• 제목/요약/키워드: Grid connected

검색결과 1,223건 처리시간 0.039초

Improved Decoupled Control and Islanding Detection of Inverter-Based Distribution in Multibus Microgrid Systems

  • Pinto, Smitha Joyce;Panda, Gayadhar
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1526-1540
    • /
    • 2016
  • This work mainly discusses an accurate and fast islanding detection based on fractional wavelet packet transform (FRWPT)for multibus microgrid systems. The proposed protection scheme uses combined desirable features retrieved from discrete fractional Fourier transform (FRFT) and wavelet packet transform (WPT) techniques, which provides precise time-frequency information on minute perturbation signals introduced in the system. Moreover, this study focuses on the design of decoupling control with a distributed controller based on state feedback for the efficient operation of microgrid systems that are transitioning from the grid-connected mode to the islanded mode. An IEEE 9-bus test system with inverter based distributed generation (DG) units is considered for islanding assessment and smooth operation. Finally, tracking errors are greatly reduced with stability improvement based on the proposed controller. FRWPT based islanding detection is demonstrated via a time domain simulation of the system. Simulated results show an improvement in system stability with the application of the proposed controller and accurate islanding detection based on the FRWPT technique in comparison with the results obtained by applying the wavelet transform (WT) and WPT.

개선된 AFD기법의 모델링 및 분석 (Modeling and Analysis of Modified Active Frequency Drift Method)

  • 안진웅;유권종;최익;최주엽;이기옥
    • 전력전자학회논문지
    • /
    • 제16권2호
    • /
    • pp.145-151
    • /
    • 2011
  • 본 논문은 신 재생에너지원 중 태양광을 이용한 계통연계형 PV PCS의 단독운전 검출 성능을 극대화하고, 출력 전력의 품질 악화를 최소화 할 수 있는 개선된 능동 주파수 변이기법의 외란의 크기를 모델링, 시뮬레이션 및 실험을 통하여 검증하고, 이를 근거로 계통 보호 협조 및 안전을 위한 개선된 능동적 주파수 변이기법의 타당성을 검증하고자 한다.

계통연계형 태양광-풍력-축전지 하이브리드 분산전원 시스템 개발 (Development of a Grid-connected PV-WT-BESS Hybrid Distributed Generation System)

  • 전진홍;조창희;김슬기;안종보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.517-518
    • /
    • 2006
  • 본 논문은 태양광과 풍력, 축전지 시스템으로 구성된 계통연계형 복합 분산전원 시스템의 구성과 실험 결과를 제시한다. 본 논문에서 제시하고자하는 계통연계형 태양광-풍력-축전지 복합 분산전원 시스템은 태양광 발전 시스템과 풍력 발전 시스템을 에너지원으로 사용하였으며 에너지 저장장치로는 축전지 시스템을 사용하였다. 태앙광 발전 시스템과 풍력 발전 시스템, 축전지 시스템은 모두 공통 직류단에 연결되어 있으며 계통과 연계운전을 위한 계통연계 인버터 시스템을 공통 직류단과 계통 연계점 사이에 적용하여 연계점의 출력을 제어하였다. 또한 분산전원 통합제어 시스템을 개발하여 전체 복합 분산전원 시스템의 출력과 각 모듈의 상태를 감시, 제어하는 기능을 하도록 하였다. 개발된 복합 분산전원 시스템에 전력 평준화 알고리즘을 적용한 실험 결과의 제시를 통해 제작된 시스템과 전력 평준화 알고리즘의 유용성을 검증하였다. 본 논문에서 제시된 복합 분산전원 시스템은 복수의 에너지원을 이용하므로 전력공급의 신뢰도를 향상시킬 수 있어 상용전력이 공급되지 않는 도서지역 등에 단독 운전용으로 적용이 가능하다.

  • PDF

HILS(Hardware In the Loop System)를 이용한 RTDS내 계통 연계형 태양광발전시스템 모델링기법 (RTDS based modeling technique of grid-connected photovoltaic generation system using HILS (Hardware In the Loop System))

  • 이효근;김상용;박상수;장성재;김경훈;서효룡;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1094_1095
    • /
    • 2009
  • 최근 분산전원 시스템들이 가정이나 공공기관 등에 많이 설치되면서 계통에 많은 문제점을 일으키고 있다. 이러한 문제점을 연구하기 위해서는 계통 등의 실제 시스템을 설치하여 실험을 하여야 하는데 학교 연구실 입장에서는 실제 시스템을 설치하여 실험하는데 한계가 있다. 그러나 실시간 전력 계통 모의장치 (Real Time Digital Simulator)를 이용하여 실시간으로 시스템을 시뮬레이션 할 경우 다양한 알고리즘의 적용이 가능하고, 고장, 전력계통 과도현상 등 계통에 일어날 수 있는 여러 가지 상황을 손쉽게 고려해 보는 것이 가능하다. 본 논문에서는 RTDS 내 계통 연계형 태양광 발전시스템을 실제 시스템과 유사하게 모델링하고, 실제 DSP (Digital Signal Processor) 를 이용하여 시스템을 실시간으로 운전하는 HILS (Hardware In the Loop System) 시스템을 구성하였다.

  • PDF

가스터빈 동기기 통합형 기동 및 여자시스템 개발 (Development of Integrated Start-up and Excitation System for Gas Turbine Synchronous Generator)

  • 류호선;차한주
    • 전기학회논문지P
    • /
    • 제63권3호
    • /
    • pp.183-188
    • /
    • 2014
  • Power conversion systems used in large gas turbine power plant can be divided into two main part. Because of the initial start-up characteristic of the gas turbine combustor, the gas turbine must be accelerated by starting device(LCI : Load Commutated Inverter) up to 10%~20% of rated speed to ignite it. In addition, the ECS(Excitation Control system) is used to control the rotor field current and reactive power in grid-connected synchronous generator. These two large power conversion systems are located in the same space(container) because of coordination control. Recently, many manufactures develop high speed controller based on function block available in the LCI and ECS with the newest power semiconductor. We also developed high speed controller based on function block to be using these two system and it meets the international standard IEC61131 as using real-time OS(VxWorks) and ISaGRAF. In order to install easily these systems at power plant, main controller, special module and IO module are used with high speed communication line other than electric wire line. Before initial product is installed on the site, prototype is produced and tests are conducted for it. The performance results of Integrated controller and application program(SFC, ECS) were described in this paper. The test results will be considered as the important resources for the application in future.

태양광발전시스템의 장기운전에 의한 성능변화 분석 (Performance Analysis of long term operation for photovoltaic system)

  • 김의환;김정삼
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.110.1-110.1
    • /
    • 2011
  • This study analyzed the performance of long term operation photovoltaic system The 50 kWp grid connected photovoltaic system which was installed at KEPRI site in 1999 has been operated more than 12 years. In order to acquire long term operation characteristics of medium size photovoltaic system, the operation test data related on power generation electricity and capacity factor of 50 kWp system, which have been collected since 1999, were analysed. From the analysing results, 57.7 MWh in annual power generation electricity of 50 kWp photovoltaic system in 1999 has been decreased 49.1 MWh in 2005 and reached 38.0 MWh in 2010. In addition to, the capacity factor of 50 kWp photovoltaic system also showed 13.2 % in 1999, 11.2% in 2005 and finally reached 8.8% in 2011. The operation test data showed a trend of decreasing of generation electricity and capacity factor during the 12 years operation time and we guessed that was caused by solar cell performance degradation and decreasing of PCS system efficiency.

  • PDF

태양광발전시스템의 장기운전에 의한 성능특성 분석 (The Long-term Operating Evaluation of the Grid Connected Photovoltaic System)

  • 김의환;강승원;김재언
    • 신재생에너지
    • /
    • 제7권2호
    • /
    • pp.28-35
    • /
    • 2011
  • Recently, photovoltaic systems have been devolved into much larger systems up to MW-scale. Photovoltaic industry participants give their focus on power generation capability of photovoltaic modules because their benefits can be decided from the amount of generation. The information on long-term performance change of photovoltaic modules helps to estimate the amount of power generation and evaluate the economic cost-benefits. Long-term performance of a PV system has been analyzed with operation data for 12 years from 1999 to 2010. In the first year, the amount of yearly power generation was 57.7 MWh with 13.2% capacity factor. In 2007, the amount of yearly generation was 44.3 MWh with 10.14% capacity factor, and in 2010, the amount was decreased down to 38.1 MWh with 8.7% capacity factor. The result means that long-term capacity factor has been 4.5% decreased for 12 years and that the amount of generation has been decreased 34.0% for 12 years which is 2.8 % per year. The latter capacity factor has been decreased faster than 0.20%, the average rate for 10 years. The performance decrease of the PV system is meant to be accelerated. The decrease of performance and utilization is due to aged deterioration of photovoltaic modules and lowering conversion efficiency of PCS.

출력변동 저감 및 출력범위 예측 향상을 위한 풍력-연료전지 하이브리드 시스템의 운영방법 (Operation Scheme to Regulate the Active Power Output and to Improve the Forecasting of Output Range in Wind Turbine and Fuel-Cell Hybrid System)

  • 김윤성;문대성;원동준
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.531-538
    • /
    • 2009
  • The paper deals with an operation scheme to improve the forecasting of output range and to regulate the active power output of the hybrid system consisting of a doubly fed induction generator (DFIG) and a fuel-cell. The power output of the wind turbine fluctuates as the wind speed varies and the slip power between the rotor circuit and power converter varies as the rotor speed change. The power fluctuation of a DFIG makes its operation difficult when a DFIG is connected to grid. A fuel cell system can be individually operated and adjusted output power, hence the wind turbine and fuel cell hybrid system can overcome power fluctuation by using a fuel-cell power control. In this paper, a fuel-cell is performed to regulate the active power output in comparison with the regulated active power output of a DFIG. And it also improves the forecasting of output range. Based on PSCAD/EMTDC tools, a DFIG and a proton exchange membrane fuel cell(PEMFC) is simulated and the dynamics of the output power in hybrid system are investigated.

A Feasibility Design of PEMFC Parallel Operation for a Fuel Cell Generation System

  • Kang, Hyun-Soo;Choe, Gyu-Yeong;Lee, Byoung-Kuk;Hur, Jin
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.408-421
    • /
    • 2008
  • In this paper, the parallel operation for a FC generation system is introduced and designed in order to increase the capacity for the distributed generation of a proton exchange membrane fuel cell (PEMFC) system. The equipment is the type that is used by parallel operated PEMFC generation systems which have two PEMFC systems, two dc/dc boost converters with shared dc link, and a grid-connected dc/ac inverter for embedded generation. The system requirement for the purpose of parallel operated generation using PEMFC system is also described. Aspects related to the mechanical (MBOP) and electrical (EBOP) component, size, and system complexity of the distributed generation system, it is explained in order to design an optimal distributed generation system using PEMFC. The optimal controller design for the parallel operation of the converter is suggested and informative simulations and experimental results are provided.

Probabilistic Evaluation of Voltage Quality on Distribution System Containing Distributed Generation and Electric Vehicle Charging Load

  • CHEN, Wei;YAN, Hongqiang;PEI, Xiping
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1743-1753
    • /
    • 2017
  • Since there are multiple random variables in the probabilistic load flow (PLF) calculation of distribution system containing distributed generation (DG) and electric vehicle charging load (EVCL), a Monte Carlo method based on composite sampling method is put forward according to the existing simple random sampling Monte Carlo simulation method (SRS-MCSM) to perform probabilistic assessment analysis of voltage quality of distribution system containing DG and EVCL. This method considers not only the randomness of wind speed and light intensity as well as the uncertainty of basic load and EVCL, but also other stochastic disturbances, such as the failure rate of the transmission line. According to the different characteristics of random factors, different sampling methods are applied. Simulation results on IEEE9 bus system and IEEE34 bus system demonstrates the validity, accuracy, rapidity and practicability of the proposed method. In contrast to the SRS-MCSM, the proposed method is of higher computational efficiency and better simulation accuracy. The variation of nodal voltages for distribution system before and after connecting DG and EVCL is compared and analyzed, especially the voltage fluctuation of the grid-connected point of DG and EVCL.