• 제목/요약/키워드: Grid use

검색결과 947건 처리시간 0.031초

An Improvement in Synchronously Rotating Reference Frame-Based Voltage Sag Detection under Distorted Grid Voltages

  • Sillapawicharn, Yutthachai;Kumsuwan, Yuttana
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1283-1295
    • /
    • 2013
  • This study proposed an improvement in synchronously rotating reference frame-based voltage sag detection under distorted grid voltages. In the past, the conventional synchronously rotating reference frame (CSRRF)-based voltage sag detection was generally used in the voltage sag compensation applications. Its disadvantage is a long delay of detection time. The modified synchronously rotating reference frame (MSRRF)-based voltage sag detection is able to detect the voltage sag with only a short delay in detection time. However, its operation under distorted grid voltage conditions is unavailable. This paper proposed the improvement of modified synchronously rotating reference frame (IMSRRF)-based voltage sag detection for use in distorted grid voltages with very fast operation of voltage sag detection. The operation of the proposed voltage sag detections is investigated via simulations and experimentations to verify the performance of the IMSRRF-based voltage sag detection.

Examination of Blurred Boundary and Avoidance of Modernist Grid in the Works of Toyo Ito

  • Kim, Lawrence
    • Architectural research
    • /
    • 제18권3호
    • /
    • pp.91-102
    • /
    • 2016
  • This study examines modernist grid and boundary in the works of Toyo Ito - two of the most important notions characterizing the development of Toyo Ito as an iconoclast architect. Early in his career, Ito recognized modernist architecture's inherent tendencies to establish homogenous order and divide space by function was alienating people from their context. Ito identified the notions of modernist grid and boundary as the agents of Modernism which inadvertently served to impose this systematic order and severe separation. As a reaction against these tendencies, Ito sought to avoid the use of modernist grid and blur boundary in his architecture. In Ito's career spanning over four decades, he engages in an exhaustive inquiry seeking to modify these two core elements of architecture. This study investigates these two notions in Ito's works and examines the significance of the architect's exploration in the context of Japan's Modernism.

포토에칭법에 의한 Digitron용 Grid제조에 관한 연구 (The Fabrication of Digitron Grid by Photoetching Process)

  • 김만;이종권
    • 한국표면공학회지
    • /
    • 제29권1호
    • /
    • pp.60-72
    • /
    • 1996
  • A photoetching process is widely used for small and high precision parts in machinery, electronic and semi-conductor industries. One of the high precision parts, grid is very important part of digitron which use electron display, and it is fabricated by only photoetching process because of high precision. In this study, to develop high precision digitron grid, characteristics of etching solution were investigated with electrochemical test, that was potentiodynamic test and immersion test in the ferric chloride solution and added some additives. Based on the electrochemical etching test, grid was fabricated by continuous photoetching process at various etching condition. From the result of measured line width and etching depth under-cut and etching factor were calculated. For the fabrication of 25$\mu\textrm{m}$ line width, optimal etching condition was etching temperature 40~$45^{\circ}C$, spray pressure 1.5kg/$\textrm{cm}^2$ and etching time 3~4min.

  • PDF

영구자석 동기발전기 시스템을 위한 회전자 관성에너지를 이용한 Sliding Mode제어 기반 LVRT 제어 (Use of Stored Energy in Rotor Inertia for LVRT of PMSG Wind turbine based on Sliding Mode Control)

  • 정대헌;계용호;김청훈;정정주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1058-1059
    • /
    • 2015
  • This paper describes a low-voltage ride-through method for the permanent magnet synchronous generator (PMSG) wind turbine system at a grid fault. The generator side converter regulates the DC link voltage instead of the grid side converter by storing the surplus active power in the rotor inertia during grid fault by the sliding mode controller. The grid side converter controls the grid active power keeping a maximum power point tracking. Simulation results for small scale PMSG wind turbine verify the efficiency of the control method.

  • PDF

주택 및 사무용 빌딩 내 전기기기의 전력 수요 패턴 분석 (Power demand pattern analysis for electric appliances in residential and commercial building)

  • 노성준;이순정;이상우;김광호
    • 산업기술연구
    • /
    • 제30권A호
    • /
    • pp.9-15
    • /
    • 2010
  • Recently, Smart Grid is a emerging topic in power and communication industry. Smart Grid refers to a evolution of the electricity supply infrastructure that monitors, protects, and intelligently optimize the operation of the interconnected elements including various type of generators, power grid, building/home automation system and end-use consumers. In order to successful implementation of Smart Grid, energy management function will be the key factor that coordinates and optimally controls the various loads according to the operating condition and environments, and the load patterns in residential and commercial building will be required as fundamental element for load management. In this study, we collects many types of energy usage data of electric appliances, analyze their load curves, and make the general load patterns for electrical appliance.

  • PDF

Advanced SOGI-FLL Scheme Based on Fuzzy Logic for Single-Phase Grid-Connected Converters

  • Park, Jin-Sang;Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.598-607
    • /
    • 2014
  • This paper proposes a frequency-locked loop (FLL) scheme for a single-phase grid-connected converter. A second-order generalized integrator (SOGI) based on fuzzy logic (FL) is applied to this converter to achieve precise phase angle detection. The use of this method enables the compensation of the nonlinear characteristic of the frequency error, which is defined in the SOGI scheme as the variation of the central frequency through the self-tuning gain. With the proposed scheme, the performance of the SOGI-FLL is further improved at the grid disturbances, which results in the stable operation of the grid converter under grid voltage sags or frequency variation. The PSIM simulation and experimental results are shown to verify the effectiveness of the proposed method.

감액 특성 향상을 위한 하이브리드(Sb/Ca) 액식 연축전지 개발 (Development of Hybrid (Sb/Ca) Flooded Lead-Acid Battery for Minimizing Water Loss)

  • 송승윤;임태섭;김성준;정연길;양승철
    • 한국재료학회지
    • /
    • 제32권3호
    • /
    • pp.146-152
    • /
    • 2022
  • One disadvantage of deep cycle flooded lead-acid batteries is increasing water loss caused by use of (+) Pb-Sb / (-) Pb-Sb alloy grid. Water loss is generated by the emission of hydrogen gas from the (-) electrode during battery charging. In this paper, we maintain cycle life aspect through the development of hybrid flooded lead-acid batteries to which a (+) Pb-Sb / (-) Pb-Ca grid is applied and deal with the improvement of water loss. The amount of water loss compared to that of the (-) Pb-Sb grid decreased when Ca was added to the (-) Pb grid. For the (-) Pb-Ca grid, it was confirmed that the time to reach 0.0 V, at which water decomposition occurs, was increased compared to that of the (-) Pb-Sb grid at the NPV (Negative Potential Voltage). In the cycle life test conducted with the BCI (Battery Council International) standard, compared to the (+) Pb-Ca grid, the (+) Pb-Sb grid increased the life cycle of the batteries and the (+) Pb-Ca grid showed an early end of life due to PbO corrosion layer generation, as determined through SEM / EDS and Tear Down analysis. In conclusion, by addition of Sb to (+) Pb grid and Ca to (-) Pb grid, we developed a hybrid flooded lead-acid battery that meets user requirements to improve water loss characteristics and preserve cycle life characteristics.

프로세스 결함 검출을 위한 OGSA 기반 그리드 서비스의 설계 및 구현 (A Grid Service based on OGSA for Process Fault Detection)

  • 강윤희
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2004년도 추계 종합학술대회 논문집
    • /
    • pp.314-317
    • /
    • 2004
  • 네트워크 및 소프트웨어 하부구조의 진보에 의해 이형의 컴퓨팅 자원 집합으로 구성된 환경에서 그리드 컴퓨팅 기술은 확산되고 있다. 그리드 컴퓨팅은 광대역으로 연결되어진 분산 컴퓨터들의 조정에 의한 사용을 요구한다. 그리드 컴퓨팅을 위한 다양한 시스템과 그리드 응용 서비스의 증가에 따라 그리드 운영환경은 네트워크 분리 및 노드 결함 등에 의해 높은 결함율을 가질 수 있다. 결함 검출은 그리드 응용 시스템의 강건성을 위해 시스템 설계 및 구현시의 필수적인 요소이다. 본 논문에서는 낮은 네트워크 트래픽 환경에서 높은 신뢰성 정공을 위한 OGSA(Open Grid Service Architecture) 기반의 자원 결함 검출 서비스를 제안한다.

  • PDF

Numerical simulation of propeller exciting force induced by milling-shape ice

  • Wang, C.;Li, X.;Chang, X.;Xiong, W.P.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제11권1호
    • /
    • pp.294-306
    • /
    • 2019
  • On the basis of the Computational Fluid Dynamics technique (CFD) combined with the overlap grid method, this paper establishes a numerical simulation method to study the problem of ice-propeller interaction in viscous flow and carries out a simulation forecast of the hydrodynamic performance of an ice-class propeller and flow characteristics when in the proximity of milling-shape ice (i.e., an ice block with a groove cut by a high-speed revolving propeller). We use a trimmed mesh in the entire calculation domain and use the overlap grid method to transfer information between the domains of propeller rotation calculation and ice-surface computing. The grid is refined in the narrow gap between the ice and propeller to ensure the accuracy of the flow field. Comparison with the results of the experiment reveals that the error of the hydrodynamic performance is within 5%. This confirms the feasibility of the calculation method. In this paper, we calculate the exciting force of the propeller, analyze the time domain of the exciting force, and obtain the curve of the frequency domain using a Fourier transform of the time-domain curve of the exciting force. The existence of milling-shape ice before the propeller can greatly disturb the wake flow field. Unlike in open water, the propeller bearing capacity shows a downward trend in three stages, and fluctuating pressure is more disordered near the ice.

Auction 알고리즘을 이용한 Shape Based 방식에 의한 PCB 자동 배선에 관한 연구 (A Study on the PCB automatic routing by shape based method using the auction algorithm)

  • 우경환;이천희
    • 정보처리학회논문지A
    • /
    • 제8A권3호
    • /
    • pp.269-278
    • /
    • 2001
  • 자동배선 시스템의 배선영역 모델링 방법은 그리드와 논 그리드 방식을 사용하고 있다. 그리드 방식은 PCB상에 전기적, 물리적 요소들이 적다 할지라도 보드와 그리드의 크기에 제약을 받기 때문에 자동배선 속도를 감소시키는 단점을 가지고 있다. 따라서 메모리 용량을 증가 시키게 된다. 논 그리드 방식(Shape based type)은 영역처리 방식을 사용하며, 배선영역에서 그리드 방식보다 44.2% 메모리 감소효과가 있다. 따라서 Via 수는 55.5%의 감소 효곽가 있으며, 총 배선 시간도 기존 PCB시스템보다 83.3% 향상되었다. 본 논문에서는 단일 원점에서 여러 목적지에 가장 빠르게 도달 할 수 있고 최단 경로 문제를 해결하는 auction 알고리즘을 적용한 Shape based 방식에 의하여 메모리 낭비 없이 빠른 속도로 자동 배선할 수 있는 PCB 자동 배선 시스템을 개발하였다. 또한 본 시스템은 IBM Pentium 컴퓨터 Windows 환경에서 Visual C++언어로 개발하였으며 다른 PC 와도 호환성을 가질수 있도록 개발 하였다.

  • PDF