• Title/Summary/Keyword: Green Laser

Search Result 200, Processing Time 0.025 seconds

고온고압처리에 따른 천연갈색다이아몬드의 광학특성분석

  • Seo, Jin-Gyo;An, Yong-Gil;Park, Jong-Wan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.52-52
    • /
    • 2010
  • 본 연구에서 우리는 HPHT 처리 전 FT-IR spectrometer를 이용한 사전분석을 통해 type Ia brown 다이아몬드를 IaA, IaB, IaAB (A>B), IaAB (A=B), IaAB (A$1700-1800^{\circ}C$, 5 GPa에서 다이아몬드가 흑연화 되지 않는 범위 하에 HPHT처리를 시행하였다. 자외선-가시광선 분광분석기(UV-Vis Spectrometer, Shimadzu UV 3101PC)를 사용하여 350~800 nm에서의 가시광선 범위를 0.1nm의 분해능으로 투과(Transmittance) 모드로 측정하였고, 퓨리에 변환 적외선 분광분석기(FT-IR spectrometer, Jasco-4100)을 사용하여 $400{\sim}6000cm^{-1}$의 범위에서 $4cm^{-1}$ 의 분해능으로 흡수(Absorption) 모드로 측정한 후 HPHT 처리 전후를 비교 분석하였다. 또한 광루미네선스(Photoluminescence) 분석은 325 nm He-Cd laser를 광원으로 한(PL, Spectra-pro 2150i, Spectra-pro 2300i micro-spectrometer) 및 532 nm green laser를 광원으로 한(PL, SAS 2000)를 사용하여 각각 350~600 nm, 550~1100 nm의 범위에서 0.1nm step으로 측정하여 HPHT 처리전과 후를 비교 분석하였다. HPHT처리 후 모든 시료는 N3 center (415.4 nm), H4 center (496.4nm) 및 platelet와 연관된 ($1363\;cm^{-1}$)의 peak가 감소하였고, H3 center (503.2 nm)와 G-band가 증가하는 경향을 나타내었다. 또한 HPHT 처리 시 질소의 B집합보다 A집합이 더 감소하는 경향을 나타내었으며, A 또는 B집합의 파괴에서 발생된 질소 원자에 의해 질소의 interstitial center (594 nm)가 증가함을 알 수 있었다. HPHT 처리 후 모든 시료는 (N-V)- center가 생성됨을 확인 할 수 있었다. 결론적으로 본 연구를 통해 HPHT 처리를 통해 다이아몬드 내에 존재하는 질소결합관련 상태의 변화를 확인할 수 있었다.

  • PDF

Growth and Optical Property Characterization of KTP Crystal (KTP 단결정 성장 및 광학 특성에 관한 연구)

  • Lee, Seong-Guk;Kim, Yong-Hun;Ma, Dong-Jun;Han, Jae-Yong;Park, Seong-Su;Lee, Sang-Hak
    • Korean Journal of Materials Research
    • /
    • v.5 no.7
    • /
    • pp.781-785
    • /
    • 1995
  • from the $K_{6}$P$_4$ $O_{13}$ flux using a temperature cooling method. According to SHG outpower measurement, phase matching angle is $\theta$=90$^{\circ}$, $\Phi$=23.3$^{\circ}$and angular acceptance of $\Phi$ direction is about 2 degree, Deviation of phase matching angle due to index inhomogeneity in KTP crystal is 0.17 degree. A 20mW green laser was obtained with the combination of a intracavity Nd ; YAG and KTP crystal.

  • PDF

Photodynamic Inactivation of Moraxella catarrhalis (Moraxella catarrhalis의 광역학적 비활성화)

  • Hong, Seong-No;Kwon, Pil-Seung;Kim, Dae-Sik
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.1
    • /
    • pp.19-24
    • /
    • 2007
  • The aim of this study was to evaluate the bacterial effects of Moraxella catarrhalis in otitis media with effusion (OME) by photodynamic therapy (PDT). Bacterial suspensions (10000 CFU/mL) were prepared. The colony forming units (CFU) of Moraxella catarrhalis have been measured after an application of photogem plus 632 nm diode laser irradiation. One ml of the bacterial suspensions have been incubated in the dark for 3h with various concentrations of photogem ($0.625{\sim}5.0_{\mu}g/mL$) and then irradiated with 632 nm diode laser ($15J/cm^2$). After, the PDT Moraxella catarrhalis suspensions ($50{\mu}L$) were inoculated on chocolate agar plate and cultured in the dark at $37^{\circ}C$, 5% $CO_2$ condition for 18h. The colony forming units off the bacteria were measured. Also transmission electron microscopy (TEM) was employed to evaluate the effect of otitis media pathogens by PDT. The nucleus of Moraxella catarrhalis was stained using green fluorescent nucleic acid dye thiazole orange and the fluorescence intensity of the nucleus was measured by flow cytometry. The PDT was effective in killing Moraxella catarrhalis at the photogem dose of $5.0_{\mu}g/mL$, respectively, As assessed by flow cytometry analysis the fluorescence intensity of the nucleus got lower after PDT. TEM result appeared to able to cause damage to the bacterial membranes. On the basis of these findings, bacterial photodynamic therapy with photogem can be considered to be a promising new therapeutic approach for OME.

  • PDF

Photoluminescence of ZnGa2O4-xMx:Mn2+ (M=S, Se) Thin Films

  • Yi, Soung-Soo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.6
    • /
    • pp.13-16
    • /
    • 2003
  • Mn-doped $ZnGa_{2}O_{4}$:$Mn^{2+}$ (M=S, Se) thin film phosphors have been grown using a pulsed laser deposition technique under various growth conditions. The structural characterization carr~ed out on a series of $ZnGa_{2}O_{4}$:$Mn^{2+}$ (M=S, Se) films grown on MgO(l00) substrates usmg Zn-rich ceramic targets. Oxygen pressure was varied from 50 to 200 mTorr and Zn/Ga ratio was the function of oxygen pressure. XRD patterns showed that the lattice constants of the $ZnGa_{2}O_{4}$:$Mn^{2+}$ (M=S, Se) thin film decrease with the substitution of sulfur and selenium for the oxygen in the $ZnGa_2O_4$. Measurements of photoluminescence (PL) properties of $ZnGa_{2}O_{4}$:$Mn^{2+}$ (M=S, Se) thin films have indicated that MgO(100) is one of the most promised substrates for the growth of high quality $ZnGa_2O_{4-x}M_{x}$:$Mn^{2+}$ (M=S, Se) thin films. In particular, the incorporation of Sulfur or Selenium into $ZnGa_2O_4$ lattice could induce a remarkable increase in the intensity of PL. The increasing of green emission intensity was observed with $ZnGa_2O_{3.925}Se_{0.075}:$Mn^{2+}$ and $ZnGa_2O_{3.925}S_{0.05}$:$Mn^{2+}$ films, whose brightness was increased by a factor of 3.1 and 1.4 in comparison with that of $ZnGa_{2}O_{4}$:$Mn^{2+}$ films, respectively. These phosphors may promise for application to the flat panel displays.

Experimental Investigation of Concave and Convex Micro-Textures for Improving Anti-Adhesion Property of Cutting Tool in Dry Finish Cutting

  • Kang, Zhengyang;Fu, Yonghong;Chen, Yun;Ji, Jinghu;Fu, Hao;Wang, Shulin;Li, Rui
    • International Journal of Precision Engineering and Manufacturing-Green Technology
    • /
    • v.5 no.5
    • /
    • pp.583-591
    • /
    • 2018
  • Tool-chip adhesion impacts on cutting performance significantly, especially in finish cutting process. To promote cutting tools' anti-adhesion property, the concave micro-grooves texture (MGT) and convex volcano-like texture (VLT) were fabricated separately on lathe tools' rake faces by laser surface texturing (LST). Various orientations of MGT and different area densities (9% and 48%) and regions (partial and full) of VLT were considered in textured patterns designing. The following orthogonal cutting experiments, machining of aluminum alloy 5038, analyzed tools' performances including cutting force, cutting stability, chip shape, rake face adhesion and abrasion. It indicated that under dry finish cutting conditions, MGT contributed to cutting stability and low cutting forces, meanwhile friction and normal force reduced by around 15% and 10%, respectively with a weak correlation to the grooves' orientation. High density VLT tools, on the other hand, presented an obvious anti-adhesion property. A $5{\mu}m$ reduction of crater wear's depth can be observed on textured rake faces after long length cutting and textured rake faces presented half size of BUE regions comparing to the flat tool, however, once the texture morphologies were filled or worn, the anti-adhesion effect could be invalid. The bearing ratio curve was employed to analysis tool-chip contact and durability of textured surfaces contributing to a better understanding of anti-adhesion and enhanced durability of the textured tools.

Improved dentin disinfection by combining different-geometry rotary nickel-titanium files in preparing root canals

  • Bedier, Marwa M.;Hashem, Ahmed Abdel Rahman;Hassan, Yosra M.
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.4
    • /
    • pp.46.1-46.10
    • /
    • 2018
  • Objectives: This study was to evaluate the antibacterial effect of different instrumentation and irrigation techniques using confocal laser scanning microscopy (CLSM) after root canal inoculation with Enterococcus faecalis (E. faecalis). Materials and Methods: Mesiobuccal and mesiolingual canals of extracted mandibular molars were apically enlarged up to a size 25 hand K-file, then autoclaved and inoculated with E. faecalis. The samples were randomly divided into 4 main groups according to the system of instrumentation and irrigation: an XP-endo Shaper (XPS) combined with conventional irrigation (XPS/C) or an XP-endo Finisher (XPF) (XPS/XPF), and iRaCe combined with conventional irrigation (iRaCe/C) or combined with an XPF (iRaCe/XPF). A middle-third sample was taken from each group, and then the bacterial reduction was evaluated using CLSM at a depth of $50{\mu}m$ inside the dentinal tubules. The ratio of red fluorescence (dead cells) to green-and-red fluorescence (live and dead cells) represented the percentage of bacterial reduction. The data were then statistically analyzed using the Kruskal-Wallis test for comparisons across the groups and the Dunn test was used for pairwise comparisons. Results: The instrumentation and irrigation techniques had a significant effect on bacterial reduction (p < 0.05). The iRaCe/XPF group showed the strongest effect, followed by the XPS/XPF and XPS/C group, while the iRaCe/C group had the weakest effect. Conclusions: Combining iRaCe with XPF improved its bacterial reduction effect, while combining XPS with XPF did not yield a significant improvement in its ability to reduce bacteria at a depth of $50{\mu}m$ in the dentinal tubules.

Bio-hybrid dental implants prepared using stem cells with β-TCP-coated titanium and zirconia

  • Safi, Ihab Nabeel;Hussein, Basima Mohammed Ali;Al-Shammari, Ahmed Majeed
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.3
    • /
    • pp.242-257
    • /
    • 2022
  • Purpose: This study investigated periodontal ligament (PDL) restoration in osseointegrated implants using stem cells. Methods: Commercial pure titanium and zirconium oxide (zirconia) were coated with beta-tricalcium phosphate (β-TCP) using a long-pulse Nd:YAG laser (1,064 nm). Isolated bone marrow mesenchymal cells (BMMSCs) from rabbit tibia and femur, isolated PDL stem cells (PDLSCs) from the lower right incisor, and co-cultured BMMSCs and PDLSCs were tested for periostin markers using an immunofluorescent assay. Implants with 3D-engineered tissue were implanted into the lower right central incisors after extraction from rabbits. Forty implants (Ti or zirconia) were subdivided according to the duration of implantation (healing period: 45 or 90 days). Each subgroup (20 implants) was subdivided into 4 groups (without cells, PDLSC sheets, BMMSC sheets, and co-culture cell sheets). All groups underwent histological testing involving haematoxylin and eosin staining and immunohistochemistry, stereoscopic analysis to measure the PDL width, and field emission scanning electron microscopy (FESEM). The natural lower central incisors were used as controls. Results: The BMMSCs co-cultured with PDLSCs generated a well-formed PDL tissue that exhibited positive periostin expression. Histological analysis showed that the implantation of coated (Ti and zirconia) dental implants without a cell sheet resulted in a well-osseointegrated implant at both healing intervals, which was confirmed with FESEM analysis and negative periostin expression. The mesenchymal tissue structured from PDLSCs only or co-cultured (BMMSCs and PDLSCs) could form a natural periodontal tissue with no significant difference between Ti and zirconia implants, consequently forming a biohybrid dental implant. Green fluorescence for periostin was clearly detected around the biohybrid implants after 45 and 90 days. FESEM showed the invasion of PDL-like fibres perpendicular to the cementum of the bio-hybrid implants. Conclusions: β-TCP-coated (Ti and zirconia) implants generated periodontal tissue and formed biohybrid implants when mesenchymal-tissue-layered cell sheets were isolated from PDLSCs alone or co-cultured BMMSCs and PDLSCs.

Fabrication of a periodically poled MgO : $LiNbO_3$ ridge waveguide for a green laser generation (녹색 광 발진을 위한 주기적 분극 반전된 MgO : $LiNbO_3$ ridge waveguide 제작)

  • Yang, W.S.;Kwon, S.W.;Song, M.K.;Lee, H.M.;Kim, W.K.;Koo, K.H.;Yoon, D.H.;Lee, H.Y.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.17 no.4
    • /
    • pp.151-155
    • /
    • 2007
  • Quasi-phase-matched (QPM) second harmonic generation (SHG) waveguide devices for a green light generation were fabricated by a periodically patterned electrode on the +Z crystal surface and homogeneous LiCl solution using a 5 mol% MgO doped congruent z-cut lithium niobate crystals. Using selective chemical etching, we confirmed the periodic (${\sim}6.8{\mu}m$) domain inverted structure and measured SHG properties of fabricated periodically poled MgO : $LiNbO_3$ ridge-type waveguides.

The effect of photodynamic therapy on Aggregatibacter actinomycetemcomitans attached to surface-modified titanium

  • Cho, Kyungwon;Lee, Si Young;Chang, Beom-Seok;Um, Heung-Sik;Lee, Jae-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.2
    • /
    • pp.38-45
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the effect of photodynamic therapy (PDT) using erythrosine and a green light emitting diode (LED) light source on biofilms of Aggregatibacter actinomycetemcomitans attached to resorbable blasted media (RBM) and sandblasted, large-grit, acid-etched (SLA) titanium surfaces in vitro. Methods: RBM and SLA disks were subdivided into four groups, including one control group and three test groups (referred to as E0, E30, E60), in order to evaluate the effect of PDT on each surface. The E0 group was put into $500{\mu}L$ of $20{\mu}M$ erythrosine for 60 seconds without irradiation, the E30 group was put into erythrosine for 60 seconds and was then irradiated with a LED for 30 seconds, and the E60 group was put into erythrosine for 60 seconds and then irradiated with a LED for 60 seconds. After PDT, sonication was performed in order to detach the bacteria, the plates were incubated under anaerobic conditions on brucella blood agar plates for 72 hours at $37^{\circ}C$, and the number of colony-forming units (CFUs) was determined. Results: Significant differences were found between the control group and the E30 and E60 groups (P<0.05). A significantly lower quantity of CFU/mL was found in the E30 and E60 groups on both titanium disk surfaces. In confocal scanning laser microscopy images, increased bacterial death was observed when disks were irradiated for a longer period of time. Conclusions: These findings suggest that PDT using erythrosine and a green LED is effective in reducing the viability of A. actinomycetemcomitans attached to surface-modified titanium in vitro.

Color Filter Utilizing a Thin Film Etalon (박막형 에탈론 기반의 투과형 컬러필터)

  • Yoon, Yeo-Taek;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.4
    • /
    • pp.175-178
    • /
    • 2010
  • A transmission type color filter based on a thin film Ag-$SiO_2$-Ag etalon was proposed and realized in a quartz substrate. The device could acquire infrared suppressed transmission and wide effective area compared to costly e-beam lithography and laser interference lithography. The FDTD method was introduced to take into account the effect of the dispersion characteristics of the silver metal and the thickness thereof. Three different color filters were devised: The cavity length for the red, green and blue filters were 160 nm, 130 nm, and 100 nm respectively, with the metal layer unchanged at 25 nm. The observed center wavelengths were measured at 650 nm, 555 nm, and 480 nm for the red, green, and blue devices; the corresponding bandwidths were about 120 nm, 100 nm, and 120 nm; and the peak transmission for all was ~60%. Finally the relative transmission was measured to decline with the angle of the incident beam with the rate of 1%/degree.