• 제목/요약/키워드: Grid synchronization

검색결과 72건 처리시간 0.023초

Strategy for the Seamless Mode Transfer of an Inverter in a Master-Slave Control Independent Microgrid

  • Wang, Yi;Jiang, Hanhong;Xing, Pengxiang
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.251-265
    • /
    • 2018
  • To enable a master-slave control independent microgrid system (MSCIMGS) to supply electricity continuously, the microgrid inverter should perform mode transfer between grid-connected and islanding operations. Transient oscillations should be reduced during transfer to effectively conduct a seamless mode transfer. This study uses a typical MSCIMGS as an example and improves the mode transfer strategy in three aspects: (1) adopts a status-tracking algorithm to improve the switching strategy of the outer loop, (2) uses the voltage magnitude and phase pre-synchronization algorithm to reduce transient shock at the time of grid connection, and (3) applies the hybrid-sensitivity $H_{\infty}$ robust controller instead of the current inner loop to improve the robustness of the controller. Simulations and experiments show that the proposed strategy is more practical than the traditional proportional-derivative control mode transfer and effective in reducing voltage and current oscillations during the transfer period.

A Quantitative Evaluation and Comparison of Harmonic Elimination Algorithms Based on Moving Average Filter and Delayed Signal Cancellation in Phase Synchronization Applications

  • Xiong, Liansong;Zhuo, Fang;Wang, Feng;Liu, Xiaokang;Zhu, Minghua;Yi, Hao
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.717-730
    • /
    • 2016
  • The harmonic components of grid voltage result in oscillations of the calculated phase obtained via phase synchronization. This affects the security and stability of grid-connected converters. Moving average filter, delayed signal cancellation and their related harmonic elimination algorithms are major methods for such issues. However, all of the existing methods have their limitations in dealing with multiple harmonics issues. Furthermore, few studies have focused on a comparison and evaluation of these algorithms to achieve optimal algorithm selections in specific applications. In this paper, these algorithms are quantitatively analyzed based on the derived mathematical models. Moreover, an enhanced moving average filter and enhanced delayed signal cancellation algorithms, which are applicable for eliminating a group of selective harmonics with only one calculation block, are proposed. On this basis, both a comprehensive comparison and a quantitative evaluation of all of the aforementioned algorithms are made from several aspects, including response speed, required data storage size, sensitivity to sampling frequency, and elimination of random noise and harmonics. With the conclusions derived in this paper, better overall performance in terms of harmonic elimination can be achieved. In addition, experimental results under different conditions demonstrate the validity of this study.

New Control Strategy for Three-Phase Grid-Connected LCL Inverters without a Phase-Locked Loop

  • Zhou, Lin;Yang, Ming;Liu, Qiang;Guo, Ke
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.487-496
    • /
    • 2013
  • The three-phase synchronous reference frame phase-locked loop (SRF-PLL) is widely used for synchronization applications in power systems. In this paper, a new control strategy for three-phase grid-connected LCL inverters without a PLL is presented. According to the new strategy, a current reference can be generated by using the instantaneous power control scheme and the proposed positive-sequence voltage detector. Through theoretical analysis, it is indicated that a high-quality grid current can be produced by introducing the new control strategy. In addition, a kind of independent control for reactive power can be achieved under unbalanced and distorted grid conditions. Finally, the excellent performance of the proposed control strategy is validated by means of simulation and experimental results.

Frequency Synchronization of Three-Phase Grid-Connected Inverters Controlled as Current Supplies

  • Fu, Zhenbin;Feng, Zhihua;Chen, Xi;Zheng, Xinxin;Yin, Jing
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1347-1356
    • /
    • 2018
  • In a three-phase system, three-phase AC signals can be translated into two-phase DC signals through a coordinate transformation. Thus, the PI regulator can realize a zero steady-state error for the DC signals. In the control of a three-phase grid-connected inverter, the phase angle of grid is normally detected by a phase-locked loop (PLL) and takes part in a coordinate transformation. A novel control strategy for a three-phase grid-connected inverter with a frequency-locked loop (FLL) based on coordinate transformation is proposed in this paper. The inverter is controlled as a current supply. The grid angle, which takes part in the coordinate transformation, is replaced by a periodic linear changing angle from $-{\pi}$ to ${\pi}$. The changing angle has the same frequency but a different phase than the grid angle. The frequency of the changing angle tracks the grid frequency by the negative feedback of the reactive power, which forms a FLL. The control strategy applies to non-ideal grids and it is a lot simpler than the control strategies with a PLL that are applied to non-ideal grids. The structure of the FLL is established. The principle and advantages of the proposed control strategy are discussed. The theoretical analysis is confirmed by experimental results.

SRF-PLL을 이용한 계통연계형 단상 인버터의 전원 위상각 검출시 옵셋 오차 영향에 관한 연구 (A Study on Effects of Offset Error during Phase Angle Detection in Grid-tied Single-phase Inverters based on SRF-PLL)

  • 권영;성의석;황선환
    • 조명전기설비학회논문지
    • /
    • 제29권10호
    • /
    • pp.73-82
    • /
    • 2015
  • This paper proposes an ripple reduction algorithm and analyzes the effects of offset and scale errors generated by voltage sensor while measuring grid voltage in grid-tied single-phase inverters. Generally, the grid-connected inverter needs to detect the phase angle information by measuring grid voltage for synchronization, so that the single-phase inverter can be accurately driven based on estimated phase angle information. However, offset and scale errors are inevitably generated owing to the non-linear characteristics of voltage sensor and these errors affect that the phase angle includes 1st harmonic component under using SRF-PLL(Synchronous Reference Frame - Phase Locked Loop) system for detecting grid phase angle. Also, the performance of the overall system is degraded from the distorted phase angle including the specific harmonic component. As a result, in this paper, offset and scale error due to the voltage sensor in single-phase grid connected inverter under SRF-PLL is analyzed in detail and proportional resonant controller is used to reduce the ripples caused by the offset error. Especially, the integrator output of PI(Proportional Integral) controller in SRF-PLL is selected as an input signal of the proportional resonant controller. Simulation and experiment are performed to verify the effectiveness of the proposed algorithm.

A Stable Black-Start Strategy for a Stand-Alone DC Micro-Grid

  • Cha, Jae-Hun;Han, Yoon-Tak;Park, Kyung-Won;Oh, Jin-Hong;Choi, Tae-Seong;Ko, Jae-Hun;MAHIRANE, Philemon;An, Jae-Yun;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.30-37
    • /
    • 2018
  • Unlike an AC system, a DC system does not cause problems with synchronization, stability, reactive power, system losses, and cost. However, more research is still required for the application of DC Systems. This paper proposes a stable black-start strategy for a stand-alone DC micro-grid, which consists of an energy storage system, photovoltaic generator, wind-turbine generator, diesel generator, and DC loads. The proposed method is very important for avoiding inrush current and transient overvoltage in the power system equipment during restoration after a blackout. PSCAD/EMTDC software was used to simulate, analyze, and verify the method, which was found to be stable and applicable for a stand-alone DC micro-grid.

그리드 동기형 PLL의 위상오차 개선 (Improvement of PLL Phase Error for Grid Synchronization)

  • 이치환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.508-509
    • /
    • 2012
  • 그리드 연계 인버터의 주파수 위상 동기를 위해 사용하는 SRF PLL의 입력함수를 Vq및 Vd 전압을 복합적으로 사용하여 응답특성을 개선시켰다. 기존의 SRF PLL에서 Vq만을 이용한 구조는 위상범위 [$-{\pi}/2$, ${\pi}/2$]에서만 선형 동작이 가능하지만, 제안된 구조는 $2{\pi}$ 영역 모두에서 선형 동작이 가능토록 하였다. 시뮬레이션으로 위상차 ${\pi}$에서 기존 SRF PLL의 부동작을 확인하고 제안된 방법의 속응성을 보였다.

  • PDF

계통 연계형 태양광 발전 시스템의 위상 동기화를 위한 디지털 PLL 제어 (Digital PLL Control for Phase-Synchronization of Grid-Connected PV System)

  • 김용균;최종우;김흥근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권9호
    • /
    • pp.562-568
    • /
    • 2004
  • The frequency and phase angle of the utility voltage are important in many industrial systems. In the three-phase system, they can be easily known by using the utility voltage vector. However, in the case of single phase system, there are some difficulties in detecting the information of utility voltage. In conventional system, the zero-crossing detection method is widely used, but could not obtain the information of utility voltage instantaneously. In this paper, the new digital PLL control using virtual two phase detector is proposed with a detailed analysis of single-phase digital PLL control for utility connected systems. The experimental results under various utility conditions are presented and demonstrate an excellent phase tracking capability in the single-phase grid-connected operation.

스마트그리드를 위한 자율형 상태관측기 연구 (The Study on Autonomous State Estimator for Smart Grid)

  • 박종찬;이세인
    • 전기학회논문지P
    • /
    • 제60권1호
    • /
    • pp.32-36
    • /
    • 2011
  • In this study, authors have proposed the autonomous state estimation which has been composed with IEC61850, GPS time synchronization and objective model design concept. The proposed method is able to supervise/correct measurement and communication error from SCADA. The major advantages of the proposed autonomous state estimation are that it is possible to evaluate integrity of data measured and transferred from SCADA, to reduce human intervention and to expense national-size applications such as EMS (Energy Management System), WAMS (Wide Area Monitoring System) or WAPS (Wide Area Protection System). This study addresses the issues related to the operation of the smart grid and proposes a new automated approach to achieve this goal. Through applying the proposed system to IEEE 14-bus test electric system, we prove the possibility of the proposed idea.

독립형 / 계통연계 호환형 단상 인버터 (Stand-Alone / Grid-Connected compatible Hybrid Single Phase Inverter)

  • 정구영;양태철;강경수;노정욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.39-41
    • /
    • 2018
  • 독립형 인버터의 경우 상용 AC 계통(Utility Grid)이 없는 지역에서, 출력으로 단상 AC 전압(220Vrms / 60Hz)을 발생하는 전력 시스템이며 휘발유 연소 에너지, 풍력 에너지, 태양광 에너지 등 다양한 형태의 에너지를 전기 에너지로 변환하여 시스템의 입력으로 사용한다. 계통 연계 형 인버터의 경우 상용 AC 계통에 직접 연결하여, 발전된 전력을 계통에 주입(Inject)하는 전력 시스템을 말하며 출력으로 계통 전압과 동기화(Synchronization)된 단상 AC 전류를 발생시킨다. 기존 독립형 인버터의 출력에 계통 전원을 연결하면 작동이 불가능하고, 반대로 기존 연계형 인버터의 출력을 계통 전원 없이 동작하려고 하는 경우 또한 작동이 불가능하다. 본 논문에서는 상기 기존 기술의 한계를 극복할 수 있는 독립형 / 계통연계 호환형 단상 인버터를 제안하고 실제 구현을 통해 작동을 검증하였다.

  • PDF