOF is large, the droop is set to be small to release a large amount of the kinetic energy (KE) and thus the frequency nadir can be increased significantly. However, as times goes on, the ROCOF will decrease and thus the droop is set to be large to prevent over-deceleration of the rotor speed of a WG. The performance of the proposed inertial control was investigated in a model system, which includes a 200 MW wind power plant (WPP) and five SGs using an EMTP-RV simulator. The test results indicate that the proposed scheme improves the frequency nadir significantly by releasing a large amount of the KE during the initial period of a disturbance.

Optimal Power Control Strategy for Wind Farm with Energy Storage System

  • Nguyen, Cong-Long;Lee, Hong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.726-737
    • /
    • 2017
  • The use of energy storage systems (ESSs) has become a feasible solution to solve the wind power intermittency issue. However, the use of ESSs increases the system cost significantly. In this paper, an optimal power flow control scheme to minimize the ESS capacity is proposed by using the zero-phase delay low-pass filter which can eliminate the phase delay between the dispatch power and the wind power. In addition, the filter time constant is optimized at the beginning of each dispatching interval to ensure the fluctuation mitigation requirement imposed by the grid code with a minimal ESS capacity. And also, a short-term power dispatch control algorithm is developed suitable for the proposed power dispatch based on the zero-phase delay low-pass filter with the predetermined ESS capacity. In order to verify the effectiveness of the proposed power management approach, case studies are carried out by using a 3-MW wind turbine with real wind speed data measured on Jeju Island.

Power Distribution Control Scheme for a Three-phase Interleaved DC/DC Converter in the Charging and Discharging Processes of a Battery Energy Storage System

  • Xie, Bing;Wang, Jianze;Jin, Yu;Ji, Yanchao;Ma, Chong
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1211-1222
    • /
    • 2018
  • This study presents a power distribution control scheme for a three-phase interleaved parallel DC/DC converter in a battery energy storage system. To extend battery life and increase the power equalization rate, a control method based on the nth order of the state of charge (SoC) is proposed for the charging and discharging processes. In the discharging process, the battery sets with high SoC deliver more power, whereas those with low SoC deliver less power. Therefore, the SoC between each battery set gradually decreases. However, in the two-stage charging process, the battery sets with high SoC absorb less power, and thus, a power correction algorithm is proposed to prevent the power of each particular battery set from exceeding its rated power. In the simulation performed with MATLAB/Simulink, results show that the proposed scheme can rapidly and effectively control the power distribution of the battery sets in the charging and discharging processes.

지능형 LED 조명 시스템의 신뢰성 확보를 위한 유무선 이중망 통합 인터페이스 구현 (Implementation of Integrated Interface based on Wire and Wireless Dual Network for Ensuring the Reliability of Intelligent LED Lighting System)

  • 이운선;박태진;박만곤
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.306-312
    • /
    • 2014
  • The ZigBee communication method, which is the most frequently applied to the LED lighting control system, has drawbacks of low-speed and low-capacity, and the communication failure possibility due to environmental influences is on the rise. Therefore, it is important to secure the communication reliability by applying an integrated interface with a wire-wireless dual-network. This paper developed a communication module, which has a platform converging and combining the ZigBee of USN environments with the PLC of power line communication environments, to implement a dualized communication interface system supporting the wire-wireless integrated protocol, and implemented a wire-wireless networking device and a control system software technology. As a result, it was automatically switched into the PLC communication within 4.4 seconds on average when there was an access failure in the ZigBee communication network, so a reliable communication network was built.

Multi-dimensional seismic response control of offshore platform structures with viscoelastic dampers (II-Experimental study)

  • He, Xiao-Yu;Zhao, Tie-Wei;Li, Hong-Nan;Zhang, Jun
    • Structural Monitoring and Maintenance
    • /
    • 제3권2호
    • /
    • pp.175-194
    • /
    • 2016
  • Based on the change of traditional viscoelastic damper structure, a brand-new damper is designed to control simultaneously the translational vibration and the rotational vibration for platforms. Experimental study has been carried out on the mechanical properties of viscoelastic material and on its multi-dimensional seismic response control effect of viscoelastic damper. Three types of viscoelastic dampers with different shapes of viscoelastic material are designed to test the influence of excited frequency, strain amplitude and ambient temperature on the mechanical property parameters such as circular dissipation per unit, equivalent stiffness, loss factor and storage shear modulus. Then, shaking table tests are done on a group of single-storey platform systems containing one symmetric platform and three asymmetric platforms with different eccentric forms. Experimental results show that the simulation precision of the restoring force model is rather good for the shear deformation of viscoelastic damper and is also satisfied for the torsion deformation and combined deformations of viscoelastic damper. The shaking table tests have verified that the new-type viscoelastic damper is capable of mitigating the multi-dimensional seismic response of offshore platform.

Active Frequency Drift Method for Islanding Detection Applied to Micro-inverter with Uncontrollable Reactive Power

  • Kwak, Raeho;Lee, June-Hee;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1918-1927
    • /
    • 2016
  • This paper proposes active frequency drift (AFD) as an anti-islanding method applied to micro-inverters with uncontrollable reactive power. When using ordinary inverter topologies, such as full bridge inverters in photovoltaic systems, the islanding phenomenon can be detected with reactive power-based methods, such as reactive power variation. However, when the inverter topology cannot control the reactive power, conventional anti-islanding methods with reactive power cannot be utilized. In this work, the topology used in this paper cannot control the reactive power. Thus, an anti-islanding method that can be used in topologies that cannot control the reactive power is proposed. The conventional anti-islanding method of the topology that cannot control reactive power is introduced and analyzed. Unlike the conventional AFD method, the proposed method extends a zero current interval every predetermined cycle. The proposed method offers certain advantages over conventional AFD methods, such as total harmonic distortion. The proposed method is validated through simulation and experiment.

유계상수 추정과 동적인 퍼지 규칙 삽입을 이용한 비선형 계통에 대한 강인한 적응 퍼지 제어기 설계 (Design of Robust Adaptive Fuzzy Controller for Uncertain Nonlinear System Using Estimation of Bounding Constans and Dynamic Fuzzy Rule Insertion)

  • 박장현;박귀태
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제50권1호
    • /
    • pp.14-21
    • /
    • 2001
  • This paper proposes an indirect adaptive fuzzy controller for general SISO nonlinear systems. In indirect adaptive fuzzy control, based on the proved approximation capability of fuzzy systems, they are used to capture the unknown nonlinearities of the plant. Until now, most of the papers in the field of controller design for nonlinear system considers the affine system using fuzzy systems which have fixed grid-rule structure. We proposes a dynamic fuzzy rule insertion scheme where fuzzy rule-base grows as time goes on. With this method, the dynamic order of the controller reduces dramatically and an appropriate number of fuzzy rules are found on-line. No a priori information on bounding constants of uncertainties including reconstruction errors and optimal fuzzy parameters is needed. The control law and the update laws for fuzzy rule structure and estimates of fuzzy parameters and bounding constants are determined so that the Lyapunov stability of the whole closed-loop system is guaranteed.

  • PDF

가변 풍속시 운전모드 절환을 고려한 이중여자 유도형 풍력발전기의 시뮬레이터 (A Wind Turbine Simulator for Doubly-Fed Induction-type Generator with Automatic Operation Mode Change during Wind Speed Variation)

  • 송승호;심동준;정병창
    • 전력전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.349-360
    • /
    • 2006
  • 이중여자 유도형 풍력발전 시스템은 다른 풍력발전 시스템에 비하여 에너지 변환 효율이 우수하고 전력변환 장치의 용량이 작아도 되는 특성이 있다. 이러한 특징을 살리기 위해서는 풍력발전 시스템에 입력되는 에너지의 변화를 고려하여 발전기의 제어기를 설계해야 한다. 본 논문에서는 상위 제어기와 하위 제어기로 구분하여 이중여자 유도 발전기의 제어기를 설계하였다. 상위 제어가는 풍력발전 시스템에 입력되는 에너지가 변화함에 따라서 발전기의 운전모드를 결정하고 제어 기준값을 계산한다. 발전기의 운전모드는 최저 속도 제어와 가변 토크 제어, 그리고 토크 제한 모드로 구성된다. 하위 제어기는 상위 제어기의 지령에 따라서 발전 시스템의 전류를 제어한다. 또한 본 논문에서는 3kW급 권선형 유도기를 사용한 이중여자 유도형 풍력발전기의 시뮬레이터를 제작하였다. 설계한 제어기는 시뮬레이터에 적용하여 실험적으로 검증하였다.