• 제목/요약/키워드: Grid connected

검색결과 1,223건 처리시간 0.028초

DSP를 이용한 엑티브 필터 기능 추가형 태양광발전시스템의 운전특성에 관한 연구 (A Study on PV Power Generation System Adding the Function of Shunt Active Filler Using DSP)

  • 서효룡;박영길;김종현;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1169-1170
    • /
    • 2006
  • Grid connected PV(Photovoltic) generation systems are becoming and actual and general. The power output of PV system is directly affected by the weather conditions. And when AC power supply is needed, power conversion by an inverter and a MPPT control are necessary. The PV power generation system can be treated to a harmonics source for the power distribution system. So, the PV system combined the function of active filter system can be useful applied in power distribution system. AF(Active Filters) intended for harmonic solutions are expending their functions from harmonic compensation of nonlinear loads into harmonic isolation between utilities and consumer. With the test analysis of the proposed control strategy of PV-AF system, the outcome of the test shows the stability and effectiveness of the proposed PV-AF system. The various capability of AF has been proved in previous research and usage. In this paper, authors present a DSP controlled PV-AF system for power conditioning in three-phase industrial or commercial power systems and verify it through experimental results.

  • PDF

다이나믹 MPPT를 적용한 최대전력지점추종 알고리즘 (The New MPPT Algorithm for the Dynamic MPPT Efficiency)

  • 고석환;정영석;소정훈;황혜미;주영철
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.1-10
    • /
    • 2014
  • The efficiency of the maximum power point tracking(MPPT) of inverter which is used in grid-connected photovoltaic systems is changed according to dynamic environment conditions. Hence, this paper evaluates the performance of the proposed method and other MPPT algorithm on the basis of European Efficiency Test(EN50530). The modeling of MPPT algorithm is made by the Matlab & Simulink. In the result of simulation, the more control period is shorter, the more MPPT efficiency is higher. Also, the Proposed MPPT algorithm has higher performance than other MPPT algorithm with no regard to control period.

마이크로그리드에서 양방향 계통연계형 인버터의 자율적이며 끊김없는 모드전환 기법 (A Seamless and Autonomous Mode Transfer Method of Bidirectional Grid Connected Inverter in Microgrid.)

  • 박성열;권민호;신양진;정호영;강수한;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.36-38
    • /
    • 2018
  • 중요부하를 가지고 있는 계통연계 인버터는 계통과의 연결이 끊길 경우 중요부하에 안정적인 전압공급을 위하여 끊김 없는 모드전환 동작이 요구된다. 기존 인버터는 계통연계 시 전류제어모드, 독립운전 시에는 전압제어모드로 운전을 한다. 그래서 모드전환 시 제어기절체로 인한 출력전압에 심각한 과도상태가 발생할 수 있으며 단독운전 검출 전에도 불안정한 전압을 부하에 공급하게 되어 중요부하에 큰 손상을 입힐 수 있다. 본 논문에서는 LCL필터 뿐만 아니라 LC필터 구조에서도 적용이 가능하며, 양방향 운전 시 자율적인 모드전환이 가능한 계통연계 인버터의 모드전환 기법을 제안한다. 제안된 알고리즘은 5kW 시작품을 제작하여 타당성을 검증하였다.

  • PDF

2011년 나주시 태양광 발전 시스템의 운전특성 (2011, The Analysis Operating Characteristics of Photovoltaic System in Naju-city)

  • 현정우;이남진;차인수;김동묵;최정식
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.359-363
    • /
    • 2011
  • Building-integrated photovoltaics(BIPV)are increasingly incorporate into new domestic and industrial buildings as a proncipal or ancillary source of electrical power, and are on of the fastest growing segments of the photovoltaic industry. This paper presents operational features analysis and PCS(Power conversion System) factors of grid-connected 30kW BIPV on library of Dongshin University. The data consisted of insolation, Temperature, solar-cell performance and inverter performance are collected by IVIsion web monitoring system and analyzed. The analyzed data gave this paper effect elements of optimal operation.

  • PDF

ICT융복합 기술을 이용한 차세대 배전계통 운영 시스템 설계 및 검증 (Design and Verification of Advanced Distribution Management System using Information and Communication Convergence Technology)

  • 김동욱;박영배;추철민;조성호;서인용
    • 디지털산업정보학회논문지
    • /
    • 제15권4호
    • /
    • pp.19-29
    • /
    • 2019
  • Recently, with the rise of environmental issues and the change of government policy (Renewable Energy 3020 Implementation Plan), a large amount of renewable energy such as solar and wind power is connected to the power system, and most of the renewable energy is concentrated in the power distribution network. This causes many problems with the voltage management and the protection coordination of the grid due to the its intermittent power generation. In order to effectively operate the distribution network, it is necessary to deploy more intelligent terminal devices in the field to measure the status of the distribution network and develop various operation functions such as visualization and big data analysis to support the power distribution system operators. In addition, the failover technology must be supported for the non-stop operation of the power distribution system. This paper proposes the system architecture of new power distribution management system to cope with high penetration of renewable energy. To verify the proposed system architecture, the functional unit test and performance measurement were performed.

지/단락실증시험에서 MW급 계통연계형 ESS 절연/보호시스템 성능 분석에 관한 연구 (Analysis on Insulation and Protection Characteristics of Grid Connected ESS in Ground/Short-Circuit Fault)

  • 김진태;이승용;박상진;차한주;김수열
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권2호
    • /
    • pp.119-122
    • /
    • 2020
  • With recent ESS (Energy Storage System) fire accident, the fault protection performance is becoming more important. However, there has never been any experiments with the protection performance on the faults in the ESS system level. In this study, the effect of AC ground fault and IGBT (Insulated Gate Bipolar mode Transistor) short-circuit failure on MW class ESS was performed experimentally for the first time in the world. First of all, the effect of the AC single line ground fault on battery was analyzed. Moreover, the transient voltage was investigated as a function of the battery capacity and the power level. Finally, the breaking capability and insulation performance of ESS were examined under PCS short-circuit fault condition. Through the tests, it was found that ESS protection system safely blocked the faulty current regardless of the faults, whereas the electronic parts such as IGBT and MC (Magnetic Contactor) were broken by the fault current. Also, the electrical breakdown in ESS resulted from the transient voltage during the protection process.

PSCAD/EMTDC에 의한 직류연계선 오버홀시 제주계통의 전력품질 분석 (Power Quality Analysis of Jeju Power System during HVDC Overhaul using PSCAD/EMTDC)

  • 강보승;김재홍;김일환;김세호;오성보;송기혁
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.82-84
    • /
    • 2008
  • This paper presents the modeling and power quality analysis of Jeju island power system connected with wind farm, and thermal power plant. It is for indicating the influence of wind farm operation in steady and transient state in Jeju island power system during the HVDC system overhaul period. For the computer simulation, three kinds of main item are modeled, which are 67[MW] wind farm, thermal power plant and Jeju power load. To analyze the influence of the wind power generation to the Jeju power system, two kinds of simulations are carried out by using the PSCAD/EMTDC program. One is the steady state operation under the variable speed wind, and the other is the transient state operation when all of wind farms in Jeju island are disconnected from the Jeju power grid instantaneously on the rated power output. With the comparison of these results, it is useful for analyzing the power quality of Jeju power system versus wind power generation.

  • PDF

독립형 태양광 가로등 통합제어기 개발 (Development of a stand-alone solar street light controller integrated)

  • 김희철
    • 한국전자통신학회논문지
    • /
    • 제9권6호
    • /
    • pp.641-647
    • /
    • 2014
  • 독립형 태양광발전시스템은 배전선로와 계통 연계되지 않고 독립적으로 운영된다는 장점이 있어 시공설비가 간단하고 비용이 적게 드는 장점이 있지만 MPPT를 포함한 컨버터와 생산된 에너지를 배터리에 저장하기 위한 충전회로 및 배터리 매니징 회로가 요구된다. 기존의 대체에너지분야의 이용은 복합발전의 형태보다는 하나의 발전 형태를 주로 채택하고 있으나 태양광/풍력 복합발전시스템을 최적설계하고 배터리능력을 향상시켜 설치가격을 합리화 할 수 있는 통합형 제어시스템이 필요하다.

태양광 발전설비의 침수 시 설비영향 및 전기적 안전성 평가 (An Assessment on Effect of Facility and Electrical Safety During the Flooding of the Photovoltaic Power System)

  • 박찬엄;정진수;한운기;임현성;송영상
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.38-44
    • /
    • 2014
  • The photovoltaic power system is performing power generation by being installed in outdoors. Therefore it has the characteristics affected by environmental factors. In particular, if the solar power generation facility connected to the grid, the power can be generated continuously in a state of being secured operating voltage of the inverter and solar irradiation. In that case, if an abnormal situation such as flooding or heavy rains has occur, the possibility of electric shock or damage of facilities due to current leakage or a floating matters is present. In this paper, we performed electrical safety assessment about the connection part, junction box and cable of the solar module when the solar power system was flooded. we also assessed whether or not the leakage current is occurred in case of the cable was damaged. As a result, in case of the leakage current is large, we can be known that it is the risk of electric shock as well as cause of inverter damage.

다수 BESS의 SOC Balancing을 고려한 퍼지 드룹 제어 (Fuzzy Droop Control considering SOC Balancing of BESSs)

  • 한성근;유형준;김학만
    • 전기학회논문지
    • /
    • 제64권4호
    • /
    • pp.616-622
    • /
    • 2015
  • A microgrid which is composed of distributed generation systems, energy storage systems and loads is operated in the grid-connected mode and in the islanded mode. Especially, in the islanded mode, a microgrid should maintain frequency in the allowed range. The frequency is decided by a balance between power supply and power demand. In general, the frequency is controlled by using battery energy storage systems (BESSs) in the microgrid. Especially, droop control is applied to controlling BESSs in the microgrid. Meanwhile, over-charging and deep-discharging of BESS in operation and control cause life-shortening of batteries. In this paper, a fuzzy droop control is proposed to change droop gains adaptively by considering state of charge (SOC) of BESSs to improve the life cycle of the battery. The proposed fuzzy droop control adjusts droop gains based on SOC of BESSs in real time. In other to show the performance of the proposed fuzzy droop control, simulation based on Matlab/Simulink is performed. In addition, comparison of the convention droop control and the proposed fuzzy droop control is also performed.