• Title/Summary/Keyword: Grid type

Search Result 823, Processing Time 0.025 seconds

Numerical Study on the Three-Dimensional Centrifugal Compressor Volute Flow (원심 압축기 벌류트 3차원 유동의 수치해석)

  • Yoon Ju-Sig;Park Ki-Cheol;Chang Keun-Shik;Bae Hwang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.3 s.246
    • /
    • pp.222-229
    • /
    • 2006
  • Three dimensional turbulent flow in the scroll volute of centrifugal compressor has been numerically investigated in this paper by solving the Navier-Stokes equations and $\kappa-\varepsilon$ equation model. The computational grid for the flow field of the scroll volute has been constructed based on the multi-block grid concept, which is good to avoid the central grid singularity as well as to promote grid stretching toward the volute wall. Numerical result has been obtained for both the two- and three- dimensions. For the latter flow, result of the scroll volute flow is compared with that of the straight conical volute. This comparison has sorted out the characteristic features of the three-dimensional scroll-type volute flow of centrifugal compressor.

Power demand pattern analysis for electric appliances in residential and commercial building (주택 및 사무용 빌딩 내 전기기기의 전력 수요 패턴 분석)

  • Noh, Sung-Jun;Lee, Soon-Jeong;Lee, Sang-Woo;Kim, Kwang-Ho
    • Journal of Industrial Technology
    • /
    • v.30 no.A
    • /
    • pp.9-15
    • /
    • 2010
  • Recently, Smart Grid is a emerging topic in power and communication industry. Smart Grid refers to a evolution of the electricity supply infrastructure that monitors, protects, and intelligently optimize the operation of the interconnected elements including various type of generators, power grid, building/home automation system and end-use consumers. In order to successful implementation of Smart Grid, energy management function will be the key factor that coordinates and optimally controls the various loads according to the operating condition and environments, and the load patterns in residential and commercial building will be required as fundamental element for load management. In this study, we collects many types of energy usage data of electric appliances, analyze their load curves, and make the general load patterns for electrical appliance.

  • PDF

Grid Connected PV System with a Function to Suppress Disturbances caused by Solar-cell Array Instantaneous Output Power Fluctuation (태양전지어레이 순시 출력변동에 의한 외란의 억제기능을 갖는 계통연계형 태양광발전 시스템)

  • Kim, Hong-Sung;Choe, Gyu-Ha;Yu, Gwon-Jong
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.63-69
    • /
    • 1999
  • The conventional grid connected PV(Photovoltaic) system has a unstable output pattern due to its dependence on the weather condition, although solar-cell array averagely has a regular output characteristics to have a peak output nearly at noon. Therefore assuming the high density grid connection in the future, this unstable output pattern can be one of the main reasons to generate power disturbance such as voltage variation, frequency variation and harmonic voltage generation in low voltage distribution line. However general grid connected solar-cell system do not have functions to cope with these disturbances. Therefore this study proposed a advanced type grid connected PV system with functions to suppress output power fluctuation due to solar-cell array output variation and showed the levelling effect of fluctuation due to instantaneous array output variation.

  • PDF

Study and Design of L-C-L Filter for Single-Phase Grid-Connected PV Inverter (단상 계통연계 태양광 인버터용 L-C-L 필터 설계 및 분석)

  • Cha, Han-Ju;Vu, Trung-Kien
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.228-230
    • /
    • 2009
  • Nowadays, the LCL-filter type becomes an attractive grid interfacing for grid-connected Voltage Source Inverter (VSI). LCL-filter can render the current harmonics attenuation around the switching frequency by using smaller inductance than L-filter. This paper presents a study about the LCL-filter design for single-phase grid-connected inverter in Photovoltaic (PV) system. According to the expected current ripple, the inductances of the filter can be determined. Based on the absorbed reactive power on capacitor, the capacitance can be calculated. Due to the theoretical analysis, a LCL-filter based single phase grid connected inverter control system are simulated. The studied simulation results are given to validate the theoretical analysis.

  • PDF

Improved Control Strategy Based on Space Vectors for Suppressing Grid-Side Current Harmonics in Three-Phase Current Source Rectifiers with a Hybrid Switch

  • Xu, Yan;Lu, Guang-Xiang;Jiang, Li-Jie;Yi, Gui-Ping
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.497-503
    • /
    • 2015
  • This paper analyses the harmonic pollution to power grids caused by several high-power rectifiers, summarizes the requirements for rectifiers in suppressing grid-side current harmonics and optimizes a new-type of current source PWM rectifier with a hybrid switch. The rectifier with a hybrid switch boasts significant current characteristics and cost advantages in the high-power area. To further enhance the working frequency of the current source rectifier with a hybrid switch for suppressing grid-side harmonics and reducing the inductance size, this paper proposes an optimal control strategy based on space vector. It also verifies that the optimal control strategy based on space vector can reduce the total harmonic distortion of the grid-side current of the rectifier with a hybrid switch via circuit simulation and experimental results.

High Speed Grid Voltage Detection Method for 3 Phase Grid-Connected Inverter during Grid Faults (전원사고 시 3상 계통연계 인버터의 전원 전압 고속 검출 방법)

  • Choi, Hyeong-Jin;Song, Seung-Ho;Jeong, Seung-Gi;Choi, Ju-Yeop;Choy, Ick
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.65-72
    • /
    • 2009
  • The new method is proposed to improve high speed detection of grid voltage phase and magnitude during a voltage dip due to a grid faults. Usually, A LPF(Low Pass Filter) is used in the feedback loop of PLL (Phase Locked Loop) system because the measured grid voltage contains harmonic distortions and sensor noises. so, a new design method of the loop gain of the PI -type controller in the PLL system is proposed with the consideration of the dynamics of the LPF. As a result, a better transient response can be obtained with the proposed design method. The LPF frequency and PI controller gain are designed in coordination according to the steady state and dynamic performance requirement. This paper shows the feasibility and the usefulness of the proposed methods through the computer simulation and the lab-scale experiments.

A Comparative Study on Measuring Methods of Absorption Characteristics for Electromagnetic Wave Using Standing Wave Measurement Method and Time Domain Method. (정재파측정법과 Time Domain법에 의한 전파흡수능측정법의 비교 연구)

  • 김동일;김상태;박지용;정세모
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1994.10a
    • /
    • pp.79-90
    • /
    • 1994
  • The goal of this research is to get a measuring system for absorption characteristics of electromagnetic wave absorbers in ferrite type which are lat grid-type special type etc. It is however very difficult to measure the absorption characteristics as in low frequency as in 30 MHz, To solve the problem therefore we propose a standing wave method and a measurement method in time domain using parallel striplines construct the measuring system and measure the characteristics of ferrite microwave absorbers in grid type using the proposed measuring system.

  • PDF

A Comparative Study on Measuring Methods of Absorption Characteristics for Electromagnetic Wave Absorber Using Time Domain Method (Time Domain법에 의한 전파흡수체의 흡수능 측정법의 비교연구)

  • 김동일;김상태;박지용;정세모
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.2
    • /
    • pp.11-18
    • /
    • 1995
  • The goal of this research is to get a measuring system for absorption characteristics of electromagnetic wave absorbers in fernite type which are flat, grid-type and special type, etc. It is, however, very difficult to measure the absorption characteristics in as low frequency as 30 MHz. To solve the problem, therefore, we propose a standing wave method and a measurement method in time domain using paralledl striplines, construct the measuring system, and measure the charac- teristics of ferrite microwave absorbers in grid type using the proposed measuring system.

  • PDF

Dynamic analysis of Microturbine and FuelCell in MicroGrid using EMTP-RV (마이크로터빈과 연료전지의 EMTP-RV 모델링을 통한 마이크로그리드 내 동특성 분석)

  • Seo, Gyu-Seok;Ju, Jae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.42-48
    • /
    • 2010
  • The Microsource has to supply high quality Power that has high reliability and high energy efficiency to Load according to operating type of Microgrid. The energy sources of microsource type have various dynamic characteristic and transient response corresponding to classes and application skill. This paper shows dynamic characteristic of Microgrid according to Energy Source of microsource type. This research has been carried out by detailed modelling of Microturbine system and Fuelcell system. All models are realized by EMTP/RV and simulated change of operating type and load increase within Microgrid of DC constant voltage inverter model and Microturbine, Fuelcell based Microsource.

Multiple Decoupling Current Control Strategies for LCL Type Grid-Connected Converters Based on Complex Vectors under Low Switching Frequencies

  • Liu, Haiyuan;Shi, Yang;Guo, Yinan;Wang, Yingjie;Wang, Wenchao
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.1034-1044
    • /
    • 2019
  • In medium-voltage and high-voltage high-power converters, the switching devices need to operate at a low switching frequency to reduce power loss and increase the power capacity. This increases the delay of the signal sampling and PWM. It also makes the cross-couplings of the d-q current components more severe. In addition, the LCL filter has three cross-coupling loops and is prone to resonance. In order to solve these problems, this paper establishes a complex vector model of an LCL type grid-connected converter. Based on this model, two multiple decoupling current control strategies with passive damping / notch damping are proposed for the LCL type grid-connected converter. The proposed strategies can effectively eliminate the cross-couplings of the converter, achieve independent control of the d-q current components, expand the stable region and suppress the resonance of the LCL filter. Simulation and experimental results verify the correctness of the theoretical analysis and the feasibility of the proposed strategies.