• 제목/요약/키워드: Grid regulation

검색결과 127건 처리시간 0.026초

A Novel Three-Phase Four-Wire Grid-Connected Synchronverter that Mimics Synchronous Generators

  • Tan, Qian;Lv, Zhipeng;Xu, Bei;Jiang, Wenqian;Ai, Xin;Zhong, Qingchang
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2221-2230
    • /
    • 2016
  • Voltage and frequency stability issues occur in existing centralized power system due to the high penetration of renewable energy sources, which decrease grid absorptive capacity of them. The grid-connected inverter that mimics synchronous generator characteristics with inertia characteristic is beneficial to electric power system stability. This paper proposed a novel three-phase four-wire grid-connected inverter with an independent neutral line module that mimics synchronous generators. A mathematical model of the synchronous generator and operation principles of the synchronverter are introduced. The main circuit and control parameters design procedures are also provided in detail. A 10 kW prototype is built and tested for further verification. The primary frequency modulation and primary voltage regulation characteristics of the synchronous generator are emulated and automatically adjusted by the proposed circuit, which helps to supports the grid.

가파도 마이크로그리드에서의 풍력발전 연계를 위한 2MVA급 배터리 에너지 저장시스템(BESS) 적용 및 실증 (The Application and Verification of the 2MVA Battery Energy Storage System(BESS) with Wind-turbine in Micro-grid of Gapado, Jeju)

  • 김승모;오승진;이종학;김태형;권병기;안재민;진경민;최창호
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.303-311
    • /
    • 2014
  • This paper shows the test result of 2MVA BESS(Battery Energy Storage System) with wind-turbine in micro-grid of the Gapado. To implement of micro-grid with BESS, characteristics of generator and customer load in grid are considered. Also, to operate of 2-parallel PCU(Power Conversion Unit) in BESS, the droop control is adopted with operating mode of grid independent. Performances of BESS with wind-turbine were verified by analysis of power quality such as voltage harmonics, ratio of voltage and frequency regulation, and by measurement of waveform such as output voltage and current.

수퍼 커패시터와 배터리를 이용한 마이크로그리드 시스템의 제어 (Control of Microgrid System with Super-capacitor and Battery)

  • 최용오;이언석;정세교;송유진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.242-243
    • /
    • 2013
  • This paper presents a voltage and frequency regulation of a Micro-grid using a Battery energy storage system (BESS) and super-capacitor (SPC). The control methods for the both BESS and SPC are proposed to improve the regulation performance and battery life span. The simulation results using the PSCAD/EMTDC are provided to show the effectiveness of the proposed control.

  • PDF

호흡기보호구의 밀착계수와 안면구조의 관계 (Correlation of Fit Factors for Respirators and Anthropometric Dimension)

  • 한돈희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제31권3호
    • /
    • pp.440-448
    • /
    • 1998
  • In many developed countries, for example, USA, respirator fit testing is required before entering specific work environment to ensure that the respirator worn satisfies a minimum of fit and that the user knows when the respirator fits properly. Unfortunately because we have not fit test regulation in Korea, a lot of workers wearing respirators may be potentially exposed to hazards. This study was conducted to evaluate the fitting performance for respirators and correlation fit factors with facial dimensions of wearers. 110 subjects (70 males, 40 females) were fit tested for three quarter masks, i.e., two domestic-made Mask 2, and Y and one foreign-made Mask T using PortaCount 8020. A facial dimension survey of the same subjects was conducted to develop a facial dimension grids fer correlation fit factors with facial dimension parameters. A facial dimension grid was developed on the basis of face length and lip length for quarter masks. The results obtained were as follows : 1 Fit factors of Mask T were much higher than those of Masks Z, and Y. 2. Males were fitted more properly than females. 3. Male in box 'f' of grid would be adequately fitted Mask Y and male in box 'b', 'e', 'f', 'h' of grid would be sufficiently fitted Mask T. Female in box 'h' of grid may have a good fitting performance for both Mask Y, and T. But subjects in all boxes of grid would be inadequately fitted Mask Z.

  • PDF

풍력발전단지 관리·분석 시스템의 Real-Time Simulator 도입을 위한 계통모델 연동방안 연구 (A Study About Grid Impose Method On Real-Time Simulator For Wind-Farm Management System)

  • 정승민;유연태;김현욱;장길수
    • 조명전기설비학회논문지
    • /
    • 제29권7호
    • /
    • pp.28-37
    • /
    • 2015
  • Owing to the variability of large-scaled wind power system, the development of wind farm management technologies and related compensation methods have been receiving attention. To provide an accurate and reliable output power, certain wind farm adopts a specified management system including a wind prediction model and grid expectation solutions for considering grid condition. Those technologies are focused on improving the reliability and stability issues of wind farms, which can affect not only nearby system devices but also a voltage condition of utility grid. Therefore, to adapt the develop management system, an expectation process about voltage condition of Point of Common Coupling should be integrated in operating system for responding system requirements in real-time basis. This paper introduce a grid imposing method for a real-time based wind farm management system. The expected power can be transferred to the power flow section and the required quantity about reactive power can be calculated through the proposed system. For the verification process, the gauss-seidel method is introduced in the Matlab/Simulink for analysing power flow condition. The entire simulation process was designed to interwork with PSCAD for verifying real power system condition.

600kW급 용융탄산염 연료전지 발전시스템용 EBOP 제어시스템 (Control System of 600kW EBOP for Molten Carbonate Fuel Cell Generation System)

  • 황태식;정우택;양병훈;김광섭;권병기;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.18-20
    • /
    • 2008
  • An electrical balance of plant(EBOP) of a 600kW molten carbonate fuelcell (MCFC) has to transit from grid-connected(GC) mode to grid-independent(GI) mode when a grid is in a fault conditions. A minimum transition time is limited by four cycle for a 600kW MCFC to ride through a grid fault. In this paper, we propose a control algorithm of a 600kW EBOP for a MCFC system. The EBOP has three operation modes, i.e., GC mode, GI mode, and grid-synchronized(GS) mode. The EBOP controls output currents in a GC mode and regulates output voltages in GI or GS mode. GS mode is defined as an interface between GC mode and GI mode to make a mode transition smooth, i.e., limitation of inrush currents, regulation of output voltages within ANSI standard. Simulations and experiments carried out to verify the effectiveness of the proposed control algorithm.

  • PDF

마이크로그리드 운영에 따른 전력자립 향상을 위한 에너지저장장치의 적정보조금 산정 (Calculation of Appropriate Subsidies for Energy Storage System to Improve Power Self-sufficiency Consider Microgrid Operation)

  • 최연주;김성열
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.486-492
    • /
    • 2017
  • In recent years, renewable energy sources have been mentioned as solution to environmental regulation and energy supply-demand. Energy storage systems are needed to mitigate the intermittent output characteristics of renewable energy sources and to operate micro grid efficiently using renewable energy generation systems. However, despite the necessity of energy storage system, this cannot secure the economical efficiency of the energy storage system by high initial cost. In this paper, a micro grid is constructed to supply electric power to industrial customers by using solar power generation system and energy storage system among renewable energy generation power sources and operated to improve energy independence. In the case study, we use photovoltaic system which is representative renewable energy generation system. Unlike conventional photovoltaic system, this system uses floating photovoltaic system with the advantage of having high output and no land area limitations. It is operated for the purpose of improving energy independence in the micro grid. In order to secure economical efficiency, the energy storage system operates a micro grid with a minimum capacity. Finally, this paper calculates the appropriate subsidy for the energy storage capacity.

A Seamless Transfer Algorithm Based on Frequency Detection with Feedforward Control Method in Distributed Generation System

  • Kim, Kiryong;Shin, Dongsul;Lee, Jaecheol;Lee, Jong-Pil;Yoo, Dong-Wook;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.1066-1073
    • /
    • 2015
  • This paper proposes a control strategy based on the frequency detection method, comprising a current control and a feed-forward voltage control loop, is proposed for grid-interactive power conditioning systems (PCS). For continuous provision of power to critical loads, PCS should be able to check grid outages instantaneously. Hence, proposed in the present paper are a frequency detection method for detecting abnormal grid conditions and a controller, which consists of a current controller and a feedforward voltage controller, for different operation modes. The frequency detection method can detect abnormal grid conditions accurately and quickly. The controller which has current and voltage control loops rapidly helps in load voltage regulation when grid fault occurs by changing reference and control modes. The proposed seamless transfer control strategy is confirmed by experimental results.

Feedforward Pitch Control Using Wind Speed Estimation

  • Nam, Yoon-Su;Kim, Jeong-Gi;Paek, In-Su;Moon, Young-Hwan;Kim, Seog-Joo;Kim, Dong-Joon
    • Journal of Power Electronics
    • /
    • 제11권2호
    • /
    • pp.211-217
    • /
    • 2011
  • The dynamic response of a multi-MW wind turbine to a sudden change in wind speed is usually slow, because of the slow pitch control system. This could cause a large excursion of the rotor speed and an output power over the rated. A feedforward pitch control can be applied to minimize the fluctuations of these parameters. This paper introduces the complete design steps for a feedforward pitch controller, which consist of three stages, i.e. the aerodynamic torque estimation, the 3-dimensional lookup table for the wind seed estimation, and the calculation of the feedforward pitch amount. The effectiveness of the feedforward control is verified through numerical simulations of a multi-MW wind turbine.

스마트 배전시스템의 최적 구성 방안에 관한 연구 (A Study on the Optimal Design for Smart Distribution System)

  • 지성호;손준호;송석환;노대석
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2009년도 추계학술발표논문집
    • /
    • pp.834-836
    • /
    • 2009
  • The authors have been discussed the optimal voltage regulation method and on-line real time method using artificial neural networks in the distribution system interconnected with Distributed Generation and Storage(DSG) systems. However, these methods have difficulty in dealing with the random load variations and operation characteristics of a number of DSG systems. To overcome these problems, this paper shows the basic concepts of smart grid system which is considered as one of the power delivery system in the near future and presents an evaluation method on the impacts of customer voltages by the operation of smart grid system. The smart grid system can change the system configuration in a flexible manner by using the static switches and offer the different power qualities in power services through the power quality control centers.

  • PDF