• 제목/요약/키워드: Grid Connected System

검색결과 846건 처리시간 0.045초

분산 발전 시스템에서 계통연계 인버터의 매끄러운 모드 전환 (Grid Connected Inverter of ESS for Seamless mode Transition)

  • 홍창표;김학원;조관열
    • 전력전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.364-372
    • /
    • 2016
  • In this paper, a voltage controller for the seamless transition of a grid-connected inverter for ESS is proposed. The single-phase inverter is operated as a current controller when the grid is connected and as a voltage controller in the stand-alone mode when the grid is disconnected. Generally, in the case of grid recovery, the overcurrent may flow into the system because of the mismatch phase between the inverter output and grid voltages. The proposed controller resolves the overcurrent problem through phase delay problems with initial value feed-forward control of the integrator when the grid voltage is restored. The effects of the control method are simulated through PSIM, and the usefulness of the control method is verified through experiments.

A Virtual RLC Active Damping Method for LCL-Type Grid-Connected Inverters

  • Geng, Yiwen;Qi, Yawen;Zheng, Pengfei;Guo, Fei;Gao, Xiang
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1555-1566
    • /
    • 2018
  • Proportional capacitor-current-feedback active damping (AD) is a common damping method for the resonance of LCL-type grid-connected inverters. Proportional capacitor-current-feedback AD behaves as a virtual resistor in parallel with the capacitor. However, the existence of delay in the actual control system causes impedance in the virtual resistor. Impedance is manifested as negative resistance when the resonance frequency exceeds one-sixth of the sampling frequency ($f_s/6$). As a result, the damping effect disappears. To extend the system damping region, this study proposes a virtual resistor-inductor-capacitor (RLC) AD method. The method is implemented by feeding the filter capacitor current passing through a band-pass filter, which functions as a virtual RLC in parallel with the filter capacitor to achieve positive resistance in a wide resonance frequency range. A combination of Nyquist theory and system close-loop pole-zero diagrams is used for damping parameter design to obtain optimal damping parameters. An experiment is performed with a 10 kW grid-connected inverter. The effectiveness of the proposed AD method and the system's robustness against grid impedance variation are demonstrated.

Stability Improvement of Distributed Power Generation Systems with an LCL-Filter Using Gain Scheduling Based on Grid Impedance Estimations

  • Choi, Dae-Keun;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.599-605
    • /
    • 2011
  • This paper proposes a gain scheduling method that improves the stability of grid-connected systems employing an LCL-filter. The method adjusts the current controller gain through an estimation of the grid impedance in order to reduce the resonance that occurs when using an LCL-filter to reduce switching harmonics. An LCL-filter typically has a frequency spectrum with a resonance peak. A change of the grid-impedance results in a change to the resonant frequency. Therefore an LCL-filter needs a damping method that is applicable when changing the grid impedance for stable system control. The proposed method instantaneously estimates the grid impedance and observes the resonant frequency at the same time. Consequently, the proposed method adjusts the current controller gain using a gain scheduling method in order to guarantee current controller stability when a change in the resonant frequency occurs. The effectiveness of the proposed method has been verified by simulations and experimental results.

BPF-based Grid Voltage Feedforward Control of Grid-connected Converters for Improving Robust Stability

  • Yang, Shude;Tong, Xiangqian;Yin, Jun;Wang, Haiyan;Deng, Yaping;Liu, Le
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.432-441
    • /
    • 2017
  • Grid voltage feedforward is extensively used for controlling grid-connected converters. However, the conventional voltage feedforward control reduces the stability margins of the converter connected to a high-impedance grid. The effect mechanism of voltage feedforward on the grid-connected converter control under high-inductive conditions of the grid impedance is clearly explained in this study using the equivalent transformations of control block diagrams. Results show that the delay produced by the digital control is the root cause of this effect. An improved voltage feedforward strategy, in which a bandpass filter (BPF) is introduced into the feedforward path, is proposed to strengthen the converter's robust stability against grid impedance variations. The selection method of the BPF's bandwidth is also provided considering the tradeoff between the response speed to the grid voltage sag and the system's robust stability. The converter can work stably over a wide range of the grid impedance through the proposed approach. Simulation and experimental results fully verify the effectiveness of the BPF-based voltage feedforward strategy.

계통연계 태양광 발전시스템의 운전특성분석 (An Analysis of the Operation Characteristics of a Grid-Connected Photovoltaic Power Generation System)

  • 황인호;정승주;성세진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.1945-1947
    • /
    • 1997
  • In this paper, a characteristics analysis of the grid-connected photovoltaic power generation system which uses the simulation method of PV array is reported. The control method of DC/AC power conversion were suggested to establish the basic application technology of photovoltaic systems. The results of the demonstration test of a 3kW grid-connected PV system show that the system utilization rate is 17.6% and the system efficiency is 8.9%.

  • PDF

Step 가변형 MPPT 제어기법과 DVR을 적용한 계통연계형 태양광 발전 시스템 (Grid-Connected Photovoltaic System Applying the Step Variable MPPT Control and DVR)

  • 이용식;정성원;김재현
    • 조명전기설비학회논문지
    • /
    • 제26권8호
    • /
    • pp.42-49
    • /
    • 2012
  • Grid-connected photovoltaic generator system requires high performance PCS(Power Conditioning System) according to the standard of 'Distributed Generation Grid-Connected Technology Standards'. This paper presents the MPPT control method which improves output efficiency through fast tracking to the maximum power point of PV and a reduced self-excited vibration. Secondly, in this paper DVR function was applied to PCS to compensate the voltage sag frequently happening for a power system. The proposed PCS control is analyzed and compared to conventional PCS operating characteristic, the various insolation and loads, and voltage sag condition through PSIM tool. It proves the utility.

풍력발전 계통연계 변압기의 결선에 따른 배전계통의 고장전류에 관한 연구 (A Study on the Fault Current of Distribution System according to Connection of Wind Turbine Generation Grid-Connected Transformer)

  • 안해준;노경수;김현구
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.369-371
    • /
    • 2007
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, generator rotor speed, generator terminal current and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF

계통연계형 PV 시스템의 주파수 변동에 의한 새로운 단독운전 검출기법 (Novel Islanding Detection Method using Frequency Drift for Grid-connected PV System)

  • 은석준;최종우;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 추계학술대회 논문집
    • /
    • pp.133-137
    • /
    • 2004
  • PV system's islanding occurs when the uitilty grid is removed but local sources continue to operate and provide power to local loads. Islanding is one of the serious problems m an electric power system connected with dispersed power sources. Also, this can present safety hazards and the possibility of damage to other electric equipments. If the real and reactive power of RLC load and PV system are closely matched, islanding detection by passive methods becomes difficult. Novel islanding detection method using frequency drift is proposed for grid-connected PV system.

  • PDF

A 15kW Grid-Connected Battery Charging and Discharging System with AC Regeneration Function

  • Youn, Sun-Jae;Kim, Jun-Gu;Kim, Jae-Hyung;Won, Chung-Yuen;Na, Jong-Kuk
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.491-493
    • /
    • 2011
  • In this paper, a 15kW grid-connected battery charging and discharging system was proposed. AC regenerative device which consisted of an inverter using IGBTs and LCL filter transferred surplus power to grid. Phase locked loop(PLL) was used to resolve three-phase unbalance. AC regeneration function is able to improve the rate of energy use and the cost savings of energy is expected.

  • PDF

New Control Strategy for Three-Phase Grid-Connected LCL Inverters without a Phase-Locked Loop

  • Zhou, Lin;Yang, Ming;Liu, Qiang;Guo, Ke
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.487-496
    • /
    • 2013
  • The three-phase synchronous reference frame phase-locked loop (SRF-PLL) is widely used for synchronization applications in power systems. In this paper, a new control strategy for three-phase grid-connected LCL inverters without a PLL is presented. According to the new strategy, a current reference can be generated by using the instantaneous power control scheme and the proposed positive-sequence voltage detector. Through theoretical analysis, it is indicated that a high-quality grid current can be produced by introducing the new control strategy. In addition, a kind of independent control for reactive power can be achieved under unbalanced and distorted grid conditions. Finally, the excellent performance of the proposed control strategy is validated by means of simulation and experimental results.