Construction and Operation of Small Solar Plant Using Smart-Off-Grid: Case of Tanzania-Korea Innovative Technology and Energy Center (스마트-독립전력망을 사용한 소규모 태양광 발전소의 건설과 운영: 한국-탄자니아 적정기술 거점센터의 사례)

  • Kim, Jisoo;Jung, Woo-Kyun;Ha, Bo-Ra;Moon, Ji-Hyun;Rhee, Herb;Ahn, Sung-Hoon
    • Journal of Appropriate Technology
    • /
    • v.5 no.2
    • /
    • pp.62-69
    • /
    • 2019
  • Supplying stable electric power is one of the important objectives of the Official Development Assistance (ODA) because it is strongly related with improving living standards and income levels in the region. However, rural areas in many developing countries are not properly connected to national power grids, and even areas connected to national power grids are frequently blacked out due to limitations in power capacity. These lack of electric power is a major obstacle to improving income levels and improving living standards in those areas. The Korea-Tanzania Innovative and Energy Center (iTEC), which was established by Seoul National University in cooperation with the Nelson-Mandela Africa Institute of Science and Technology and Technology (NM-AIST) try to build a small solar power plant using a smart-off grid in rural area of Tanzania, where there is no electricity. 10 kW and 7 kW solar power plants are built in Mkalama Village in Kilimanajaro Region and Ngurdoto Village in Arusha Region to provide power to about 50 households each. In addition, smart monitoring systems were installed to collect data about status of power system and power consumption of each house. iTEC seeks for sustainable improvement the income level and quality of life of rural residents in developing countries through the construction of small solar power plants using smart-off grid, and the implementation of various connected projects.

Wind load analysis of Structure for Folding Solar Power System (접이식 태양광 발전 구조물의 풍하중해석)

  • Son, Chang-Woo;Kim, Tae-Kyun;Seo, Tae-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.1-7
    • /
    • 2018
  • A folding solar power system is a stand-alone system and is a structure with solar panels attached. It consists of supporting parts and folding parts for ease of movement. While the efficiency of solar panels is also important to produce electricity by maximizing the power efficiency of solar panels, the most important thing is structure stability. The folding solar power structure intended to be developed in this study is a collapsible structure that is easy to move and install into systems that can produce electricity from grid to independent. Since these structures are installed outdoors, wind loads, snow cover, etc. In this paper, the wind loads most affected by the folding solar power generation structure were obtained using the MeshFree Finite Element Method. MeshFree is a program that makes it easier for users to interpret by simplifying the mesh tasks required by an existing analysis. The analysis showed that the greater the angle of inclination of the wind to the ground, the greater the wind load. In addition, reliability was ensured by wind load testing.

Implementation of Secure System for Blockchain-based Smart Meter Aggregation (블록체인 기반 스마트 미터 집계 보안 시스템 구축)

  • Kim, Yong-Gil;Moon, Kyung-Il
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.2
    • /
    • pp.1-11
    • /
    • 2020
  • As an important basic building block of the smart grid environment, smart meter provides real-time electricity consumption information to the utility. However, ensuring information security and privacy in the smart meter data aggregation process is a non-trivial task. Even though the secure data aggregation for the smart meter has been a lot of attention from both academic and industry researchers in recent years, most of these studies are not secure against internal attackers or cannot provide data integrity. Besides, their computation costs are not satisfactory because the bilinear pairing operation or the hash-to-point operation is performed at the smart meter system. Recently, blockchains or distributed ledgers are an emerging technology that has drawn considerable interest from energy supply firms, startups, technology developers, financial institutions, national governments and the academic community. In particular, blockchains are identified as having the potential to bring significant benefits and innovation for the electricity consumption network. This study suggests a distributed, privacy-preserving, and simple secure smart meter data aggregation system, backed up by Blockchain technology. Smart meter data are aggregated and verified by a hierarchical Merkle tree, in which the consensus protocol is supported by the practical Byzantine fault tolerance algorithm.

Warm Start Up Time Reduction Through the Increase of Boiler Water Circulating Pump Inlet Water Temperature Rate of the Thermal Power Plant (관수온도 상승률 증가에 의한 발전용 보일러의 온간기동시간 단축에 관한 연구)

  • Kang, Hee-Seong;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.10 no.1
    • /
    • pp.47-53
    • /
    • 2014
  • The national capacity of electricity of Korea was 81,737 MW and the peak demand was renewed by the record of 71,230 MW in 2012 which has been increasing since the first lighting ceremony had taken place in the Royal Palace(Kyung-Bok Goong) in 1887. Aa the counteract on the rapid increasing of the demand, Korean government is constructing and operating the high capacity nuclear and thermal power plants, however, the operating reserve on weekdays is small while those of weekends are more than 40% of capacity, so they are providing the pumped-storage power plants with the surplus electricity during weekends and operating the power plants which cost higher production price and located in the capital area with WSS (Weekly Start and Stop) mode including the Seoul Thermal Power Plant. Since the Seoul Thermal Power Plant is spending huge amount of expenses for more than 30 times of the WSS annually due to the high production cost even though it is in Seoul, the core of the demand, I chose the power plant unit #5 which was on the grid in 1969 for the case to confirm reducing 23% of the warm start-up time by applying the "Start-up time management program", and that reducing 35% of the water temperature increasing time by accelerate the increasing rate of the inlet temperature of the water circulating pump.

  • PDF

A Study on the Integration Costs in Korean Electric System in Accordance with Increasing Solar and Wind Power Generation (태양광·풍력 발전 증가에 따른 한국의 전력시스템 내 통합비용에 관한 연구)

  • Kim, Doo Chun;Kim, Kwang Jin;Park, Jung Gu
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.42-54
    • /
    • 2019
  • The solar and wind power is spreading as a means to $CO_2$ reduction, but it has the characteristics of the volatility depending on the weather changes. This article aims to estimate the additional integration costs in Korea electric system in response to such volatility of increasing solar and wind power generation, using Korea electric power trading analyzer(KEPTA). The analysis utilizes the statistics of "8th Basic Plan for Long-term Electricity Supply and Demand" and "Renewable Energy Plan 3020". As the results, integration costs will be estimated 13.94Won/kWh~32.55Won/kWh, consisting of 8.94Won/kWh as back-up costs, 1.03Won/kWh~4.45Won/kWh as balancing costs, and 3.97Won/kWh~19.16Won/kWh as grid-costs. These results suggest that when the integration costs are secured, Korea electric system will be expected in the stable situation. This article leaves the further studies with taking the technological development of solar and wind power generation, the introduction of energy storage system, and wholesale price of electricity into consideration.

Analysis of carbon emission reduction effect due to electricity conversion of container port's CHE (컨테이너 항만 하역장비의 친환경 전환에 따른 탄소 배출저감 효과 분석)

  • Ahn, Yong Sung;Lee, Hyang-Sook;Lee, Ji-Won
    • Journal of Korea Port Economic Association
    • /
    • v.40 no.2
    • /
    • pp.39-52
    • /
    • 2024
  • As the 'Eco-friendly conversion project for Port's CHE(Cargo handling Equipment) ' which has started in 2014 ends in 2024, in addition to the existing 'Low pollution' paradigm to respond to fine dust problems, a full-fledged 'Zero-emission' conversion is to be required to implement 2050 carbon neutrality at the port level. Accordingly, this study calculated the future replacement demand for container handling equipments at the four major domestic ports(Busan, Incheon, Yeosu Gwangyang, and Ulsan), and assumed a scenario where every CHE supposed to eb replaced is electrified inturn every year. And then the resulting future emission reduction effect accordingly was calculated and analyzed. In particular, compared and analyzed the emission outlook applying the life-cycle concept(LCA), which is being adopted as a new emission calculation standard in most industrial fields, and the existing emission calculation concept that only considers direct emissions within the port, to provide more effective implications for the promotion of follow-up conversion projects. According to the analysis results, if the CHE is replaced according to the proposed schedule, it is expected that the existing emissions can be reduced by 79% compared to BAU in 2025 and 97.4% in 2030. However, if the LCA is applied, it is expected to be reduced by only 27.6% by 2030. This suggests that port's CHE must be converted to zero emissions and at the same time establish an Ports' self-sufficient energy grid based on renewable energy.

Single-phase Control Algorithm of 4-Leg type PCS for Micro-grid System (마이크로그리드용 4-Leg 방식 PCS의 각상 개별제어 알고리즘에 관한 연구)

  • Kim, Seung-Ho;Choi, Sung-Sik;Kim, Seung-Jong;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.817-825
    • /
    • 2017
  • The AC-common bus microgrid system can overcome several weaknesses of the DC microgrid system by interconnecting the DC/AC inverters used for renewable energy with an AC network. Nevertheless, the unbalanced loads inherent in the electric power systems of island and small communities can deteriorate the performance of the AC microgrid system. This is because of the limited voltage regulation capability and mixed power flow in the voltage source inverter. In order to overcome the unbalanced load condition, this paper proposes a voltage and current control algorithm for the 4-leg inverter based on the single phase d-q control method, as well as the modeling of the voltage controller using Matlab/Simulink S/W. From the S/W simulation and experiment of the 250KW proto-type inverter, it is confirmed that the proposed algorithm is a useful tool for the design and operation of the AC microgrid system.

Effect of Electroplating Parameters on Oxygen Evolution Reaction Characteristics of Raney Ni-Zn-Fe Electrode (Raney Ni-Zn-Fe 전극의 산소발생 반응 특성에 미치는 도금변수의 영향)

  • CHAE, JAEBYEONG;KIM, JONGWON;BAE, KIKWANG;PARK, CHUSIK;JEONG, SEONGUK;JUNG, KWANGJIN;KIM, YOUNGHO;KANG, KYOUNGSOO
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.1
    • /
    • pp.23-32
    • /
    • 2020
  • The intermittent characteristics of renewable energy complicates the process of balancing supply with demand. Electrolysis technology can provide flexibility to grid management by converting electricity to hydrogen. Alkaline electrolysis has been recognized as established technology and utilized in industry for over 100 years. However, high overpotential of oxygen evolution reaction in alkaline water electrolysis reduces the overall efficiency and therefore requires the development of anode catalyst. In this study, Raney Ni-Zn-Fe electrode was prepared by electroplating and the electrode characteristics was studied by varying electroplating parameters like electrodeposition time, current density and substrate. The prepared Raney Ni-Zn-Fe electrode was electrochemically evaluated using linear sweep voltammetry. Physical and chemical analysis were conducted by scanning electron microscope, energy dispersive spectrometer, and X-ray diffraction. The plating time did not changed the morphology and composition of the electrode surface and showed a little effect on overpotential reduction. As the plating current density increased, Fe content on the surface increased and cauliflower-like structure appeared on the electrode surface. In particular, the overpotential of the electrode, which was prepared at the plating current density of 320 mA/㎠, has showed the lowest value of 268 mV at 50 mA/㎠. There was no distinguishable overpotential difference between the type of substrate for the electrodes prepared at 80 mA/㎠.

Study of Electric Charge Saving Plan Using High-speed Charging Wireless Railway System (급속충전방식 무가선 전동차 시스템을 이용한 전기요금 절감 방안 연구)

  • Go, Hyo-Sang;Cho, In-Ho;Ryu, Joon-Hyoung;Kim, Gil-Dong
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.1
    • /
    • pp.31-42
    • /
    • 2017
  • Many studies have been performed to reduce electric consumption in railway systems. Due to its low conduction loss and high regenerative braking efficiency characteristics, the ESS powered railway system is chosen as a promising candidate for future railway systems. This paper introduces the ESS powered railway system and analyzes current power charge calculation methods that have been set up by KEPCO (Korea Electric Power Corporation). Based on the analysis, this paper proposes two different power charge reduction methods for the railway system. One is to smooth the peaks of traction energy consumption by supplying additional energy to the grid. The other is to save electric charge by reducing electric energy consumed by the railway during the energy peak time, 2 p.m.~5 p.m., which has highest 'Won/kWh' rates. To verify the effectiveness of the proposed method, the power charge of Seoul Metro Line 2 is recalculated using the method.

Adaptive Gain-based Stable Power Smoothing of a DFIG

  • Lee, Hyewon;Hwang, Min;Lee, Jinsik;Muljadi, Eduard;Jung, Hong-Ju;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2099-2105
    • /
    • 2017
  • In a power system that has a high wind penetration, the output power fluctuation of a large-scale wind turbine generator (WTG) caused by the varying wind speed increases the maximum frequency deviation, which is an important metric to assess the quality of electricity, because of the reduced system inertia. This paper proposes a stable power-smoothing scheme of a doubly-fed induction generator (DFIG) that can suppress the maximum frequency deviation, particularly for a power system with a high wind penetration. To do this, the proposed scheme employs an additional control loop relying on the system frequency deviation that operates in combination with the maximum power point tracking control loop. To improve the power-smoothing capability while guaranteeing the stable operation of a DFIG, the gain of the additional loop is modified with the rotor speed and frequency deviation. The gain is set to be high if the rotor speed and/or frequency deviation is large. The simulation results based on the IEEE 14-bus system demonstrate that the proposed scheme significantly lessens the output power fluctuation of a WTG under various scenarios by modifying the gain with the rotor speed and frequency deviation, and thereby it can regulate the frequency deviation within a narrow range.