• 제목/요약/키워드: Grid regulation

검색결과 127건 처리시간 0.026초

Decentralized Vehicle-to-Grid Design for Frequency Regulation within Price-based Operation

  • Kim, Seung Wan;Jin, Young Gyu;Song, Yong Hyun;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1335-1341
    • /
    • 2015
  • The utilization of electric vehicles has been suggested to support the frequency regulation of power system. Assuming that an intermediate aggregator exists, this study suggests a decentralized vehicle-to-grid operation scheme in which each vehicle-to-grid aggregator can behave independently of the power system operator. To implement this type of decentralized operation, this study adopts a price-based operation that has been proposed by many researches as an alternative operation scheme for the power system. In this environment, each vehicle-to-grid aggregator can determine its participation in vehicle-to-grid service in consideration of its residual energy of aggregated system and real-time market price. Consequently, the main purpose of this study is to verify whether or not the vehicle-to-grid power can effectively support the current frequency regulation function within the price-based operation scheme. Specifically, a frequency regulation method is proposed based on the real-time price signal, and a feedback controller for battery management is designed for decentralized vehicle-to-grid operation.

계통 연계형 풍력 발전 시스템의 LVRT 제어 전략 (LVRT Control Strategy of Grid-connected Wind Power System)

  • 신호준;설승기
    • 전력전자학회논문지
    • /
    • 제16권2호
    • /
    • pp.182-190
    • /
    • 2011
  • 본 논문은 계통 전압 사고 상황에서 계통 연계형 풍력 발전 시스템이 만족시켜줘야 할 LVRT(Low Voltage Ride Through) 제어 전략을 제안한다. LVRT 규정은 계통 전압 사고 시 풍력 발전 시스템이 지켜야 할 부분들을 전압 감소율과 사고 시간에 대해 나타내고 있다. 특히 전압 감소율이 10% 이상일 경우에는 풍력 발전 시스템은 규정된 무효 전류를 전력 계통에 제공하여 계통 전압 확보에 이바지해야 한다. 본 논문에서의 LVRT 규정은 세계적으로 가장 엄격한 규정인, 독일 계통 연계 규정(German Grid Code)을 기준으로 하고 풀 스케일(Full-scale) 가변 속도 전력 변환 시스템을 고려하여 제어 전략을 수립한다. 본 LVRT 제어 전략은 계통 사고 시 LVRT 규정을 모두 만족시킴과 동시에 직류단 전압 제어의 추가적인 알고리즘으로 직류단 전압의 제어를 통하여 전체 풍력 발전 시스템의 전력 균형을 기할 수 있다. 3상 전압 지락 사고의 경우 계통으로의 전력 제어가 불가능하여 계통 측 컨버터가직류단 전압을 제어할 수 없으므로, 전력 제어의 기능을 발전기 측 인버터로 이행 시켜 상황에 따라 유연한 직류단 전압 제어가 가능함을 보였다. 시뮬레이션과 실험을 통해 LVRT 제어 전략의 타당성을 검증하였다.

주파수 조정을 위한 4MW 전력 저장 시스템 연구 (The Study on 4MW Energy Storage System for Frequency Regulation)

  • 고광수;이충우;강병관;오승훈;이윤재;최은식;류강열;김희중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.125-126
    • /
    • 2013
  • ESS(Energy Storage System) for Improve the quality of the power grid, supply reliability, system stability and the efficient operation method of power is drawing attention. According to changes in the load of the power system frequency will be adjustable in real time in response to changes in the frequency of the grid, so thermal power output is mainly controlled in order to keep the grid frequency stable. ESS for adjusting the frequency of the grid when the frequency rises to grid and charge the energy storage device. If the frequency drops to discharge the battery power to the grid and the future is expected to replace the thermal power plant. This paper describes 4MW ESS for the frequency regulation and find out about the characteristics through the PSCAD/EMTDC.

  • PDF

Seamless Transfer of Single-Phase Utility Interactive Inverters with a Synchronized Output Regulation Strategy

  • Xiang, Ji;Ji, Feifan;Nian, Heng;Zhang, Junming;Deng, Hongqiao
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1821-1832
    • /
    • 2016
  • This study presents a strategy using the synchronized output regulation method (SOR) for controlling inverters operating in stand-alone and grid-connected modes. From the view point of networked dynamic systems, SOR involves nodes with outputs that are synchronized but also display a desirable wave shape. Under the SOR strategy, the inverter and grid are treated as two nodes that comprise a simple network. These two nodes work independently under the stand-alone mode. An intermediate mode, here is named the synchronization mode, is emphasized because the transition from the stand-alone mode to the grid-connected mode can be dealt as a standard SOR problem. In the grid-connected mode, the inverter operates in an independent way, in which the voltage reference changes for generalized synchronization where its output current satisfies the required power injection. Such a relatively independent design leads to a seamless transfer between operation modes. The closed-loop system is analyzed in the state space on the basis of the output regulation theory, which improves the robustness of the design. Simulations and experiments are performed to verify the proposed control strategy.

Coordinated Control of Reactive Power between STATCOMs and Wind Farms for PCC Voltage Regulation

  • Nguyen, Thanh Hai;Lee, Dong-Choon;Van, Tan Luong;Kang, Jong-Ho
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.909-918
    • /
    • 2013
  • This paper proposes a coordinated control of the reactive power between the STATCOMs (static synchronous compensators) and the grid-side converters (GSC) of wind farms equipped with PMSGs (permanent-magnet synchronous generators), by which the voltage fluctuations at the PCC (point of common coupling) are mitigated in the steady state. In addition, the level of voltage sags is reduced during grid faults. To do this, the GSC and the STATCOM supply reactive power to the grid coordinately, where the GSCs are fully utilized to provide the reactive power for the grid prior to the STATCOM operation. For this, the GSC capability of delivering active and reactive power under variable wind speed conditions is analyzed in detail. In addition, the PCC voltage regulation of the power systems integrated with large wind farms are analyzed for short-term and long-term operations. With this coordinated control scheme, the low power capacity of STATCOMs can be used to achieve the low-voltage ride-through (LVRT) capability of the wind farms during grid faults. The effectiveness of the proposed strategy has been verified by PSCAD/EMTDC simulation results.

전력 보조서비스 제공을 위한 전기자동차 충/방전 최적화 (Battery Charge and Discharge Optimization for Vehicle-to-grid Regulation Service)

  • 김욱원;신홍열;김진오;김규호
    • 전기학회논문지
    • /
    • 제63권8호
    • /
    • pp.1033-1038
    • /
    • 2014
  • Electric vehicles should be connected to power system for charge and discharge of battery. Besides vehicle's battery is charged for a power source, it is also reversibly possible to provide power source from battery to power system. Researches on battery usage for regulation resources have been progressed and could cause cost increase excessively because they distribute regulation capacity equally without considering the battery wear cost of SOC, temperature, voltage and so on. This causes increase of grid maintenance cost and aggravate economical efficiency. In this paper it is studied that the cost could be minimized according to the battery condition and characteristic. The equation is developed in this paper to calculate the possible number of charge and discharge cycle, according to SOC level and weighting factors representing the relation between battery life and temperature as well as voltage. Thereafter, the correlation is inferred between the battery condition and wear cost reflecting the battery price, and the expense of compensation is decided according to the condition on battery wear-out of vehicle. In addition, using realtime error between load and load expectation, it is calculated how much regulation capacity should be provided.

태양광-배터리-수퍼캡을 갖는 직류 홈 그리드의 버스 전압 제어 (Bus Voltage Regulation of DC Home Grid with PV-Battery-Ultracap)

  • 헤리얀토누르;이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.467-468
    • /
    • 2019
  • This paper proposes an improved bus voltage regulation scheme in filter-based reference current generation of power management for DC home grid with photovoltaics (PV), battery, and ultracapacitor (ultracap) by using feedforward terms instead of the filter output to produce the ultracap reference current. Simulation results have proved the effectiveness of the proposed scheme.

  • PDF

스마트그리드 환경에서 전기자동차 배터리를 이용한 V2G의 활용방안에 관한 연구 (A Study on the V2G Application using the Battery of Electric Vehicles under Smart Grid Environment)

  • 최진영;박은성
    • 전기학회논문지P
    • /
    • 제63권1호
    • /
    • pp.40-45
    • /
    • 2014
  • This study examines the system and process of battery stored energy in vehicles and suggest the effective area for the use of V2G(vehicle-to-grid) from Jeju Smart Grid Demonstration Project. V2G means technology of electric power transmission from the battery of electric-drive vehicles to state grid. As for the increasing of effectiveness for demand-side control, V2G is a very good alternative. In the U.S., the utilization of electric vehicles is under 40% on average. In this case, we can use he battery of electric vehicle as role of frequency regulation or generator of demand-side resource. V2G, which is the element of Smart Transportation, consists of electric vehicle battery, BMS(battery management system), OBC(on-board charger), charging infrastructure, NOC(network operating center) and TOC(total operation center). V2G application has been tested for frequency regulation to secure the economical efficiency in the United States. In this case, the battery cycle life is not verified its disadvantage. On the other hand, Demand Response is required by low c-rate of battery in electric vehicle and It can be small impact on the battery cycle life. This paper concludes business area of demand response is more useful than frequency regulation in V2G application of electric vehicles in Korea. This provides the opportunity to create a new business for power grid administrator with VPP(virtual power plant).

Provision of Two-area Automatic Generation Control by Demand-side Electric Vehicle Battery Swapping Stations

  • Xie, Pingping;Shi, Dongyuan;Li, Yinhong
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.300-308
    • /
    • 2016
  • Application of demand-side resources to automatic generation control (AGC) has a great significance for improving the dynamic control performance of power system frequency regulation. This paper investigates the possibility of providing regulation services by demand-side energy storage in electric vehicle battery swapping stations (BSS). An interaction framework, namely station-to-grid (S2G), is presented to integrate BSS energy storage into power grid for giving benefits to frequency regulation. The BSS can be regarded as a lumped battery energy storage station through S2G framework. A supplementary AGC method using demand-side BSS energy storage is developed considering the vehicle user demand of battery swapping. The effects to the AGC performance are evaluated through simulations by using a two-area interconnected power grid model with step and random load disturbance. The results show that the demand-side BSS can significantly suppress the frequency deviation and tie-line power fluctuations.

Optimal Scheduling of Utility Electric Vehicle Fleet Offering Ancillary Services

  • Janjic, Aleksandar;Velimirovic, Lazar Zoran
    • ETRI Journal
    • /
    • 제37권2호
    • /
    • pp.273-282
    • /
    • 2015
  • Vehicle-to-grid presents a mechanism to meet the key requirements of an electric power system, using electric vehicles (EVs) when they are parked. The most economic ancillary service is that of frequency regulation, which imposes some constraints regarding the period and duration of time the vehicles have to be connected to the grid. The majority of research explores the profitability of the aggregator, while the perspective of the EV fleet owner, in terms of their need for usage of their fleet, remains neglected. In this paper, the optimal allocation of available vehicles on a day-ahead basis using queuing theory and fuzzy multi-criteria methodology has been determined. The proposed methodology is illustrated on the daily scheduling of EVs in an electricity distribution company.