• Title/Summary/Keyword: Grid emission

Search Result 116, Processing Time 0.019 seconds

Study on the Application of V2G for Electric Vehicles in Korea Using Total Cost of Ownership Analysis (총소유비용 분석을 이용한 전기차의 V2G 도입에 대한 연구)

  • Kim, Younghwan;Lee, Jae-Seung
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.129-143
    • /
    • 2015
  • Increasing concerns on climate change and energy security accelerated policies to reduce green-house gas emission, especially from the transportation sector. Electric vehicle (EV) has been on the spotlight to deal with such environmental issue and V2G (Vehicle-to-Grid) technology began to draw attentions as an alternative to reduce ownership costs while contributing to an efficient and decentralized power grid. This study conducts a scenario analysis on total cost of ownership of EV under V2G scheme and compare with non-V2G EV and Internal Combustion Engine (ICE) vehicle. As result, V2G service is expected to provide an annual average profit of $210 to EV users willing to reverse flow its residual power in the battery. The profit from V2G service leaves a margin of $4,530 over operational lifetime, compared with $2,420 cost of charge for non-V2G EV. In summary, total cost of ownership of V2G-capable EV was 6.2% less than non-V2G EV and 10.2% higher than ICE vehicle. The results confirm a comparative economic advantage of operating EV under V2G scheme. Increased number of EVs with V2G service has shown to provide positive effects to power industry for valley filling in load distribution, thus, favorably increasing the overall economic feasibility.

Design of Database and System for Application of Forest Biomass (산림바이오매스 활용을 위한 데이터베이스 및 시스템 설계)

  • Lee, Hyun Jik;Koo, Dae Soung;Ru, Ji Ho
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.21 no.4
    • /
    • pp.13-20
    • /
    • 2013
  • Due to the global warming, international agreements have been propelled by industrialized countries. These days, there are various studies and projects to reduce the carbon emission quantity in South Korea, because South Korea is a strong candidate for a newly industrialized nation by Kyoto Protocol. Therefore, this study arranges plans to create various thematic map by producing database that can manage various datum based on grid spatial objects to manage quantity of forest biomass and carbon dioxide. Moreover, this study designs a system to create forest biomass by using the best method of calculation with LiDAR data and KOMPSAT-2 satellite images. In addition, this study designs a biomass monitoring system for public institutions to register biomass, suggesting actual plans to extract, manage, and utilized forest biomass.

Suggestions on the Selection Method of Priority Monitoring Sites for Hazardous Air Pollutants in Megacities (유해대기오염물질 모니터링을 위한 대도시 우선순위 측정지점 선정기법 제안)

  • Kwon, Hye-Ok;Kim, Seong-Joon;Kim, Yong Pyo;Kim, Sang-Kyun;Hong, Ji-Hyung;Choi, Sung-Deuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.544-553
    • /
    • 2017
  • There is an overall guideline of the installation of air quality monitoring stations in Korea, but specified steps for the selection of monitoring sites for hazardous air pollutants(HAPs) are not provided. In this study, we proposed a systematic method for the selection of monitoring sites for HAPs using geographic information system (GIS). As a case study, the Seoul metropolitan area (Seoul, Incheon, and Gyeonggi Province) was chosen, and 15 factors including population, vehicle registration, and emission data were compiled for each grid cell ($7km{\times}7km$). The number of factors above the top 30% of individual data for each grid cell was used to select priority monitoring sites for HAPs. In addition, several background sites were added for data comparison and source identification. Three scenarios were suggested: Scenario 1 with 7 sites, Scenario 2 with 17 sites, and Scenario 3 with 30 sites. This proposal is not the final result for an intensive monitoring program, but it is an example of method development for selecting appropriate sampling sites. These results can be applied not only to HAPs monitoring in megacities but also to the national HAPs monitoring network.

Implementation of PC-based education PLC(Power Line-network Communication) control system using Labview (LabView를 이용한 PC기반의 교육용 전력선망 통신 제어시스템 구현)

  • Park, Tae-Jin;Lee, Un-Sun;Lee, Sang-Hee;Lee, Jong-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.3
    • /
    • pp.730-739
    • /
    • 2013
  • More than 30% of energy in Korea was spent in lighting part and then the consumption level and $CO_2$ emission will be increase from now. In this like situation, control-system construction for street-lamp of a smart grid-based that it has important meaning. Nowadays as a result, as an trying to utilize using Power-line-network communication modem and application a terminal in industrial fields, in this paper, we are want to implement the Power-line-network communication control system of PC-based. Therefore it will be use varied communication test-equipment and tools through the system. For experimentation, using the MODEM was able to use Planet production of based on the ZIC protocol and then the application program use the LabView. The result is primarily focused on equipments control by the PLC, and that we are able to perform each test with PLC equipment for experiment it.

Mapping the Polarization of the Radio-Loud Lyman Alpha Nebula B3 J2330+3927

  • Yang, Yujin;You, Chang;Zabludoff, Ann;Smith, Paul;Jannuzi, Buell;Prescott, Moire
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.28.3-29
    • /
    • 2015
  • $Ly{\alpha}$ nebulae, or "$Ly{\alpha}$ blobs", are extended (~100 kpc), bright (L[$Ly{\alpha}$] ~ 1044 erg/s) clouds of $Ly{\alpha}$-emitting gas. The origin of the $Ly{\alpha}$ emission remains unknown, but recent theoretical work suggests that measuring the polarization could discriminate among powering mechanisms. we will discuss current status of $Ly{\alpha}$ polarization observations at high-redshift and our on-going survey program. We will present the first narrow-band, imaging polarimetry of a $Ly{\alpha}$ blob, B3 J2330+3927 at z=3.09, with an embedded, radio-loud AGN (C. You et al. in prep.). The AGN lies near the blob's $Ly{\alpha}$ emission peak and its radio lobes align roughly with the blob's semi-major axis. With the SPOL polarimeter on the MMT telescope, we map the polarization in a grid of circular apertures of radius 0.6" (4.4 kpc), detecting a significant (>$2{\sigma}$) polarization fraction P% in 10 apertures and achieving strong upper-limits (as low as 2%) elsewhere. The degree of the polarization map increases from P% ~ 5% at ~5 kpc from the blob center to ~20% at the outer part (~30 kpc). The detections are distributed asymmetrically, roughly along the blob's major axis. The polarization angles (${\Theta}$) are mostly perpendicular to this axis. These results are consistent with the picture that $Ly{\alpha}$ photons produced at the AGN (or the host galaxy) are resonantly scattered away from the center. Higher polarization fraction on the radio jet suggests that the gas is more optically thin along the jet than the off-axis region.

  • PDF

Development and Testing of a Prototype Long Pulse Ion Source for the KSTAR Neutral Beam System

  • Chang Doo-Hee;Oh Byung-Hoon;Seo Chang-Seog
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.357-363
    • /
    • 2004
  • A prototype long pulse ion source was developed, and the beam extraction experiments of the ion source were carried out at the Neutral Beam Test Stand (NBTS) of the Korea Superconducting Tokamak Advanced Research (KSTAR). The ion source consists of a magnetic bucket plasma generator, with multi-pole cusp fields, and a set of tetrode accelerators with circular apertures. Design requirements for the ion source were a 120kV/65A deuterium beam and a 300 s pulse length. Arc discharges of the plasma generator were controlled by using the emission-limited mode, in turn controlled by the applied heating voltage of the cathode filaments. Stable and efficient arc plasmas with a maximum arc power of 100 kW were produced using the constant power mode operation of an arc power supply. A maximum ion density of $8.3{\times}10^{11}\;cm^{-3}$ was obtained by using electrostatic probes, and an optimum arc efficiency of 0.46 A/kW was estimated. The accelerating and decelerating voltages were applied repeatedly, using the re-triggering mode operation of the high voltage switches during a beam pulse, when beam disruptions occurred. The decelerating voltage was always applied prior to the accelerating voltage, to suppress effectively the back-streaming electrons produced at the time of an initial beam formation, by the pre-programmed fast-switch control system. A maximum beam power of 0.9 MW (i.e. $70\;kV{\times}12.5\;A$) with hydrogen was measured for a pulse duration of 0.8 s. Optimum beam perveance, deduced from the ratio of the gradient grid current to the total beam current, was $0.7\;{\mu}perv$. Stable beams for a long pulse duration of $5{\sim}10\;s$ were tested at low accelerating voltages.

A X-ray Tube Using Field Emitter Made by Multi-walled Carbon Nanotube Yarns

  • Kim, Hyun-Suk;Castro, Edward Joseph D.;Kwak, Seung-Im;Ju, Jin-Young;Hwang, Yong-Gyoo;Lee, Choong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.392-392
    • /
    • 2011
  • Carbon nanotubes (CNT) emitter has widely become an attractive mechanism that draws growing interests for cold cathode field emission.$^{1,2}$ CNT yarns have demonstrated its potential as excellent field emitters.$^3$ Extensive simulations were carried out in designing a CNT yarn-based cathode assembly. The focal spot size dependence on the anode surface of the geometric parameters such as axial distance of the electrostatic focus lens from the cathode and the applied bias voltages at the cathode, grid mesh and electrostatic focus lens were studied. The detailed computer simulations using Opera 3D electromagnetic software$^4$ had revealed that a remarkable size of focal spot under a focusing lens triode type set-up design was achieved. The result of this optimization simulation would then be applied for the construction of the CNT yarn based micro-focus x-ray tube with its field emission characteristics evaluated.

  • PDF

Flickering Frequency and Pollutants Formation in Microwave Induced Diffusion Flames (마이크로파가 인가된 화염에서의 주파수 특성과 오염물질 생성)

  • Jeon, Young Hoon;Lee, Eui Ju
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.22-27
    • /
    • 2016
  • The use of electromagnetic wave has been interested in various energy industry because it enhances a flame stability and provides higher safety environments. However it might increase the pollutant emissions such as NOx and soot, and have harmful influence on human and environments. Therefore, it is very important to understand interaction mechanism between flame and electromagnetic wave from environmental point of view. In this study, an experiment was performed with jet diffusion flames induced by electromagnetic wave. Microwave was used as representative electromagnetic wave and a flickering flame was introduced to simulate the more similar combustion condition to industry. The results show that the induced microwave enhances the flame stability and blowout limit. The unstable lifted flickering flames under low fuel/oxidizer velocity is changed to stable attached flames or lift-off flames when microwave applied to the flames, which results from the abundance of radical pool. However, NOx emission was increased monotonically with increasing the microwave power as microwave power increased up to 1.0 kW. The effects might be attributed to the heating of combustion field and thermal NOx mechanism will be prevailed. Soot particle was examined at the post flame region by TEM grid. The morphology of soot particle sampled in the microwave induced flames was similar to the incipient soot that is not agglomerated and contain a lots of liquid phase hydrocarbon such as PAH, which soot particle formed near reaction zone is oxidized on the extended yellow flame region and hence only unburned young particles are emitted on the post flame region.

A Study on the Thermal and Pollution Performances of the Heating Boilers with NG-H2 Mixture Ratio (난방용 보일러에서 NG-H2 혼소율에 따른 열 및 공해 성능의 검토)

  • SEO, JUNSUN;KIM, YOUNG-JIC;PARK, JUNKYU;LEE, CHANG-EON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.6
    • /
    • pp.573-584
    • /
    • 2021
  • Hydrogen is evaluated as one of the new energy sources that can overcome the limitations and pollution problems of conventional fossil fuels. Although hydrogen is CO2-free, attention is required in NOx emission and flame stability in order to use hydrogen in existing gas fuel system. However, use of electric grids is an unrealistic strategy for decarbonization for residential and commercial heating. Instead, use of H2 that utilizes city gas grid is suggested as a reasonable alternative in terms of compatibility with existing systems, economic feasibility, and accessibility. In this study, the thermal efficiency and NOx performance of the boiler according to the H2 mixture ratio and vapor humidified ratio are reviewed for a humidified NG-H2 boiler that vapor humidity to combustion air. Mixed fuel with H2 (20%) is almost similar to NG in terms of efficiency, flame temperature, and pollution performance. Thus, it is expected to be directly compatible with the existing NG system. If the exhaust temperature of the H2 boiler is lowered to around 60℃ at a humidified ratio of 15-20%, the NOx emission concentration can be suppressed to about 5-10 ppm. The level of efficiency reaches 87% of the rated load efficiency, which is equivalent to the highest grade achievable.

Analyses on Techno-economic Aspects and Green Hydrogen Production Capability of MW-scale Low-temperature Water Electrolyzers in Jeju Island, South Korea (제주도 MW급 저온 수전해 수소 생산 시스템의 그린수소 생산 능력 및 경제성 분석 )

  • KOSAN ROH;YEONGJIN KIM;HONGJUN JEON;WOOHYUN KIM;HEESANG KO;KYOUNG SOO KANG;SEONG UK JEONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.3
    • /
    • pp.235-245
    • /
    • 2023
  • Techno-economic analyses on a 5-MW water electrolysis system for hydrogen production, operated in Jeju Island where the portion of renewable energy in the power grid is the highest in Korea, have been performed. The cost of hydrogen production and the economic feasibility of the hydrogen production system have been mainly analyzed based on the levelized-cost-of-hydrogen model. The effects of carbon emission trading and renewable power purchase method have been considered to reduce the cost of green hydrogen production in the case studies. This economic analysis model is expected to be used to derive a business model for green hydrogen production.