• Title/Summary/Keyword: Gravimetric Method

Search Result 209, Processing Time 0.031 seconds

Morphological, Thermal and Dynamic Mechanical Properties of Polyurethane Product with Various Contents of Acrylic Polyol (Acrylic Polyol 함량을 달리한 폴리우레탄 제품의 형태학적 열적 및 동적·기계적 성질)

  • Kim, Tae Sung;Park, Chan Young
    • Elastomers and Composites
    • /
    • v.48 no.4
    • /
    • pp.276-281
    • /
    • 2013
  • Polyester type polyurethane foam modified with acrylic polyol was prepared by quasi prepolymer method. Thermal and dynamic mechanical properties of polyurethane foam were analysed by thermal gravimetric analysis(TGA) and dynamic mechanical analysis(DMA). Also, glass transition temperature was measured by differential scanning calorimeter(DSC). As acrylic polyol contents were increased, thermal stability measured by TGA was slightly decreased. Storage modulus was increased and tan delta was decreased with increasing of acrylic polyol contents.

A Study on the Cleanliness Evaluation Methods for the Selection of Alternative Cleaning Agents (대체 세정제의 선정을 위한 세정성 평가방법 연구)

  • Shin, Jin-Ho;Lee, Jae-Hoon;Bae, Jae-Heum;Lee, Min-Jae;Hwang, In-Gook
    • Clean Technology
    • /
    • v.15 no.2
    • /
    • pp.81-90
    • /
    • 2009
  • In this study various cleaning evaluation methods were tested and comparatively evaluated to help cleaning industry. In order to select alternative cleaning agents objectively and systematically, various cleaning evaluation methods such as gravimetric, optically simulated electron emission (OSEE), contact angle, and analytical instrument methods were employed for cleaning contaminants such as flux, solder and grease. The analytical instruments used in this work were Fourier transform infrared spectroscopy (FTIR), ultraviolet visible spectroscopy (UV-VIS) and high performance liquid chromatography (HPLC). The gravimetric method was able to measure cleaning efficiencies easily and simply, but it was not easy to analyze them precisely because of its limitation in the gravimetric measurement. However, the OSEE technique was able to measure quickly and precisely the clean ability of cleaning agents in comparison with the gravimetric method. The contact angle method was found to be necessary for taking special precaution in its application to the cleaning evaluation due to possible formation of tiny organic film on the substrate surface which might be generated from contaminants and cleaning agents. In case of precision analysis that cannot be done by gravimetric method, fine analytical instruments such as UV-VIS, FTIR and HPLC could be used in analyzing trace amount of flux, solder and grease quantitatively, which were extracted from the surface by special solvents.

A Study on the Evaluation of Cleaning Ability Using Optically Stimulated Electron Emission Method (광전자방출(OSEE)법을 이용한 세정성 평가 연구)

  • Min, Hye-Jin;Shin, Jin-Ho;Bae, Jae-Heum
    • Clean Technology
    • /
    • v.14 no.2
    • /
    • pp.95-102
    • /
    • 2008
  • In order to choose alternative environmental-friendly cleaning agents, it is very important in the present point that the systematic selection procedures should be introduced and applied to the industry through the evaluation of their cleaning ability, environmental characteristics, and economical factors, and that the objective and effective evaluation methods of cleanliness should be established for the industry. Thus, a novel cleaning evaluation method utilizing optically stimulated electron emission (OSEE) among various methods of cleaning ability was studied in this study. The contaminants used in this cleaning experiments were flux, solder, grease, cutting oil, and mixed soil of 35% grease and 65% cutting oil. The cleaning agents developed or prepared in our laboratory were employed and their cleaning ability were comparatively evaluated by the OSEE, gravimetry and contact angle methods. The experimental results in this work showed that flux cleaning efficiency measured by the OSEE method was similar to that of the gravimetric method, but that the OSEE method could not be compared with gravimetric method for the case of solder or grease cleaning because the contaminants radiate or absorb ultra-violet light. In case of cutting oil cleaning, the gravimetric method indicated its limitation of cleaning efficiency of cutting oil since it showed cleaning efficiency of 100%, even though residual soil remaining on the substrate surface a little after its cleaning. The comparative experimental results of cleaning ability evaluated by the OSEE- and contact angle measurement methods showed that they were similar in case of cleaning of flux, mixed soil and cutting oil. It was judged that the contact angle measurement method could evaluate the cleaning ability more precisely than the OSEE method for cleaning solder and grease.

  • PDF

A Study on the Measurement Uncertainty of Pipe Prover (파이프 프루버의 측정불확도에 관한 연구)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.10
    • /
    • pp.1388-1398
    • /
    • 2000
  • A pipe prover is a flowmeter calibrator used in flow measurement field. Gravimetric and volumetric methods were applied to determine the basic volume of the pipe prover. Uncertainty of its basic volume measurement was evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainty of determining the basic volume was estimated from the sensitivity coefficient and the standard uncertainty of independent variables. It was found that the uncertainties of the weighing and volume measurements have dominant influence on that of the basic volume determination. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of the basic volume is shown clearly.

Image Analysis: A Novel Technique to Determine the Efficiency of Wiping Cloths

  • Lee Jae-Hyung;Kim Seong-Hun;Oh Kyung-Wha
    • Fibers and Polymers
    • /
    • v.7 no.1
    • /
    • pp.73-78
    • /
    • 2006
  • The ability to absorb liquid and the dust removal performance are important factors for wiping cloths used to remove contaminants. We have developed a method that can determine the contaminant removal performance of wiping cloths. In the gravimetric method, experimental errors are unavoidable because the contaminant plate is much heavier than the contaminant material. However, we used image analysis to reduce the experimental errors, and did not use the heavy contaminant plate. The correlation coefficient between the image. analysis and the gravimetric methods was very high, at R=0.97, with a significance level of 95%. From the correlation analysis and empirical data, the image analysis method is a useful tool for measuring wiping efficiency. The wiping efficiency measured using image analysis has a close relationship to the wiping speed, viscosity of the contaminant, and wiping pressure, at the significance level of 95%.

Uncertainty Characteristics of Diverter for Flowmeter Calibration System (액체용 유량계 교정시스템의 Diverter 불확도 특성 연구)

  • Lee, Dong-Keun;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.3
    • /
    • pp.50-55
    • /
    • 2008
  • The diverter system is a key component in achieving a high accuracy liquid flow rate standard using a static gravimetric system with a flying start and stop method. The diverter is a moving device used to direct flow alternately along its normal course(by pass) or towards the weighing tank. The time needed for collection into the weighing tank is measured using a timer. So it is important to the diversion period is sufficiently fast and triggering point of timer which is determined the filling time. On this studies show that uncertainty of diverter system for changing diversion speed and triggering point was estimated in accordance with Guide to The Expression of Uncertainty in Measurement(ISO).

Density Measurement of Powdery and Porous Substances with a Gravimetric BET Adsorption Apparatus

  • Kim Han-Sung;Cho Hyun-Woo;Lee Kwang-Soon;Ahn Woon-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.3
    • /
    • pp.332-334
    • /
    • 1992
  • An accurate method of density measurement is proposed. The method makes use of a gravimetric adsorption apparatus and is quite suitable for powdery and porous solid samples. The sample volume is determined by measuring its buoyancy with microbalance and the mass is measured in vacuum in the absence of buoyancy effect. Densities of inorganic compounds, such as alumina and perovskite, and some organic compounds are determined with the proposed method, and the results are compared with the values either determined with conventional methods or obtained from literatures.

PM10 β-ray attenuation samplers (β-ray absorption method) equivalence evaluation and comparatively observed study (PM10 연속자동측정기(β-ray) 등가성평가 및 비교관측 연구)

  • WonSeok Jung;Hee-Jung Ko;Wonick Seo;Jiyoung Jeong;Sang Min Oh;Kyung-On Boo
    • Particle and aerosol research
    • /
    • v.19 no.1
    • /
    • pp.13-20
    • /
    • 2023
  • The Asian dust observation network operates β-ray attenuation samplers to measure PM10 concentrations. In addition, equivalence evaluation and accuracy inspection(Precision Tests) are conducted every year for the reliability of data. β-ray attenuation samplers(16 units) were comparatively observed from May to June 2020 and from July to December 2021. During the observation period, the average daily temperature was the lowest at 6.4℃ in December and the highest at 27.3℃ in August. The average daily humidity ranged from 60% to 100%, but the average daily humidity was over 75% from July to September. The minimum value of the PM10 Gravimetric method was 5.0 ㎍/m3, the maximum value was 53.4 ㎍/m3, and the average value was 17.8 ㎍/m3. The equivalence evaluation results of the PM10 Gravimetric method and β-ray attenuation samplers satisfied the criteria (slope: 1±0.1, intercept: 0±0.5). A relative error analysis between the PM10 Gravimetric method and β-ray attenuation samplers equipment showed that the relative error increased when the concentration was low and the temperature and humidity were high. In addition, in the β-ray attenuation samplers 5-minute interval observation data in May 2020, a relatively large Standard devication was shown as an average maximum ±23.4 ㎍/m3 and a minimum ±15.2 ㎍/m3. At standard deviations of 10% and 90%, equipment with high variability (deviation) was measured at 6 ㎍/m3and 61 ㎍/m3, and equipment with low variability was measured at 12 ㎍/m3 and 47 ㎍/m3. It was confirmed that concentration differences occurred due to differences in variability for each equipment.

An Experimental Study on Measurement of Chemical Kinetic Parameters of a Liquid Fuel with Various Components (혼합 액체 연료의 화학반응 인자 계측에 관한 실험적 연구)

  • Choi, Hyo-Hyun;Lim, Jun-Seok;Kim, Chul-Jin;Sohn, Chae-Hoon
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.3
    • /
    • pp.21-26
    • /
    • 2011
  • Thermal analyses are conducted to measure chemical kinetic parameters of an unknown liquid fuel with various components. Thermal Analyses are divided into two different methods such as TGA(Thermo-Gravimetric Analysis) and DSC(Differential Scanning Calorimety). Non-isothermal experimental results are analyzed by adopting TGA and they are filtered by Freeman-Carroll method. As a results of the analysis, chemical parameters of the activation temperature and the reaction order are measured to be 6128.2 K and 1.4, respectively. Furthermore, the chemical kinetic parameters are obtained by a variety of mathematical processing methods. It has been found that they show a little difference depending on the processing method.