• Title/Summary/Keyword: Grid Size Control

Search Result 99, Processing Time 0.024 seconds

Environmental Cooperation Among East Asian Countries to Reduce Chinese Air Pollution (중국의 대기오염 배출 저감을 위한 한·중·일 에너지, 환경협력 방안)

  • Kim, Jeong-In
    • Environmental and Resource Economics Review
    • /
    • v.10 no.4
    • /
    • pp.591-617
    • /
    • 2001
  • For the past years, there had been some environmental cooperation among East Asian countries to reduce air pollution emissions from China. However, the progress of cooperation has been under developed because of lacking financial support, poor design of planning, and weak economic incentives for the industries. In this paper, some practical approaches have been suggested. First, electric trade to make Asian Grid among countries will be good alternatives for the fossil fuel, such as coal, for China. Secondly, natural gas pipeline from West China to Siberian pipeline would change the whole energy mix in this area around 2010, Therefore, it is very promising area for the energy industries to involve in gas project and get rid of many institutional barriers from China. Lastly, environmental industry is growing fast in East Asian. In China, waste treatment and management, air pollution control, and water quality management are some promising areas for the future. Hence it is desirable for Korea, Japan and China to make a eco-fund or company to boost up environmental technology as well as environmental market size.

  • PDF

3kW multi-string photovoltaic inverter design and simulation (3kW 멀티스트링 태양광 인버터 설계 및 시뮬레이션)

  • Lee, Jong-In;Yu, Beyng-Gyu;Yu, Gwen-Jong;Kim, Heung-Geun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.371-376
    • /
    • 2009
  • The Power Conditioning System is Power Transfer System which make array DC current to the Grid sinusoidal current. These are Low Frequency Transformer Inverter Type, High Frequency Transformer Inverter Type and Transformer-less Type. Low Frequency Transformer Type has a Excellent Isolation property, but doesn't have competitiveness in Size and Cost. Also High Frequency Transformer Type has a good Isolation property but there are many steps in Power transfer Switching. Nowadays, Transformer-less Type inverter change a transformer to DC/DC Converter which is small and cost effective. In this paper shown the DC/DC Converter Transformer-less Type multi-string inverter design and simulation. The Control Algorithm will be introduced and Simulation was accomplished.

  • PDF

Design of a 3DOF motion capture system for HMD using micro gyroscopes

  • Song, Jin-Woo;Chung, Hak-Young;Park, Chan-Gook;Lee, Jang-Gyu;Kang, Tae-Sam;Park, Kyu-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.64.2-64
    • /
    • 2001
  • In this paper, fabricated is a motion capture and attitude detection system for Head Mounted Display HMD composed of three low-price and low-grade micro gyroscopes and a micro-controller, To calculate attitude of a body, modified INS algorithm is used. Because the micro gyroscope has much bias drift error, scale factor error, and run-to-run bias error, the motion of a body can not be measured exactly if the general INS algorithm and micro gyroscopes are used. To reduce the errors, three accelerometers can be used. In this case, however, the size and power consumption become too large to use in HMD system. The modified INS algorithm use the grid map and the characteristics of the human motions.

  • PDF

A Two-Phase Interleaved Single-Stage Isolated Boost-Half-Bridge AC-DC Converter using a Transformer with Flux Cancellation

  • Naradhipa, Adhistira M.;Kang, Suhan;Choi, Sewan
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.153-155
    • /
    • 2019
  • This paper proposes a two-phase interleaved bridgeless single-stage ac-dc converter with magnetic integration that can achieve CCM power factor correction without input current sensing. All switches achieve ZVS turn-on and all diodes achieve ZCS turn-on for the whole grid cycle. SDAB-based modulation strategy is applied which results in simple power control and wide range output voltage. A flux cancellation method to integrate the interleaved transformer is firstly proposed in this paper to reduce the core size and loss. Experimental results on a 1.7-kW, 50kHz prototype are given to verify the principle and advantages of the proposed ac-dc converter.

  • PDF

STATCOM Helps to Guarantee a Stable System

  • Andersen, B.R;Gemmell, B.D.;Horwill, C.;Hanson, D.J.
    • Journal of Power Electronics
    • /
    • v.1 no.2
    • /
    • pp.65-70
    • /
    • 2001
  • Transmission System Operators are governed by operational security standards that are applied in real time. During system disturbances, the System Operators must rely on the installed protection and control equipment, prior to human intervention. New power electronic solutions bring rapid and repeatable responses to disturbances, which will help System Operators to guarantee a stable system. Last year, Alstom completed the world's first competitively bid STATCOM to support the voltage on National Grid's 400kV network that supplies London and the Southeast from the north of the UK. It is rated ${\pm}75MVAr$ and forms part of a Static Var System (SVS) with a total rating of 0 to 225MVAr. This paper will describe the reasons for its size, location, its chain-link configuration and give examples of its operating performance. The paper will also describe the features that allow this STATCOM to deliver much more than reactive compensation in support of a wider transmission service objective, as system conditions require.

  • PDF

Implementation of Small-Scale Wind Turbine Monitoring and Control System Based on Wireless Sensor Network (무선 센서 네트워크 기반 소규모 풍력발전기 모니터링 및 제어 시스템 구현)

  • Kim, Do-Young;Kim, Young-Chon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.9
    • /
    • pp.1808-1818
    • /
    • 2015
  • Recently, the wind power has experienced great attentions and growths among many renewable energy sources. To increase the power generation performance and economic feasibility, the size of wind turbine (WT) is getting bigger and most of wind power plants are being constructed on offshore. Therefore, the maintenance cost is relatively high because boats or helicopters are needed operators to reach the WT. In order to combat this kind of problem, remote monitoring and control system for the WT is needed. In this paper, the small-scale WT monitoring and control system is implemented using wireless sensor network technologies. To do this, sensor devices are installed to measure and send the WT status and control device is installed to receive control message for specific operation. The WT is managed by control center through graphic user interface (GUI) based monitoring and control software. Also, smart device based web-program is implemented to make the remote monitoring of the WT possible even though operators are not in control room.

The Effect of Form Factors and Control Types on Unsorted List Search for Full Touch Phone

  • Lee, Jong-Kee;Park, Jae-Kyu;Kim, Jun-Young;Choe, Jae-Ho;Jung, Eui-S.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.309-317
    • /
    • 2012
  • Objective: The aim of this paper is to inquire into the influences form factors and control types affect a search time and comfort at list menu of full touch phone. Background: Various studies have been proceeded that are related to the optimum touch area for enhancing usability of control and legibility in mobile touch device. In the environment of list menu which is widely used to provide various information effectively, however, not only comprehensive consideration for legibility and control is to be seek but also research for control type which is to scroll a list. Method: This study executed form factor experiment to inquire into the influence that font size, height of row and fixed area affect searching time and comfort in the while information processing even if the information on the list is unsorted in alphabetical order. Among the result of form factor experiment, control type experiment was executed by selecting shortest performance time, highest legibility comfort and control comfort. Control type experiment was implemented to figure out the influence which existing flicking type, scrolling bar type, newly established button page type and button raw types affect performance time and subjective comfort depending on location of the information. Results: Font size 12pt, height of row 7mm and fixed area 15mm was shortest performance time and got highest comfort and legibility score in form factor experiment. A Button page which was newly proposed type was shortest performance time and got highest comprehensive comfort in control type experiment. Conclusion: Form factor experiment showed similar results with the study through reading a long passage of character or controlling a grid icon type. However, height of row turned out to affect not only touch area for control but also legibility by ruling space between the lines. Button page type which was newly proposed showed shortest performance time and got highest comprehensive comfort. Because Button page type needs few finger movements than other control types and implements search in the fixed form, unlikely other type which list keeps moving. Application: This study should be applied in deciding form factors and control type for scroll when designing a list menu of full touch phone.

Inspection method of BGA Ball Using 5-step Ring Illumination (5층 링 조명에 의한 BGA 볼의 검사 방법)

  • Kim, Jong Hyeong;Nguyen, Chanh D.Tr.
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.12
    • /
    • pp.1115-1121
    • /
    • 2015
  • Fast inspection of solder ball bumps in ball grid array (BGA) is an important issue in the flip chip bonding technology. Particularly, semiconductor industry has required faster and more accurate inspection of micron-size solder bumps in flip chip bonding, as the density of balls increase dramatically. In this paper, we describe an inspection approach of BGA balls by using 5-step ring illumination device and normalized cross-correlation (NCC) method. The images of BGA ball by the illumination device show unique and distinguishable characteristic contours by their 3-D shapes, which are called as "iso-slope contours". Template images of reference ball samples can be produced artificially by the hybrid reflectance model and 3D data of balls. NCC values between test and template samples are very robust and reliable under well-structured condition. The 200 samples on real wafer are tested and show good practical feasibility of the proposed method.

Shape Recognition of a BGA Ball using Ring Illumination (링 조명에 의한 BGA 볼의 3차원 형상 인식)

  • Kim, Jong Hyeong;Nguyen, Chanh D.Tr.
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.960-967
    • /
    • 2013
  • Shape recognition of solder ball bumps in a BGA (Ball Grid Array) is an important issue in flip chip bonding technology. In particular, the semiconductor industry has required faster and more accurate inspection of micron-size solder bumps in flip chip bonding as the density of balls has increased dramatically. The difficulty of this issue comes from specular reflection on the metal ball. Shape recognition of a metal ball is a very realproblem for computer vision systems. Specular reflection of the metal ball appears, disappears, or changes its image abruptly due to tiny movementson behalf of the viewer. This paper presents a practical shape recognition method for three dimensional (3-D) inspection of a BGA using a 5-step ring illumination device. When the ring light illuminates the balls, distinctive specularity images of the balls, which are referred to as "iso-slope contours" in this paper, are shown. By using a mathematical reflectance model, we can drive the 3-D shape information of the ball in aquantitative manner. The experimental results show the usefulness of the method for industrial application in terms of time and accuracy.

Development of Operation Control and AC/DC Conversion Integrated Device for DC Power Application of Small Wind Power Generation System (소형 풍력발전시스템의 직류전원 적용을 위한 운전제어 및 AC/DC변환 통합장치 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.3
    • /
    • pp.179-184
    • /
    • 2019
  • In many countries, such as developing countries where electricity is scarce, small wind turbines in the form of Off Grid are an effective solution to solve power supply problems. In some countries, the expansion of power systems and the decline of electricity-intensive areas have led to the use of small wind power in urban road lighting, mobile communications base stations, aquaculture and seawater desalination. With this change, the size of the small wind power industry is expected to have greater potential than large-scale wind power. In the case of small wind power generators, the generator is controlled at a variable speed, and the voltage and current generated by the generator have many harmonic components. To solve this problem, the AC to DC converter to be studied in this paper is a three-phase step-up type converter with a single switch. The inductor current is controlled in discontinuous mode, and has a characteristic of having a unit power factor by eliminating the harmonic of the input current. The proposed converter is composed of LCL filter and three phase rectification boost converter at the input stage and a single phase full bridge for grid connection. It is a control system with energy storage system(ESS) that the system stabilization can be pursued against the electric power.