• Title/Summary/Keyword: Green Air Conditioning

Search Result 102, Processing Time 0.022 seconds

A Study on the Material and Resource of Education Facilities in Green Building Certification Criteria (학교시설 친환경 인증사례를 통한 재료 및 자원항목 연구)

  • Kwag, Moon-Geun;Choi, Chang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.2
    • /
    • pp.104-111
    • /
    • 2010
  • To promote environmentally responsible architectural practice, many nations have established their own Green Building Certification system. Until 2007, 138 Education facilities acquired certification but many people don't fully understand each item of Green building Certification Criteria yet. The purpose of this study is to analyze 40 certified Education facilities and to find the reasons why they had acquired low scores and high scores. These scores lead us to propose a way that each contents the efficient approaches and alternative visions of Education facilities. Because the part of material and resource is initial of the projects, this study focuses on it and aims to pick out the items requiring improvement for the Education facilities. We expect to be helpful for the next design works through result of this thorough study.

An Analysis of the Energy Saving Effect Through the Retrofit and the Optimal Operation for HVAC Systems (공조설비 운전방법 및 시설개선을 통한 에너지절약 효과분석)

  • Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.343-350
    • /
    • 2012
  • The major goal of building energy management is to minimize the energy consumption while maintaining the comfortable environment condition. Nowadays building energy management to save HVAC energy and so on is the most critical issue for existing building service branch with high efficiency equipments and their optimal operation. The effects on the building energy savings of the building equipment retrofit and the improvement of its operation method, especially in the field of HVAC system, were analyzed in this study for domestic small and/or medium sized buildings. Over 8.8% of energy saving was achieved compared withe total energy consumption in commercial building. These results could be used for reasonable maintenance and efficient management of the various building service equipments and related systems.

A Study on the Ecology of Education Facilities in Green Building Certification Criteria (학교시설 친환경건축물인증 사례를 통한 생태환경 평가항목 분석)

  • Kwon, Young-Cheol;Choi, Chang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.2
    • /
    • pp.112-121
    • /
    • 2010
  • With the global climate changes, a global concerns on building energy uses and $CO_2$ emission to improve the environment friendly has been increasingly growing. To achieve this global goal, the Korea government has been seeking an environment-friendly and sustainable development. As the results, the government started Green Building Certification Criteria system. however the certificate system has still been at the basic stage. To upgrade and advance it's level, it's necessary to identify the current status. This study aims to pick out the items requiring improvement for the Ecology of Education Facilities. We expect that the results of this study will be helpful for the next design works of certificate system.

A Study on the Characteristics an Azeotropic Mixture Combined with CF_{3}I and a Refrigerant for Air-Conditioner HFC-152a and HFC-152a

  • Lee, Jong-In;Kwon, Il-Wook;Ha, Ok-Nam
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.3
    • /
    • pp.140-149
    • /
    • 2003
  • In these days, environmental concerns have been increased throughout the industry and community worldwide. To prevent the ozone depletion, ozone depletion potential of a refrigerant must be zero. Simultaneously, a refrigerant with low GWP (global warming potential) is very demanding to reduce green house effect. Chlorine-free HFC-l34a is a refrigerant widely used for automotive air-conditioning system because its destruction potential is ecologically zero. Although HFC-l34a has no ozone depletion potential, its global warming potential is so high that it is not considered as a perfect alternative refrigerant that is acceptable for long-term use. In this paper, experimental measurement has been carried out to analyze the performance characteristics of automotive air-conditioning system using HFC-152a, which has low GWP and zero ODP. Also mixed refrigerant that is composed of HFC-152a and $CF_3$ was applied to investigate an alternative possibility for the automotive air-conditioning system. As a result of this study, we could draw following conclusions; With respect to the variation of the rotational speed of compressor, outside air temperature and flow rate, the heat amount of evaporator and compressor and performance coefficient was varied.

An Experimental Study on the Freezing Protection Valve Using Phase Change Material(PCM) for the Heat Exchanger (상변화물질(PCM)을 이용한 열교환기용 동파방지밸브에 관한 실험적 연구)

  • Yun, Jea-Ho;Kim, Joung-Ha;Jeong, Soon-Young;Yang, Yoon-Sub;Kim, Seong-Hyun;Song, Duk-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.127-133
    • /
    • 2012
  • This paper is an experimental study on the freezing protection valve used for solar water heating, air-conditioning systems, and plumbing systems. When the phase change occurs from liquid to solid, most of the substances except water volumetrically shrink. And referred to as PCM(Phase Change Material) a substance with such properties, the phase change temperature varies depending on the material. To prevent the freezing of the plumbing system, such as air-conditioning system in the winter season, we developed a several types of freezing protection valve using PCM whose freezing temperature are $2-4^{\circ}C$. The working principle of the freezing protection valve is that the fluid inside the pipe is released to prevent the system-collapse when fluid temperature reaches the freezing temperature of the PCM. And then the valve is closed and returned to the original position automatically when the temperature of the operating fluid rises. In this paper, the operating temperatures, discharge flow rate and the response characteristics of the valve during the operation are tested and investigated. From the results of this research the freezing protection valves employing PCM are expected to be commercialized in the near future.

A Case Study on Green Remodeling of Water System in Jeju Airport (우수 시스템을 적용한 친환경 리모델링 방안 : 제주 국제공항을 대상으로)

  • Kim, Byung-Hyun;Na, Su-Yeun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.6
    • /
    • pp.464-469
    • /
    • 2007
  • The case study aims to propose the green remodeling strategies of water system in Jeju international airport facilities considering the environmental conditions of Jeju Island. The rain water was proposed as an alternative water source to conserve of under ground water resources. Computations of daily precipitation, rain collection, runoff and water usage was conducted to investigated the feasibility of the rain water system design.

A Study on the Water Resource and Environmental Pollution Level of Education Facilities in Green Building Certification Criteria (학교시설 친환경건축인증 사례를 통한 수자원 및 환경오염 평가항목 연구)

  • Kwag, Moon-Geun;Choi, Chang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.678-687
    • /
    • 2009
  • The purpose of this study is to develop the assessment category, items, a detail standard for environmentally friendly evaluation on the school. and to analyze the plan to improve the level of certification criteria on the School's water resource and environmental pollution. The results of this study brings on promoted environmentally friendly appreciation, resource con servation, reduction of contaminant, accordance in and around building, etc. For this purpose, analysis of domestic and foreign environmental friendly architectural citation screening system-BREEAM (1991), LEED 2.0(2001) etc.-was preceded, and through interview, survey and forum with professional group, developed evaluation item was verified and reappraised. Developed evaluation item were composed of 40 schools about water resource and environmental pollution.

A Study on the Indoor Environment Condition in Green Building Certification Criteria (학교시설 친환경인증 사례를 통한 실내 환경 평가항목 분석)

  • Shin, Yoo-Jin;Kwag, Moon-Geun;Choi, Chang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.579-588
    • /
    • 2010
  • According to the increasing concern about health and environment, students need to study in comfort and clean environment facilities. We did field survey on 40 primary schools to analyze the present condition of design and construction for the part of indoor environmental performance in the certificated green school building. We hope that this paper will offer the important data about the indoor environment standards and performances in primary school facilities.