• Title/Summary/Keyword: Gravimetric sampling methods

Search Result 9, Processing Time 0.026 seconds

Comparative Evaluation of Gravimetric Measurement Methods for Suspended Particles in Indoor and Outdoor Air (실내.외 공기 중 부유먼지 측정방법 상호간의 비교평가 - 중량법을 대상으로)

  • 백성옥;박지혜;서영교
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.4
    • /
    • pp.285-295
    • /
    • 2002
  • In this study, several types of gravimetric methods (such as high, medium, low, and ultra low volume sampling methods) were applied to determine suspended particulate matter concentrations in both ambient and indoor environments. Comparative evaluations were undertaken with SPM data obtained using a variety of samplers (TSP, PM10, and PM4.0) at different sampling flow rates. Correlation coefficients between TSP and PM10 concentrations measured at different flow rates fell in the range of 0.73∼0.94 (n=40). In addition, correlation coefficients for PM concentrations measured by different TSP samplers were in the range of 0.90∼0.95 (n=36 or n=38), while 0.77∼0.91 (n=38) for PM10 samplers. Correlation analysis was also conducted on indoor monitoring data that were measured using ultra-low-volume samplers at both different or identical flow rates. The correlation coefficients were in the range of 0.98∼0.99 (n=38) between TSP and TSP and 0.92∼0.94 (n=38) between TSP and PM10. The mean ratio for high volume PM10 to TSP concentration that was monitored at identical flow rates in the ambient air appeared to be 0.72. The mean ratios of PM10 to TSP and PM4.0 to TSP observed with identical flow rates at indoor environments were 0.47 and 0.40. The results of this study may provide empirical information concerning the compatability of aerosol data obtained by gravimetric sampling methods at different flow rates.

Analysis of Measurement Error for PM-2.5 Mass Concentration by Inter-Comparison Study (비교 실험을 통한 PM-2.5 질량농도의 측정오차 분석)

  • Jung, Chang-Hoon;Park, Jin-Hee;Hwang, S.M.
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.4
    • /
    • pp.431-441
    • /
    • 2010
  • In this study, inter-comparison for PM-2.5 was undertaken. The PM-2.5 mass concentrations using the gravimetric and beta-attenuation methods were compared during the winter in 2007. Two different types of conventional filter-based measurements (Cyclone type and Impactor type) were also collocated and the measurement data was compared with each other. As a result, continuous PM-2.5 data using beta attenuation method show a comparable mass concentration with gravimetric measurement when the inlet of beta-gauge sampler is heated. The results also showed that the cyclone type shows a little high PM-2.5 concentration than Impactor type. In all the sampling cases, the correlations between measurement methods are high. Subsequently, this study suggests that highly correlated relationship between PM-2.5 measurement instruments can be obtained through the inter-comparison results based on filterb-ased gravimetric method and more intensive measurement and theoretical studies are needed in order to clarify the measurement errors for different sampler types.

Relationships between TSP and PM10 Concentrations in the Ambient Atmosphere (대기 중 TSP와 PM10 농도의 관련성)

  • 최진수;백성옥
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 1998
  • Relationships between TSP and PM10 concentrations were evaluated using their respective data sets collected from Taegu and Kyeungsan areas during the period of December 1993 to November 1994. The collection of data was made using the gravimetric and $\beta$-ray absorption ($\beta$-MPM) methods for 7 days of every month from three urban sites in Taegu and one suburban site in Kyeungsan. Correlation coefficients between TSP and PM10 concentrations for these four sampling sites were found in the range of 0.85 $\sim$ 0.96. Correlation analysis was also conducted for $\beta$-PM concentration data that were measured only from the residential and commercial sites. The correlation coefficients between TSP and $\beta$-PM concentrations were 0.9 in the residential site and 0.8 in the commercial site. By contrast, the correlation coefficients between PM10 $\beta$-PM concentrations were almost identical for both the residential and commercial sites with a value of 0.88. The mean ratio for PM10 to TSP concentrations for all sites was appeared to be 0.68. The analysis of seasonal trends in PM10/TSP ratios showed that the contribution of PM10 to TSP concentrations was more significant during winter (0.70 $\sim$ 0.75) than during summer (0.61 $\sim$ 0.68). The results of this study may provide empirical informations on the compatability of aerosol data measured by different sampling methods.

  • PDF

Comparative Evaluation of Gravimetric Measurement Samplers for Fine Particles by Sampling Flow Rates and Meteorological Conditions (샘플유량과 기상조건에 따른 미세먼지 중량 측정용 기구간의 농도 비교)

  • Yang Won Ho;Kim Dae Won;Kim Jin Kuk;Yoon Chung Sik;Heo Yong;Lee Bu Yong
    • Journal of Environmental Science International
    • /
    • v.14 no.1
    • /
    • pp.91-96
    • /
    • 2005
  • Several samplers using gravimetric methods such as high-volume air sampler, MiniVol portable sampler, personal environmental monitor(PEM) and cyclone were applied to determine the concentrations of fine particles in atmospheric condition. Comparative evaluation between high-volume air sampler and Minivol portable sampler for $PM_{10}$, and between Minivol portable sampler and PEM was undertaken from June, 2003 to January 2004. Simultaneously, meteorological conditions such as wind speed, wind direction, relative humidity and temperature was measured to check the factors affecting the concentrations of fine particles. In addition, particle concen­trations by cyclone with an aerodynamic diameter of $4{\mu}m$ were measured. Correlation coefficient between high­volume air sampler and portable air sampler for $PM_{10}$ was 0.79 (p<0.001). However, the mean concentration for $PM_{10}$ by high-volume air sampler was significantly higher than that by Minivol portable sampler (p=0.018). Correlation coefficient between Minivol portable sampler and PEM for $PM_{2.5}$ as 0.74 (p<0.001), and the measured mean concentrations for $PM_{2.5}$ did not show significant difference. Difference of the measured con­centrations of fine particle might be explained by wind speed and humidity among meteorological conditions. Particle concentration differences by measurement samplers were proportional to the wind speed, but inversely proportional to the relative humidity, though it was not a significant correlation.

Comparison of the PM10 Concentration in Different Measurement Methods at Gosan Site in Jeju Island (제주도 고산 측정소의 미세먼지 측정방법에 따른 질량농도 비교)

  • Shin, So-Eun;Kim, Yong-Pyo;Kang, Chang-Hee
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.4
    • /
    • pp.421-429
    • /
    • 2010
  • The reliability of the measurement of ambient trace species is an important issue, especially, in background area such as Gosan in Jeju Island. In a previous episodic study, it was suggested that the PM10 measurement result by the gravimetric method(GMM) was not in agreement with the result by the ${\beta}$-ray absorption method(BAM). In this study, a systematic comparison was carried out for the data between 2001 and 2008 at Gosan(GMM and BAM) and Jeju city (BAM) which is near to Gosan. It was found that at Gosan the PM10 concentration by BAM was higher than GMM and the correlation between them was low. The BAM results at Gosan and Jeju city showed similar trend implying the discrepancy at Gosan was not caused by instrumental problem of the BAM at Gosan. Based on the previous studies two probable reasons for the discrepancy are identified; (1) negative measurement error by the evaporation of volatile ambient species at the filter in GMM such as nitrate and ammonium and (2) positive error by the absorption of water vapor during measurement in BAM. There was no heater at the inlet of BAM at Gosan during the sampling period. Based on the size-segregated measurement data, it was identified that the evaporation error was minor, if any. The relationship between the two methods did not vary with the ambient relative humidity. Thus, at present, it is not clear why the discrepancy had been occurring and when using the PM10 data at Gosan, one should be aware the possible errors.

Comparison of the measurement methods of soil water content by error analysis (토양수분(土壤水分) 함량(含量) 측정방법별(測定方法別) 오차분석(誤差分析)에 의(依)한 비교(比較))

  • Eom, K.C.;Ryu, K.S.;Um, K.T.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.21 no.4
    • /
    • pp.367-372
    • /
    • 1988
  • A series of field experiment was conducted to find out error range and to compare precision based on error analysis of soil water content measured with gravimetric, surface & depth neutron and gypsum block methods in a sandy loam soil. The error of soil water content measured with gravimetric (core-sampling), surface and depth neutron method showed quardratic curve, whereas that with gypsum block was exponential curve in relation to soil water content. Within the range of volumetric soil water content from 11 to 33%, the error of soil water content measured with gravimetric, surface neutron, depth neutron and gypsum block method was ranged from 0.28 to 3.49%, 0.71 to 2.63%, 0.52% to 1.01% and 0.05 to 21.89%, respectively. The error of soil water content measured with depth neutron method was lower than those of other methods, when the soil water content was more than 14% in sandy loam soil. The relative number of replicates of soil water measurement for surface neutron, depth neutron and gypsum block method to attain same precision for gravimetric method was 0.6-1.7, 0.07-0.8 and 0.1-125, respectively.

  • PDF

Comparison of Sampling Methods for On-Farm Use Quick Test Procedure of Soil Nitrate (토양의 질산태질소 현장검정을 위한 시료 채취방법 비교)

  • Kang, Seong-Soo;Kim, Ki-In;Chung, Keun-Yook;Hong, Soon-Dal
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.1
    • /
    • pp.32-37
    • /
    • 2005
  • The procedure of soil sampling for on-farm quick test of soil nitrate is very important to improve practical application without weighing or drying soil. To improve application of test strip reflectometer as a quick on-farm analytical procedure for the estimation of soil nitrate concentration, three sampling methods such as gravimetric sampling (GS), particle density sampling (PDS) and bulk density sampling (BDS) for on-farm analytical procedure were investigated with twelve soils of 45 to $281mg\;kg^{-1}$ nitrate nitrogen concentration. The nitrate nitrogen concentrations measured from different soils were compared with two analytical methods, ion electrode method as a standard laboratory analysis (SLA) and test strip reflectometer at three moisture conditions, viz. air dried soil, 20 and 40% of maximum water holding capacity (MWHC). Nitrate nitrogen concentration measured by test strip reflectometer was significantly correlated with that of SLA, and the coefficients of variation (CV) were in the range of 3.5 to 10.9%. These CV values less than 10.9% were thought to be acceptable for the measurement of soil nitrate as an on-farm real time analytical procedure. The nitrate nitrogen concentration by BDS for test strip reflectometer as well as ion electrode method was more similar to that of SLA compared with those by GS and PDS especially in case of moist soils. This result suggests that the BDS is more useful than GS and PDS in case of on-farm analytical procedure of soil nitrate for moist soils. Further the practical measurement by BDS could be improved by substituting the bottle cap with a larger container.

Depositional Characteristics of Atmospheric PBDEs on Pine Needles, Bark and Soil (대기 중 폴리브롬화디페닐에테르의 소나무 잎, 소나무 껍질 및 토양으로의 침착 특성)

  • Chun, Man Young
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.3
    • /
    • pp.215-224
    • /
    • 2014
  • Objective: This study was carried out in order to determine the depositional characteristics of pine needles, pine bark, and soil used as a passive air sampler (PAS) for atmospheric polybrominated diphenyl ethers (PBDEs). Methods: All three media were sampled from the same site. The PBDE concentrations were analyzed by HRGC/HRMS, and the lipid contents were measured using the gravimetric method by n-hexane extraction. Results: The total PBDE concentration was the highest in soil (22,274.57 pg/g dry), followed by pine bark (20,266.39 pg/g dry), and then pine needles (7,380.22 pg/g dry). Pine needles contained the highest lipid contents (21.31 mg/g dry), whereas soil (10.01 mg/g dry), and pine bark (4.85 mg/g dry) contained less. There were poor correlations between lipid content and total PBDE concentrations in the media ($R^2$=0.8216, p=0.2814). Congeners BDE 47, 99, 183, 196, 197, 206, 207 and 209 showed peak concentrations. Among these, BDE 206, 207, and 209 are highly brominated PBDEs that exist as particulates in ambient air. They accounted for 81.2% [69.2 (pine needles) - 89.0% (tree bark)] of the concentration and therefore are noted as the main congener of the total PBDEs. Conclusions: It can therefore be concluded that for reducing error by improper sampling, the same species of media should be recommended for use as a PAS for atmospheric PBDEs due to the differences in depositional characteristics.

Exposure Assessment of Dust, Ultra Fine Dust(Particulate Matter 2.5, PM2.5) and Black Carbon among Aircraft Cabin Cleaners (항공기 기내 청소노동자의 분진, 초미세먼지(PM2.5) 및 블랙카본 노출수준 평가)

  • Hyunhee Park;Sedong Kim;Sungho Kim;Seung-Hyun Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.171-187
    • /
    • 2023
  • Objectives: Aircraft cabin cleaning work is characterized by being performed within a limited time in a narrow and enclosed space. The objective of this study was to evaluate the exposure levels to dust, ultra fine dust(PM2.5) and black carbon(BC) among aircraft cabin cleaners. Methods: Active personal air sampling for respirable dust(n=73) and BC(n=47) was conducted during quick transit cleaning(cabin general and vacuum-specific) and seat cover replacement and total dust and PM2.5 were area-air-sampled as well. Also, size distribution of particle was identified with the cleaning workers targeted. Dusts were collected with PVC filters using gravimetric analysis. The concentration of PM2.5 and the particle size distribution were measured with real-time direct reading portable equipment using light scattering analysis. The concentration of BC was measured by aethalometer(filter-based real-time light absorption analysis instrument). Results: The geometric mean of respirable dust was the highest at vacuum cleaning as 74.4 ㎍/m3, following by replacing seat covers as 49.3 ㎍/m3 and cabin general cleaning as 47.8 ㎍/m3 . The arithmetic mean of PM2.5 was 4.83 ~ 9.89 ㎍/m3 inside the cabin, and 28.5~44.5 ㎍/m3 outside the cabin(from bus and outdoor waiting space). From size distribution, PM2.5/PM10 ratio was 0.54 at quick transit cleaning and 0.41 at replacing seat covers. The average concentration of BC was 2~7 ㎍/m3, showing a high correlation with the PM2.5 concentration. Conclusions: The hazards concentration levels of aircraft cabin cleaners were very similar to those of roadside outdoor workers. As the main source of pollution is estimated to be diesel vehicles operating at airports, and it is necessary to replace older vehicles, strengthen pollutant emission control regulations, and introduce electric vehicles. In addition, it is necessary to provide as part of airport-inftastructure a stable standby waiting space for aircraft cabin cleaners and introduce a systematic safety and health management system for all workers in the aviation industry.